Search results
Selected 403 products
Mode VoltageMountingDesignConnection diameterAir ductWidthHeightCasing materialEC motorOutdoor mountingSound-insulated casingHeat exchangerHeatingMaximum air flowFrequencyRPMTypePowerMax. operating temperatureSEC classPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialElectric heater powerSound pressure level at 3 mNumber of electrical heating elementsTransported air temperature Electric heater currentCurrentConnected air duct diameterConnected air duct size FilterTransported air temperatureNumber of water coil rowsInsulationHeat recovery efficiencyTotal unit powerVoltageMaximum air flowWeightErPBypassExtract filterSupply filterMax. power without electric heaterMax. unit powerMax. unit current without electric heaterMax. unit currentMax. unit power with electric heaterMax. unit current with electric heaterCurrentMaximum power consumption in "Heat Recovery + Heat Pump"Maximum power consumption in "Heat Recovery"Maximum power consumption in "Heat Recovery + Heat Pump + Pre-Heating"Air-handling unit energy efficiency "Heating" mode (COP)Air-handling unit energy efficiency "Cooling" mode (ERR)CoolantCoolant weightHeat output in "Heating" mode [kW] at t0 = +7 °C; tk = +45 °C*Compressor typeTemperature setting range in "Cooling/Heating"Heat output in "Cooling" mode [W] at t0 = +7 °C; tk = +45 °CFilterElectric heater current Max. power of electric heaterMax. unit current of electric heaterMotor max. powerTransported air temperatureIntegrated electric preheater powerMax. water temperatureWater coil connection diameter
KOMFORT Roto EC LEHP 700 S17 230 - - - - - - aluzinc - - - - - 830 50 - - - - - 1 52 rotary aluminum - - - - - - 250 - - -25…+40 - - 85 - - 231 160 - - G4 G4 (Option: F7) - - - 18.5 - - - 0.94 0.36 3.74 6.5 4.15 R410A 1.6 2.6 Sealed, rotary type +16...+30 2 - - - - - - - - -
KOMFORT Roto EC D650 S18 230 - - - - - - painted steel - - - - - 710 50/60 3600 - - - A 1 36 rotary aluminum - - - - - - 200 - - -25...+40 - 40 mm mineral wool 80–87 - - 197 102 2016, 2018 - G4 G4 + F7 (Option: H13) 367 367 2.5 2.5 - - - - - - - - - - - - - - - - - - - - - - -
Reneo S 210-E L S14 230 ceiling mounting, floor mounting - - - - - expanded polypropylene yes - - - - 255 50/60 - - - - A 1 34 counter-flow enthalpy - - - - - - 125 - - - - 25 mm 83 - - - 20 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 114 114 0.92 0.92 - - - - - - - - - - - - - - - - - - - -25...+40 - - -
BLAUBOX E 400-6 Pro 400 ceiling mounting, wall mounting, floor mounting centrifugal - for round air ducts - - aluzinc no no yes - - 425 50 2705 Supply - - A 3 29 - - 6000 - 3 -25...+40 8.7 - 150 - G4 - - 25 mm mineral wool - - - 118 50 2016, 2018 - - - 98 - 0.43 - 6098 9.13 - - - - - - - - - - - - - - - - - - - - -
KOMFORT Ultra EC S2 300-H S2 white 230 wall mounting, floor mounting - 125 for round air ducts - - - yes no yes - - 300 50/60 - Supply and exhaust 165 - B 1 33 cross-flow polystyrene - - - - - 1.3 - - - -25...+40 - 20 mm mineral wool 55...79 - - 83 32 2016, 2018 - G4 F8, G4 - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC SB 160 S21 230 wall mounting, floor mounting - - - - - polymer-coated steel yes - - - - 200 50/60 - - 57 - A+ 1 24 counter-flow polystyrene - - - - - - 125 - - -25...+40 - 20 mm mineral wool 85...93 - - 56 36 2018 - G4 F7 (option: G4) - - - - - - 0.5 - - - - - - - - - - - - - - - - - - - -
Reneo D 180-E S21 230 ceiling mounting, wall mounting, floor mounting - - - - - EPP yes - - - - 181 50/60 - - 53 45 A 1 29 counter-flow enthalpy - - - - - - 160 - - - - 25 mm 84 - - - 15 - - Coarse 90 % (G4) ePM1 60 % (F7) - - - - - - 0.49 - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC S 401-E L S21 230 - - - - - - painted steel yes - - - - 447 50/60 - - - - A - - Sorption - - 37 - - - - 160 - - -25...+40 - 40 mm mineral wool 85 - - - 70 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 222 222 1.6 1.6 - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC LW 1500-2 S17 230 - - - - - - aluzinc - - - - - 1500 50/60 2000 - - - - 1 62 rotary aluminum - - - - - - 315 - - -25...+40 - 25 mm mineral wool 72–95 - - 417 175 2016, 2018 - G4 G4 - - - - 750 3.2 - - - - - - - - - - - - - - - - 2 items x 222 - - - -
KOMFORT EC SB 350-E S14 230 wall mounting, floor mounting - - - - - polymer-coated steel yes - - - - 450 50/60 - - 178 - A 1 28 counter-flow enthalpy - - - - - - 160 - - -25...+40 - 40 mm mineral wool 73...91 - - 125 64 2018 - G4 F7 (option: G4) - - - - - - 1.4 - - - - - - - - - - - - - - - - - - - -
