Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy

Blauberg Fresher

Fresher
Fresher
zoom

Wall vent. Maximum air capacity up to 50 m³/h.
Model features
  • Description
  • Modifications
  • Downloads
  • Designation key
  • Ecodesign parameters
  • Accessories
Description
Description
FEATURES
Efficient energy saving supply ventilation in flats, houses, cottages, social and commercial spaces. Coarse and fine filters ensure fresh filtered air supply to premises. Various operation modes and regulated air exchange create individually controlled microclimate. Organization of the air supply system with centralized control based on several ventilation units.
DESIGN
The ventilator consists of a cartridge with filters, an air duct with sound absorbing material, an indoor unit with a decorative front panel and an outer ventilation hood. The cartridge consists of an energy efficient EC fan and filters that ensure coarse and fine filtration of supply air. The indoor unit is in the basic version equipped with automatic shutters that close during the ventilator standstill and prevent air backdraft. The outer ventilation hood is used to prevent direct ingress of water and other objects to the ventilator. A remote control, an extended air duct (700 mm) and different external grilles are optionally available for the Fresher 50 units.

 
Easy maintenance. The indoor unit can be opened applying a light pressure from both sides The built-in automatic air shutters prevent back air draft One of the highest air cleaning efficiency ratings on the market through the use of a modern filter system The specially designed front panel provides 100 % tightness and wind protection
CONTROL
The ventilator can be operated with the sensor control panel on the unit casing or with the remote control (FB Fresher 50).  

The ventilator design enables connecting any external controls, such as a humidity sensor, an external CO₂ sensor or a switch. Connection of several ventilators in series provides effective, optimal ventilation. The first unit in series becomes the master unit Ventilation mode is controlled via the control panel on the master unit. The signal from the remote control is received by the first ventilator (master) only.

MOUNTING
The unit is designed for through-the-wall mounting into a round hole provided in the outer wall. The unit installation in new-construction buildings is carried out in two phases: 1. Preassembly at the stage of interior and exterior finishing of walls (installing the air duct and the outer ventilation hood, electrical cable laying) 2. Final assembly - before commissioning the house. It includes installation of the cartridge with the fan and filters as well as installation and connection of the indoor unit with the controller and air shutters.

Modifications
Modification name
Fresher 50
Fresher 50 L
+
+
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
Fresher - data sheet (pdf 1.07Mb)
Fresher - user manual (pdf 4.45Mb)
Fresher - image (png 174.24Kb)
Designation key
Designation key
Fresher 50

_: 500
L: 700

_: air shutters
M: no air shutters

_: ventilation hood by default
1: outer grille Decor 150s St white
2: outer grille Decor 185x185/150s
S: Brushed stainless steel ventilation hood AH-S chrome 160 (for thin walls)
S white: Brushed stainless steel ventilation hood painted white AH-S chrome 160 (for thin walls)
S10 chrome: plastic ventilation hood AH-10 chrome 160
S10: plastic ventilation hood AH-10 white 160
_: without remote control
FB: with remote control
Model Nominal air flow [m³/h] Air duct length [mm] Air shutters External grille type option Option 
Ecodesign parameters
Ecodesign parameters
Trade mark BLAUBERG
Model Fresher 50
Specific energy consumption (SEC) [kWh(m²a)] Cold Average Warm
-53.2 А+ -26.1 B -10.6 Е
Type of ventilation unit Unidirectional
Type of drive installed Multi-speed
Type of heat recovery system No
Thermal efficiency of heat recovery [%] n/a
Maximum air flow [m³/h] 50
Power [W] 6.6
Sound power level [dBA] 40
Reference flow rate [m³/s] 0.01
Reference pressure difference [Pa] n/a
Specific power input (SPI) [W/m³/h] 0.134
Control typology Local demand control
Maximum internal leakage rates [%] n/a
Maximum external leakage rates [%] 2.7
Internet address http://www.blaubergventilatoren.de/
The annual electricity consumption (AEC)[kWh electricity/a] Cold Average Warm
88 88 88
The annual heating saved (AHS)[kWh primary energy/a] Cold Average Warm
5536 2830 1280
Accessories
Accessories
Accessory name   Description
FP Fresher 50 F8 Filter kit: G3 filter (1 pc) + F8 filter (1 pc)
FB Fresher 50 Remote control
CD-1   CO sensor with LED indication and on/off button
CD-2   CO₂ sensor
HR-S   Room humidistat