Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy

Blauberg Axis-P / Axis-FP 1400-1600

Axis-P / Axis-FP 1400-1600
Axis-P / Axis-FP 1400-1600
zoom

Medium pressure axial fans 1400 and 1600 mm series.
  • Description
  • Downloads
  • Aerodynamic parameters
Description
Description
USE  

The fans are used:

  • as a part of a smoke extraction system for air pressurization to create a positive air pressure differential in stairway enclosures, airlock vestibules and lift shafts, to prevent spreading of smoke in premises, protect people using evacuation routes from fire hazards and enable conditions for fire-extinguishing measures.
  • for extraction of smoke in case of fire and removal of hot air outside.
  • in general ventilation systems in industrial, administrative and residential buildings.

Air flow
50 Hz:
4 poles – up to 294 000 m³/h
6 poles – up to 236 000 m³/h60 Hz:
6 poles – up to 256 000 m³/h
8 poles – up to 218 000 m³/h

Pole number: 4, 6, 8, 4/6, 4/8

Motor power50 Hz:
4 poles – up to 132 kW
6 poles – up to 75 kW8 poles – up to 55 kW60 Hz:
6 poles – up to 90 kW
8 poles – up to 75 kW

DESIGN IMPELLER

The metal casing with rolled flanges helps achieve outstanding rigidity and minimum clearances between the casing and the blades.There is an inspection hatch in the casing for easy maintenance.All the casing components are powder coated for improved protection against the environmental effects.The fan casing can be hot-dip galvanized on request.The fan can be equipped both with a standard and a shortened casing.

Aerodynamic impeller blades ensure high efficiency of the fan while keeping noise well under control.The impellers are dynamically balanced.Low weight and low moment of the impeller inertia help reduce the fan start-up time.The fan blades can be made of the following materials:

  • PAG – fiberglass reinforced polyamide for pressurization fans
  • AL – die-cast aluminium for pressurization and smoke extraction fans
  • ST – steel for smoke extraction fans

For smoke extraction fans, only impellers made of die-cast aluminium or steel are used, capable of operating according to the selected fire resistance class of the unit.Please confirm the blade material while placing your order.

  
OPERATION TEMPERATURES

The fans are rated for continuous operation at ambient air temperatures from -60 °C up to +50 °C.The fans are able to operate 2 hours at the temperatures +300 °C and +400 °C.The fans with a fire resistance class of 200 °C/2 hours can be produced on special request.

MOTOR MOUNTING

The fans are equipped with three-phase (400 V, 50 or 60 Hz) singlespeed or two-speed electric motors with IE3 energy efficiency class on request.Motor ingress protection rating is IP55.Power of applied electric motors:

  • 4-pole – up to 132 kW, for fan size 1600 – 50 Hz.
  • 6-pole – up to 90 kW, for fan size 1600 – 60 Hz.

The fans can be mounted on any flat surface or directly into a ventilation duct.The units are suitable for both horizontal and vertical configurations.In-duct installation requires flanges to attach the fan to the ductwork.To attach the fan to the floor, a wall or the ceiling use the O-AF carriers (not included as standard, should be purchased separately).The units are suitable for installation on rooftops to provide direct supply of outdoor air to the stairway areas.

COMPLETE SOLUTIONS FOR AXIAL FANS
INSTALLATION EXAMPLE OF AXIAL FANS ON ROOFTOP
FAN INSTALLATION INTO AN AIR DUCT SYSTEM

To ensure a uniform air flow, the fan should be preceded by a straight duct section with a cross-section area equal to half of that of the fan. The length of the duct section should be 3 ÷ 4 D (D is the inner diameter of the fan). The length of the straight duct section downstream of the fan should be 1.5 ÷ 2 D.Reduction of the recommended duct length values results in a drop of the fan pressure and performance. To reduce noise and vibration, use the EVAF-AF flexible joints.

FAN INSTALLATION WITH NO UPSTREAM DUCTING

Axial fans without upstream ducting must be equipped with a VK-AF inlet cone to improve the air flow parameters.

FAN INSTALLATION WITH NO DOWNSTREAM DUCTING

If the axial fan is a terminal device of the ventilation system (i.e. there is no downstream ducting), the unit must be equipped with a diffuser to reduce the air flow velocity and the fan dynamic pressure. Reduction of the air discharge velocity results in a significant reduction of shock losses which are proportional to the square of velocity decrement.The fan should not be equipped with a downstream contractor.

INSTALLATION NEAR BENDS

To install the fan directly downstream of a bend (elbow), use a curved section with a large bending radius or an array of internal guide vanes.

CHANGING DIAMETER INSTALLATION

When changing from a smaller diameter to a larger one use a connector diffuser with the maximum opening angle of 12°.

OBSTRUCTED SPACE INSTALLATION

To ensure normal operation of the fan in an obstructed space, make sure to provide for a sufficient distance between the inlet and outlet flanges and the floor, walls, bulky equipment and obstacles.

Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
Catalogue "Medium pressure axial fans and axial smoke extraction fans (1400 and 1600 mm)" (pdf 1.52Mb)
Axis-P / Axis-FP 1400-1600 - image (png 404.8Kb)
Axis-P 1400-1600 - image (png 511.15Kb)
Axis-FP 1400-1600 - image (png 639.88Kb)
BSI certificate 0086 CPR 784701 "Centro-Jet, Axis-Jet-CI, Axis-FP, Axis-RF" (pdf 1.09Mb)
BSI certificate 2797 CPR 664983 "Centro-Jet, Axis-Jet-CI, Axis-FP, Axis-RF" (pdf 1.16Mb)
Aerodynamic parameters
Aerodynamic parameters

Standard size: 1400, 1600Pole number: 4Frequency: 50 Hz

Standard size: 1400, 1600Pole number: 6Frequency: 60 Hz