Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy

Blauberg ЕКН (rectangular)

ЕКН (rectangular)
ЕКН (rectangular)
zoom

Duct electrical heaters for rectangular ducts.
Model features
  • Description
  • Modifications
  • Downloads
  • Designation key
  • Characteristics
Description
Description
FEATURES

For warming up of supply air in heating, ventilation and air conditioning systems installed in various premises. Compatible with 400×200 up to 1000×500 mm rectangular air ducts.

DESIGN

Galvanized steel case and junction box. Heating elements are made of stainless steel and have additional ribbing to increase heat exchange surface. Several power options for each standard size. For higher heating capacity several heaters may be installed in series. Equipped with overheat protection thermostats:

  • basic protection with automatic restart at +50 °C;
  • emergency protection with manual restart at +90 °C.
  MOUNTING

Fixing to rectangular ducts with flange connection. Any mounting position except for the junction box downwards to prevent condensate leakage and short circuit. Install a filter upstream to the heater to protect heating elements against dirt ingress. Recommended distance between the heater and other system components must be not less than one air heater diagonal for air flow stabilization. Duct heaters are rated for minimum air flow speed 1.5 m/s and maximum operating air temperature supplied to the units 40 °C. In case of speed regulation with a speed controller the minimum air speed through the heater must be provided. For correct and safe heater operation an automatic control and protection system is recommended, including the following functions:

  • regulation of the heating capacity and temperature of the air heated up;
  • filter clogging control by a differential air pressure sensor;
  • power cut-off in case of the supply fan shutdown or low air flow speed as well as in case of actuating the overheat protection thermostats;
  • heat removal from the heating elements after ventilation system shutdown.
Modifications
Modification name
EKH 100x50-45
EKH 100x50-54
EKH 40x20-10.5
EKH 40x20-12
EKH 40x20-15
EKH 40x20-4.5
EKH 40x20-6
EKH 40x20-7.5
EKH 40x20-9
EKH 50x25-10.5
EKH 50x25-12
EKH 50x25-15
EKH 50x25-18
EKH 50x25-21
EKH 50x25-6
EKH 50x25-7.5
EKH 50x25-9
EKH 50x30-10.5
EKH 50x30-12
EKH 50x30-15
EKH 50x30-18
EKH 50x30-21
EKH 50x30-6
EKH 50x30-7.5
EKH 50x30-9
EKH 60x30-12
EKH 60x30-15
EKH 60x30-18
EKH 60x30-21
EKH 60x30-24
EKH 60x30-9
EKH 60x35-12
EKH 60x35-15
EKH 60x35-18
EKH 60x35-21
EKH 60x35-24
EKH 60x35-9
EKH 70x40-18
EKH 70x40-27
EKH 70x40-36
EKH 80x50-27
EKH 80x50-36
EKH 80x50-54
EKH 90x50-45
EKH 90x50-54
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
ЕКН (rectangular) - data sheet (pdf 695.06Kb)
ЕКН (rectangular) - operation manual (pdf 2.1Mb)
ЕКН (rectangular) - image (png 637.83Kb)
Designation key
Designation key
Series Flange size (WxH) [cm]   Heater power [kW]
EKH 40x20; 50x25; 50x30; 60x30; 60x35; 70x40; 80x50; 90x50; 100x50 4.5; 6; 7.5; 9; 10.5; 12; 15; 18; 21; 24; 27; 36; 45; 54
Characteristics
Characteristics
AIR TEMPERATURE INCREASE AS A FUNCTION OF AIR FLOW