Description
Description
FEATURES

Ventilation units for efficient supply ventilation in various premises.Controllable air supply, heating and filtration.BMS connection via ModBUS RTU.

 

DESIGN

Steel casing covered with aluzinc coating internally filled with 30 mm heat- and sound-insulating layer made of mineral wool.Mounting brackets with anti-vibration rubber. Service panel ensures easy access to the internals.Blaubox EC MW 700 is compatible with round ducts.

 
Blaubox EC MW 700

Blaubox EC MW 700

Blaubox EC MW 1000 … 4000

FANS

Efficient external rotor EC-motors and centrifugal impellers with backward curved blades.EC-motors are featured with high performance, low noise level and totally controllable speed range.Dynamically balanced impeller.

AIR FILTRATION

Panel Coarse 90% (G4) filter for supply air purification.Panel ePM10 70% (F7) filter is available as an option.

AIR HEATER

The unit is equipped with a water heater. Integrated frost protection.

MOUNTING

The unit is suitable for indoor mounting on the floor, ceiling mounting or wall mounting with fixing brackets in any mounting position, except for the vertical one with air flow downwards. The correct mounted unit must provide free access to the service panel.

CONTROL AND AUTOMATION

The units are equipped with an S31 integrated automation control system. Remote control panels are not included in the delivery set and ordered separately.

  AUTOMATION FUNCTIONS
Functions Description
Vired control panel
S30
Vired control panel
S32
Unit on / off +
Fan speed control and setting +
Filter clogging indication and control Pressure sensor
Week schedule +
Electric heater protection with auto restart +
Electric heater protection with manual restart +
Supply temperature control +
Outer temperature sensor +
Water heater frost protection +
Return temperature sensor +
Air damper control +
Alarm indication +
BMS Connection ModBUS (RTU)
Humidity sensor 0-10V or NO
CO2 Sensor 0-10V or NO
Exhaust fan control on / off
Three-way valve control +
Circulation pump control +
Condensing unit control 0-10V
Option: function is available when purchasing the appropriate accessory (see the"Accessories" section).
Characteristics
Characteristics
Parameter Blaubox EC MW 2000 S31 Measurement unit
Voltage 230 V
Phase 1 ˜
Frequency 50 Hz
Max. unit power 387 W
Max. unit current 1.7 A
Maximum air flow 2150 m³/h
Number of water coil rows 4 -
Sound pressure level at 3 m 53 dBА
Water coil connection diameter 1 in
Insulation 30 mm mineral wool mm
Max. water temperature 150 °С
Transported air temperature -30…+40 °С
Filter Coarce 90% / G4 (option: ePM1 70% / F7) -
EC motor yes -
Weight 45 kg
Connected air duct diameter 500 x 300 mm
Casing material aluzinc -
Outdoor mounting no -
Air duct for rectangular air ducts -
Design centrifugal -
Type Supply -
Mounting ceiling mounting, wall mounting, floor mounting -
ErP 2018 -
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
Blaubox EC MW - user's manual (pdf 2.39Mb)
Blaubox EC MW - image (png 451.38Kb)
Blaubox EC MW - data sheet (pdf 1.02Mb)
Automatic control system (S30, S31, S32) - user's manual (pdf 3.96Mb)
Designation key
Designation key
Series Motor type Heater type Rated air flow [m³/h] Service side Control
Blaubox: supply air unit EC: electronically commutated motor MW: water 700; 1000; 1500; 2000; 3000; 4000 L: left
R: right
S31
Accessories
Accessories
    Blaubox EC MW 2000
Panel filter G4 FP 636х376х48 Coarse 90% / G4
Panel filter F7 FP 636х376х48 ePM1 70% / F7
Flexible anti-vibration connector EVA 50x30
Silencer SD 50x30
Air damper SL 50x30
Air damper electric actuator TF230 / TF24
Overall dimensions
Overall dimensions

Model Overall dimensions [mm]
H H1 H2 L L1 L2 W W1 W2 W3
Blaubox EC MW 2000 S31 440 300 318 900 770 65 700 754 847 500
Additional diagrams
Additional diagrams
HOW TO USE WATER HEATER DIAGRAMS
Air Speed. Starting from 1500 m³/h on the air flow scale draw a vertical line ➀ till the air speed axis which makes about 2.25 m/s.Supply air temperature. Prolong the line ➀ up to the point where it crosses the outside air temperature (blue curve), e.g. -5 °C; then draw a horizontal line ➁ from this point to the left till crossing water in/out temperature curve (70/50 °C). From this point draw a vertical line ➂ to the supply air temperature axis on top of the graphic (+38 °C). Heating coil capacity. Prolong the line ➀ up to the point where it crosses the outside air temperature -15 °C (red curve) and draw a horizontal line ➃ from this point to the right until it crosses water in/out temperature curve (70/50 °C), from here draw a vertical line ➄ up to the scale representing the heating coil capacity (30 kW).Water flow. Prolong the line ➄ down to water flow axis at the bottom of the graphic ➅ (1750 kg/h).Water pressure drop. Draw the line ➆ from the point where line ➅ crosses the black curve to the pressure drop axis. (15 kPa).