Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Form | Length | Material | Device | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Cable cross section | Transported air temperature | Voltage | Regulator | Air pass | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Motor IP rating | LED-light power | Cable cross section | * | *** |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Quatro Hi-Tech Gold 100 (127-220V/60Hz) | 127 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.115 | 10 | 82 | 33* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 23 | 0.44 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Hi-Tech Gold 100 (127-220V/60Hz) | 220 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.054 | 9 | 82 | 33* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 23 | 0.40 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-R 80/80x6 V3(1 speed) | 230 | - | Inline | centrifugal | 80 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.32 | - | - | - | 50 | 1400 | - | 88 | Exhaust, Supply | 3.6 | 20 | 50 | C | IPX4 | - | 32 | - | - | - | - | - | - | - | - | - | 24 | - | - | - | - | - |
Box-R 80/80x6 V3(2 speed) | 230 | - | Inline | centrifugal | 80 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.34 | - | - | - | 50 | 1800 | - | 130 | Exhaust, Supply | 3.6 | 26 | 50 | C | IPX4 | - | 35 | - | - | - | - | - | - | - | - | - | 36 | - | - | - | - | - |
Box-R 80/80x6 V3(3 speed) | 230 | - | Inline | centrifugal | 80 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.4 | - | - | - | 50 | 2600 | - | 162 | Exhaust, Supply | 3.6 | 45 | 50 | C | IPX4 | - | 43 | - | - | - | - | - | - | - | - | - | 45 | - | - | - | - | - |
BlauPlast RS 80-150 | - | - | - | - | - | for round air ducts | 125 | - | - | - | - | - | round | - | plastic | reducer | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RR 125/1 | - | - | - | - | 125 | - | - | - | - | - | - | - | round | 1000 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Line 150 | 220-240 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 24 | 292 | 38* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 81 | 0.3 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Still Vintage 125 | 220-240 | Vintage | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 9.4 | 158 | 31 | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 44 | 0.21 | - | - | - | - | - | - | - | - |
Turbo 125 min | 230 | - | Inline | mixed-flow | 125 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.11 | - | 230 | - | 50/60 | 1535 | - | - | Exhaust, Supply | 1.79 | 25 | 60 | B | IPX4 | 1 | 29 | - | - | - | - | - | 64 | - | - | - | - | IP44 | - | - | - | - |
Turbo 125 max | 230 | - | Inline | mixed-flow | 125 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.13 | - | 345 | - | 50/60 | 2265 | - | - | Exhaust, Supply | 1.79 | 29 | 60 | B | IPX4 | 1 | 34 | - | - | - | - | - | 96 | - | - | - | - | IP44 | - | - | - | - |
Valeo-BF 35/60/100 (3 speed) |
220-240 | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.18 | - | 102 | - | 50 | - | III | - | Exhaust | - | 44 | +50 | - | IP55 | - | 46 | 4х1.5 | - | - | - | - | 28 | - | - | - | - | - | - | - | - | - |
Valeo-BF 35/60/100 (1 speed) |
220-240 | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.12 | - | 35 | - | 50 | - | I | - | Exhaust | - | 15 | +50 | - | IP55 | - | 27 | 4x1.5 | - | - | - | - | 10 | - | - | - | - | - | - | - | - | - |
Valeo-BF 35/60/100 (2 speed) |
220-240 | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.14 | - | 63 | - | 50 | - | II | - | Exhaust | - | 25 | +50 | - | IP55 | - | 36 | 4x1.5 | - | - | - | - | 18 | - | - | - | - | - | - | - | - | - |
Decor 180x180Rs | - | - | wall mounting | rectangular flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | manual | 0.0091 | - | - | - | - | - | - | - | - | - | - |
Ducto Power Plus 150 min | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.103 | 22 | 285 | 38* | 50 | 2300 | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | 79 | 0.28 | 1.3 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ducto Power Plus 150 max | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.109 | 25 | 375 | 41* | 50 | 2600 | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | 104 | 0.24 | 1.3 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 200 Light (50 Hz, min) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 20 | 130 | 24* | 50 | 714 | min | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 36 | 0.55 | 6.4 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 200 Light (50 Hz, max) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 29 | 210 | 27* | 50 | 1026 | max | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 58 | 0.50 | 6.4 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 200 Light (60 Hz, min) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.11 | 21 | 130 | 24* | 60 | 588 | min | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 36 | 0.58 | 6.4 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 200 Light (60 Hz, max) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.15 | 34 | 225 | 28* | 60 | 936 | max | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 63 | 0.54 | 6.4 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Hi-Tech 125 (127-220V/60Hz) | 127 | Hi-Tech | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.119 | 16 | 170 | 35* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.34 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Hi-Tech 125 (127-220V/60Hz) | 220 | Hi-Tech | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.102 | 15 | 170 | 35* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.32 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-R 200 V2 (1 speed) | 1 ~ 230 | - | Inline | centrifugal | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.45 | - | - | - | 50 | 770 | - | 460 | Exhaust, Supply | 8.8 | 103 | 50 | C | IPX4 | - | 46 | - | - | - | - | - | - | - | - | - | 128 | - | - | - | - | - |
