Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy

Blauberg Vento Eco Standard Pro


Heat recovery single-room units. Maximum air flow up to 50 m³/h.
EAN codeEAN
  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Designation key
  • Technical data
  • Accessories
Description
Description
FEATURES

Arrangement of efficient energy-saving supply and exhaust single-room ventilation in flats, houses, cottages, social and commercial premises. Air purification with optional F7 filter PM2.5 > 99 %. Protection from outdoor noise. Reducing heat losses caused by ventilation due to heat recovery. Humidity balance and regulated air exchange create individually controlled microclimate.

DESIGN

HEAT AND HUMIDITY REGENERATION

UNIT OPERATING LOGIC IN WINTER PERIOD

Warm stale air is extracted from the premise, flows through the ceramic regenerator and transfers its heat energy and moisture to it. As the ceramic regenerator gets warmed up, the unit switches to the supply mode.

Clean cold intake air flows through the regenerator and absorbs accumulated heat and humidity. When the ceramic regenerator is cooled down, the unit switches to the extract air mode.

CONTROL

Control of the unit operation mode is performed by means of the sensor control panel.

One control panel with sensor buttons can control up to two units. Low voltage (12 V) power supply between control panel and Vento Eco units.

MOUNTING

The unit is designed for through-the-wall installation inside a prepared hole in an outer wall of the building.

One unit is able to ventilate a room up to 25 m². For bigger rooms two or more units must be installed.

Characteristics
Characteristics
Parameter Vento Eco Standard Pro (1 speed) Vento Eco Standard Pro (2 speed) Vento Eco Standard Pro (3 speed) Measurement unit
Voltage 100-240 100-240 100-240 V
Frequency 50/60 50/60 50/60 Hz
Current 0.017 0.025 0.041 A
Power 1.00 2.10 4.30 W
RPM 915 1555 2330 min-1
Air flow in ventilation mode 15 30 50 m³/h
Air flow in ventilation mode 4 8 14 l/s
Air flow in heat recovery mode 8 15 25 m³/h
Air flow in heat recovery mode 2 4 7 l/s
SFP 0.48 0.50 0.62 W/l/s
Sound pressure level at 1 m in accordance with ISO 3741:2004 21 27 29 dBА
Sound pressure level at 3 m in accordance with ISO 3741:2004 12 18 20 dBА
Transported air temperature -20 (-30**)…+40 -20 (-30**)…+40 -20 (-30**)…+40 °С
Filter G3 (Option: F8 PM2,5 > 99 %*) G3 (Option: F8 PM2,5 > 99 %*) G3 (Option: F8 PM2,5 > 99 %*) -
Ingress protection rating IP24 IP24 IP24 -
EC motor yes yes yes -
Remote control panel Sensor Sensor Sensor -
Air duct 160 160 160 -
Outdoor sound pressure attenuation in accordance with DIN EN 20140 41 41 41 dBА
Mounting wall mounting wall mounting wall mounting -
Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8 S3*** S3*** S3*** -
Heat recovery efficiency in accordance with DIBt LÜ-A 20 up to 92 up to 92 up to 92 %
Indoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8 D1 D1 D1 -
* Maximum air flow 40 m³/h Maximum air flow 40 m³/h Maximum air flow 40 m³/h -
** With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied -
*** At III speed At III speed At III speed -
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
Outer ventilation hood with frost protection AH-8 - installation instruction (pdf 1.41Mb)
Vento Eco Standard/Comfort - brochure (pdf 3.3Mb)
Vento Eco Standard Pro - images (png 248.73Kb)
Dimensions
Dimensions

Designation key
Designation key
Model Version Ventilation hood type Control
Vento Eco Standard: monoblock cartrige
Komfort: split cartrige

_: S11 plastic hood for standard walls
S: metal hood for thin walls

_: without control panel
Pro: sensor control panel
Technical data
Technical data
Parameters Vento Eco Standard
Speed 1 2 3
Voltage [V / 50 (60) Hz] 100-240
Power [W] 1.00 2.10 4.30
Current [A] 0.017 0.025 0.041
RPM [min⁻¹] 915 1555 2330
Air flow in ventilation mode [m³/h (l/s)] 15 (4) 30 (8) 50 (14)
Air flow in heat recovery mode [m³/h (l/s)] 8 (2) 15 (4) 25 (7)
SFP [W/l/s] 0.48 0.50 0.62
Filter G3 (Option: F8 PM2,5 > 99 %*)
Transported air temperature [°C] -20(-30**) … +40
Sound pressure level at 1 m according to ISO 3741: 2004 [dBA] 21 27 29
Sound pressure level at 3 m according to ISO 3741: 2004 [dBA] 12 18 20
Outdoor sound pressure attenuation according to DIN EN 20140 [dBA] 41
Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8 S3***
Indoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8 D1
Heat recovery efficiency according to DIBt LÜ-A 20 [%] up to 92
Ingress protection rating IP24
* maximum air flow 40 m3/h
** with ZL1 Vento 160/100 cartridge and AH-8 outer hood applied
*** at III speed
 
Accessories
Accessories
Name   Description
Completion Kit
Vento Eco Standard
 

Indoor grille and cartridge with heat regenerator, fan and G3 filters

Completion Kit
Vento Eco Comfort

Indoor grille and cartridge with heat regenerator, fan G3 filters and F7 filter holder

FP2 Vento G3

G3 filters (2 pcs.)

FP2 Vento G4  
Coarse filter.
Includes:
• Plastic filter holder (1 pc.)
• G4 filter (1 pc.).
FP2 Vento F7  
Coarse filter.
Includes:
• Plastic filter holder (1 pc.)
• F7 filter (1 pc.).
FPC 150x50 G4   G4 coarse filter 
FPC 150x50 F7   F7 fine filter. Filtration rate PM2.5 > 70 % 
AH-8 white 160  

White painted aluminium outer ventilation hood with frost protection for a cold climate

AH-8 chrome 160   Brushed stainless steel outer ventilation hood with frost protection for a cold climate
AH-10 *colour* 160   Plastic outer ventilation hood. Available in colours: 

AH-10 chrome 160   Plastic outer ventilation hood with a plate with brushed stainless steel effect finish
AH-11 *colour* 160 Plastic outer ventilation hood. Available in colours:

AH-S chrome 160   Outer ventilation hood for thin wall made of brushed stainless steel
AH-S white 160 Outer ventilation hood for thin wall made of stainless steel, painted white
PP 160/0.5 Outer ventilation hood for mounting from inside
KIT BlauPlast white 160 Kit for angular mounting with white colour grille (for walls with standard thickness)
KIT BlauPlast chrome 160 Kit for angular mounting with stainless steel outer grille (for walls with standard thickness)
R 160-500   500 mm air duct and plastic foam plug
R 160-700 700 mm air duct and plastic foam plug
SE Vento Eco A50 Pro Sensor control panel