Reneo-Fit D 100-E S14 230 ceiling mounting - - - - - EPP - - - - - 130 50/60 - Supply and exhaust - - A 1 32 counter-flow enthalpy - - - - - - 100 / 125 - - -23…+40 - 25 mm 73–88 - - 36 8 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) - 45 - 0.34 - - - - - - - - - - - - - - - - - - - - - - -
Reneo SE 350-E L S21 230 ceiling mounting, wall mounting, floor mounting - - - - - expanded polypropylene yes - - - - 410 50/60 - - - 45 A 1 26 counter-flow enthalpy - - - - 4.66 - 160 - - - - 45 mm 83 - - - 26 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 213 1263 1.62 6.28 - - - - - - - - - - - - - - - - - - - - 1050 - -
KOMFORT Ultra S 250-H S1 230 wall mounting, floor mounting - 125 for round air ducts - - aluzinc no no yes - - 250 50/60 - Supply and exhaust 148 - E 1 28...47 cross-flow polystyrene - - - - - 0.78 - - - -25...+40 - 20 mm mineral wool 55...78 - - 69 - 2018 - G4 G4 (option: F8 PM2.5 > 81 %) - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX E 200-1.8 Pro 230 ceiling mounting, wall mounting, floor mounting centrifugal - for round air ducts - - aluzinc no no yes - - 190 50 2830 Supply - - A 1 27 - - 1800 - 3 -25...+40 7.8 - 100 - G4 - - 25 mm mineral wool - - - 53 50 2016, 2018 - - - 73 - 0.32 - 1873 8.12 - - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC D350 S17 230 - - - - - - painted steel - - - - - 430 50/60 3570 - - - A 1 31 rotary aluminum - - - - - - 160 - - -25...+40 - 40 mm mineral wool 72–87 - - 119 81 2016, 2018 - G4 G4 + F7 (Option: H13) 185 185 1.3 1.3 - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC LBE 400-E S21 230 ceiling mounting, floor mounting - - - - - galvanized steel - - - - - 540 50/60 - - - - A 1 27 counter-flow enthalpy 2800 - - - - - 200 - - -25…+40 - 40 mm mineral wool 78–89 - - 150 76 - - G4 G4, F7 289 - 2.1 - 3089 14.3 - - - - - - - - - - - - - 12.2 - - - - - - -
Blaubox EC MW 2000 S31 230 ceiling mounting, wall mounting, floor mounting centrifugal - for rectangular air ducts - - aluzinc yes no - - - 2150 50 - Supply - - - 1 53 - - - - - -30…+40 - - 500 x 300 - - - 4 30 mm mineral wool - - - - 45 2018 - - - - 387 - 1.7 - - - - - - - - - - - - - - Coarce 90% / G4 (option: ePM1 70% / F7) - - - - - - 150 1
KOMFORT Roto EC SE 281 R S21 230 - - - - - - painted steel yes - - - - 382 50/60 - - - - A+ - - Condensing - - 28 - - - - 160 - - -25...+40 - 40 mm mineral wool 89 - - - 67 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 176 1376 1.34 6.66 - - - - - - - - - - - - - - - - 1200 5.32 - - - - -
KOMFORT Roto EC LE 1200-6 S17 400 - - - - - - aluzinc - - - - - 1200 50/60 1930 - - - - 3 60 rotary aluminum 6000 - - - - - 315 - - -25...+40 - 20 mm mineral wool 73–95 - - 333 165 2016, 2018 - G4 G4 - - - - 6570 9.5 - - - - - - - - - - - - - - - - 2 items x 208 - - - -
KOMFORT EC S2B300 S14 230 wall mounting, floor mounting - - - - - polymer-coated steel yes - - - - 330 50/60 3200 - 170 - A+ 1 30 counter-flow polystyrene - - - - - - 160 - - -25...+60 - 20 mm mineral wool 85–93 - - 92 53 2016, 2018 - G4 F7 (option: G4) - - - - - - 1.3 - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 2000 S21 230 ceiling mounting - - - - - aluzinc - - - - - 2100 50/60 - Supply and exhaust - - NRVU 1 36 cross-flow aluminum - - - - - - 315 - - -25...+40 2 25 mm mineral wool 50...67 - - 583 140 - yes G4 G4 - 1063 - 4.7 - - - - - - - - - - - - - - - - - - - - - - -
Reneo S 350 R S21 230 ceiling mounting, wall mounting, floor mounting - - - - - expanded polypropylene yes - - - - 410 50/60 - - - 45 A+ 1 26 counter-flow polystyrene - - - - - - 160 - - - - 45 mm 93 - - - 26 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 213 213 1.62 1.62 - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DW 1200-4 Pro 400 ceiling mounting, wall mounting, floor mounting centrifugal - for rectangular air ducts - - aluzinc no no yes - - 1200 50 2700 Supply - - - 3 51 - - - - - -25...+40 - 0.55 - 400х200 - - 4 50 mm mineral wool - 320 - 333 57 2016, 2018 - - G4 (Option: F7) - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC LHP 400 S18 230 - - - - - - aluzinc - - - - - 520 50 - - - - - 1 45 rotary aluminum - - - - - - 160 - - -10…+40 - - 85 - - 53 150 - - G4 G4 (Option: F7) - - - 4.6 - - - 0.745 0.31 - 6 4 R410A 0.8 1.56 Sealed, rotary type +16...+30 1.2 - - - - - - - - -
KOMFORT Roto EC D250 S18 230 - - - - - - painted steel - - - - - 310 50/60 2200 - - - A 1 21 rotary aluminum - - - - - - 160 - - -25...+40 - 40 mm mineral wool 71–87 - - 86 55 2016, 2018 - G4 G4 + F7 (Option: H13) 135 135 1.0 1.0 - - - - - - - - - - - - - - - - - - - - - - -