Blauberg Hybrid Max E ERV
Decentralized unit for the small offices, facilities, classrooms and living spaces. Maximum air flow up to 160 m³/h.
EAN
- Description
- Characteristics
- Capacity diagram
- Downloads
- Automation functions
- Dimensions
- Sound power level
- Energy labeling
- Product range
- Accessories
Description
Description
FEATURES |
|
Efficient decentralized ventilation unit for small offices or conference rooms.Visible ceiling suspended installation.A version with electrical preheater is available for cold climate.Clean air due to the use of an ePM1 70% / F7 filter for supply air filtration.
|
Possibility to connect fresh air inlet and exhaust air ducts at top or back side of the unit. Low noise operation from 16 dB(A) at 3m.High level of comfort due to builtin bypass and air dampers.
|
DESIGN |
|
 |
AIR DISTRIBUTION |
 |
CASING |
BYPASS |
The casing is made of galvanized sheet metal with white painted decorative cover. The contemporary design of the Hybrid Max unit will seamlessly blend into any interior.The unit is heat- and sound-insulated with a 20 mm layer of foam. The service panel is easy to open for filter maintenance. The unit is equipped with two Ø125 mm spigots for fresh air intake and stale air exhaust. The position of the spigots can be changed from horizontal to vertical.
|
The Hybrid Max units are equipped with a bypass for ventilation (air cooling by the cool air from outside).
|
PREHEATING |
The Hybrid Max E S21 units are equipped with an electrical preheater to prevent heat exchanger freezing in the cold climate.
|
AIR DAMPERS |
HEAT RECOVERY |
The Hybrid Max unit is equipped with two automatic air dampers, which close automatically when the unit is off to prevent drafts.
|
The Hybrid Max unit is equipped with a plate counter-flow polystyrene heat exchanger for heat recovery. The unit condensate is collected and drained to the drain pan under the heat exchanger.
|
 |
The Hybrid Max E unit is equipped with an enthalpy plate counter-flow heat exchanger for energy (heat and humidity) recovery. Due to humidity recovery condensate is not generated in the enthalpy heat exchanger.
|

|
The air flows are completely separated in the heat exchanger. Thus smells and contaminants are not transferred from the extract air to the supply air.Heat recovery is based on heat and/or humidity transfer through the heat exchanger plates. In the cold season supply air is heated in the heat exchanger by transferring the heat energy of warm and humid extract air to the cold fresh air. Heat recovery minimizes ventilation heat losses and heating costs respectively.In the warm season the heat exchanger performs reverse and intake air is cooled in the heat exchanger by the cool extract air. That reduces operation load on air conditioners and saves electricity.
|
FANS |
The units feature high-performance, electronically commutated (EC), external rotor motors with forward curved blades. These state-of-the-art units offer excellent energy efficiency. In addition to that, EC motors combine high performance and optimum control over the entire speed range. EC motors have an excellent power efficiency (up to 90 %).
|
CONTROL AND AUTOMATION |
The Hybrid Max S21 units are equipped with an integrated automation system. The remote control panel is not included in the delivery set (sold separately).The S21 controller allows integrating the unit into the Smart Home system or BMS (Building Management System).Unit control via Wi-Fi using the mobile application Blauberg AHU.
 |
 |
 |
Download the Blauberg Home app for Android |
Download the Blauberg Home app for iOS |
The Hybrid Max S14 units are equipped with an integrated automation system and the S14 wall mounted sensor control panel with LED-indication.
