Description
Description
USE

Exhaust ventilation systems installed in high-rise buildings and premises.For buildings with a mono-pipe ventilation system.For mounting in kitchens and bathrooms.Surface wall or ceiling mounting.

DESIGN

The fan consists of a plastic casing for surface mounting and an exhaust ventilation unit Valeo with a flat front panel.The casing is made of durable ABS plastic and fitted with a gravity backdraft damper to prevent backdrafting.

The front panel is made of snow-white UV-resistant plastic.Filter with filter class G4 for motor, impeller and ductwork system protection against soiling.The filter is easily accessible for service operations.Due to modern design and various colour modifications the front panel matches well with any interior.The casing is equipped with oblong slotted joints to facilitate mounting of the casing in true vertical position.Power is supplied to the fan through a sealed electric lead-in on the casing and the ventilation unit is equipped with an airtight terminal block for connection to the wiring system.Exhaust spigot diameter 80 mm.Ingress protection rating IP55.

OPTIONS

TIMER (VALEO-E...Т)
Depending on wiring connection the fan is off or runs permanently at low speed. The fan is turned to higher speed with external switch 50 s after activation. After turning the switch off the fan continues operating within 6 min at higher speed and then reverts to default operation mode.
ADJUSTIBLE TIMER (VALEO-E...ТR)
Depending on wiring connection the fan is off or runs permanently at low speed. If the fan is turned on with an external switch it switches to higher speed 0 to 150 s after switch activation. After turning the fan off it continues running at higher speed 2 to 30 minutes and then reverts to previous mode. The fan run-out time and delay time for higher speed are regulated with the internal regulator.
INTERVAL SWITCH (VALEO-E...I)
Depending on wiring connection the fan is off or runs permanently at low speed. In interval mode regulated from 0,5 to 15 hours the fan switches periodically to higher speed for 10 minutes. The switch interval is adjusted with the internal regulator. If light in the room is turned with the external switch the fan switches to higher speed in 50 s. After light is off the fan reverts to interval mode operation.
HUMIDITY SENSOR (VALEO-E...H)
Depending on wiring connection the fan is off or runs permanently at low speed. The fan switches to higher speed as relative humidity in the room increases from 60 % up to 90 % and switches off as humidity drops by 10 % below set level. If light in the room is turned on the fan switches to higher speed in 50 s. The run-out time is set by the internal regulator from 2 to 30 minutes.

MOTOR SPEED CONTROL

Two-speed motor with a centrifugal impeller. Minimum energy demand.The impeller has forward curved blades.Automatic maintaining of constant air flow depending on variable air resistance of the duct.Balanced impeller ensures low-noise operation.Best aerodynamic characteristics due to special scroll casing design.Ball bearings provide long service life.The ventilation unit with a motor is fixed inside the casing with special latches.

Step speed control with an external speed controller, e.g. CDP-3/5 model which is available upon order.Wide range of intellectual controls programmable by set parameters (timer, adjustable timer, internal switch, humidity sensor).

MOUNTING MOUNTING EXAMPLE

Flexible air ducts connected to the ductwork system and wiring are routed to the fan through the wall or ceiling.After finishing works a flexible air duct is fixed on the fan spigot with clamps.Power is supplied to the fan through a sealed electric lead-in on the casing.The casing is installed at site with dowels and is adjusted vertically with oblong slotted joints.The ventilation unit connected to the wiring system is installed in the mounted and fixed casing.

HIGH-RISE MONO-PIPE VENTILATION SYSTEM ARRANGEMENT EXAMPLE

The mechanical centralized mono-pipe exhaust ventilation system for kitchens and bathrooms based on Valeo-E fans is specially designed for high-rise residential premises.Fresh air is supplied to bedrooms, children's room or living rooms through windows or wall vents. Vent modifications with air volume regulation are available.

Stale air is extracted from the room by the exhaust fans through the inside doors or door grilles in the kitchen, bathroom or WC.This ventilation system arrangement ensures non-stop controllable air circulation in the room, comfortable microclimate and high fire safety.

1 – Exhaust fan Valeo-E (surface mounting).2 – Exhaust fan Valeo-E (ceiling mounting).3 – BLAUBERG wall vent, WMH series.4 – BLAUBERG window vent, FHM series.5 – BLAUBERG ventilation grilles, DECOR series.6 – Central ventilation shaft.7 – Flexible air ducts for connection of exhaust fans to the central ventilation shaft, e.g. BLAUBERG air ducts, Blauflex series.
Characteristics
Characteristics
Parameter Valeo-E 75/100
(1 speed)
Valeo-E 75/100
(2 speed)
Valeo-E 75/100 T
(1 speed)
Valeo-E 75/100 T
(2 speed)
Valeo-E 75/100 TR
(1 speed)
Valeo-E 75/100 TR
(2 speed)
Valeo-E 75/100 H
(1 speed)
Valeo-E 75/100 H
(2 speed)
Valeo-E 75/100 I
(1 speed)
Valeo-E 75/100 I
(2 speed)
Measurement unit
Speed I II I II I II I II I II -
Voltage 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 V
Frequency 50 50 50 50 50 50 50 50 50 50 Hz
Current 0.11 0.13 0.11 0.13 0.11 0.13 0.11 0.13 0.11 0.13 A
Power 24 29 24 29 24 29 24 29 24 29 W
Cable cross section 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 mm²
Maximum air flow 21 28 21 28 21 28 21 28 21 28 l/s
Maximum air flow 75 100 75 100 75 100 75 100 75 100 m³/h
Sound pressure level 29* 38* 29* 38* 29* 38* 29* 38* 29* 38* dBА
Max. operating temperature +50 +50 +50 +50 +50 +50 +50 +50 +50 +50 °С
Motor IP rating IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 -
EC motor no no no no no no no no no no -
Casing material plastic plastic plastic plastic plastic plastic plastic plastic plastic plastic -
Outdoor mounting no no no no no no no no no no -
Air duct for round air ducts for round air ducts for round air ducts for round air ducts for round air ducts for round air ducts for round air ducts for round air ducts for round air ducts for round air ducts -
Design centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal -
Type Exhaust Exhaust Exhaust Exhaust Exhaust Exhaust Exhaust Exhaust Exhaust Exhaust -
Mounting ceiling mounting, wall mounting ceiling mounting, wall mounting ceiling mounting, wall mounting ceiling mounting, wall mounting ceiling mounting, wall mounting ceiling mounting, wall mounting ceiling mounting, wall mounting ceiling mounting, wall mounting ceiling mounting, wall mounting ceiling mounting, wall mounting -
* Sound pressure level measured in free space at a distance of 3 meters from the fan Sound pressure level measured in free space at a distance of 3 meters from the fan Sound pressure level measured in free space at a distance of 3 meters from the fan Sound pressure level measured in free space at a distance of 3 meters from the fan Sound pressure level measured in free space at a distance of 3 meters from the fan Sound pressure level measured in free space at a distance of 3 meters from the fan Sound pressure level measured in free space at a distance of 3 meters from the fan Sound pressure level measured in free space at a distance of 3 meters from the fan Sound pressure level measured in free space at a distance of 3 meters from the fan Sound pressure level measured in free space at a distance of 3 meters from the fan -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
Valeo - user's manual (pdf 2.82Mb)
Valeo-E - data sheet (pdf 748.94Kb)
Valeo-E 35/60 - user manual (pdf 1.78Mb)
Valeo-E - image (png 409.39Kb)
Sound insulation kit for the Valeo fans - installation instruction (pdf 427.93Kb)
Modifications
Modification name Timer Humidity sensor Interval Timer No extra functions Adjustible timer
Valeo-E 75/100 - - - -
Valeo-E 75/100 H - - - -
Valeo-E 75/100 I - - - -
Valeo-E 75/100 T - - - -
Valeo-E 75/100 TR - - - -
+
+
+
+
+
Dimensions
Dimensions

Designation key
Designation key
Valeo-E 35/60

TR

Model Air flow according to speed Option
Accessories
Accessories
Filter Flexible air duct Speed controller Clamp
       

FP-Valeo

BlauFlex AN CDP-2/5 K