Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Heating | Form | Length | Material | Device | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Heat recovery efficiency | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Heat exchanger type | Heat exchanger material | Electric heater power | Transported air temperature | Electric heater current | Current | Connected air duct diameter | Transported air temperature | Insulation | Heat recovery efficiency | Total unit power | Sound pressure level at a distance of 1 m | Operating temperature range | Voltage | Max. unit power without an electric heater | Reheater power consumption | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Extract filter | Supply filter | Air speed | Maximum operating pressure | Motor IP rating | Max. power without electric heater | Max. unit current without electric heater | Max. unit power with electric heater | Max. unit current with electric heater | Current | Preheater power consumption | Filter | Remote control panel | Functions | * | Motor max. power |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Iso-B EC 200 | 230 | - | Inline | centrifugal | 200 | for round air ducts | - | - | galvanized steel | yes | no | yes | - | - | - | - | - | 0.83 | - | 700 | - | 50/60 | 2580 | - | - | - | Exhaust, Supply | - | 101.6 | - | B | IPX4 | 1 | 37 | - | - | - | - | - | - | - | -25...+60 | - | - | - | - | - | - | - | - | 194 | - | - | 2018 | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - |
Tower-H EC 225 | 230 | - | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | - | - | - | - | 0.80 | - | 1290 | - | 50/60 | 2400 | - | - | - | Exhaust | - | 101 | -25...+60 | – | IPX4 | 1 | 47 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 358 | - | 8 | 2018 | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - |
Tubo 125 | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 16 | 195 | 39* | 50 | 2400 | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 54 | 0.3 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-I 50x30 4E 50 Hz |
230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | - | 0.57 | - | 1700 | - | 50 | 1390 | - | - | - | Exhaust, Supply | 37.2 | 140 | - | - | IPX4 | 1 | 48 | - | - | - | - | - | - | - | -25…+45 | - | - | - | - | - | - | - | - | 472 | - | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
Box-I 50x30 4E 60 Hz |
230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | - | 0.73 | - | 1855 | - | 60 | 1530 | - | - | - | Exhaust, Supply | 37.2 | 175 | - | - | IPX4 | 1 | 50 | - | - | - | - | - | - | - | -25…+50 | - | - | - | - | - | - | - | - | 515 | - | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
S-Vent 450х203-4.0-6D | 400 | - | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 9.1 | - | 11150 | - | 50 | 950 | - | - | - | Exhaust, Supply | 76.5 | 4000 | +60 | - | IP54 | 3 | 76 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3097 | - | - | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Box EC 50x30-1 max | 230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | yes | no | - | - | - | - | - | - | - | - | 2700 | - | 50/60 | 3100 | - | - | - | Exhaust, Supply | 18.7 | 553 | - | – | IPX4 | 1 | 51 | - | - | - | - | - | - | - | -25...+50 | - | - | - | - | - | - | - | - | 750 | - | - | 2018 | - | - | - | - | - | IP54 | - | - | - | - | 4.20 | - | - | - | - | - | - |
Axis-Q EC 450 | 230 | - | wall mounting | axial | 465 | for round air ducts | - | - | polymer-coated steel | yes | no | no | - | - | - | - | - | - | - | 7400 | - | 50/60 | 1400 | - | - | - | Supply and exhaust | - | 380 | - | - | IPX5 | 1 | 65 | - | - | - | - | - | - | - | –25…+60 | - | - | - | - | - | - | - | - | 2056 | - | 7.05 | - | - | - | - | - | - | IP55 | - | - | - | - | 1.7 | - | - | - | - | - | - |
KOMFORT Roto EC LW 2000-2 S17 | 230 | - | - | - | - | - | - | - | aluzinc | - | - | - | - | - | - | - | - | - | - | 2250 | - | 50/60 | 3000 | - | - | - | - | - | - | - | - | - | 1 | 64 | rotary | aluminum | - | - | - | - | 500x300 | -25...+40 | 25 mm mineral wool | 68–93 | - | - | - | - | - | - | 625 | - | - | 2016, 2018 | - | G4 | G4 | - | - | - | - | - | 1070 | 5 | - | - | - | - | - | - | 2 items x 448 |
