Blauberg Reneo-Fit D 100-E S14


Suspended heat and energy recovery air handling unit. Maximum air flow up to 130 m³/h.
EAN codeEAN4058448088971
  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Designation key
  • Accessories
  • Additional characteristics
  • Dimensions
Description
Description
FEATURES

Air handling units for efficient supply and exhaust ventilation in flats and apartments. Heat recovery minimizes ventilation heat losses during cold season and reduce air conditioner load during hot season. Controllable air exchange for creating the best suitable indoor microclimate.

DESIGN

The casing is made of expanded polypropylene (EPP) with high heat- and sound-insulating properties.

 

FANS

High-efficient external rotor EC motors and centrifugal impellers with forward curved blades are used for air supply and exhaust.

AIR FILTRATION

Two built-in G4 and F7 filters provide efficient supply air filtration.The G4 filter is used for extract air filtration.

HEAT RECOVERY
   
The Reneo-Fit D 100-E unit is equipped with an enthalpy counter-flow heat exchanger for heat and humidity recovery.
MOUNTING

The units are designed for suspended ceiling mounting. Service access for maintenance and filter replacement must be provided.

  CONTROL AND AUTOMATION

Reneo-Fit D 100-E S14 units are equipped with an integrated automation system and an S14 wall-mounted control panel with LED-indication.

AUTOMATION FUNCTIONS
Functions Description
Unit control via a remote wired control panel
S14 control panel
Speed switch +
Filter replacement indication by filter timer
Alarm indication LED indication about alarms
Freeze protection using cyclical stops of the supply fan
Humidity control option
CO2 control option
Fire alarm sensor connection option

Option: the functionality is available when purchasing the appropriate accessory (see the "Accessories" section)
Characteristics
Characteristics
Parameter Reneo-Fit D 100-E S14 Measurement unit
Voltage 230 V
Phase 1 ˜
Frequency 50/60 Hz
Max. unit power 45 W
Max. unit current 0.34 A
Maximum air flow 36 l/s
Maximum air flow 130 m³/h
Sound pressure level at 3 m 32 dBА
Transported air temperature -23…+40 °С
Insulation 25 mm mm
Extract filter G4 / Coarse > 60 % -
Supply filter G4 / Coarse > 60 % (option: F7 / ePM1 60 %) -
Heat recovery efficiency 73–88 %
Heat exchanger type counter-flow -
Heat exchanger material enthalpy -
Connected air duct diameter 100 / 125 mm
Weight 8 kg
Casing material EPP -
Type Supply and exhaust -
SEC class A -
Mounting ceiling mounting -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
S14 / S15 automation - software (zip 13.08Mb)
Reneo-Fit D 100 S14 - data sheet (pdf 831.13Kb)
Reneo-Fit D 100 S14 - image (png 796.86Kb)
Reneo-Fit D 100 S14 - user's manual (pdf 2.44Mb)
Designation key
Designation key
Series   Casing modification   Casing type   Heater   Nominal size   Modification   Heat exchanger type   Service side   Controller type
Reneo Fit: compact   D: suspended   _: w/o heater   10: Nominal airflow   0: by default E: energy recovery   _: universal   S14
Accessories
Accessories
    Reneo-Fit D 100-E S14
G4 panel filter FP 176х150х22 G4
F7 panel filter FP 176х150х22 F7
Control panel S14
Humidity sensor FS2
Humidity sensor HR-S
CO sensor CD-2
CO sensor with indication CD-1
Syphon kit (for the units without an enthalpy heat exchanger) SFK 20x32
Air damper VKA 125
Electric actuator TF230
Additional characteristics
Additional characteristics
Point Air flow [m³h (l/s)] Total sound pressure level (breakout) at 3 m (1 m) distance [dB(A)]
1 130 (36) @ 0 Pa 32 (42)
2 91 (25) @ 0 Pa 25 (35)
3 52 (14) @ 0 Pa 16 (26)
4 52 (14) @ 171 Pa 31 (41)
5 96 (27) @ 92 Pa 33 (42)
6 68 (19) @ 50 Pa 25 (34)

 

Sound power level, A-weighted Octave frequency band [Hz] LpA 3 m LpA 1 m
Total 200 400 800 1000 2000 4000 8000
LwA to supply outlet [dBA] 59 44 45 49 51 44 37 38 38 48
LwA to exhaust inlet [dBA] 47 41 36 33 31 29 22 24 27 36
LwA to environment [dBA] 53 37 41 43 42 38 34 29 33 42

Sound data provided for point 2 on the diagram.

Dimensions
Dimensions

Model Overall dimensions [mm]
H L L1 W W1
Reneo-Fit D 100-E S14 242 530 630 520 600