Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Material | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Type | Power | SEC class | Ingress protection rating | Sound pressure level at 3 m | Voltage | Maximum air flow | SFP | Weight | LED-light power | Power | * | *** |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ducto Power Plus 150 min | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | 0.103 | 22 | 285 | 38* | 50 | 2300 | - | Exhaust, Supply | - | - | - | - | - | 79 | 0.28 | 1.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ducto Power Plus 150 max | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | 0.109 | 25 | 375 | 41* | 50 | 2600 | - | Exhaust, Supply | - | - | - | - | - | 104 | 0.24 | 1.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Sileo V2 125 min | - | White | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | 0.065 | 9.5 | 145 | 28* | 50 | 1800 | - | Exhaust | - | - | - | - | 220-240 | 40 | 0.24 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Sileo V2 125 max | - | White | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | 0.09 | 13.5 | 170 | 32* | 50 | 2250 | - | Exhaust | - | - | - | - | 220-240 | 47 | 0.29 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo DC 110 | 120-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.18 (0.3) | 19 | 187 | 23-25* | 50/60 | 1100 | - | Exhaust | - | B*** | IPX2 | - | - | 52 | 0.37 | 5.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo Compact 250 Light (50 Hz, min) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.12 | 23 | 170 | 25* | 50 | 756 | min | Exhaust | - | - | IPX2 | - | - | 47 | 0.49 | 6.4 | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 250 Light (50 Hz, max) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.18 | 39 | 260 | 29* | 50 | 1122 | max | Exhaust | - | - | IPX2 | - | - | 72 | 0.54 | 6.4 | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 250 Light (60 Hz, min) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.14 | 25 | 160 | 25* | 60 | 732 | min | Exhaust | - | - | IPX2 | - | - | 44 | 0.56 | 6.4 | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 250 Light (60 Hz, max) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.22 | 50 | 270 | 30* | 60 | 1140 | max | Exhaust | - | - | IPX2 | - | - | 75 | 0.67 | 6.4 | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
DPO 125/180 Glas | - | - | - | - | - | - | 180 | 180 | - | - | - | - | glass | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Hi-Fi One 100 S | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | 0.05 | 8 | 85 | 26 | 50 | 2100 | - | - | - | - | - | - | - | 24 | 0.34 | 0.51 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Force 100 | 220-240 | White | wall mounting, flush mounting | centrifugal | 100 | - | - | - | - | - | - | - | - | - | - | 98 | 36* | 50 | 2250 | - | Exhaust | 16 | - | IP2X | - | - | 27 | 0.59 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 250 Light T (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.12 | 23 | 170 | 25* | 50 | 756 | min | Exhaust | - | C*** | IPX2 | - | - | 47 | 0.49 | 6.4 | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 250 Light T (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.18 | 39 | 260 | 29* | 50 | 1122 | max | Exhaust | - | C*** | IPX2 | - | - | 72 | 0.54 | 6.4 | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 250 Light T (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.14 | 25 | 160 | 25* | 60 | 732 | min | Exhaust | - | C*** | IPX2 | - | - | 44 | 0.56 | 6.4 | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 250 Light T (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.22 | 50 | 270 | 30* | 60 | 1140 | max | Exhaust | - | C*** | IPX4, IPX2 | - | - | 75 | 0.67 | 6.4 | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Aero Gold 125 | 220-240 | Gold | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | 0.1 | 16 | 193 | 39* | 50 | 2400 | - | Exhaust | - | - | - | - | - | 54 | 0.3 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 200 (50 Hz, min) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.1 | 20 | 130 | 24* | 50 | 714 | min | Exhaust | - | - | IPX2 | - | - | 36 | 0.55 | 5.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 200 (50 Hz, max) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.13 | 29 | 210 | 27* | 50 | 1026 | max | Exhaust | - | - | IPX2 | - | - | 58 | 0.50 | 5.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 200 (60 Hz, min) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.11 | 21 | 130 | 24* | 60 | 588 | min | Exhaust | - | - | IPX2 | - | - | 36 | 0.58 | 5.