Iso-K 315 4E (50 Hz) | 230 | - | Inline | centrifugal | 315 | for round air ducts | - | - | galvanized steel | no | yes | yes | - | - | - | - | - | 1.84 | - | - | - | 50 | 1475 | - | - | 1970 | Exhaust | - | 304 | -20…+120 | - | IP54 | 1 | 46 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 53.0 | - | 547 | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Iso-K 315 4E (60 Hz) | 230 | - | Inline | centrifugal | 315 | for round air ducts | - | - | galvanized steel | no | yes | yes | - | - | - | - | - | 1.72 | - | - | - | 60 | 1750 | - | - | 2310 | Exhaust | - | 383 | -20…+120 | - | IP54 | 1 | 47 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 53.0 | - | 642 | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Ducto Plus 125 min | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.065 | 10 | 155 | 29* | 50 | 1950 | min | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 43 | 0.23 | 0.75 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ducto Plus 125 max | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.085 | 13 | 215 | 33* | 50 | 2250 | max | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 60 | 0.22 | 0.75 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauFlex Iso N 182/7.6 | - | - | - | - | 182 | for round air ducts | - | - | - | - | - | - | - | round | 7600 | - | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 mm mineral wool | - | - | - | -30...+120 | - | - | - | - | - | - | - | - | - | - | 30 | 3000 | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-QA 200 50 Hz |
220-240 | - | wall mounting | axial | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 390 | - | 50 | 1410 | - | - | - | Exhaust, Supply | - | 33 | -30 … +40 | - | IPX4 | 1 | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 108 | - | 2.82 | - | - | - | - | - | - | IP44 | - | - | - | - | 0.23 | - | - | - | - | - | - |
Axis-QA 200 60 Hz |
220-240 | - | wall mounting | axial | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 450 | - | 60 | 1654 | - | - | - | Exhaust, Supply | - | 36 | -30 … +40 | - | IPX4 | 1 | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 125 | - | 2.82 | - | - | - | - | - | - | IP44 | - | - | - | - | 0.23 | - | - | - | - | - | - |
Quatro Platinum 125 (127-220V/60Hz) | 127 | Platinum | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.119 | 16 | 170 | 35* | 60 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.34 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Platinum 125 (127-220V/60Hz) | 220 | Platinum | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.102 | 15 | 170 | 35* | 60 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.32 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-FI 60x30 6D | 400 | - | Inline | centrifugal | - | for rectangular air ducts | 600 | 300 | galvanized steel | no | no | yes | - | - | - | - | - | 0.78 | - | 2320 | - | 50 | 920 | - | - | - | Exhaust, Supply | - | 397 | - | - | IPX4 | 3 | 41 | - | - | - | - | - | - | - | -20...+70 | - | - | - | - | - | - | - | - | 644 | - | 56 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
Helix 180х92 4Е | 230 | - | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 0.7 | - | 800 | - | 50 | 1465 | - | - | - | Exhaust, Supply | 7.1 | 160 | -25 +45 | B | IPX4 | - | 62 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 222 | - | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
