Description
FEATURES | ||||||||||
Efficient energy saving supply ventilation in flats, houses, cottages, social and commercial spaces. Coarse and fine filters ensure fresh filtered air supply to premises. Various operation modes and regulated air exchange create individually controlled microclimate. Organization of the air supply system with centralized control based on several ventilation units. | ||||||||||
DESIGN | ||||||||||
The ventilator consists of a cartridge with filters, an air duct with sound absorbing material, an indoor unit with a decorative front panel and an outer ventilation hood. The cartridge consists of an energy efficient EC fan and filters that ensure coarse and fine filtration of supply air. The indoor unit is in the basic version equipped with automatic shutters that close during the | ventilator standstill and prevent air backdraft. The outer ventilation hood is used to prevent direct ingress of water and other objects to the ventilator. A remote control, an extended air duct (700 mm) and different external grilles are optionally available for the Fresher 50 units. | |||||||||
|
||||||||||
CONTROL | ||||||||||
The ventilator can be operated with the sensor control panel on the unit casing or with the remote control (FB Fresher 50). | ||||||||||
The ventilator design enables connecting any external controls, such as a humidity sensor, an external CO₂ sensor or a switch. Connection of several ventilators in series provides effective, optimal ventilation. The first unit | in series becomes the master unit Ventilation mode is controlled via the control panel on the master unit. The signal from the remote control is received by the first ventilator (master) only. | |||||||||
MOUNTING | ||||||||||
The unit is designed for through-the-wall mounting into a round hole provided in the outer wall. The unit installation in new-construction buildings is carried out in two phases: 1. Preassembly at the stage of interior and exterior finishing of walls (installing the air duct and the outer ventilation hood, electrical cable laying). | 2. Final assembly - before commissioning the house. It includes installation of the cartridge with the fan and filters as well as installation and connection of the indoor unit with the controller and air shutters. | |||||||||
Characteristics
Characteristics
Parameter | Fresher 50 L ( 1 speed) | Fresher 50 L (2 speed) | Fresher 50 L (3 speed) | Measurement unit |
---|---|---|---|---|
Speed | I | II | III | - |
Voltage | 100-240 | 100-240 | 100-240 | V |
Phase | 1 | 1 | 1 | ˜ |
Frequency | 50/60 | 50/60 | 50/60 | Hz |
Power | 3.8 | 4.7 | 7.4 | W |
Current | 0.031 | 0.039 | 0.061 | A |
Maximum air flow | 20 | 35 | 50 | m³/h |
Maximum air flow | 6 | 10 | 14 | l/s |
Sound pressure level at a distance of 1 m | 22* | 29* | 32* | dBА |
Sound pressure level at 3 m | 13* | 20* | 23* | dBА |
SFP | 0.68 | 0.48 | 0.53 | W/l/s |
Outdoor sound pressure attenuation | 41 | 41 | 41 | dBА |
Filter | F8+G3 | F8+G3 | F8+G3 | - |
Transported air temperature | -30...+50 | -30...+50 | -30...+50 | °С |
Ingress protection rating | IP24 | IP24 | IP24 | - |
Type | Supply | Supply | Supply | - |
PM 2.5 removal efficiency | 98 | 98 | 98 | % |
Mounting | wall mounting | wall mounting | wall mounting | - |
* | Sound pressure level measured in free space | Sound pressure level measured in free space | Sound pressure level measured in free space | - |
Documents archieve
Documents archieve
Select a document type
Dimensions
Dimensions
Designation key
Designation key
Fresher | 50 |
_: 500 |
_: air shutters |
_: ventilation hood by default
1: outer grille Decor 150s St white 2: outer grille Decor 185x185/150s S: Brushed stainless steel ventilation hood AH-S chrome 160 (for thin walls)
S white: Brushed stainless steel ventilation hood painted white AH-S chrome 160 (for thin walls)
S10 chrome: plastic ventilation hood AH-10 chrome 160
S10: plastic ventilation hood AH-10 white 160
|
_: without remote control FB: with remote control |
Model | Nominal air flow [m³/h] | Air duct length [mm] | Air shutters | External grille type option | Option |
Ecodesign parameters
Ecodesign parameters
|
Accessories
Accessories
Accessory name | Description | |
FP Fresher 50 F8 | Filter kit: G3 filter (1 pc) + F8 filter (1 pc) | |
FB Fresher 50 | Remote control | |
CD-1 | CO₂ sensor with LED indication and on/off button | |
CD-2 | CO₂ sensor | |
HR-S | Room humidistat |