Blauberg CIVIC EC LBE2 1200 S21 V.2


The CIVIC EC LB V.2 units are designed for singleroom ventilation of schools, offices and other public and commercial premises. Air flow up to 1240 m³/h.
EAN codeEAN
  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Designation key
  • Dimensions
  • Accessories
  • Additional characteristics
Description
Description
FEATURES

The CIVIC EC LB V.2 units are designed for single-room ventilation of schools, offices and other public and commercial premises. Offer the ideal simple and efficient ventilation solutions for existing and renovated buildings and require no layout of air ducts.Efficient supply and extract ventilation for separate premises.

EC motors with low energy consumption.Low-noise operation.Simple mounting.

DESIGN MOTORS

Made of high-quality polymer coated steel, internally lined with heatand sound insulation of mineral wool, cellular synthetic rubber or other materials.Built-in preheater and reheater modifications available for cold climate conditions.

High efficient electronically commutated motors with external motor and impeller with forward curved blades. Such motors are the most state-of-the-art energy saving solution.EC motors are featured with high performance and total speed controllable range. High efficiency reaching 90 % is the premium advantage of the electronically commutated motors.

AIR FILTRATION CONTROL AND AUTOMATION

Exhaust cassette filter: ISO Coarse >60 % (G4).Supply cassette filter: ISO ePM1 60 % (F7).

The CIVIC EC LB… S21 V.2 units are equipped with an integrated automation system.The S21 controller allows integrating the unit into the BMS (Building Management System).The unit can be controlled by the Blauberg Home mobile application via Wi-Fi.

Download
the Blauberg Home
app for Android
Download
the Blauberg Home
app for iOS
BYPASS

The units are equipped with a bypass. The bypass damper opens for free cooling ventilation mode in summer.

AIR DAMPERS

The automatic supply and extract air dampers are used to prevent uncontrollable air draughts during the unit standstill.

HEATERS AUTOMATION FUNCTIONS

PREHEATING

CIVIC EC LBE V.2 and CIVIC EC LBE2 V.2 units are equipped with an electric preheater which protects the heat exchanger from freezing.

REHEATING

CIVIC EC LBE2 V.2 units feature an electric reheater to raise the supply air temperature.


Functions

CIVIC EC LB… S21

Unit control via Wi-Fi using the mobile application +
Unit control via remote control panel
S22 control panel (option)
Unit control via remote wireless control panel
S22 Wi-Fi control panel (option)
Unit control via a wired remote LCD control panel
S25 control panel (option)
BMS (Building Management System)  RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
Speed switch +
Filter replacement indication by filter timer
Alarm indication full alarm description in the mobile application
Week scheduled operation +
Bypass automatic
manual
Timer +
Boost mode +
Fireplace mode +
Freeze protection using cyclical stops of the supply fan
using preheating (option)
Reheater connection option
Cooler connection option
Minimum supply air temperature control +
Humidity control option
CO₂ control option
VOC control option
PM2.5 control option
Fire alarm sensor connection option

Option: the functionality is available when purchasing the appropriate accessory (see the "Accessories" section)

HEAT EXCHANGER

The CIVIC EC LB V.2 unit has a counter-flow heat exchanger made of polystyrene.

  • In cold season the heat energy of the extract air flow is absorbed by intake air flow, thus decreasing the heat losses caused by ventilation. Condensate generated during heat recovery is collected in a drain pan and removed to the sewage system.
  • In warm season the heat of the outdoor air is absorbed by extract air flow. This way the supply air temperature decreases and heat recovery reduces operation loads for the air conditioner.

The CIVIC EC LB... -E V.2 unit is equipped with a counter-flow heat exchanger made of enthalpy membrane.

  • In cold season the heat and moisture of the extract air are absorbed by supply air through the enthalpy membrane, thus decreasing the heat losses caused by ventilation.
  • In warm season the heat and humidity of the outdoor air is absorbed by extract air flow through the enthalpy membrane. This way the supply air temperature and humidity decreases and heat recovery reduces operation loads for the air conditioner.
FUNCTIONING

Cold outside air flows through the filters and heat exchanger and is moved to the room with a supply centrifugal fan.