|
MOUNTING |
|
 |
Characteristics
Characteristics
Parameter |
1 Speed |
2 Speed |
3 Speed |
Measurement unit |
Voltage |
230 |
230 |
230 |
V |
Phase |
1 |
1 |
1 |
˜ |
Frequency |
50/60 |
50/60 |
50/60 |
Hz |
Integrated electric preheater power |
800 |
800 |
800 |
W |
Max. unit current with electric heater |
4 |
4 |
4 |
A |
Max. unit current without electric heater |
0.5 |
0.5 |
0.5 |
A |
RPM |
2800 |
2800 |
2800 |
min-1 |
Max. unit power without an electric heater |
58 |
58 |
58 |
W |
Maximum air flow |
60 |
90 |
160 |
m³/h |
Sound pressure level LpA to environment at 1 m distance |
25 |
35 |
42 |
dBА |
Operating temperature
|
–25…+40 |
–25…+40 |
–25…+40 |
-
|
Sound pressure level LpA to environment at 3 m distance |
16 |
26 |
32 |
dBА |
Insulation |
20 |
20 |
20 |
mm |
Extract filter |
Coarse 90% / G4 |
Coarse 90% / G4 |
Coarse 90% / G4 |
-
|
Supply filter |
ePM1 70% / F7 (G4 option) |
ePM1 70% / F7 (G4 option) |
ePM1 70% / F7 (G4 option) |
-
|
Heat recovery efficiency |
74-89 |
74-89 |
74-89 |
% |
Humidity recovery efficiency |
47-60 |
47-60 |
47-60 |
% |
Bypass |
yes |
yes |
yes |
-
|
Heat exchanger type |
counter-flow |
counter-flow |
counter-flow |
-
|
Heat exchanger material |
enthalpy |
enthalpy |
enthalpy |
-
|
Connected air duct diameter |
125 |
125 |
125 |
mm |
Weight |
47 |
47 |
47 |
kg |
Casing material |
aluzinc |
aluzinc |
aluzinc |
-
|
Type |
Supply and exhaust |
Supply and exhaust |
Supply and exhaust |
-
|
SEC class |
A |
A |
A |
-
|
Mounting |
ceiling mounting, wall mounting |
ceiling mounting, wall mounting |
ceiling mounting, wall mounting |
-
|
Capacity diagram
Capacity diagram
Documents archieve
Documents archieve
Automation functions
Automation functions
Functions |
Hybrid Max S21 |
Hybrid Max S14 |
Unit control via Wi-Fi using a mobile application |
+ |
– |
Unit control via a wired remote control panel |
S22 control panel (option) |
 |
|
S14 control panel |
 |
|
Unit control via a wireless remote control panel |
|
– |
Unit control via a remote wired LCD control panel |
S25 control panel (option) |
 |
|
– |
BMS (Building Management System) |
RS-485 |
– |
Wi-Fi |
– |
Ethernet |
– |
MODBUS (RTU, TCP) |
– |
Speed selection |
+ |
+ |
Filter replacement indication |
by filter timer |
by filter timer |
Alarm indication |
full alarm description in the mobile application |
– |
Week-scheduled operation |
+ |
– |
Bypass |
automatic |
manual |
manual |
– |
Timer |
+ |
– |
Boost mode |
+ |
– |
Fireplace mode |
+ |
– |
Freeze protection |
through cyclic stops of the supply fan |
through cyclic stops of the supply fan |
through preheating (option) |
– |
Reheater connection |
option |
– |
Cooler connection |
option |
– |
Minimum supply air temperature control |
option |
– |
Humidity control |
option |
option |
CO2 control |
option |
option |
VOC control |
option |
option |
PM2.5 control |
option |
option |
Fire alarm sensor connection |
option |
– |
Sound power level
Sound power level
Sound power level, A-weighted |
Total |
Octave frequency bands [Hz] |
LpA 3 m |
LpA 1 m |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
LwA to environment at 160 m³/h |
53 |
37 |
41 |
41 |
45 |
49 |
40 |
42 |
41 |
38 |
32 |
42 |
LwA to environment at 90 m³/h |
46 |
31 |
37 |
43 |
36 |
35 |
33 |
34 |
33 |
30 |
26 |
35 |
LwA to environment at 60 m³/h |
36 |
32 |
25 |
24 |
25 |
24 |
23 |
23 |
21 |
19 |
16 |
25 |
Sound power level, A-weighted |
Total |
Octave frequency bands [Hz] |
LpA 3 m |
LpA 1 m |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
6300 |
8000 |
10000 |
LwA to environment at 160 m³/h |
53 |
37 |
37 |
35 |
31 |
27 |
23 |
21 |
24 |
25 |
32 |
42 |
LwA to environment at 90 m³/h |
46 |
29 |
29 |
27 |
24 |
21 |
19 |
19 |
23 |
24 |
26 |
35 |
LwA to environment at 60 m³/h |
36 |
18 |
18 |
19 |
17 |
17 |
18 |
19 |
23 |
24 |
16 |
25 |
Energy labeling
Energy labeling
 |
Supplier model identifier and options installed
|
Hybrid Max (E) ERV |
Reference climate |
Cold/Average/Warm |
SEC in [kWh/(m²a)] for each type of climate |
-76.9/-40.2/-16.5 |
SEC Class |
A |
Declared typology |
BVU |
Type of drive installed |
Variable speed |
Type of heat recovery |
Recuperative |
Thermal efficiency* |
78 |
Maximum flow rate in [m³/h] |
160 |
Maximum electric power in [W] |
58 |
Sound power level (LWA) in [dB(A)] |
48 |
Reference flow rate [m³/s] |
0.031 |
Reference pressure difference in [Pa] |
0 |
SPI in [W/m³/h] |
0.232 |
Control factor and typology |
Local demand control |
Internet address |
http://www.ventilation-system.com/ |
*Efficiency according EN13141-7:2010 at reference flow rate
|
Product range
Product range
|
Heat exchanger |
Air dampers |
Preheater |
Bypass |
Hybrid Max S14 |
HRV |
• |
|
• |
Hybrid Max S21 |
• |
|
• |
Hybrid Max E S21 |
• |
• |
• |
Hybrid Max ERV S14 |
ERV |
• |
|
• |
Hybrid Max ERV S21 |
• |
|
• |
Hybrid Max E ERV S21 |
• |
• |
• |