Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Heating | Form | Length | Material | Device | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Max. air flow at air flow direction (perpendicular air flow) | Max. air flow at air flow direction (direct air flow) | Heat exchanger type | Heat exchanger material | Sound pressure level at 1 m | Sound pressure level at 3 m | Outdoor sound pressure attenuation | Regeneration efficiency | Insulation class | Transported air temperature | Current | Connected air duct diameter | Connected air duct size | Transported air temperature | Number of water coil rows | Humidity recovery efficiency | Insulation | Heat recovery efficiency | Total unit power | Sound pressure level at a distance of 1 m | Operating temperature range | Voltage | Max. unit power without an electric heater | Reheater power consumption | Insulation thikness | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Maximum air flow | Bypass | Extract filter | Supply filter | Air speed | Maximum operating pressure | Motor IP rating | Max. power without electric heater | Max. unit power | Max. unit current without electric heater | Max. unit current | Max. unit power with electric heater | Max. unit current with electric heater | Current | Preheater power consumption | Sound pressure level at 3 m in accordance with ISO 3741:2004 | Electric heater current | Remote control panel | Functions | * | Motor max. power | ** | Transported air temperature | Perm. amb. temp. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Box-FI 70x40 6D | 400 | - | Inline | centrifugal | - | for rectangular air ducts | 700 | 400 | galvanized steel | no | no | yes | - | - | - | - | - | 2.3 | - | 4050 | - | 50 | 890 | - | - | Exhaust, Supply | - | 1150 | - | - | IPX4 | 3 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | -20...+70 | - | - | - | - | - | - | - | - | - | - | - | 1125 | - | 99 | 2018 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox 100 ERV Speed I |
110-240 | - | wall mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | - | - | - | - | 30 | - | 50/60 | 2200 | I | - | - | 31 | - | - | A | - | 1 | - | - | - | counter-flow | enthalpy membrane | - | - | - | - | - | - | - | 100 | - | -20...+40 | - | - | - | 96 | - | - | - | - | - | - | 10 | 8 | - | - | - | - | - | - | G4 | G4, F8 (Option: F8 C, H13) | - | - | - | 12 | - | 0.4 | - | - | - | - | - | 13 | - | LCD | Filter replacement indication, Timer, Weekly schedule | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
Freshbox 100 ERV Speed II |
110-240 | - | wall mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | - | - | - | - | 60 | - | 50/60 | 2200 | II | - | - | 31 | - | - | A | - | 1 | - | - | - | counter-flow | enthalpy membrane | - | - | - | - | - | - | - | 100 | - | -20...+40 | - | - | - | 89 | - | - | - | - | - | - | 10 | 17 | - | - | - | - | - | - | G4 | G4, F8 (Option: F8 C, H13) | - | - | - | 21 | - | 0.4 | - | - | - | - | - | 27 | - | LCD | Filter replacement indication, Timer, Weekly schedule | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
Freshbox 100 ERV Speed III |
110-240 | - | wall mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | - | - | - | - | 100 | - | 50/60 | 2200 | III | - | - | 31 | - | - | A | - | 1 | - | - | - | counter-flow | enthalpy membrane | - | - | - | - | - | - | - | 100 | - | -20...+40 | - | - | - | 83 | - | - | - | - | - | - | 10 | 28 | - | - | - | - | - | - | G4 | G4, F8 (Option: F8 C, H13) | - | - | - | 45 | - | 0.4 | - | - | - | - | - | 39 | - | LCD | Filter replacement indication, Timer, Weekly schedule | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
Tower-H EC 630 | 400 | - | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | - | - | - | - | 4.66 | - | 18270 | - | 50/60 | 1450 | - | - | Exhaust | - | 2973 | -25...+55 | – | IPX4 | 3 | 71 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 5075 | - | 101 | 2018 | - | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro 150 60 Hz | 230 | - | Inline | centrifugal | 150 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | - | 0.37 | - | 505 | - | 60 | 2840 | - | - | Exhaust, Supply | - | 84 | -25...+50 | – | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 140 | - | 2.45 | 2018 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro 150 50 Hz | 230 | - | Inline | centrifugal | 150 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | - | 0.35 | - | 460 | - | 50 | 2725 | - | - | Exhaust, Supply | - | 80 | -25...+55 | B | IPX4 | 1 | 42 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 128 | - | 2.45 | 2018 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Primo EC 250 | 230 | - | Inline | mixed-flow | - | for round air ducts | - | - | galvanized steel | yes | no | yes | - | - | - | - | - | - | 168 | 1750 | - | 50 | 3282 | - | - | Exhaust, Supply | 9.8 | - | - | - | IPX4 | 1 | 48 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 486 | - | - | 2018 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | 1.34 | - | - | - | - | - | - | - | - | -25...+55 | - |
