Blauberg VENTO inHome mini M
- Description
- Characteristics
- Downloads
- Designation key
- Overall dimensions
- Energy label
- Accessories
FEATURES | ||
inHome is a brand new dMVHR solutions for newbuild and retrofit single-room applications, offer efficient and cost-effective ventilation. New and stylish design of indoor unit will fit into any interior. Built-in light sensor controls the brightness of the control panel LEDs and activates night mode automatically. |
Built-in humidity sensor allows unit to automatically select the mode, control the humidity level and prevents mold growth. Silent operation, making it perfect for living spaces. High efficiency (up to 95 %) heat recovery to reduce energy costs and helps you save on heating and air conditioning. |
|
DESIGN | ||
Low power consumption, making inHome suitable for continuous operation without significantly impacting energy bills. Remote management through a remote control. Easy to mount through external walls without the need for complex ducting. |
Operation within a network guarantees balanced ventilation. Higher degree of supply air purification can be achieved with an ISO ePM1 60% (F7) filter (optional). Possibility to connect external sensors. Equipped with an automatic shutter to prevent undesired external entry when turned off (optional). |
|
CONTROL
The ventilators can be connected into one network for centralized control. The signals from the control panel, remote control, as well as from the humidity sensor, are received only by the master (main) ventilator. |
||
Control of the unit operation mode is also performed by means of the sensor control panel located on the unit casing or the remote control. |
Vento inHome is equipped with a humidity sensor for indoor humidity control. If humidity increases above a set point, the unit boosts to the speed III. |
|
ENERGY RECOVERY
UNIT OPERATING LOGIC IN WINTER PERIOD |
||
Warm stale air is extracted from the premise, flows through the ceramic heat exchanger and transfers its heat and moisture to it. As the ceramic heat exchanger gets warmed up, the unit switches to the supply mode. |
Clean cold intake air flows through the heat exchanger and absorbs accumulated heat and humidity. When the heat exchanger is cooled down, the unit switches to the extract air mode. |
|
MOUNTING | ||
The unit is designed for through-the-wall installation inside a prepared hole in an outer wall of the building. The best ventilation solution is pairwise installation of reverse phase synchronized units. Some units ensure supply of fresh air to the room and the other units extract air from the premise. This way the most efficient balanced ventilation is arranged. |
In case of brand new construction, units are mounted in two stages:
|
|
Parameter | VENTO inHome mini M (1st speed) |
VENTO inHome mini M (2nd speed) |
VENTO inHome mini M (3rd speed) |
Measurement unit |
---|---|---|---|---|
Speed | I | II | III | - |
Voltage | 100-240 | 100-240 | 100-240 | V |
Frequency | 50/60 | 50/60 | 50/60 | Hz |
Power | 1.0 | 1.6 | 3.0 | W |
Current | 0.02 | 0.03 | 0.04 | A |
Air flow in ventilation mode | 8 | 16 | 25 | m³/h |
Air flow in ventilation mode | 2 | 4 | 7 | l/s |
Air flow in heat recovery mode | 4 | 8 | 13 | m³/h |
Air flow in heat recovery mode | 1 | 2 | 3 | l/s |
SFP | 0.90 | 0.72 | 0.86 | W/l/s |
Sound pressure level at 1 m | 20 | 26 | 33 | dBА |
Sound pressure level at 3 m | 10 | 16 | 23 | dBА |
Transported air temperature | -15...+40 | -15...+40 | -15...+40 | °С |
Filter | ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) | ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) | ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) | - |
Ingress protection rating | IP24 | IP24 | IP24 | - |
Heat recovery efficiency | ≤ 81 | ≤ 81 | ≤ 81 | % |
EC motor | yes | yes | yes | - |
Functions | Filter replacement indication, Timer, Humidity sensor, External sensor connection, Light sensor | Filter replacement indication, Timer, Humidity sensor, External sensor connection, Light sensor | Filter replacement indication, Timer, Humidity sensor, External sensor connection, Light sensor | - |
Air duct | 100 | 100 | 100 | - |
Outdoor sound pressure attenuation in accordance with DIN EN 20140 | 40 / 44 | 40 / 44 | 40 / 44 | dBА |
Mounting | wall mounting | wall mounting | wall mounting | - |
Model | Control | Air duct | Ventilation hood type | Front panel |
Vento inHome / Vento inHome mini |
_: control of the unit operation mode is performed by means of sensor control panel located on the unit casing or a remote controller W: control of the unit operation mode is performed by means of sensor control panel located on the unit casing, remote controller or mobile application via Wi-Fi |
_: integrated automatic air shutters M: without integrated automatic air shutters |
_: white plastic hood AH-11 white 160 (for standard walls) S: metal hood (for thin walls) |
_: white BLK: black |
Vento inHome mini | Description | |
Pre-installation Kit Vento inHome mini | Pre-installation kit for mounting into walls with standard thickness. Includes:
|
|
Pre-installation Kit Vento inHome mini S | Pre-installation kit for mounting into thin walls. Includes:
|
|
Completion Kit Vento inHome mini | Final mounting kit. Includes:
|
|
FP3 Vento G3 | G3 filters (2 pcs.) | |
AH-8 white 100 | White painted aluminium outer ventilation hood with frost protection for a cold climate | |
AH-8 chrome 100 | Brushed stainless steel outer ventilation hood with frost protection for a cold climate | |
AH-10 *colour* 100 | Plastic outer ventilation hood. Available in colours: | |
AH-10 chrome 100 | Plastic outer ventilation hood with a plate with brushed stainless steel effect finish | |
AH-11 *colour* 100 | Plastic outer ventilation hood. Available in colours: | |
AH-S white 100 | Stainless steel ventilation hood, painted white | |
AH-S chrome 100 | Brushed stainless steel ventilation hood | |
KIT BlauPlast white 100 | Kit for angular mounting with white colour grille (for walls with standard thickness) | |
KIT BlauPlast chrome 100 | Kit for angular mounting with stainless steel outer grille (for walls with standard thickness) | |
R 100-500 | 500 mm air duct and polystyrene foam plug | |
R 100-700 | 700 mm air duct and polystyrene foam plug | |
FB Vento Expert A50 | Remote control | |
CD-1 | CO2 sensor with LED CO2 indication and a sensor button for operation mode selection | |
CD-2 | CO2 sensor |