Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Print version
Search results
Selected 1173 products
Mode VoltageStyleMountingDesignConnection diameterAir ductCasing materialEC motorOutdoor mountingSound-insulated casingHeatingFormLengthMaterialDeviceCurrentPowerMaximum air flowSound pressure levelFrequencyRPMSpeedHeat recovery efficiencyMaximum air capacityTypeWeight PowerMax. operating temperatureSEC classIngress protection ratingPhaseSound pressure level at 3 mMax. air flow at air flow direction (perpendicular air flow)Max. air flow at air flow direction (direct air flow)Heat exchanger typeHeat exchanger materialElectric heater powerInsulation classFan currentTransported air temperature Electric heater currentCurrentConnected air duct diameterFan powerAir flow in ventilation modeAir flow in heat recovery modeConnected air duct size FilterTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140Sectional sizeInsulationHeat recovery efficiencyTotal unit powerVoltageReheater power consumptionInsulation thiknessMaximum air flowSFPWeightErPExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeMotor IP ratingMax. power without electric heaterMax. unit current without electric heaterMax. unit currentMax. unit power with electric heaterMax. unit current with electric heaterCurrentPreheater power consumptionReheater power consumptionMax. current consumption with heater(s)Sound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Electric heater current Air flow in heat recovery modeAir flow in heat recovery modeRemote control panelFunctionsIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8Power*Motor max. power*****Transported air temperaturePerm. amb. temp.Max. air flow at air flow direction (direct air flow)Max. air flow at air flow direction (perpendicular air flow)
Extero 150
50 Hz
230 - Inline centrifugal 150 for round air ducts polymer-coated steel no yes no - - - - - 0.42 - 630 - 50 2400 - - - Exhaust - 96 +55 B IPX4 1 58 - - - - - - - - - - - - - - - - - - - - - - - - - 175 - 4.5 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Extero 150
60 Hz
230 - Inline centrifugal 150 for round air ducts polymer-coated steel no yes no - - - - - 0.44 - 650 - 60 2270 - - - Exhaust - 100 +55 B IPX4 1 58 - - - - - - - - - - - - - - - - - - - - - - - - - 181 - 4.5 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BlauAIR RH 6000 380-480 - floor mounting, outdoor mounting - - for rectangular air ducts aluzinc yes yes yes - - - - - - - 6000 - 50/60 1700 - - - Supply and exhaust - 2x2740 - - IP34 3 32 - - - - - F - - - - - - - - - - -25...+40 - - - - - - - - - - 559 - ePM1 55% ePM1 55% (ISO 16890)-F7 (EN779) - - IP54 - - 8.8 - - - - - - - - - - - - - - - - - - - - - - - -35...+50 - -
KOMFORT Roto EC LE 1000-4.5 S17 400 - - - - - aluzinc - - - - - - - - - - 900 - 50/60 2600 - - - - - - - A - 3 58 - - rotary aluminum 4500 - - - - - 250 - - - - - -25...+40 - - 20 mm mineral wool 72–95 - - - - 250 - 130 2016, 2018 G4 G4 - - - - - - 4940 7.2 - - - - - - - - - - - - - - - - - 2 items x 135 - - - - - -
Iso-V 630 6D 400 - Inline centrifugal - for rectangular air ducts, for round air ducts aluminium, aluzinc no yes yes - - - - - 2.8 - - - 50 880 - - - Exhaust, Supply 98 1310 - - IPX4 3 55 12030 10440 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -40...+60 - 2900 3342
Aero Chrome 100 (127-220V/60Hz) 127 Chrome ceiling mounting, wall mounting axial 100 - - - - - - - - - - 0.115 10 92 34* 60 2500 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 26 0.39 - - - - - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - - -
Aero Chrome 100 (127-220V/60Hz) 220 Chrome ceiling mounting, wall mounting axial 100 - - - - - - - - - - 0.054 9 92 34* 60 2500 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 26 0.35 - - - - - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - - -
Vento Eco2 A50-4 S11 Pro (1 speed) - - - - - 160 - - - - - - - - - 0.033 - - - 50/60 915 I - - - - 2.37 - - IP24 - - - - - - - - - - - - - - 15 - - - -20(-30**) … +40 41 - - - - 100-240 - - - 0.57 - - - - 4 - - - - - - - - - - - 21 12 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - 15 4 Sensor Filter replacement indication, Timer D1 S3*** - Maximum air flow 40 m³/h - With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - -
Vento Eco2 A50-4 S11 Pro (2 speed) - - - - - 160 - - - - - - - - - 0.047 - - - 50/60 1555 II - - - - 3.80 - - IP24 - - - - - - - - - - - - - - 30 - - - -20(-30**) … +40 41 - - - - 100-240 - - - 0.46 - - - - 8 - - - - - - - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - 30 8 Sensor Filter replacement indication, Timer D1 S3*** - Maximum air flow 40 m³/h - With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - -
Vento Eco2 A50-4 S11 Pro (3 speed) - - - - - 160 - - - - - - - - - 0.080 - - - 50/60 2330 III - - - - 7.61 - - IP24 - - - - - - - - - - - - - - 50 - - - -20(-30**) … +40 41 - - - - 100-240 - - - 0.55 - - - - 14 - - - - - - - - - - - 29 20 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - 50 14 Sensor Filter replacement indication, Timer D1 S3*** - Maximum air flow 40 m³/h - With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - -
BlauPlast FKV 204×60 - - - - - for rectangular air ducts - - - - - rectangular 62 plastic connector - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 60х204 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axis-QR 800 6D 400 - wall mounting axial 800 for round air ducts polymer-coated steel no no no - - - - - - - 25000 - 50 915 - - - Exhaust, Supply - 1850 - - IPX4 3 67 - - - - - - - - - - - - - - - - -30...+60 - - - - - - - - 6945 - 42.0 - - - - - IP44 - - - - - 3.7 - - - - - - - - - - - - - - - - - - - - - - -
Quatro Platinum 100 220-240 Platinum ceiling mounting, wall mounting axial 100 - - - - - - - - - - 0.085 14 88 33* 50 2300 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 24 0.57 - - - - - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - - -
Vento Expert A50-1 S W V.3
(I speed)
100-240 - - - - 160 - yes - - - - - - - 0.035 - - - 50/60 800 I - - - - - - - IP24 - - - - - - - - - - - - - - 15 8 - - -20...+40 41/47** - - - - - - - - 2.4 - - - - 4 2 - - - - - - - - - - 13 4 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S3*** 5.0 Maximum air flow 40 m³/h - with open and closed front panel manual setting of 100% speed in a mobile application - - - -
Vento Expert A50-1 S W V.3
(II speed)
100-240 - - - - 160 - yes - - - - - - - 0.04 - - - 50/60 1300 II - - - - - - - IP24 - - - - - - - - - - - - - - 30 15 - - -20...+40 41/47** - - - - - - - - 1.44 - - - - 8 4 - - - - - - - - - - 25 16 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S3*** 6.0 Maximum air flow 40 m³/h - with open and closed front panel manual setting of 100% speed in a mobile application - - - -
Vento Expert A50-1 S W V.3
(III speed)
100-240 - - - - 160 - yes - - - - - - - 0.059 - - - 50/60 1900 III - - - - - - - IP24 - - - - - - - - - - - - - - 50 25 - - -20...+40 41/47** - - - - - - - - 1.22 - - - - 14 7 - - - - - - - - - - 37 28 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S3*** 8.5 Maximum air flow 40 m³/h - with open and closed front panel manual setting of 100% speed in a mobile application - - - -
Clean Box 125 G4-H13-Carbon - - ceiling mounting, wall mounting, flush mounting - 125 for round air ducts polymer-coated steel - - - - - - - - - - - - - - - - - - 8.18 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tower-AM 315 (60 Hz) 230 - for roof centrifugal - for round air ducts polymer-coated steel no yes no - - - - - 1.8 - 1920 - 60 2780 - - - Exhaust 12.3 413 -25…+50 - IPX4 - 55 - - - - - - - - - - - - - - - - - - - - - - - - - 533 - - 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tower-AM 315 (50 Hz) 230 - for roof centrifugal - for round air ducts polymer-coated steel no yes no - - - - - 1.34 - 1880 - 50 2720 - - - Exhaust 12.3 296 -25…+45 - IPX4 - 54 - - - - - - - - - - - - - - - - - - - - - - - - - 522 - - 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Box 160 230 - Inline centrifugal 160 for round air ducts polymer-coated steel no no no - - - - - 0.38 - - - 50 2600 - - 553 Exhaust, Supply 6.6 85 -25 +40 B IPX4 - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Freshbox 200 ERV WiFi
Speed I
230 - - - - - polymer-coated steel - - - without heating - - - - - - 30 - 50/60 2000 I - - - - - - A - 1 - - - counter-flow enthalpy - - - - - - 100 - - - - - -15...+40 - - - 85 - - 30 8 - 55 - G4 G4 + F7 (Option: H13) - - - 10 - - - - - - 1.0 - 12 - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - -
Freshbox 200 ERV WiFi
Speed II
230 - - - - - polymer-coated steel - - - without heating - - - - - - 60 - 50/60 2000 II - - - - - - A - 1 - - - counter-flow enthalpy - - - - - - 100 - - - - - -15...+40 - - - 81 - - 30 17 - 55 - G4 G4 + F7 (Option: H13) - - - 15 - - - - - - 1.0 - 22 - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - -
Freshbox 200 ERV WiFi
Speed III
230 - - - - - polymer-coated steel - - - without heating - - - - - - 90 - 50/60 2000 III - - - - - - A - 1 - - - counter-flow enthalpy - - - - - - 100 - - - - - -15...+40 - - - 75 - - 30 25 - 55 - G4 G4 + F7 (Option: H13) - - - 25 - - - - - - 1.0 - 30 - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - -
Freshbox 200 ERV WiFi
Speed IV
230 - - - - - polymer-coated steel - - - without heating - - - - - - 120 - 50/60 2000 IV - - - - - - A - 1 - - - counter-flow enthalpy - - - - - - 100 - - - - - -15...+40 - - - 68 - - 30 33 - 55 - G4 G4 + F7 (Option: H13) - - - 44 - - - - - - 1.0 - 36 - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - -
Freshbox 200 ERV WiFi
Speed V
230 - - - - - polymer-coated steel - - - without heating - - - - - - 200 - 50/60 2000 V - - - - - - A - 1 - - - counter-flow enthalpy - - - - - - 100 - - - - - -15...+40 - - - 66 - - 30 56 - 55 - G4 G4 + F7 (Option: H13) - - - 134 - - - - - - 1.0 - 45 - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - -
KOMFORT L 530 230 - ceiling mounting, wall mounting, floor mounting - - for round air ducts aluzinc no no yes - - - - - - - 530 - 50/60 1100 - 88 - Supply and exhaust - - - E - 1 28-47 - - cross-flow polystyrene - - - - - 1.32 160 - - - - - -25...+40 - - 25 mm mineral wool - 300 - - - 147 - 49 2016 G4 G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Iso-Mix 150 min 230 - Inline mixed-flow - for round air ducts polymer-coated steel no no yes - - - - - 0.20 - 410 - 50/60 1985 min - - Exhaust, Supply 6.1 45 +60 C IPX4 1 26 - - - - - - - - - - - - - - - - - - - - - - - - - 114 - - 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Iso-Mix 150 max 230 - Inline mixed-flow - for round air ducts polymer-coated steel no no yes - - - - - 0.23 - 550 - 50/60 2640 max - - Exhaust, Supply 6.1 52 +60 C IPX4 1 33 - - - - - - - - - - - - - - - - - - - - - - - - - 153 - - 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
DECOR 86x230 - - - - - for rectangular air ducts - - - - - rectangular - plastic - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DE 3300-21 Pro 400 - ceiling mounting, wall mounting, floor mounting centrifugal - for rectangular air ducts aluzinc no no yes - - - - - - - 3350 - 50 2730 - - - Supply - - - - - 3 57 - - - - 21000 - 2.4 -25...+40 30.0 32.4 - 1.33 - - 600х350 G4 - - - 50 mm mineral wool - 22330 - - - 931 - 91 2016, 2018 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axis-Q 400 4Е
50 Hz
230 - wall mounting axial 400 for round air ducts polymer-coated steel no no no - - - - - - - 3580 - 50 1380 - - - Exhaust, Supply - 180 - - IPX4 1 53 - - - - - - - - - - - - - - - - -30...+60 - - - - - - - - 995 - 8.8 - - - - - IP54 - - - - - 0.82 - - - - - - - - - - - - - - - - - - - - - - -
Axis-Q 400 4Е
60 Hz
230 - wall mounting axial 400 for round air ducts polymer-coated steel no no no - - - - - - - 3890 - 60 1655 - - - Exhaust, Supply - 240 - - IPX4 1 54 - - - - - - - - - - - - - - - - -30...+50 - - - - - - - - 1081 - 8.8 - - - - - IP54 - - - - - 1.08 - - - - - - - - - - - - - - - - - - - - - - -
Bravo Platinum 150 (127-220V/60Hz) 127 Platinum ceiling mounting, wall mounting axial 150 - - - - - - - - - - 0.175 25 266 38* 60 2350 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 74 0.34 - - - - - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - - -
Bravo Platinum 150 (127-220V/60Hz) 220 Platinum ceiling mounting, wall mounting axial 150 - - - - - - - - - - 0.338 25 266 38* 60 2350 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 74 0.34 - - - - - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - - -
KOMFORT EC DE 2000-12 R 400 - ceiling mounting - - - aluzinc - - - - - - - - - - 2000 - 50/60 2920 - - - - - - - NRVU - 3 58 - - cross-flow aluminum 12000 - - - - - 315 - - - - - -25…+40 - - 25 mm mineral wool 75 - - - - 556 - 190 2016 G4 G4 - - - 840 5 - 12870 22.4 - - - - - - - - 17.4 - - - - - - - - - - - - - - -
KOMFORT EC DE 4000-21 R 400 - ceiling mounting - - - aluzinc - - - - - - - - - - 4000 - 50/60 2580 - - - - - - - NRVU - 3 59 - - cross-flow aluminum 21000 - - - - - 400 - - - - - -25…+40 - - 25 mm mineral wool 75 - - - - 1111 - 290 2016 G4 G4 - - - 1980 3.4 - 23000 33.4 - - - - - - - - 30.0 - - - - - - - - - - - - - - -
S-Vent 250х127-5.5-2D 400 - floor mounting centrifugal - for rectangular air ducts, for round air ducts polymer-coated steel no yes no - - - - - 10.7 - 4820 - 50 2850 - - - Exhaust, Supply 40 5500 +60 - IP54 3 81 - - - - - - - - - - - - - - - - - - - - - - - - - 1339 - - - - - - - IP54 - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Pages