Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy

Blauberg Solo A35/A50/A60 S4 Pro R V.2

  • Description
  • Modifications
  • Downloads
  • Technical data
Description
Description
FEATURES

Wall ventilator with heat and energy recovery. Supply clean fresh air to the premises. Control via remote control. Remove stale extract air from the premise.Clean the air of dust and insects. Prevent penetration of excessive humidity and appearance of mould. Protect against outdoor noise.Heat return and ensuring the balance of humidity in the room thanks to the built-in humidity sensor. Reduce the heating costs in winter and air conditioning costs in summer.Low energy demand.

DESIGN  
FAN ENERGY HEAT EXCHANGER

Air is supplied or extracted by a reversible axial fan with EC motor.Due to EC technology the fan is distinguished with low energy demand. The motor has overheating protection and ball bearings for longer service life.

The high-technology ceramic energy heat exchanger with recovery efficiency up to 75 % is used for extract air heat energy recovery and supply air heating.

AIR FILTERS HUMIDITY SENSOR

Two built-in filters with total filter class G3 are used to clean supply and extract air flows. The filters ensure fresh air cleaning of dust and insects and prevent the ventilator parts from soiling. The filters are cleaned either with a vacuum cleaner or flushed with water.

Helps control the level of humidity in the room. When the sensor is activated, if the humidity in the room exceeds the set level, the ventilator switches to the second (higher) speed. The humidity sensor threshold can be adjusted by turning the potentiometer knob with a special plastic screwdriver. The humidity sensor can be switched on and off using the remote control.

OPERATION LOGIC CONTROL

Energy is recovered due to reversing operation of the ventilator, which consists of two cycles: CYCLE I. As warm stale extract air flows through the ceramic heat exchanger, it heats up and moisturizes the heat exchanger. In 60 seconds as the ceramic heat exchanger gets warmed the ventilator automatically switches to Air Supply mode. CYCLE II. Fresh, cold intake air from outside flows through the ceramic heat exchanger, absorbs accumulated moisture and is heated to the room temperature. In 60 seconds as the heat exchanger gets cooled down, the ventilator switches to Air Extract mode and the cycle is renewed.The Air Supply and the Air Extract modes are switched every 60 seconds.

The humidity sensor and speed are controlled by the remote control.

MOUNTING EXAMPLE  
Modifications
Modification name
Solo A35 S4 Pro R V.2
Solo A50 S4 Pro R V.2
Solo A60 S4 Pro R V.2
+
+
+
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
Solo A35/50/60 S4 Pro R (V.2) - user's manual (pdf 2.99Mb)
Solo A35/A50/A60 S4 Pro R V.2 - data sheet (pdf 826.61Kb)
Solo A35/A50/A60 S4 Pro R V.2 - image (png 143.69Kb)
Catalogue "Single-room ventilation for countries with hot and humid climates" (pdf 20.19Mb)
Technical data
Technical data
Parameters Solo A35 S4 Pro R V.2
Speed I II
Voltage [V / 50 (60) Hz] 220-240
Power [W] 2.40 3.70
Current [A] 0.070 0.073
Air flow in ventilation mode [m³/h (l/s)] 30 (8) 46 (13)
SFP [W/l/s] 0.58 0.58
Sound pressure level at 3 m distance [dBA] 21 26
Transported air temperature [°C] -15...+40
Energy recovery efficiency in accordance with DIBt LÜ-A 20 [%] up to 75
Regenerator type Ceramic
SEC class A
Ingress protection rating IP24
Parameters Solo A50 S4 Pro R V.2
Speed I II
Voltage [V / 50 (60) Hz] 220-240
Power [W] 2.30 4.00
Current [A] 0.070 0.075
Air flow in ventilation mode [m³/h (l/s)] 25 (7) 50 (14)
SFP [W/l/s] 0.66 0.58
Sound pressure level at 3 m distance [dBA] 16 29
Transported air temperature [°C] -15...+40
Energy recovery efficiency in accordance with DIBt LÜ-A 20 [%] up to 75
Regenerator type Ceramic
SEC class A
Ingress protection rating IP24
Parameters Solo A60 S4 Pro R V.2
Speed I II
Voltage [V / 50 (60) Hz] 220-240
Power [W] 2.70 6.70
Current [A] 0.083 0.086
Air flow in ventilation mode [m³/h (l/s)] 35 (10) 60 (17)
SFP [W/l/s] 0.56 0.80
Sound pressure level at 3 m distance [dBA] 27 29
Transported air temperature [°C] -15...+40
Energy recovery efficiency in accordance with DIBt LÜ-A 20 [%] up to 75
Regenerator type Ceramic
SEC class A
Ingress protection rating IP24