Box-R 200 V2 (1 speed) | 1 ~ 230 | - | Inline | centrifugal | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 0.45 | - | - | - | 50 | 770 | - | - | 460 | Exhaust, Supply | 8.8 | 103 | 50 | C | IPX4 | - | 46 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 128 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 200 V2 (2 speed) | 1 ~ 230 | - | Inline | centrifugal | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 0.63 | - | - | - | 50 | 1200 | - | - | 752 | Exhaust, Supply | 8.8 | 142 | 50 | C | IPX4 | - | 48 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 209 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Blaubox EC ME 700-3 S31 | 400 | - | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for round air ducts | - | - | aluzinc | yes | no | - | - | - | - | - | - | - | - | 760 | - | 50 | - | - | - | - | Supply | - | - | - | - | - | 3 | 41 | - | - | 3000 | -30…+40 | - | - | 250 | - | 30 mm mineral wool | - | - | - | - | - | - | - | - | - | 27 | 2018 | - | - | - | - | - | - | 116 | 0.5 | 3116 | 5 | - | - | Coarce 90% / G4 (option: ePM1 70% / F7) | - | - | - | - |
KOMFORT LE 530-4 | 230 | - | ceiling mounting, wall mounting, floor mounting | - | - | - | - | - | aluzinc | - | - | - | - | - | - | - | - | - | - | 530 | - | 50/60 | 1100 | - | 88 | - | - | - | - | - | E | - | 1 | 28-47 | cross-flow | polystyrene | 4000 | - | 17.4 | 18.72 | 160 | -25...+40 | 25 mm mineral wool | - | 4300 | - | - | - | - | - | 147 | - | 49 | 2016 | - | G4 | G4 | - | - | - | 300 | 1.32 | - | - | - | - | - | - | - | - | - |
Iso-B 160 | 230 | - | Inline | centrifugal | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | - | - | - | - | 0.33 | - | - | - | 50 | 2690 | - | - | 420 | Exhaust, Supply | 6.4 | 75 | -25 +55 | C | IPX4 | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Sileo 125 | 220-240 | White | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.11 | 17 | 187 | 32* | 50 | - | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 52 | 0.33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 450 4D 50 Hz |
400 | - | wall mounting | axial | 450 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 5280 | - | 50 | 1360 | - | - | - | Exhaust, Supply | - | 250 | - | - | IPX4 | 3 | 56 | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | 1467 | - | 10.5 | - | - | - | - | - | - | IP54 | - | - | - | - | 0.6 | - | - | - | - | - | - |
Axis-Q 450 4D 60 Hz |
400 | - | wall mounting | axial | 450 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 5350 | - | 60 | 1620 | - | - | - | Exhaust, Supply | - | 275 | - | - | IPX4 | 3 | 56 | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | 1486 | - | 10.5 | - | - | - | - | - | - | IP54 | - | - | - | - | 0.65 | - | - | - | - | - | - |
Bravo Chrome 100 (127-220V/60Hz) | 127 | Chrome | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | 0.115 | 10 | 91 | 33* | 60 | 2500 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 | 0.4 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Bravo Chrome 100 (127-220V/60Hz) | 220 | Chrome | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | 0.054 | 9 | 91 | 33* | 60 | 2500 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 | 0.36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
CIVIC EC DBE 500 S21 | 230 | - | ceiling mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | electric preheating | - | - | - | - | - | - | 510 | - | 50/60 | 1700 | - | - | - | Supply and exhaust | 128 | - | - | A | - | 1 | 24 | counter-flow | polystyrene | - | -25...+40 | - | - | 250 | - | 25 mm, cellular synthetic rubber | 74...86* | - | 34 | - | - | 170 | - | 142 | - | - | - | - | G4 | G4, F8 (option F8 C + H11) | - | - | - | - | 1.7 | - | 10.4 | - | 1750 | - | Sensor, LCD | Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | - |
Tower-V 400 4Е | 230 | - | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 2.00 | - | 3950 | - | 50 | 1440 | - | - | - | Exhaust | 33 | 457 | -30…+60 | - | IPX4 | 1 | 55 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1097 | - | - | 2018 | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Centro-M 250 E | 220-240 | - | Inline | centrifugal | 250 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 0.47 | - | 900 | - | 50 | 2050 | - | - | - | Exhaust, Supply | - | 95 | - | C | IPX4 | 1 | 47 | - | - | - | - | - | - | - | -25...+45 | - | - | - | - | - | - | - | - | 250 | - | 6.2 | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |