Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Heating | Form | Length | Material | Device | Current | Power | Maximum air flow | Sound pressure level | Air capacity factory settings | Control range | Frequency | RPM | Mode | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Heat exchanger type | Heat exchanger material | Connected air duct diameter | Transported air temperature | Sectional size | Heat recovery efficiency | Voltage | Air pass | Reheater power consumption | Insulation thikness | Maximum air flow | SFP | Weight | ErP | Extract filter | Supply filter | Motor IP rating | Max. power without electric heater | Preheater power consumption | Max. current consumption with heater(s) | Sound pressure level at 3 m in accordance with ISO 3741:2004 | Remote control panel | Functions | Power | * |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Decor 155x155H | - | - | wall mounting, outdoor mounting | no flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.008 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Aero 125 | 220-240 | White | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 16 | 193 | 39* | - | - | 50 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 54 | 0.3 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Bavaria One 100 | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.05 | 8 | 85 | 26 | - | - | 50 | 2100 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 24 | 0.34 | 0.51 | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Quatro Hi-Tech Chrome 125 (127-220V/60Hz) | 127 | Hi-Tech Chrome | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.119 | 16 | 170 | 35* | - | - | 60 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.34 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Quatro Hi-Tech Chrome 125 (127-220V/60Hz) | 220 | Hi-Tech Chrome | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.102 | 15 | 170 | 35* | - | - | 60 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.32 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Extero 100 50 Hz |
230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 0.31 | - | 325 | - | - | - | 50 | 2530 | - | - | - | Exhaust | - | 71 | +55 | C | IPX4 | 1 | 54 | - | - | - | - | - | - | - | - | - | - | 90 | - | 4.1 | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
Extero 100 60 Hz |
230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 0.40 | - | 350 | - | - | - | 60 | 2625 | - | - | - | Exhaust | - | 92 | +55 | C | IPX4 | 1 | 54 | - | - | - | - | - | - | - | - | - | - | 97 | - | 4.1 | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
BlauFlex AF M0/102/1 | - | - | - | - | 102 | - | - | - | - | - | - | - | - | - | 1000 | - | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast WP 110x55 | - | - | - | - | - | for rectangular air ducts | - | - | - | - | - | - | - | rectangular | - | plastic | connection plate | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 55х110 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Slim 100 | 220-240 | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | 0.085 | 14 | 105 | 33* | - | - | 50 | 2300 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 29 | 0.48 | 0.6 | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Freshbox E1-200 ERV WiFi Speed I |
230 | - | - | - | - | - | - | - | polymer-coated steel | - | - | - | electric reheating | - | - | - | - | - | - | 30 | - | - | - | 50/60 | 2000 | - | I | - | - | - | - | - | A | - | 1 | - | counter-flow | enthalpy | 100 | -15...+40 | - | 85 | - | - | 700 | 30 | 8 | - | 55 | - | G4 | G4 + F7 (Option: H13) | - | 10 | — | 4.2 | 12 | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - |
Freshbox E1-200 ERV WiFi Speed II |
230 | - | - | - | - | - | - | - | polymer-coated steel | - | - | - | electric reheating | - | - | - | - | - | - | 60 | - | - | - | 50/60 | 2000 | - | II | - | - | - | - | - | A | - | 1 | - | counter-flow | enthalpy | 100 | -15...+40 | - | 81 | - | - | 700 | 30 | 17 | - | 55 | - | G4 | G4 + F7 (Option: H13) | - | 15 | — | 4.2 | 22 | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - |
Freshbox E1-200 ERV WiFi Speed III |
230 | - | - | - | - | - | - | - | polymer-coated steel | - | - | - | electric reheating | - | - | - | - | - | - | 90 | - | - | - | 50/60 | 2000 | - | III | - | - | - | - | - | A | - | 1 | - | counter-flow | enthalpy | 100 | -15...+40 | - | 75 | - | - | 700 | 30 | 25 | - | 55 | - | G4 | G4 + F7 (Option: H13) | - | 25 | — | 4.2 | 30 | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - |
Freshbox E1-200 ERV WiFi Speed IV |
230 | - | - | - | - | - | - | - | polymer-coated steel | - | - | - | electric reheating | - | - | - | - | - | - | 120 | - | - | - | 50/60 | 2000 | - | IV | - | - | - | - | - | A | - | 1 | - | counter-flow | enthalpy | 100 | -15...+40 | - | 68 | - | - | 700 | 30 | 33 | - | 55 | - | G4 | G4 + F7 (Option: H13) | - | 44 | — | 4.2 | 36 | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - |
Freshbox E1-200 ERV WiFi Speed V |
230 | - | - | - | - | - | - | - | polymer-coated steel | - | - | - | electric reheating | - | - | - | - | - | - | 200 | - | - | - | 50/60 | 2000 | - | V | - | - | - | - | - | A | - | 1 | - | counter-flow | enthalpy | 100 | -15...+40 | - | 66 | - | - | 700 | 30 | 56 | - | 55 | - | G4 | G4 + F7 (Option: H13) | - | 134 | — | 4.2 | 45 | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - |
Aero Still Gold 150 | 220-240 | Gold | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | - | 0.14 | 19 | 254 | 33* | - | - | 50 | - | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 71 | 0.27 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Tubo 150 | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 30 | 295 | 40* | - | - | 50 | 2400 | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 82 | 0.37 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
BlauPlast RR 200/1 | - | - | - | - | 200 | - | - | - | - | - | - | - | - | round | 1000 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 155x155/HUK | - | - | wall mounting, outdoor mounting | round flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.08 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ducto 150 | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | - | 0.095 | 22 | 340 | 39* | - | - | 50 | 2250 | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 94 | 0.23 | 1.3 | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
BlauPlast RVC 125 | - | - | - | - | 125 | for round air ducts | - | - | - | - | - | - | - | round | 136 | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Quatro Platinum 150 (127-220V/60Hz) | 127 | Platinum | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | - | 0.175 | 25 | 240 | 37* | - | - | 60 | 2350 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 67 | 0.37 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Quatro Platinum 150 (127-220V/60Hz) | 220 | Platinum | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | - | 0.338 | 25 | 240 | 37* | - | - | 60 | 2350 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 67 | 0.37 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Box-D 100 L (50 Hz) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | - | 0.34 | - | - | - | - | - | 50 | 2300 | - | - | 190 | Exhaust | 2.9 | 56 | -25 +45 | C | IPX4 | 1 | 42 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-D 100 L (60 Hz) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | - | 0.35 | - | - | - | - | - | 60 | 2570 | - | - | 205 | Exhaust | 2.9 | 58 | -25 +45 | C | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauFlex АF M0/127/3 | - | - | - | - | 127 | - | - | - | - | - | - | - | - | - | 3000 | - | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RVF 100 | - | - | - | - | - | for round air ducts | - | - | - | - | - | - | - | round | 60 | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Bravo Chrome 125 (127-220V/60Hz) | 127 | Chrome | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.119 | 16 | 189 | 34* | - | - | 60 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 53 | 0.3 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Bravo Chrome 125 (127-220V/60Hz) | 220 | Chrome | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.102 | 15 | 189 | 34* | - | - | 60 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 53 | 0.29 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Centro-MZ 125 50 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 125 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | - | 0.34 | - | 330 | - | - | - | 50 | 2820 | - | - | - | Supply and exhaust | 3.16 | 78 | - | C | IPX4 | 1 | 46 | - | - | - | -25...+55 | - | - | - | - | - | - | 92 | - | - | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
Centro-MZ 125 60 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 125 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | - | 0.34 | - | 340 | - | - | - | 60 | 2880 | - | - | - | Supply and exhaust | 3.16 | 79 | - | C | IPX4 | 1 | 46 | - | - | - | -25...+50 | - | - | - | - | - | - | 94 | - | - | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
BlauPlast RSV 125 | - | - | - | - | 125 | for round air ducts | - | - | - | - | - | - | - | round | 60 | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 185x185/150H | - | - | wall mounting, outdoor mounting | round flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.012 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Smart IR 100 24 hours | 100-240 | - | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 33 | 17 | 33 | 0 | 50/60 | - | 24 hours | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 9 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Smart IR 100 Quiet | 100-240 | - | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 72 | 22 | 72 | 33 - 72 | 50/60 | - | Quiet | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Smart IR 100 Maximal | 100-240 | - | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 106 | 31 | 82 | 72 - 106 | 50/60 | - | Max | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 29 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Smart IR 125 24 hours | 100-240 | - | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 40 | 17 | 40 | 0 | 50/60 | - | 24 hours | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 11 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Smart IR 125 Quiet | 100-240 | - | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 83 | 21 | 83 | 40 - 83 | 50/60 | - | Quiet | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 23 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Smart IR 125 Maximal | 100-240 | - | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 133 | 32 | 97 | 83 - 133 | 50/60 | - | Max | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 37 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Trio V2 100 min | - | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | 0.03 | - | 54 | 23* | - | - | 50 | - | - | min | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | 15 | 0.33 | 0.55 | - | - | - | - | - | - | - | - | - | - | 5 | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Trio V2 100 max | - | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | 0.05 | - | 81 | 28* | - | - | 50 | - | - | max | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | 23 | 0.36 | 0.55 | - | - | - | - | - | - | - | - | - | - | 8 | Sound pressure level measured in free space at a distance of 3 meters from the fan |