Mode | Voltage | Mounting | Design | Connection diameter | Air duct | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Heating | Current | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Heat exchanger type | Heat exchanger material | Transported air temperature | Connected air duct diameter | Transported air temperature | Insulation | Heat recovery efficiency | Sound pressure level at a distance of 1 m | Voltage | Max. unit power without an electric heater | Reheater power consumption | Maximum air flow | Weight | ErP | Extract filter | Supply filter | Motor IP rating | Max. unit current without electric heater | Max. unit current with electric heater | Current | Preheater power consumption | Remote control panel | Functions | Cable cross section | * |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tower-HC 225 2E (50 Hz) | 230 | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 0.54 | 940 | - | 50 | 2787 | - | Exhaust | - | 123 | -25…+50 | – | IPX4 | 1 | 51 | - | - | - | - | - | - | - | - | - | - | - | 261 | 7 | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
Tower-HC 225 2E (60 Hz) | 230 | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 0.70 | 1040 | - | 60 | 2820 | - | Exhaust | - | 170 | -25…+50 | – | IPX4 | 1 | 52 | - | - | - | - | - | - | - | - | - | - | - | 289 | 7 | - | - | - | IP44 | - | - | - | - | - | - | - | - |
Axis-Q 800 6D | 400 | wall mounting | axial | 800 | for round air ducts | polymer-coated steel | no | no | no | - | - | 25000 | - | 50 | 915 | - | Exhaust, Supply | - | 1850 | - | - | IPX4 | 3 | 67 | - | - | - | - | -30...+60 | - | - | - | - | - | - | 6945 | 44.0 | - | - | - | IP54 | - | - | 3.7 | - | - | - | - | - |
Tower-V EC 280 | 230 | for roof | centrifugal | - | for round air ducts, for square air ducts | polymer-coated steel | yes | yes | no | - | 1.34 | 2330 | - | 50/60 | 2610 | - | Exhaust | - | 182 | -20...+60 | – | IPX4 | 1 | 48 | - | - | - | - | - | - | - | - | - | - | - | 647 | 14 | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
Axis-Q EC 250 | 230 | wall mounting | axial | 260 | for round air ducts | polymer-coated steel | yes | no | no | - | - | 1550 | - | 50/60 | 2480 | - | Supply and exhaust | - | 85 | - | - | IPX5 | 1 | 50 | - | - | - | - | –25…+60 | - | - | - | - | - | - | 431 | 2.54 | - | - | - | IP55 | - | - | 0.61 | - | - | - | - | - |
Tower-H EC 355 | 230 | for roof | centrifugal | - | for round air ducts, for square air ducts | polymer-coated steel | yes | yes | no | - | 9.36 | 3830 | - | 50/60 | 1550 | - | Exhaust | - | 669 | -25...+50 | – | IPX4 | 1 | 51 | - | - | - | - | - | - | - | - | - | - | - | 1064 | 27 | 2018 | - | - | IP54 | - | - | - | - | - | - | - | - |
Valeo-BP 35/60 (1 speed) |
- | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | plastic | no | no | - | - | 0.12 | 35 | 27* | 50 | - | I | Exhaust | - | 15 | +50 | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 10 | - | - | - | - | IP55 | - | - | - | - | - | - | 3×1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Valeo-BP 35/60 (2 speed) |
- | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | plastic | no | no | - | - | 0.14 | 63 | 36* | 50 | - | II | Exhaust | - | 25 | +50 | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 18 | - | - | - | - | IP55 | - | - | - | - | - | - | 3×1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Tower-H 250 4E | 230 | Inline | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 0.23 | 820 | - | 50 | 1440 | - | Exhaust | 12.1 | 48 | -25…+50 | – | IPX4 | 1 | 46 | - | - | - | - | - | - | - | - | - | - | - | 228 | - | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
Helix 250х140 4E | 230 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | polymer-coated steel | no | yes | no | - | 2.48 | 2000 | - | 50 | 1310 | - | Exhaust, Supply | 15.5 | 570 | -40 +70 | - | IPX4 | - | 60 | - | - | - | - | - | - | - | - | - | - | - | 556 | - | - | - | - | IP44 | - | - | - | - | - | - | - | - |
Tower-V 400 4Е | 230 | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 2.00 | 3950 | - | 50 | 1440 | - | Exhaust | 33 | 457 | -30…+60 | - | IPX4 | 1 | 55 | - | - | - | - | - | - | - | - | - | - | - | 1097 | - | 2018 | - | - | IP54 | - | - | - | - | - | - | - | - |
CIVIC EC LBE2 1200 S21 V.2 | 400 | floor mounting | - | - | - | polymer-coated steel | yes | - | - | electric preheating, electric reheating | - | 1240 | - | 50/60 | - | - | Supply and exhaust | 363 | - | - | – | - | 3 | 30 | counter-flow | polystyrene | -25...+40 | 400 | - | 40 mm mineral wool | 84…96* | 40 | - | 345 | 2110 | 344 | - | - | - | - | - | 2.3 | 18.7 | - | 3150 | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | Heat recovery efficiency is specified in compliance with EN 13141-8 |
Tower-H EC 225 | 230 | for roof | centrifugal | - | for round air ducts, for square air ducts | polymer-coated steel | yes | yes | no | - | 0.80 | 1290 | - | 50/60 | 2400 | - | Exhaust | - | 101 | -25...+60 | – | IPX4 | 1 | 47 | - | - | - | - | - | - | - | - | - | - | - | 358 | 8 | 2018 | - | - | IP55 | - | - | - | - | - | - | - | - |
S-Vent 450х203-4.0-6D | 400 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | polymer-coated steel | no | yes | no | - | 9.1 | 11150 | - | 50 | 950 | - | Exhaust, Supply | 76.5 | 4000 | +60 | - | IP54 | 3 | 76 | - | - | - | - | - | - | - | - | - | - | - | 3097 | - | - | - | - | IP54 | - | - | - | - | - | - | - | - |
Axis-QA 200 50 Hz |
220-240 | wall mounting | axial | 200 | for round air ducts | polymer-coated steel | no | no | no | - | - | 390 | - | 50 | 1410 | - | Exhaust, Supply | - | 33 | -30 … +40 | - | IPX4 | 1 | 33 | - | - | - | - | - | - | - | - | - | - | - | 108 | 2.82 | - | - | - | IP44 | - | - | 0.23 | - | - | - | - | - |
Axis-QA 200 60 Hz |
220-240 | wall mounting | axial | 200 | for round air ducts | polymer-coated steel | no | no | no | - | - | 450 | - | 60 | 1654 | - | Exhaust, Supply | - | 36 | -30 … +40 | - | IPX4 | 1 | 33 | - | - | - | - | - | - | - | - | - | - | - | 125 | 2.82 | - | - | - | IP44 | - | - | 0.23 | - | - | - | - | - |
Helix 180х92 4Е | 230 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | polymer-coated steel | no | yes | no | - | 0.7 | 800 | - | 50 | 1465 | - | Exhaust, Supply | 7.1 | 160 | -25 +45 | B | IPX4 | - | 62 | - | - | - | - | - | - | - | - | - | - | - | 222 | - | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
Tower-HC EC 310 A | 230 | for roof | centrifugal | - | for round air ducts, for square air ducts | aluminium | yes | yes | no | - | 1.79 | 2700 | - | 50/60 | 2600 | - | Exhaust | - | 408 | -25…+60 | – | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | 750 | 12 | 2018 | - | - | IP55 | - | - | - | - | - | - | - | - |
Axis-Q 450 4D 50 Hz |
400 | wall mounting | axial | 450 | for round air ducts | polymer-coated steel | no | no | no | - | - | 5280 | - | 50 | 1360 | - | Exhaust, Supply | - | 250 | - | - | IPX4 | 3 | 56 | - | - | - | - | -30...+60 | - | - | - | - | - | - | 1467 | 10.5 | - | - | - | IP54 | - | - | 0.6 | - | - | - | - | - |
Axis-Q 450 4D 60 Hz |
400 | wall mounting | axial | 450 | for round air ducts | polymer-coated steel | no | no | no | - | - | 5350 | - | 60 | 1620 | - | Exhaust, Supply | - | 275 | - | - | IPX4 | 3 | 56 | - | - | - | - | -30...+50 | - | - | - | - | - | - | 1486 | 10.5 | - | - | - | IP54 | - | - | 0.65 | - | - | - | - | - |
Tower-H 400 4Е | 230 | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 2.00 | 3950 | - | 50 | 1400 | - | Exhaust | 35 | 457 | -30…+60 | - | IPX4 | 1 | 55 | - | - | - | - | - | - | - | - | - | - | - | 1097 | - | 2018 | - | - | IP54 | - | - | - | - | - | - | - | - |
S-Vent 355x143-4.0-4D | 400 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | polymer-coated steel | no | yes | no | - | 8.7 | 8150 | - | 50 | 1410 | - | Exhaust, Supply | 51 | 4000 | +60 | - | IP54 | 3 | 79 | - | - | - | - | - | - | - | - | - | - | - | 2264 | - | - | - | - | IP54 | - | - | - | - | - | - | - | - |
Axis-QR 710 6D | 400 | wall mounting | axial | 710 | for round air ducts | polymer-coated steel | no | no | no | - | - | 15440 | - | 50 | 830 | - | Exhaust, Supply | - | 1150 | - | - | IPX4 | 3 | 63 | - | - | - | - | -30...+60 | - | - | - | - | - | - | 4289 | 31.0 | - | - | - | IP44 | - | - | 2.0 | - | - | - | - | - |
Tower-AM 315 | 230 | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 1.34 | 1880 | - | 50 | 2720 | - | Exhaust | 12.3 | 296 | -25…+45 | - | IPX4 | - | 54 | - | - | - | - | - | - | - | - | - | - | - | 522 | - | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
Tower-HC EC 250 | 230 | for roof | centrifugal | - | for round air ducts, for square air ducts | polymer-coated steel | yes | yes | no | - | 1.25 | 1500 | - | 50/60 | 3310 | - | Exhaust | - | 164 | -25...+60 | – | IPX4 | 1 | 54 | - | - | - | - | - | - | - | - | - | - | - | 417 | 8 | 2018 | - | - | IP55 | - | - | - | - | - | - | - | - |
Axis-Q 250 4D 50 Hz |
400 | wall mounting | axial | 250 | for round air ducts | polymer-coated steel | no | no | no | - | - | 850 | - | 50 | 1400 | - | Exhaust, Supply | - | 60 | - | - | IPX4 | 3 | 38 | - | - | - | - | -30...+60 | - | - | - | - | - | - | 236 | 3.5 | - | - | - | IP44 | - | - | 0.17 | - | - | - | - | - |
Axis-Q 250 4D 60 Hz |
400 | wall mounting | axial | 250 | for round air ducts | polymer-coated steel | no | no | no | - | - | 885 | - | 60 | 1750 | - | Exhaust, Supply | - | 89 | - | - | IPX4 | 3 | 38 | - | - | - | - | -30...+50 | - | - | - | - | - | - | 246 | 3.5 | - | - | - | IP44 | - | - | 0.22 | - | - | - | - | - |
Tower-V 310 4D (60 Hz) | 400 | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 0.32 | 2442 | - | 60 | 1550 | - | Exhaust | 19 | 202 | -25…+50 | - | IPX4 | 3 | 48 | - | - | - | - | - | - | - | - | - | - | - | 678 | - | – | - | - | IP54 | - | - | - | - | - | - | - | - |
Tower-V 310 4D (50 Hz) | 400 | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 0.29 | 2300 | - | 50 | 1410 | - | Exhaust | 19 | 155 | -25…+50 | - | IPX4 | 3 | 47 | - | - | - | - | - | - | - | - | - | - | - | 639 | - | 2018 | - | - | IP54 | - | - | - | - | - | - | - | - |
CIVIC EC LBE 300-E S21 V.2 | 230 | floor mounting | - | - | - | polymer-coated steel | yes | - | - | electric preheating | - | 320 | - | 50/60 | - | - | Supply and exhaust | 101 | - | - | A | - | 1 | 37 | counter-flow | enthalpy | -25...+40 | 200 | - | 40 mm mineral wool | 73...89* | 47 | - | 96 | - | 89 | - | - | - | - | - | 0.75 | 7 | - | 1050 | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | Heat recovery efficiency is specified in compliance with EN 13141-8 |
Axis-QR 400 4D 50 Hz |
400 | wall mounting | axial | 400 | for round air ducts | polymer-coated steel | no | no | no | - | - | 3740 | - | 50 | 1380 | - | Exhaust, Supply | - | 180 | - | - | IPX4 | 3 | 54 | - | - | - | - | -30...+60 | - | - | - | - | - | - | 1039 | 8.5 | - | - | - | IP44 | - | - | 0.47 | - | - | - | - | - |
Axis-QR 400 4D 60 Hz |
400 | wall mounting | axial | 400 | for round air ducts | polymer-coated steel | no | no | no | - | - | 3870 | - | 60 | 1625 | - | Exhaust, Supply | - | 195 | - | - | IPX4 | 3 | 54 | - | - | - | - | -30...+50 | - | - | - | - | - | - | 1075 | 8.5 | - | - | - | IP44 | - | - | 0.55 | - | - | - | - | - |