Blauberg Vento Eco A50-4 S Pro
- Description
- Characteristics
- Downloads
- Designation key
- Technical data
- Overall dimensions
- Accessories
FEATURES | |
Arrangement of efficient energy-saving supply and exhaust single-room ventilation in flats, houses, cottages, social and commercial premises. Air purification with optional F8 filter PM2.5 > 99 %. Protection from outdoor noise. Reducing heat losses caused by ventilation due to heat recovery. Humidity balance and regulated air exchange create individually controlled microclimate. |
|
DESIGN | |
HEAT AND HUMIDITY REGENERATION | |
UNIT OPERATING LOGIC IN WINTER PERIOD |
|
Warm stale air is extracted from the premise, flows through the ceramic regenerator and transfers its heat energy and moisture to it. As the ceramic regenerator gets warmed up, the unit switches to the supply mode. |
Clean cold intake air flows through the regenerator and absorbs accumulated heat and humidity. When the ceramic regenerator is cooled down, the unit switches to the extract air mode. |
CONTROL | |
Control of the unit operation mode is performed by means of the sensor control panel. |
One control panel with sensor buttons can control up to two units. Low voltage (12 V) power supply between control panel and Vento Eco units. |
MOUNTING | |
The unit is designed for through-the-wall installation inside a prepared hole in an outer wall of the building. |
One unit is able to ventilate a room up to 25 m2. For bigger rooms two or more units must be installed. |
Parameter | Vento Eco A50-4 S Pro (1 speed) | Vento Eco A50-4 S Pro (2 speed) | Vento Eco A50-4 S Pro (3 speed) | Measurement unit |
---|---|---|---|---|
Voltage | 100-240 | 100-240 | 100-240 | V |
Frequency | 50/60 | 50/60 | 50/60 | Hz |
Current | 0.017 | 0.025 | 0.041 | A |
Power | 1.00 | 2.10 | 4.30 | W |
Air flow in ventilation mode | 15 | 30 | 50 | m³/h |
RPM | 915 | 1555 | 2330 | min-1 |
Air flow in ventilation mode | 4 | 8 | 14 | l/s |
Air flow in heat recovery mode | 8 | 15 | 25 | m³/h |
Air flow in heat recovery mode | 2 | 4 | 7 | l/s |
SFP | 0.48 | 0.50 | 0.62 | W/l/s |
Sound pressure level at 1 m in accordance with ISO 3741:2004 | 21 | 27 | 29 | dBА |
Sound pressure level at 3 m in accordance with ISO 3741:2004 | 12 | 18 | 20 | dBА |
Transported air temperature | 20(-30**) … +40 | 20(-30**) … +40 | 20(-30**) … +40 | °С |
Ingress protection rating | IP24 | IP24 | IP24 | - |
Filter | G3 (Option: F8 PM2,5 > 99 %*) | G3 (Option: F8 PM2,5 > 99 %*) | G3 (Option: F8 PM2,5 > 99 %*) | - |
EC motor | yes | yes | yes | - |
Remote control panel | Sensor | Sensor | Sensor | - |
Functions | Filter replacement indication, Timer | Filter replacement indication, Timer | Filter replacement indication, Timer | - |
Air duct | 160 | 160 | 160 | - |
Outdoor sound pressure attenuation in accordance with DIN EN 20140 | 41 | 41 | 41 | dBА |
Mounting | wall mounting | wall mounting | wall mounting | - |
Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8 | S3*** | S3*** | S3*** | - |
Indoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8 | D1 | D1 | D1 | - |
Heat recovery efficiency in accordance with DIBt LÜ-A 20 | up to 92 | up to 92 | up to 92 | % |
* | Maximum air flow 40 m³/h | Maximum air flow 40 m³/h | Maximum air flow 40 m³/h | - |
** | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | - |
*** | At III speed | At III speed | At III speed | - |
Model | Air duct | Rated air flow [m³/h] | Internal grille type | Ventilation hood type | Control |
Vento Eco | A: round air duct | 50 | -4 |
S11:plastic hood for standard walls |
Pro: sensor control panel |
|
Name | Description | |
Completion Kit VENTO Eco A50-4 |
Indoor grille and cartridge with heat regenerator, fan and G3 filters |
|
ZL1 Vento 160/150 |
Cartridge with heat regenerator for cold climate |
|
FP Vento Eco A50 G3 |
G3 filters (2 pcs.) |
|
FP Vento Eco A50 F8 |
G2 + F8 filters (1 pc.). Filtration rate PM2.5 > 99 %.
Combination of G2 + F8 filters reduces air flow down to 40 m³/h
|
|
AH-8 white 160 |
White painted aluminium outer ventilation hood with frost protection for a cold climate |
|
AH-8 chrome 160 | Brushed stainless steel outer ventilation hood with frost protection for a cold climate | |
AH-10 *colour* 160 | Plastic outer ventilation hood. Available in colours:
|
|
AH-10 chrome 160 | Plastic outer ventilation hood with a plate with brushed stainless steel effect finish | |
AH-11 *colour* 160 | Plastic outer ventilation hood. Available in colours:
|
|
AH-S chrome 160 | Outer ventilation hood for thin wall made of brushed stainless steel | |
AH-S white 160 | Outer ventilation hood for thin wall made of stainless steel, painted white | |
PP 160/0.5 | Outer plastic ventilation hood for mounting from inside | |
KIT BlauPlast white 160 | Kit for angular mounting with white color grille (for walls with standard thickness) | |
KIT BlauPlast chrome 160 | Kit for angular mounting with stainless steel outer grille (for walls with standard thickness) | |
R 160-500 | 500 mm air duct and plastic foam plug | |
R 160-700 | 700 mm air duct and plastic foam plug | |
SE Vento Eco A50 Pro | Sensor control panel |