Warm polluted air from the premise flows through the filter and the heat exchanger and is exhausted outside with an extract centrifugal fan through an air duct in the wall.

Characteristics
Characteristics
Parameter CIVIC EC LBE2 1200 S21 V.2 Measurement unit
Voltage 400 V
Phase 3 ˜
Frequency 50/60 Hz
Reheater power consumption 2110 W
Max. unit current without electric heater 2.3 A
Max. unit current with electric heater 18.7 A
Preheater power consumption 3150 W
Maximum air flow 1240 m³/h
Max. unit power without an electric heater 345 W
Maximum air flow 344 l/s
Sound pressure level at a distance of 1 m 40 dBА
Sound pressure level at 3 m 30 dBА
Transported air temperature -25...+40 °С
Insulation 40 mm mineral wool mm
Heat recovery efficiency 84…96* %
EC motor yes -
Heat exchanger type counter-flow -
Functions Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection -
Heat exchanger material polystyrene -
Connected air duct diameter 400 mm
Heating electric preheating, electric reheating -
Casing material polymer-coated steel -
Type Supply and exhaust -
SEC class -
Weight 363 kg
Mounting floor mounting -
* Heat recovery efficiency is specified in compliance with EN 13141-8 -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
S21 - user's manual (pdf 611.32Kb)
Modbus table for connecting S21 automation to BMS - user's manual (pdf 137.99Kb)
CIVIC EC LB 1200 V.2 - user's manual (pdf 3.3Mb)
AH CIVIC EC LB - installation instruction (pdf 903.62Kb)
CIVIC EC LB V.2 - data sheet (pdf 1.41Mb)
CIVIC EC LB 1200 V.2 - image (png 314.17Kb)
Designation key
Designation key
Model Motor type Mounting Bypass Heater Drain pump Rated air flow [m³/h] Heat exchanger type Service side (for Civic...1200) Control Modernization
CIVIC EC: synchronous electronically commutated motor L: floor mounting B: with bypass

_: without heater
E:
preheating
E2:
preheating + reheating

_: without drain pump
CP: with drain pump

300; 500; 1200 _: heat recovery
-E: energy recovery
L: Left
R:
Right
S21
V.2: second modernized generation
Dimensions
Dimensions

 

Model Dimensions [mm]
D H H1 H2 H3 H4 L L1 W W1
CIVIC EC LBE2 1200 V.2 400 2000 2106 545 1110 70 535 265 1900 1951
Accessories
Accessories
  Civic EC LB... 1200 S21 V.2
Outer ventilation hood made of brushed stainless steel AH Civic 1200 LB chrome 
Outer ventilation hood made of white coated steel AH Civic 1200 LB white 
Extract filter ISO Coarse >60 % (G4) FP 450x395x48 G4
Supply filter ISO ePM1 60 % (F7) FP 540x450x48 F7 
Control panel S22
Wi-Fi control panel S22 Wi-Fi
LCD Control panel S25
VOC sensor DPWQ30600 
CO₂ sensor DPWQ40200
Humidity sensor DPWC11200
CO₂ sensor with indication CD-1
CO₂ sensor CD-2
CO₂ sensor CD-3
Internal humidity sensor  FS2
Humidity sensor HR-S
Syphon kit SFK 20x32
Drain pump CP-2
Additional characteristics
Additional characteristics
Point Total power of the unit [W] Total sound pressure level at 3 m (1 m) [dBA]
1 315 30 (40)
2 321 -
3 311 30 (40)
4 308 26 (36)
5 122 15 (25)
6 121 -
7 120 -
8 118 -
9 24 11 (21)
10 23 -
11 22 -

 

Sound power level,
A-weighted
Total Octave frequency band [Hz] LpA, 3 m LpA, 1 m 
63 125 250 500 1000 2000 4000 8000
LwA to environment @ point 1 [dBA] 50 31 35 40 37 36 36 28 17 30 40
LwA to environment @ point 5 [dBA] 47 27 31 33 29 30 27 22 13 26 36
LwA to environment @ point 9 [dBA] 32 21 27 21 25 17 19 24 16 11 21