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo Compact 200 (60 Hz, max) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.15 | 34 | 225 | 28* | 60 | 936 | max | Exhaust | - | - | IPX2 | - | - | 63 | 0.54 | 5.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro 150 | 220-240 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | 0.13 | 24 | 265 | 37* | 50 | 2400 | - | Exhaust | - | - | - | - | - | 74 | 0.33 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Tubo 100 | 220-240 | White | Inline | axial | 100 | - | - | - | - | - | - | - | - | 0.085 | 14 | 102 | 38* | 50 | 2300 | - | Exhaust, Supply | - | - | - | - | - | 28 | 0.5 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero 100 | 220-240 | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | 0.085 | 14 | 102 | 38* | 50 | 2300 | - | Exhaust | - | - | - | - | - | 28 | 0.49 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 200 T (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.1 | 20 | 130 | 24* | 50 | 714 | min | Exhaust | - | C*** | IPX2 | - | - | 36 | 0.55 | 5.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 200 T (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.13 | 29 | 210 | 27* | 50 | 1026 | max | Exhaust | - | C*** | IPX2 | - | - | 58 | 0.50 | 5.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 200 T (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.11 | 21 | 130 | 24* | 60 | 588 | min | Exhaust | - | C*** | IPX2 | - | - | 36 | 0.58 | 5.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 200 T (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | 0.15 | 34 | 225 | 28* | 60 | 936 | max | Exhaust | - | C*** | IPX2 | - | - | 63 | 0.54 | 5.3 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Quatro Hi-Tech Gold 100 (127-220V/60Hz) | 127 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | 0.115 | 10 | 82 | 33* | 60 | 2500 | - | Exhaust | - | - | - | - | - | 23 | 0.44 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Hi-Tech Gold 100 (127-220V/60Hz) | 220 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | 0.054 | 9 | 82 | 33* | 60 | 2500 | - | Exhaust | - | - | - | - | - | 23 | 0.40 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Trio V2 150 TR min | - | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | 0.079 | - | 210 | 29* | 50 | - | min | Exhaust | - | - | - | - | 220-240 | 58 | 0.31 | 0.97 | - | 18 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Trio V2 150 TR max | - | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | 0.085 | - | 300 | 35* | 50 | - | max | Exhaust | - | - | - | - | 220-240 | 83 | 0.25 | 0.97 | - | 21 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ultra 250 Square | - | - | ceiling mounting | centrifugal | - | 150 | - | - | plastic | no | no | no | - | 0.25 | - | 482 | - | 50 | - | - | Exhaust | 57 | - | IPX4 | 36 | 220-240 | 134 | 0.43 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Sileo Design 100 | 220-240 | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | 0.050 | 7.5 | 90 | 26* | 50/60 | 2165 | - | Exhaust | - | - | - | - | - | 25 | 0.30 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
DPA 100/180 Glas Red | - | - | - | - | - | - | 180 | 180 | - | - | - | - | glass | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Moon One 100 S | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | 0.05 | 8 | 85 | 26 | 50 | 2100 | - | - | - | - | - | - | - | 24 | 0.34 | 0.51 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Still Gold 150 | 220-240 | Gold | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | 0.14 | 19 | 254 | 33* | 50 | - | - | Exhaust | - | - | - | - | - | 71 | 0.27 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Vintage 150 | 220-240 | Vintage | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | 0.13 | 24 | 309 | 40 | 50 | 2400 | - | Exhaust | - | - | - | - | - | 86 | 0.28 | - | - | - | - | - |
Quatro Hi-Tech 125 (127-220V/60Hz) | 127 | Hi-Tech | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | 0.119 | 16 | 170 | 35* | 60 | 2400 | - | Exhaust | - | - | - | - | - | 47 | 0.34 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Hi-Tech 125 (127-220V/60Hz) | 220 | Hi-Tech | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | 0.102 | 15 | 170 | 35* | 60 | 2400 | - | Exhaust | - | - | - | - | - | 47 | 0.32 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Trio 150 SH | - | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | 0.21 | - | 255 | 35* | 50 | - | - | Exhaust | - | - | - | - | 220-240 | 71 | 0.39 | 0.97 | - | 28 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ice 100 | 220-240 | - | wall mounting | axial | 100 | - | - | - | - | - | - | - | - | 0.085 | 14 | 105 | 37 | 50 | 2300 | - | Exhaust | - | - | - | - | - | 29 | 0.48 | - | - | - | - | - |