Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Type | Power | SEC class | Ingress protection rating | Sound pressure level at 3 m | Voltage | Maximum air flow | SFP | Weight | Current | LED-light power | * | *** |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Quatro Hi-Tech Gold 125 S | 220-240 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | 0.1 | 16 | 167 | 34* | 50 | 2400 | - | Exhaust | - | - | - | - | - | 46 | 0.34 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Hi-Fi 125 S | 220-240 | - | - | - | - | - | - | - | - | - | 0.11 | 18 | 155 | 32* | 50 | 2200 | - | - | - | - | - | - | - | 43 | 0.42 | 0.75 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Hi-Fi 100 S (220-240V/60Hz) | 220-240 | - | - | - | - | - | - | - | - | - | 0.05 | 8 | 85 | 27* | 60 | 2000 | - | - | - | - | - | - | - | 24 | 0.33 | 0.51 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Tubo 125 T | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | 0.1 | 16 | 195 | 39* | 50 | 2400 | - | Exhaust, Supply | - | - | - | - | - | 54 | 0.3 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero 100 T | 220-240 | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | 0.085 | 14 | 102 | 38* | 50 | 2300 | - | Exhaust | - | - | - | - | - | 28 | 0.49 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Bravo Still 125 T | 220-240 | White | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | 0.006 | 9.3 | 115 | 31* | 50 | - | - | Exhaust | - | - | - | - | - | 32 | 0.29 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Bravo Platinum 125 T | 220-240 | Platinum | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | 0.1 | 16 | 192 | 37* | 50 | 2400 | - | Exhaust | - | - | - | - | - | 53 | 0.3 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ultra 250 Round T | - | - | ceiling mounting | centrifugal | - | 150 | plastic | no | no | no | 0.25 | - | 482 | - | 50 | - | - | Exhaust | 57 | - | IPX4 | 36 | 220-240 | 134 | 0.43 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Still Gold 125 T | 220-240 | Gold | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | 0.059 | 9.4 | 158 | 31* | 50 | - | - | Exhaust | - | - | - | - | - | 44 | 0.21 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Hi-Fi 100 S | 220-240 | - | - | - | - | - | - | - | - | - | 0.05 | 8 | 85 | 27* | 50 | 2000 | - | - | - | - | - | - | - | 24 | 0.33 | 0.51 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Omega 100 S | 220-240 | - | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | 90 | - | 50 | 2165 | - | Exhaust | 8 | - | - | 29 | - | 25 | 0.32 | - | 0.05 | - | - | - |
Quatro Hi-Tech 100 S | 220-240 | Hi-Tech | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | 0.085 | 14 | 88 | 33* | 50 | 2300 | - | Exhaust | - | - | - | - | - | 24 | 0.57 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Still Vintage 150 S | 220-240 | Vintage | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | 19 | 254 | 33 | 50 | - | - | Exhaust | - | - | - | - | - | 71 | 0.27 | - | - | - | - | - |
Ducto-U Plus 125 min | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | 0.065 | 10 | 155 | 29* | 50 | 1950 | min | Exhaust, Supply | - | - | - | - | - | 43 | 0.23 | 0.75 | - | - | - | - |
Ducto-U Plus 125 max | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | 0.085 | 13 | 215 | 33* | 50 | 2250 | max | Exhaust, Supply | - | - | - | - | - | 60 | 0.22 | 0.75 | - | - | - | - |
Auto 125 T | 220-240 | White | wall mounting | axial | 125 | - | - | - | - | - | 0.1 | 22 | 185 | 35* | 50 | 2400 | - | Exhaust | - | - | - | - | - | 51 | 0.43 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ducto 100 T | 220-240 | White | Inline | axial | 100 | - | - | - | - | - | 0.049 | 7.5 | 110 | 25* | 50 | 2100 | - | Exhaust, Supply | - | - | - | - | - | 31 | 0.25 | 0.61 | - | - | - | - |
Line 100 S | 220-240 | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | 0.085 | 14 | 95 | 34* | 50 | 2300 | - | Exhaust | - | - | - | - | - | 26 | 0.53 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Deco 100 T | 220-240 | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | 0.085 | 14 | 105 | 37* | 50 | 2300 | - | Exhaust | - | - | - | - | - | 29 | 0.48 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo DC 110 Light T | 120-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | 0.18 (0.3) | 19 | 187 | 23-25* | 50/60 | 1100 | - | Exhaust | - | B*** | IPX2 | - | - | 52 | 0.37 | 6.4 | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Aero Chrome 125 T | 220-240 | Chrome | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | 0.1 | 16 | 193 | 39* | 50 | 2400 | - | Exhaust | - | - | - | - | - | 54 | 0.3 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Slim 120 S | 220-240 | White | ceiling mounting, wall mounting | axial | 120 | - | - | - | - | - | 0.1 | 17 | 184 | 35* | 50 | 2400 | - | Exhaust | - | - | - | - | - | 51 | 0.33 | 0.73 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Bravo Still Chrome 125 T | 220-240 | Chrome | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | 0.006 | 9.3 | 115 | 31* | 50 | - | - | Exhaust | - | - | - | - | - | 32 | 0.29 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Sileo Design DC 100 T min |
220-240 | - | ceiling mounting, wall mounting | axial | 100 | - | plastic | - | - | - | 0.026 | 1.5 | 58 | 21 | 50/60 | 1850 | - | Exhaust | - | - | - | - | - | 16 | 0.09 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Sileo Design DC 100 T max |
220-240 | - | ceiling mounting, wall mounting | axial | 100 | - | plastic | - | - | - | 0.04 | 2.7 | 93 | 26 | 50/60 | 2650 | - | Exhaust | - | - | - | - | - | 26 | 0.1 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Bravo 150 T | 220-240 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | 0.13 | 24 | 305 | 39* | 50 | 2400 | - | Exhaust | - | - | - | - | - | 85 | 0.28 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Still Chrome 150 T | 220-240 | Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | 0.14 | 19 | 254 | 33* | 50 | - | - | Exhaust | - | - | - | - | - | 71 | 0.27 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |