Selected 884 products
Mode PhaseVoltageRPMSound pressure level at 3 mCasing materialTransported air temperature CurrentFrequencyMountingDesignAir ductEC motorOutdoor mountingSound-insulated casingTypeConnected air duct size Number of water coil rowsTotal unit powerMaximum air flowMaximum air flowInsulationWeightErPSupply filterFan currentElectric heater powerElectric heater currentFan powerFilterSpeedTransported air temperatureInsulation thiknessHeat exchanger typeHeat exchanger materialConnected air duct diameterSEC classWeight HeatingFunctionsRemote control panelSound pressure level at 3 m in accordance with ISO 3741:2004Extract filterHeat recovery efficiencyPreheater power consumptionReheater power consumptionMax. unit current without electric heaterMax. unit current with electric heaterMax. power without electric heater***FormConnection diameterLengthMaterialDeviceAir duct wireOperating temperature rangeAir speedMaximum operating pressure
Freshbox 100
Speed I
1 110-240 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 30 8 - - - G4, F8 (Option: F8 C, H13) - - - - - I -20...+40 10 counter-flow polystyrene 100 A 31 without heating Filter replacement indication, Timer, Weekly schedule LCD 13 G4 98 - - 0.4 - 12 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox 100
Speed II
1 110-240 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 60 17 - - - G4, F8 (Option: F8 C, H13) - - - - - II -20...+40 10 counter-flow polystyrene 100 A 31 without heating Filter replacement indication, Timer, Weekly schedule LCD 27 G4 92 - - 0.4 - 21 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox 100
Speed III
1 110-240 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 100 28 - - - G4, F8 (Option: F8 C, H13) - - - - - III -20...+40 10 counter-flow polystyrene 100 A 31 without heating Filter replacement indication, Timer, Weekly schedule LCD 39 G4 89 - - 0.4 - 45 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
BLAUBOX MW 1200-4 Pro 1 230 1850 38 aluzinc -25...+40 1.8 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 400х200 4 410 1200 333 25 mm mineral wool 42.8 2016, 2018 G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX MW 1800-4 Pro 1 230 1100 40 aluzinc -25...+40 2.15 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 500х250 4 490 1870 519 25 mm mineral wool 62.5 2016, 2018 G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX MW 2100-4 Pro 1 230 1000 45 aluzinc -25...+40 2.84 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 500х300 4 650 2150 597 25 mm mineral wool 63 2016, 2018 G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX MW 3000-4 Pro 3 400 (Y) 1200 53 aluzinc -40...+45 2.3 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Exhaust 600х300 4 1270 3000 833 25 mm mineral wool 73.2 2016, 2018 G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX MW 3200-4 Pro 3 400 (Y) 1200 53 aluzinc -40...+45 2.3 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 600х350 4 1270 3250 903 25 mm mineral wool 73.1 2016, 2018 G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX MW 6500-4 Pro 3 400 1400 55 aluzinc -25...+40 4.5 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 800х500 4 1800 6500 1806 25 mm mineral wool 136 2016, 2018 G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DE 1300-12 Pro 3 400 2700 51 aluzinc -25...+40 17.95 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 400х200 - 12320 1275 354 50 mm mineral wool 56 2016, 2018 - 0.55 12000 17.4 0.32 G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DE 2500-18 Pro 3 400 2690 54 aluzinc -25...+40 27.05 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 500х300 - 18620 2500 695 50 mm mineral wool 61 2016, 2018 - 1.05 18000 26.0 0.62 G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DE 3300-21 Pro 3 400 2730 57 aluzinc -25...+40 32.4 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 600х350 - 22330 3350 931 50 mm mineral wool 91 2016, 2018 - 2.4 21000 30.0 1.33 G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DW 1200-4 Pro 3 400 2700 51 aluzinc -25...+40 0.55 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 400х200 4 320 1200 333 50 mm mineral wool 57 2016, 2018 G4 (Option: F7) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DW 2300-4 Pro 3 400 2690 54 aluzinc -25...+40 1.05 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 500х300 4 620 2350 653 50 mm mineral wool 63 2016, 2018 G4 (Option: F7) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DW 3200-4 Pro 3 400 2730 57 aluzinc -25...+40 2.4 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 600х350 4 1330 3260 906 50 mm mineral wool 94 2016, 2018 G4 (Option: F7) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DW 4100-3 Pro 3 400 2840 75 aluzinc -25...+70 4.3 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 700х400 3 2300 4100 1139 50 mm mineral wool 110 2016, 2018 G4 (Option: F7) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Freshbox E-100 ERV black
Speed I
1 230 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 30 8 - - - G4, F8 (Option: F8 C, H13) - - - - - I -20...+40 10 counter-flow enthalpy 100 A 31 electric preheating Filter replacement indication, Timer, Weekly schedule LCD 13 G4 90 700 - 0.4 3.6 12 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E-100 ERV black
Speed II
1 230 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 60 17 - - - G4, F8 (Option: F8 C, H13) - - - - - II -20...+40 10 counter-flow enthalpy 100 A 31 electric preheating Filter replacement indication, Timer, Weekly schedule LCD 27 G4 86 700 - 0.4 3.6 21 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E-100 ERV black
Speed III
1 230 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 100 28 - - - G4, F8 (Option: F8 C, H13) - - - - - III -20...+40 10 counter-flow enthalpy 100 A 31 electric preheating Filter replacement indication, Timer, Weekly schedule LCD 39 G4 83 700 - 0.4 3.6 45 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
BlauFlex Iso N 127/7.6 - - - - - - - - - - for round air ducts - - - - - - - - - 25 mm mineral wool - - - - - - - - - - - - - - - - - - - - - - - - - - - - - round 127 7600 - air duct - -30...+120 30 3000
BlauFlex Iso N 82/7.6 - - - - - - - - - - for round air ducts - - - - - - - - - 25 mm mineral wool - - - - - - - - - - - - - - - - - - - - - - - - - - - - - round 82 7600 - air duct - -30...+120 30 3000
BlauFlex Iso N 102/7.6 - - - - - - - - - - for round air ducts - - - - - - - - - 25 mm mineral wool - - - - - - - - - - - - - - - - - - - - - - - - - - - - - round 102 7600 - air duct - -30...+120 30 3000
BlauFlex Iso N 182/7.6 - - - - - - - - - - for round air ducts - - - - - - - - - 25 mm mineral wool - - - - - - - - - - - - - - - - - - - - - - - - - - - - - round 182 7600 - air duct - -30...+120 30 3000
BlauFlex Iso N 254/7.6 - - - - - - - - - - for round air ducts - - - - - - - - - 25 mm mineral wool - - - - - - - - - - - - - - - - - - - - - - - - - - - - - round 254 7600 - air duct - -30...+120 30 3000
BlauFlex Iso N 315/7.6 - - - - - - - - - - for round air ducts - - - - - - - - - 25 mm mineral wool - - - - - - - - - - - - - - - - - - - - - - - - - - - - - round 315 7600 - air duct - -30...+120 30 3000
Freshbox E-100
Speed I
1 230 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 30 8 - - - G4, F8 (Option: F8 C, H13) - - - - - I -20...+40 10 counter-flow polystyrene 100 A 31 electric preheating Filter replacement indication, Timer, Weekly schedule LCD 13 G4 98 700 - 0.4 3.6 12 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E-100
Speed II
1 230 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 60 17 - - - G4, F8 (Option: F8 C, H13) - - - - - II -20...+40 10 counter-flow polystyrene 100 A 31 electric preheating Filter replacement indication, Timer, Weekly schedule LCD 27 G4 92 700 - 0.4 3.6 21 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E-100
Speed III
1 230 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 100 28 - - - G4, F8 (Option: F8 C, H13) - - - - - III -20...+40 10 counter-flow polystyrene 100 A 31 electric preheating Filter replacement indication, Timer, Weekly schedule LCD 39 G4 89 700 - 0.4 3.6 45 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E-100 ERV
Speed I
1 230 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 30 8 - - - G4, F8 (Option: F8 C, H13) - - - - - I -20...+40 10 counter-flow enthalpy 100 A 31 electric preheating Filter replacement indication, Timer, Weekly schedule LCD 13 G4 90 700 - 0.4 3.6 12 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E-100 ERV
Speed II
1 230 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 60 17 - - - G4, F8 (Option: F8 C, H13) - - - - - II -20...+40 10 counter-flow enthalpy 100 A 31 electric preheating Filter replacement indication, Timer, Weekly schedule LCD 27 G4 86 700 - 0.4 3.6 21 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E-100 ERV
Speed III
1 230 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 100 28 - - - G4, F8 (Option: F8 C, H13) - - - - - III -20...+40 10 counter-flow enthalpy 100 A 31 electric preheating Filter replacement indication, Timer, Weekly schedule LCD 39 G4 83 700 - 0.4 3.6 45 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox 100 black
Speed I
1 110-240 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 30 8 - - - G4, F8 (Option: F8 C, H13) - - - - - I -20...+40 10 counter-flow polystyrene 100 A 31 without heating Filter replacement indication, Timer, Weekly schedule LCD 13 G4 98 - - 0.4 - 12 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox 100 black
Speed II
1 110-240 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 60 17 - - - G4, F8 (Option: F8 C, H13) - - - - - II -20...+40 10 counter-flow polystyrene 100 A 31 without heating Filter replacement indication, Timer, Weekly schedule LCD 27 G4 92 - - 0.4 - 21 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox 100 black
Speed III
1 110-240 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 100 28 - - - G4, F8 (Option: F8 C, H13) - - - - - III -20...+40 10 counter-flow polystyrene 100 A 31 without heating Filter replacement indication, Timer, Weekly schedule LCD 39 G4 89 - - 0.4 - 45 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox 100 ERV
Speed I
1 110-240 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 30 8 - - - G4, F8 (Option: F8 C, H13) - - - - - I -20...+40 10 counter-flow enthalpy 100 A 31 without heating Filter replacement indication, Timer, Weekly schedule LCD 13 G4 96 - - 0.4 - 12 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox 100 ERV
Speed II
1 110-240 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 60 17 - - - G4, F8 (Option: F8 C, H13) - - - - - II -20...+40 10 counter-flow enthalpy 100 A 31 without heating Filter replacement indication, Timer, Weekly schedule LCD 27 G4 89 - - 0.4 - 21 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox 100 ERV
Speed III
1 110-240 2200 - polymer-coated steel - - 50/60 wall mounting - - yes - - - - - - 100 28 - - - G4, F8 (Option: F8 C, H13) - - - - - III -20...+40 10 counter-flow enthalpy 100 A 31 without heating Filter replacement indication, Timer, Weekly schedule LCD 39 G4 83 - - 0.4 - 45 Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -