Maximum air flow up to 304 m³/h.
Heat recovery efficiency up to 84 %.
- Description
- Characteristics
- Capacity diagram
- Downloads
- Designation key
- Dimensions
- Additional characteristics
- Accessories
FEATURES
Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings. Heat recovery minimizes ventilation heat losses during the cold season and reduces air conditioner load during the hot season. Controllable air exchange for creating the best suitable indoor microclimate. Compatible with round 125 mm air ducts. DESIGNThe casing is made of expanded polypropylene (EPP) with high heat- and sound-insulating properties. Reneo S 210 / 270 R – right-handed unit. FANSThe unit is equipped with high-efficiency EC external rotor motors and centrifugal impellers with forward-curved blades. |
AIR FILTRATION
Two built-in Coarse 90% (G4) filters provide efficient supply air filtration. Supply ePM1 65% (F7) filter available as an option. BYPASSThe Reneo S units are equipped with a bypass, which can be opened if there is a need to cool down the ventilated area with cool intake air. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RENEO S 210 / 270 L | RENEO S 210 / 270 R | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
HEAT RECOVERY
The units are designed for suspended ceilling and floor mounting. |
CONTROL AND AUTOMATION
Reneo S S21 units are equipped with an integrated automation system. The remote control panel is not included in the delivery set. The S21 controller allows to integrate the unit into the Smart Home system or BMS (Building Management System). Unit control is done via Wi-Fi using the mobile application Blauberg Home.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AUTOMATION FUNCTIONS | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Parameter | Reneo S 270-E R S21 | Measurement unit |
---|---|---|
Voltage | 230 | V |
Phase | 1 | ˜ |
Frequency | 50/60 | Hz |
Max. unit power | 176 | W |
Max. power without electric heater | 176 | W |
Max. unit current without electric heater | 1.34 | A |
Max. unit current | 1.34 | A |
Maximum air flow | 304 | m³/h |
Sound pressure level at 3 m | 37 | dBА |
Transported air temperature | -25...+40 | °С |
Insulation | 25 mm | mm |
Extract filter | G4 / Coarse > 60 % | - |
Supply filter | G4 / Coarse > 60 % (option: F7 / ePM1 60 %) | - |
Heat recovery efficiency | 84 | % |
EC motor | yes | - |
Heat exchanger type | counter-flow | - |
Heat exchanger material | enthalpy | - |
Connected air duct diameter | 125 | mm |
Weight | 22 | kg |
Casing material | expanded polypropylene | - |
SEC class | A | - |
Mounting | ceiling mounting, floor mounting | - |
- Selection method:
- Air capacity:
- Pressure:
- Air capacity: --
- Pressure: ---
Series | Casing type | Heater | Nominal size | Modification | Heat exchanger type | Unit version | Controller type | |
Reneo | S: vertical | _: w/o heater | 27: nominal airflow | 0: standard | – | E: energy recovery | R: right-handed | S21 |
Model | Overall dimensions [mm] | ||||||
Ø D | H | H1 | L | L1 | W | W1 | |
Reneo S 270-E R S21 | 125 | 852 | 909 | 419 | 160 | 600 | 273 |
|
Reneo S 270-E R S21 | ||
G4 panel filter | FP 356x100x48 Coarse 90% G4 | |
F7 panel filter | FP 356x100x48 ePM1 60% F7 | |
LCD control panel | S25 | |
Control panel | S22 | |
Wireless control panel | S22 Wi-Fi | |
Internal humidity sensor | FS2 | |
Internal CO2 sensor | CD-3 | |
CO2 sensor with indication | CD-1 | |
CO2 sensor | CD-2 | |
Humidity sensor | HR-S | |
Electric preheater | EVH 125 S21 V.2 | |
Electric reheater | ENH 125 S21 V.2 | |
Silencer | SD 125 | |
Air damper | VKA 125 | |
Electric actuator | TF230 |