Blauberg KOMFORT EC DBE 550-E R S21


Suspended heat recovery air handling unit.
Maximum air flow up to 608 m³/h.
EAN codeEAN4058448073311
  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Designation key
  • Accessories
  • Dimensions
  • Aerodynamic characteristics
Description
Description
FEATURES

Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings. For controllable mechanical energy saving ventilation systems. Heat recovery minimises ventilation heat losses. Control of air exchange for creating comfortable indoor microclimate. Compatible with round Ø 160, 200, 250, 315, 400 mm air ducts.

DESIGN

The casing is made of double-skinned aluzinc panels, internally filled with 20 mm mineral wool layer for heat and sound insulation. The casing has fixing brackets with vibration absorbing connectors for easy installation. The spigots for connection to the air ducts are located at the side of the unit and are rubber sealed for airtight connection to the air ducts. The service panel ensures easy access to the internals for cleaning, filter replacement and other maintenance operations.

 

FANS

High-efficient external rotor EC motors and centrifugal impellers with backward curved blades are used for air supply and exhaust. EC motors have the best power consumption to air flow ratio and meet the latest demands concerning energy saving and high-efficient ventilation. EC motors are featured with high performance, low noise level and totally controllable speed range. Dynamically balanced impellers.

KOMFORT EC DBE... 300/550/900

HEAT RECOVERY
   
The KOMFORT EC DBE...-E 300/550/900 unit is equipped with an enthalpy plate counter-flow heat exchanger for energy (heat and humidity) recovery. Due to humidity recovery condensate is not generated in the enthalpy heat exchanger.

The air flows are completely separated in the heat exchanger. Thus smells and contaminants are not transferred from the extract air to the supply air. Heat recovery is based on heat and/or humidity transfer through the heat exchanger plates. In the cold season supply air is heated in the heat exchanger by transferring the heat energy of warm and humid extract air to the cold fresh air. Heat recovery minimizes ventilation heat losses and heating costs respectively. In the warm season the heat exchanger performs reverse and intake air is cooled in the heat exchanger by the cool extract air. That reduces operation load on air conditioners and saves electricity.

AIR HEATER

The unit is equipped with an electric heater for operation during cold seasons at low outside temperature. The integrated electric heater is activated to warm up supply air flow if set indoor air temperature may not be reached by means of heat recovery only. Smooth heat output control ensures automatic supply air temperature maintaining. Two integrated overheat protection thermostats, one actuated at +60 °C with automatic restart and the other one actuated at +90 °C with manual restart.

BYPASS

The units are equipped with a bypass for summer ventilation (room cooling by cool air from outside) and heat exchanger freeze protection.

AIR FILTRATION

The built-in G4 supply filter and G4 extract filter provide air filtration. The F7 supply filter (specially ordered accessory) may be used for efficient supply air filtration.

MOUNTING

Ceiling mounting with fixing brackets. The correct mounted unit must provide free condensate collection and drainage as well as good access for servicing and filter replacement. Access for servicing and cleaning the filter: from the right or left side panel, depending on the unit modification.

  CONTROL AND AUTOMATION

The units are equipped with an S21 integrated automation system. The remote control panel is not included in the delivery set (available separately). The S21 controller allows integrating the unit into the Smart Home system or BMS (Building Management System). The unit can be controlled by the Blauberg AHU mobile application via Wi-Fi.

Download
the Blauberg AHU
app for Android

Download
the Blauberg AHU
app for iOS


AUTOMATION FUNCTIONS
Functions Description
Unit control via Wi-Fi using a mobile application +
Unit control via a wired remote control panel
S22 control panel (option)
Unit control via a wireless remote control panel
S22 Wi-Fi control panel (option)
Unit control via a wired remote LCD control panel
S25 control panel (option)
BMS (Building Management System) RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
Blauberg Cloud Server service +
Speed selection +
Filter replacement indication by filter timer
by filter clogging differential pressure switch (only units with DTV)
Alarm indication full alarm description in the mobile application
Week-scheduled operation +
Bypass automatic
manual
Timer +
Boost mode +
Fireplace mode +
Freeze protection through cyclic stops of the supply fan
through preheating (option)
Cooler connection option
Minimum supply air temperature control +
Humidity control option
CO2 control option
VOC control option
PM2.5 control option
Fire alarm sensor connection option

option: function is available when purchasing the appropriate accessory (see the "Accessories" tab).
Characteristics
Characteristics
Parameter KOMFORT EC DBE 550-E R S21 Measurement unit
Voltage 230 V
Phase 1 ˜
Frequency 50/60 Hz
Max. power without electric heater 322 W
Max. power of electric heater 2000 W
Max. unit current without electric heater 2.4 A
Max. unit power with electric heater 2322 W
Max. unit current with electric heater 11.1 A
Max. unit current of electric heater 8.7 A
Maximum air flow 608 m³/h
Maximum air flow 169 l/s
Sound pressure level at 3 m 30 dBА
Insulation 20 mm mineral wool mm
Transported air temperature -25...+40 °С
Extract filter G4 -
Supply filter G4 (Option: F7) -
Heat recovery efficiency 69...87 %
Heat exchanger type counter-flow -
Bypass yes -
Heat exchanger material enthalpy -
Weight 67 kg
Connected air duct diameter 200 mm
Casing material aluzinc -
Type Supply and exhaust -
SEC class A -
Mounting ceiling mounting -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
S21 - user's manual (pdf 611.32Kb)
KOMFORT EC DBE - data sheet (pdf 2.12Mb)
KOMFORT EC DBE S21 - image (png 307.95Kb)
KOMFORT EC DBE 300/550/900 - user's manual (pdf 2.55Mb)
KOMFORT EC DBE 550-E R S21 - energy label (pdf 80.38Kb)
KOMFORT EC DBE 550-E R S21 - specification (pdf 60.31Kb)
Designation key
Designation key
Series   Motor type   Mounting type   Bypass   Heater type   Rated air flow [m³/h]   Heat exchanger type   Service side   Control   Additional elements
KOMFORT   EC: electronically commutated motor   D: suspended mounting, horizontally directed spigots   B: with a bypass   E: electric heater   300; 550; 900; 2000; 3000 _: heat recovery

E: energy recovery
  L: left

R: right
  S21   _: no additional elements

DTV: equipped with a differential pressure switch to control filter contamination
Accessories
Accessories
    KOMFORT EC DBE 550-E R S21
G4 panel filter FP 782x128x20 G4
G4 pocket filter FPT 392x236x27 G4
F7 pocket filter FPT 392x236x27 F7
Control panel S22
Wireless control panel S22 Wi-Fi
LCD control panel S25
Humidity sensor FS2
CO₂ sensor with indication CD-1
CO₂ sensor CD-2
Humidity sensor HR-S
Electric preheater EVH 200 S21 V.2
Silencer SD 200
Backdraft air damper VRV 200
Air damper VKA 200
Electric actuator TF230
Dimensions
Dimensions

Model Overall dimensions [mm]
Ø D B B1 H L L1
KOMFORT EC DBE 550-E R S21 200 827 960 280 1238 1291
Aerodynamic characteristics
Aerodynamic characteristics
Point Unit power [W]
1 294
2 285
3 271
4 109
5 106
6 101
7 34
8 34
9 32

 

Sound power level, A-weighted Total Octave frequency band [Hz] LpA 3 m LpA 1 m
63 125 250 500 1000 2000 4000 8000
LwA to supply inlet [dBA] 69 26 60 68 54 53 48 40 29    
LwA to supply outlet [dBA] 76 27 62 71 66 68 68 66 64    
LwA to exhaust inlet [dBA] 69 26 60 68 54 53 48 40 29    
LwA to exhaust outlet [dBA] 66 24 55 65 53 53 49 41 35    
LwA to environment [dBA] 50 29 40 46 46 38 36 34 36 30 40

Data provided for point 1 of the air flow diagram