Box-R 200 V2 (2 speed) | 1 ~ 230 | - | Inline | centrifugal | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.63 | - | - | - | 50 | 1200 | - | 752 | Exhaust, Supply | 8.8 | 142 | 50 | C | IPX4 | - | 48 | - | - | - | - | - | - | - | - | - | 209 | - | - | - | - | - |
BlauPlast RS 100/150 | - | - | - | - | - | for round air ducts | - | - | - | - | - | - | round | 70 | plastic | reducer | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo DC 150 | 120-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.24 (0.39) | 26 | 254 | 23-29* | 50/60 | 1100 | - | - | Exhaust | - | - | - | B*** | IPX4 | - | - | - | - | - | - | - | 71 | 0.37 | 5.1 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Bravo Platinum 100 (127-220V/60Hz) | 127 | Platinum | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.115 | 10 | 91 | 33* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 25 | 0.4 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Bravo Platinum 100 (127-220V/60Hz) | 220 | Platinum | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.054 | 9 | 91 | 33* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 25 | 0.36 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Сentro-M 200 (60 Hz) | 220-240 | - | Inline | centrifugal | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.79 | - | 1220 | - | 60 | 3120 | - | - | Exhaust, Supply | - | 182 | - | – | IPX4 | 1 | 50 | - | -25...+45 | - | - | - | 339 | - | 6.6 | - | - | IP44 | - | - | - | - |
Сentro-M 200 (50 Hz) | 220-240 | - | Inline | centrifugal | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.59 | - | 1070 | - | 50 | 2710 | - | - | Exhaust, Supply | - | 135 | - | C | IPX4 | 1 | 48 | - | -25…+45 | - | - | - | 294 | - | 6.6 | 2018 | - | IP44 | - | - | - | - |
Valeo 75/100 (1 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.11 | - | 75 | 29* | 50 | - | I | - | Exhaust | - | 24 | +50 | - | - | - | - | - | - | 220-240 | - | - | 21 | - | - | - | - | IP55 | - | 3x1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Valeo 75/100 (2 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.13 | - | 100 | 38* | 50 | - | II | - | Exhaust | - | 29 | +50 | - | - | - | - | - | - | 220-240 | - | - | 28 | - | - | - | - | IP55 | - | 3x1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Decor 180x250Rs | - | - | wall mounting | rectangular flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | manual | 0.0146 | - | - | - | - | - | - | - | - | - | - |
Ducto Plus 100 min | 220-240 | White | Inline | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.029 | 4.5 | 75 | 22* | 50 | 1650 | min | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | 21 | 0.22 | 0.61 | - | - | - | - | - | - | - |
Ducto Plus 100 max | 220-240 | White | Inline | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.049 | 7.5 | 110 | 25* | 50 | 2100 | max | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | 31 | 0.25 | 0.61 | - | - | - | - | - | - | - |
DECOR 81x136 R | - | - | - | - | - | for rectangular air ducts | - | - | - | - | - | - | rectangular | - | plastic | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Quatro 150 (127-220V/60Hz) | 127 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.175 | 25 | 240 | 37* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 67 | 0.37 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro 150 (127-220V/60Hz) | 220 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.338 | 25 | 240 | 37* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 67 | 0.37 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-R 125 max | 1 ~ 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.55 | - | - | - | 50 | 2800 | - | 414 | Exhaust, Supply | 5.8 | 127 | 50 | C | IPX4 | - | 47 | - | - | - | - | - | - | - | - | - | 115 | - | - | - | - | - |
BlauPlast RVPK 150 | - | - | - | - | 150 | for round air ducts | - | - | - | - | - | - | round | - | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo 300 Light (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.15 | 31 | 220 | 28* | 50 | 936 | min | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 61 | 0.51 | 6.2 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 300 Light (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.22 | 49 | 300 | 31* | 50 | 1254 | max | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 83 | 0.59 | 6.2 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 300 Light (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.17 | 35 | 200 | 27* | 60 | 888 | min | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 56 | 0.63 | 6.2 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 300 Light (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.28 | 63 | 320 | 32* | 60 | 1320 | max | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 89 | 0.71 | 6.2 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |