Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Form | Length | Material | Device | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Sectional size | Voltage | Regulator | Air pass | Maximum air flow | SFP | Weight | ErP | Motor IP rating | LED-light power | * |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Aero Chrome 150 | 220-240 | Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 24 | 309 | 40* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 86 | 0.28 | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
BlauPlast FS 110x54/204x60 | - | - | - | - | - | for rectangular air ducts | - | - | - | - | - | - | rectangular | - | plastic | reducer | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 55х110, 60х204 | - | - | - | - | - | - | - | - | - | - |
Slim 125 | 220-240 | White | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 16 | 190 | 34* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 53 | 0.30 | 0.73 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Box 100 | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.26 | - | - | - | 50 | 2500 | - | 240 | Exhaust, Supply | 4.65 | 58 | -25 +50 | C | IPX4 | - | 47 | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RVP 150 | - | - | - | - | 150 | for round air ducts | - | - | - | - | - | - | round | - | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo 250 Light (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.12 | 23 | 170 | 25* | 50 | 756 | min | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | 47 | 0.49 | 6.4 | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Ceileo 250 Light (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.18 | 39 | 260 | 29* | 50 | 1122 | max | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | 72 | 0.54 | 6.4 | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Ceileo 250 Light (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.14 | 25 | 160 | 25* | 60 | 732 | min | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | 44 | 0.56 | 6.4 | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Ceileo 250 Light (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.22 | 50 | 270 | 30* | 60 | 1140 | max | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | 75 | 0.67 | 6.4 | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Bravo Still Chrome 100 | 220-240 | Chrome | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.04 | 5.6 | 70 | 26* | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 19 | 0.29 | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Turbo 315 min | 230 | - | Inline | mixed-flow | 315 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.99 | - | 1420 | - | 50/60 | 2115 | - | - | Exhaust, Supply | 11.7 | 227 | 60 | – | IPX4 | 1 | 41 | - | - | - | - | 394 | - | - | 2018 | IP44 | - | - |
Turbo 315 max | 230 | - | Inline | mixed-flow | 315 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 1.42 | - | 1750 | - | 50/60 | 2505 | - | - | Exhaust, Supply | 11.7 | 315 | 60 | – | IPX4 | 1 | 52 | - | - | - | - | 486 | - | - | 2018 | IP44 | - | - |
BlauPlast RR 125/2 | - | - | - | - | 125 | - | - | - | - | - | - | - | round | 2000 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 465x124T | - | - | door mounting | - | - | - | - | - | - | - | - | - | rectangular | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Aero Gold 100 | 220-240 | Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.085 | 14 | 102 | 38* | 50 | 2300 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 28 | 0.49 | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Q-Matic 100 | 220-240 | White | ceiling mounting, wall mounting | - | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.056 | 11 | 90 | 25* | 50 | 2300 | - | - | - | - | - | - | - | IP24 | - | - | - | - | - | - | 25 | 0.4 | 0.63 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Quatro Hi-Tech Gold 100 (127-220V/60Hz) | 127 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.115 | 10 | 82 | 33* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 23 | 0.44 | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Quatro Hi-Tech Gold 100 (127-220V/60Hz) | 220 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.054 | 9 | 82 | 33* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 23 | 0.40 | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Extero 150 50 Hz |
230 | - | Inline | centrifugal | 150 | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | 0.42 | - | 630 | - | 50 | 2400 | - | - | Exhaust | - | 96 | +55 | B | IPX4 | 1 | 58 | - | - | - | - | 175 | - | 4.5 | 2018 | IP44 | - | - |
Extero 150 60 Hz |
230 | - | Inline | centrifugal | 150 | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | 0.44 | - | 650 | - | 60 | 2270 | - | - | Exhaust | - | 100 | +55 | B | IPX4 | 1 | 58 | - | - | - | - | 181 | - | 4.5 | 2018 | IP44 | - | - |
Decor 140x300Rs | - | - | wall mounting | rectangular flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | manual | 0.0128 | - | - | - | - | - | - | - |
BlauPlast RSV 200 | - | - | - | - | 200 | for round air ducts | - | - | - | - | - | - | round | 60 | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo 200 (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 20 | 130 | 24* | 50 | 714 | min | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | 36 | 0.55 | 5.3 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Ceileo 200 (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 29 | 210 | 27* | 50 | 1026 | max | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | 58 | 0.50 | 5.3 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Ceileo 200 (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.11 | 21 | 130 | 24* | 60 | 588 | min | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | 36 | 0.58 | 5.3 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Ceileo 200 (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.15 | 34 | 225 | 28* | 60 | 936 | max | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | 63 | 0.54 | 5.3 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Aero Still Vintage 125 | 220-240 | Vintage | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 9.4 | 158 | 31 | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 44 | 0.21 | - | - | - | - | - |
Turbo 125 min | 230 | - | Inline | mixed-flow | 125 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.11 | - | 230 | - | 50/60 | 1535 | - | - | Exhaust, Supply | 1.79 | 25 | 60 | B | IPX4 | 1 | 29 | - | - | - | - | 64 | - | - | - | IP44 | - | - |
Turbo 125 max | 230 | - | Inline | mixed-flow | 125 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.13 | - | 345 | - | 50/60 | 2265 | - | - | Exhaust, Supply | 1.79 | 29 | 60 | B | IPX4 | 1 | 34 | - | - | - | - | 96 | - | - | - | IP44 | - | - |
BlauPlast RR 200/0.35 | - | - | - | - | 200 | - | - | - | - | - | - | - | round | 350 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 155x155/100HK | - | - | wall mounting, outdoor mounting | round flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | 0.008 | - | - | - | - | - | - | - |
Ducto Power Plus 150 min | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.103 | 22 | 285 | 38* | 50 | 2300 | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | 79 | 0.28 | 1.3 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Ducto Power Plus 150 max | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.109 | 25 | 375 | 41* | 50 | 2600 | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | 104 | 0.24 | 1.3 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Trio One 100 | - | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.05 | 8 | 95 | 27 | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | 220-240 | - | - | 26 | 0.3 | 0.45 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Quatro Hi-Tech 125 (127-220V/60Hz) | 127 | Hi-Tech | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.119 | 16 | 170 | 35* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.34 | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Quatro Hi-Tech 125 (127-220V/60Hz) | 220 | Hi-Tech | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.102 | 15 | 170 | 35* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.32 | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Box-D 125 L (50 Hz) | 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.34 | - | - | - | 50 | 2300 | - | 225 | Exhaust | 2.9 | 56 | -25 +45 | C | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - |
Box-D 125 L (60 Hz) | 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.35 | - | - | - | 60 | 2570 | - | 240 | Exhaust | 2.9 | 58 | -25 +45 | C | IPX4 | 1 | 44 | - | - | - | - | - | - | - | - | - | - | - |