Description
Description
FEATURES  

Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings. Heat recovery minimizes ventilation heat losses during cold season and reduce air conditioner load during hot season. Controllable air exchange for creating the best suitable indoor microclimate. Compatible with round Ø150 mm air ducts.

DESIGN

The casing is made of expanded polypropylene (EPP) 15-30 mm thick with high heat- and sound-insulating properties.The spigots are located at the side of the unit and are rubber sealed for airtight connection to the air ducts. 

FANS  

High-efficient external rotor EC motors and centrifugal impellers with forward curved blades are used for air supply and exhaust. EC motors have the best power consumption to air flow ratio and meet the latest demands concerning energy saving and high-efficient ventilation.

EC motors are featured with high performance, low noise level and totally controllable speed range. Dynamically balanced impellers.

AIR FILTRATION BYPASS

Two built-in G4 and F7 filters provide efficient supply air filtration. The G4 filter is used for extract air filtration.

The KOMFORT EC D5B180(-E) models are equipped with a bypass which can be opened if there is a need to cool down the ventilated area with cool intake air. 

HEAT RECOVERY MOUNTING

The KOMFORT EC D5(B)180 unit is equipped with a plate counter-flow polystyrene heat exchanger for heat recovery. In the unit condensate is collected and drained to the drain pan under the heat exchanger. 
The KOMFORT EC D5(B)180-E unit is equipped with an enthalpy plate counter-flow heat exchanger for enegry (heat and humidity) recovery. Due to humidity recovery condensate is not generated in the enthalpy heat exchanger. 

The air flows are completely separated in the heat exchanger. Thus smells and contaminants are not transferred from the extract air to the supply air.Heat recovery is based on heat and/or humidity transfer through the heat exchanger plates. In the cold season supply air is heated in the heat exchanger by transferring the heat energy of warm and humid extract air to the cold fresh air. Heat recovery minimizes ventilation heat losses and heating costs respectively. In the warm season the heat exchanger performs reverse and intake air is cooled in the heat exchanger by the cool extract air. That reduces operation load on air conditioners and saves electricity.

The units are designed for suspended ceiling mounting, vertical or horizontal wall mounting.Sufficient service access for maintenance and filter replacement must be provided.

CONTROL AND AUTOMATION

The KOMFORT EC D5B180(-E) S21 units are equipped with a built-in automation system. The remote control panel is not included in the delivery set (sold separately). 
Unit control via Wi-Fi using the mobile application Blauberg AHU.

Download
the Blauberg AHU
App for Android
Download
the Blauberg AHU 
app for iOS

The KOMFORT EC D5B180(-E) S14 units are equipped with an integrated automation system and an S14 wall mounted sensor control panel with LED-indication.
The KOMFORT EC D5 180(-E) S2 units are equipped with a CDT E/0-10 speed regulator.

AUTOMATION FUNCTIONS  

Functions KOMFORT EC D5B180(-E) S21 KOMFORT EC D5B180(-E) S14 KOMFORT EC D5 180(-E) S2
Unit control via Wi-Fi using the mobile application + - -
Unit control via remote control panel S22 control panel (option)
S14 control panel
CDT E/0-10 speed controller
Control via a wired remote LCD control panel S25 control panel (option)
- -
Unit control via remote wireless control panel S22 WiFi control panel (option)
- -
Speed switch + + +
Filter replacement indication according to filter timer according to filter timer -
Alarm indication full description of the alarm in the mobile application LED indication about alarms -
Week scheduled operation + - -
Bypass automatic - -
manual manual -
Timer + - -
Boost mode + - -
Kamin mode + - -
Freeze protection using cyclical stops of the supply fan using cyclical stops of the supply fan using cyclical stops of the supply fan
using preheating (option) - -
Reheater connection option - -
Cooler connection option - -
Minimum supply air temperature control + - -
Humidity control option option -
control CO2 option option -
VOC control option - -
PM2.5 control option - -
Fire alarm sensor connection option option -
Modifications
Modification name
KOMFORT EC D5 180 S2
KOMFORT EC D5 180-E S2
KOMFORT EC D5B180 S14
KOMFORT EC D5B180 S21
KOMFORT EC D5B180-E S14
KOMFORT EC D5B180-E S21
+
+
+
+
+
+
Capacity diagram
Capacity diagram
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Documents archieve
Documents archieve
Name
KOMFORT EC D5(B)180(-E) - data sheet (pdf 1.31Mb)
KOMFORT EC D5(B)180(-E) - image (png 267.12Kb)
KOMFORT EC D5(B)180(-E) - operation manual (pdf 2.61Mb)
S14 / S15 automation - software (zip 13.08Mb)
KOMFORT EC D5(B)180(-E) S14 - image (png 279.39Kb)
KOMFORT EC D5 180(-E) S2 - image (png 282.99Kb)
KOMFORT EC D5(B)180(-E) S21 - image (png 302.52Kb)
Designation key
Designation key
Serie Motor type Mounting type Casing modification Bypass Nominal air flow [m³/h]  Heat exchanger type Control
KOMFORT EC: electronically commutated motor

S: vertical spigot orientation

5: EPP _ : without a bypass
B: 
integrated bypass
180

_: heat recovery
–E: energy recovery

S21
S14
S2
Accessories
Accessories
    KOMFORT EC D5(B)180(-E) S21 KOMFORT EC D5(B)180(-E) S14 KOMFORT EC D5 180(-E) S2
G4 panel filter FP 214x186x18 G4  FP 214x186x18 G4  FP 214x186x18 G4
F7 panel filter FP 214x186x48 F7  FP 214x186x48 F7  FP 214x186x48 F7
Wired control panel S22 -
Wireless control panel S22 Wi-Fi -
Wired control panel S25 -
Internal humidity sensor FS2 FS2  -
Humidity sensor HR-S HR-S  -
CO₂ sensor with indication CD-1  CD-1 -
 CO₂ sensor CD-2 CD-2 -
VOC sensor   DPWQ30600 -
CO₂ sensor   DPWQ40200 -
Humidity sensor   DPWC11200 -
Electrical preheater   EVH 150 -
Electrical reheater   ENH 150 -
Syphon kit
(for the units without an enthalpy heat exchanger)
SFK 20x32 SFK 20x32 SFK 20x32
Air damper VKA 150 VKA 150  -
Electric actuator LF230 LF230  -