KOMFORT Roto EC SE 600 S21 | 230 | - | - | - | - | - | - | - | painted steel | yes | - | - | - | - | - | - | - | - | - | 670 | - | 50/60 | 3230 | - | - | - | - | - | - | A | - | 1 | 35 | - | - | rotary | aluminum | - | - | - | - | - | - | - | 200 | - | -25…+40 | - | - | 40 mm mineral wool | 81–89 | - | - | - | - | - | 2800 | - | 186 | - | 92 | 2016, 2018 | - | - | - | G4 | G4, F7 | - | - | - | 405 | 3205 | 2.6 | 14.8 | - | - | - | - | - | 12.2 | - | - | Heat recovery efficiency is specified in compliance with EN 13141-7. | - | - | - | - |
S-Vent 500х229-5.5-8D | 400 | - | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 14.8 | - | 11550 | - | 50 | 700 | - | - | Exhaust, Supply | 85 | 5500 | +60 | - | IP54 | 3 | 72 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3209 | - | - | - | - | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box EC 50x25-1 | 230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | yes | no | - | - | - | - | - | - | - | - | 1590 | - | 50/60 | 2500 | - | - | Exhaust, Supply | 15.7 | 252 | - | – | IPX4 | - | 45 | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+50 | - | - | - | - | - | - | - | - | - | - | - | 442 | - | - | 2018 | 1590 | 442 | - | - | - | - | - | IP54 | - | - | - | - | - | - | 1.85 | - | - | - | - | - | - | - | - | - | - |
BlauAIR RV 3500 | 380-480 | - | floor mounting, outdoor mounting | - | - | for rectangular air ducts | - | - | aluzinc | yes | yes | yes | - | - | - | - | - | - | - | 3500 | - | 50/60 | 2400 | - | - | Supply and exhaust | - | 2x1240 | - | - | IP34 | 3 | 35 | - | - | - | - | - | - | - | - | B | - | - | - | - | -25...+40 | - | - | - | - | - | - | - | - | - | - | - | - | - | 405 | - | - | - | - | ePM1 ≥ 50% (ISO 16890) | F7 (EN 779) | - | - | IP54 | - | - | - | 3.95 | - | - | - | - | - | - | - | - | - | - | - | - | -35...+50 |
KOMFORT Roto EC LW 2000-2 S17 | 230 | - | - | - | - | - | - | - | aluzinc | - | - | - | - | - | - | - | - | - | - | 2250 | - | 50/60 | 3000 | - | - | - | - | - | - | - | - | 1 | 64 | - | - | rotary | aluminum | - | - | - | - | - | - | - | 500x300 | - | -25...+40 | - | - | 25 mm mineral wool | 68–93 | - | - | - | - | - | - | - | 625 | - | - | 2016, 2018 | - | - | - | G4 | G4 | - | - | - | - | - | - | - | 1070 | 5 | - | - | - | - | - | - | - | 2 items x 448 | - | - | - |
Iso-V ЕС 500 | 400 | - | Inline | centrifugal | - | for round air ducts | - | - | - | yes | yes | yes | - | - | - | - | - | 2.1 | - | - | - | 50/60 | 1350 | - | - | Exhaust, Supply | 43.0 | 1320 | -25 +50 | - | IPX4 | 3 | 45 | 10450 | 9928 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2018 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Aero Chrome 150 | 220-240 | Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 24 | 309 | 40* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 86 | 0.28 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - |
DECOR 81x136 | - | - | - | - | - | for rectangular air ducts | - | - | - | - | - | - | - | rectangular | - | plastic | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BLAUBOX DW 1200-4 Pro | 400 | - | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for rectangular air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | - | - | 1200 | - | 50 | 2700 | - | - | Supply | - | - | - | - | - | 3 | 51 | - | - | - | - | - | - | - | - | - | -25...+40 | 0.55 | - | 400х200 | - | 4 | - | 50 mm mineral wool | - | 320 | - | - | - | - | - | - | 333 | - | 57 | 2016, 2018 | - | - | - | - | G4 (Option: F7) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 300 2D 50 Hz |
400 | - | wall mounting | axial | 300 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 2310 | - | 50 | 2350 | - | - | Exhaust, Supply | - | 145 | - | - | IPX4 | 3 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | - | - | - | 642 | - | 5.4 | - | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | 0.25 | - | - | - | - | - | - | - | - | - | - |
Axis-Q 300 2D 60 Hz |
400 | - | wall mounting | axial | 300 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 2390 | - | 60 | 2570 | - | - | Exhaust, Supply | - | 165 | - | - | IPX4 | 3 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | - | - | - | 664 | - | 5.4 | - | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | 0.29 | - | - | - | - | - | - | - | - | - | - |
Slim 125 | 220-240 | White | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 16 | 190 | 34* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 53 | 0.30 | 0.73 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - |
KOMFORT EC DBW 550-E R S21 | 230 | - | ceiling mounting | - | - | - | - | - | aluzinc | - | - | - | - | - | - | - | - | - | - | 620 | - | 50/60 | 3100 | - | - | Supply and exhaust | - | - | - | A | - | 1 | 30 | - | - | counter-flow | enthalpy membrane | - | - | - | - | - | - | - | 200 | - | -25...+40 | 2 | - | 20 mm mineral wool | 69...87 | - | - | - | - | - | - | - | 172 | - | 68 | - | - | - | yes | G4 | G4 (Option: F7) | - | - | - | - | 297 | - | 2.4 | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauFlex Iso N 254/7.6 | - | - | - | - | 254 | for round air ducts | - | - | - | - | - | - | - | round | 7600 | - | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 mm mineral wool | - | - | - | -30...+120 | - | - | - | - | - | - | - | - | - | - | - | - | - | 30 | 3000 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-V 310 4E (60 Hz) | 230 | - | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 0.87 | - | 2425 | - | 60 | 1740 | - | - | Exhaust | 20 | 195 | -25…+50 | - | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 674 | - | - | – | - | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-V 310 4E (50 Hz) | 230 | - | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 0.64 | - | 2265 | - | 50 | 1420 | - | - | Exhaust | 20 | 141 | -25…+50 | - | IPX4 | 1 | 47 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 629 | - | - | 2018 | - | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Сentro-M 315 max (50 Hz) | 220-240 | - | Inline | centrifugal | 315 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 1.34 | - | 1920 | - | 50 | 2720 | - | - | Exhaust, Supply | - | 295 | - | - | IPX4 | 1 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+45 | - | - | - | - | - | - | - | - | - | - | - | 533 | - | 8.8 | 2018 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Сentro-M 315 max (60 Hz) | 220-240 | - | Inline | centrifugal | 315 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 1.8 | - | 1980 | - | 60 | 2780 | - | - | Exhaust, Supply | - | 413 | - | - | IPX4 | 1 | 55 | - | - | - | - | - | - | - | - | - | - | - | - | - | -25…+45 | - | - | - | - | - | - | - | - | - | - | - | 550 | - | 8.8 | - | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
CIVIC EC DBE2 500 S21 V.2 | 230 | - | ceiling mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | electric preheating, electric reheating | - | - | - | - | - | - | 510 | - | 50/60 | - | - | - | Supply and exhaust | 96 | - | - | A+ | - | 1 | 34 | - | - | counter-flow | polystyrene | - | - | - | - | - | -25...+40 | - | 250 | - | - | - | - | - | 83…96* | - | 44 | - | - | 238 | 700 | - | 142 | - | - | - | - | - | - | - | - | - | - | - | - | - | 1.7 | - | - | 12.6 | - | 1050 | - | - | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
Iso-Mix-E 450-4D | 400 | - | Inline | mixed-flow | 450 | for round air ducts | - | - | polymer-coated steel | no | no | yes | - | - | - | - | - | 3.43 | - | 6510 | - | 50 | 1490 | - | - | Exhaust, Supply | 51 | 1230 | - | - | IPX4 | 3 | 59 | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+60 | - | - | - | - | - | - | - | - | - | - | - | 1808 | - | - | 2016 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
VENTO A50-1 S (1 speed) | 220-240 | - | wall mounting | - | - | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.021 | - | 26 | - | 50 | 599 | - | - | - | - | 3.68 | - | A | IP24 | - | - | - | - | - | - | 24 | 14 | 18 | ≤ 90 | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Mechanical | - | - | - | - | - | - |
VENTO A50-1 S (2 speed) | 220-240 | - | wall mounting | - | - | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.026 | - | 53 | - | 50 | 1155 | - | - | - | - | 4.83 | - | A | IP24 | - | - | - | - | - | - | 34 | 24 | 18 | ≤ 90 | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Mechanical | - | - | - | - | - | - |
Box-I EC 30x15-1 max | 230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | yes | no | yes | - | - | - | - | - | 0.80 | - | - | - | 50/60 | 3500 | - | 665 | Exhaust, Supply | 10.8 | 101 | -25...+50 | B | IPX4 | 1 | 30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2018 | - | 185 | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT ERV D 200 S4 | 230 | - | ceiling mounting, flush mounting | - | - | - | - | - | polymer-coated steel | no | - | - | - | - | - | - | - | - | - | 280 | - | 50 | 2840 | - | - | - | - | 141 | - | D | - | 1 | 49 | - | - | cross-flow | enthalpy membrane | - | - | - | - | - | - | - | 100 | - | -5...+40 | - | 27...47 | 5-10 mm, expanded polyurethane | 72...87 | - | - | - | - | - | - | - | 78 | - | 24 | 2016 | - | - | - | G4 | G4 + F8 (PM2.5 > 93 %) | - | - | - | - | - | - | - | - | - | 0.63 | - | - | - | - | - | - | - | - | - | - |