Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy

Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Single-room reversible units Vento
  • Single-room units Freshbox
  • Single-room ventilation units Civic
  • Single-room ventilation units Hybrid
  • Single-room reversible units Solo
  • Single-room ventilation units Freshpoint
Additionally
Show ×
Voltage
Functions
Remote control panel
Heating
Casing material
Mounting
Hide filters
Fault
%
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Print version
Search results
Selected 168 products
Mode VoltageMountingAir ductCasing materialEC motorHeatingCurrentPowerMaximum air flowFrequencyRPMSpeedTypeWeight PowerSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialElectric heater powerSound pressure level at 1 mSound pressure level at 3 mOutdoor sound pressure attenuationRegeneration efficiencyTransported air temperature Connected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeFilterTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140Regeneration efficiency in accordance with DIBt LÜ-A 20InsulationHeat recovery efficiencySound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionInsulation thiknessMaximum air flowSFPMaximum air flowExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeMax. power without electric heaterMax. unit current without electric heaterMax. unit current with electric heaterCurrentPreheater power consumptionSound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Heat exchanger typeRemote control panelFunctionsIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8********
CIVIC EC DB 1000 S21 V.2 230 ceiling mounting - polymer-coated steel yes without heating - - 1000 50/60 - - Supply and exhaust 252 - A+ - 1 24 counter-flow polystyrene - - - - - -25...+40 315 - - - - - - - 83…93* 34 - 267 - - 278 - - - - - - - 1.85 - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
VENTO Ergo A50 Pro
(1 speed)
- wall mounting 150 - - - 0.024 - 21 50/60 610 - - - 4.5 A IP24 - - - - - 22 13 40 ≤ 88 - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - -
VENTO Ergo A50 Pro
(2 speed)
- wall mounting 150 - - - 0.026 - 32 50/60 800 - - - 5 A IP24 - - - - - 29 20 40 ≤ 88 - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - -
VENTO Ergo A50 Pro
(3 speed)
- wall mounting 150 - - - 0.039 - 50 50/60 1450 - - - 7 A IP24 - - - - - 32 23 40 ≤ 88 - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - -
CIVIC EC DBE 500 S21 230 ceiling mounting - polymer-coated steel yes electric preheating - - 510 50/60 1700 - Supply and exhaust 128 - A - 1 24 counter-flow polystyrene - - - - - -25...+40 250 - - - - - - 25 mm, cellular synthetic rubber 74...86* 34 - 170 - - 142 - - G4 G4, F8 (option F8 C + H11) - - - 1.7 10.4 - 1750 - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100 ERV black
Speed I
230 wall mounting - polymer-coated steel yes electric preheating - - 30 50/60 2200 I - 31 - A - 1 - counter-flow enthalpy membrane - - - - - - 100 - - - -20...+40 - - - 90 - - - - 10 8 - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 3.6 - 700 - 13 - - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100 ERV black
Speed II
230 wall mounting - polymer-coated steel yes electric preheating - - 60 50/60 2200 II - 31 - A - 1 - counter-flow enthalpy membrane - - - - - - 100 - - - -20...+40 - - - 86 - - - - 10 17 - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 3.6 - 700 - 27 - - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100 ERV black
Speed III
230 wall mounting - polymer-coated steel yes electric preheating - - 100 50/60 2200 III - 31 - A - 1 - counter-flow enthalpy membrane - - - - - - 100 - - - -20...+40 - - - 83 - - - - 10 28 - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 3.6 - 700 - 39 - - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
CIVIC EC DBE 300 S21 V.2 230 ceiling mounting - polymer-coated steel yes electric preheating - - 300 50/60 - - Supply and exhaust 79 - A+ - 1 34 counter-flow polystyrene - - - - - -25...+40 200 - - - - - - - 83…92* 44 - 204 - - 83 - - - - - - - 1.5 7.7 - 1050 - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
VENTO A50-1 S Pro (1 speed) 220-240 wall mounting 150 - - - 0.021 - 26 50 599 - - - 3.68 A IP24 - - - - - 24 14 18 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - -
VENTO A50-1 S Pro (2 speed) 220-240 wall mounting 150 - - - 0.026 - 53 50 1155 - - - 4.83 A IP24 - - - - - 34 24 18 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - -
Vento Expert A50-1 Pro V.3
(I speed)
100-240 - 160 - yes - 0.035 5 - 50/60 800 I - - - - IP24 - - - - - - - - - - - 15 8 - -20...+40 41/47** - - - - - - - - - 2.4 - - - 4 2 - - - - - 13 4 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - Maximum air flow 40 m³/h with open and closed front panel - -
Vento Expert A50-1 Pro V.3
(II speed)
100-240 - 160 - yes - 0.040 6 - 50/60 1300 II - - - - IP24 - - - - - - - - - - - 35 18 - -20...+40 41/47** - - - - - - - - - 1.44 - - - 10 5 - - - - - 25 16 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - Maximum air flow 40 m³/h with open and closed front panel - -
Vento Expert A50-1 Pro V.3
(III speed)
100-240 - 160 - yes - 0.059 8.5 - 50/60 1900 III - - - - IP24 - - - - - - - - - - - 50 25 - -20...+40 41/47** - - - - - - - - - 1.22 - - - 14 7 - - - - - 37 28 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - Maximum air flow 40 m³/h with open and closed front panel - -
Freshbox E-100
Speed I
230 wall mounting - polymer-coated steel yes electric preheating - - 30 50/60 2200 I - 31 - A - 1 - counter-flow polystyrene - - - - - - 100 - - - -20...+40 - - - 98 - - - - 10 8 - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 3.6 - 700 - 13 - - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100
Speed II
230 wall mounting - polymer-coated steel yes electric preheating - - 60 50/60 2200 II - 31 - A - 1 - counter-flow polystyrene - - - - - - 100 - - - -20...+40 - - - 92 - - - - 10 17 - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 3.6 - 700 - 27 - - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100
Speed III
230 wall mounting - polymer-coated steel yes electric preheating - - 100 50/60 2200 III - 31 - A - 1 - counter-flow polystyrene - - - - - - 100 - - - -20...+40 - - - 89 - - - - 10 28 - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 3.6 - 700 - 39 - - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
CIVIC EC LBE2 500 S21 V.2 230 floor mounting - polymer-coated steel yes electric preheating, electric reheating - - 580 50/60 - - Supply and exhaust 142 - A - 1 38 counter-flow polystyrene - - - - - -25...+40 250 - - - - - - 40 mm mineral wool 75...94* 47 - 370 700 - 161 - - - - - - - 2.5 13.3 - 1050 - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
VENTO A50 S (1 speed) 220-240 wall mounting 150 - - - 0.021 - 26 50 599 - - - 3.68 A IP24 - - - - - 24 14 18 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - -
VENTO A50 S (2 speed) 220-240 wall mounting 150 - - - 0.026 - 53 50 1155 - - - 4.83 A IP24 - - - - - 34 24 18 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - -
CIVIC EC DBE2 1000 S21 400 ceiling mounting - polymer-coated steel yes electric preheating, electric reheating - - 1000 50/60 2070 - Supply and exhaust 275 - A+ - 3 24 counter-flow polystyrene - - - - - -25...+40 315 - - - - - - 25 mm, cellular synthetic rubber 83...93* 34 - 260 6300 - 278 - - G4 x 2 G4x2 + (option: F7 x 2) - - - 1.85 20.5 - 6300 - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
CIVIC EC LBE2 500 S21 230 floor mounting - polymer-coated steel yes electric preheating, electric reheating - - 580 50/60 1280 - Supply and exhaust 194±3% - A - 1 25 counter-flow polystyrene - - - - - -25...+40 250 - - - - - - 40 mm mineral wool 75...94* 35 - 230 2800 - 161 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - 1.7 20 - 1400 - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshpoint Eco 160 Pro - wall mounting - - yes without heating - 8 - - - - - - - A - - - сeramic - - - 40 - - - - - - - -30...+50 40 - - up to 92 - - - - - - - 48 - - - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, Carbon dioxide sensor, Air quality sensor, Light sensor D2 S2 - - - -
VENTO V50-1 Pro (1 speed) 220-240 wall mounting 164x164 - - - 0.021 - 26 50 599 - - - 3.68 A IP24 - - - - - 24 14 19 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - -
VENTO V50-1 Pro (2 speed) 220-240 wall mounting 164x164 - - - 0.026 - 53 50 1155 - - - 4.83 A IP24 - - - - - 34 24 19 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - -
CIVIC EC LB 300-E S14 230 floor mounting - polymer-coated steel yes without heating - - 320 50/60 2150 - Supply and exhaust 136±3% - A - 1 21 counter-flow enthalpy membrane - - - - - -25...+40 200 - - - - - - 40 mm mineral wool 73...89* 31 - 125 - - 89 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - 0.9 0.9 - - - - - - - Sensor Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
CIVIC EC LB 300-E S21 230 floor mounting - polymer-coated steel yes without heating - - 320 50/60 2150 - Supply and exhaust 136±3% - A - 1 21 counter-flow enthalpy membrane - - - - - -25...+40 200 - - - - - - 40 mm mineral wool 73...89* 31 - 125 - - 89 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - 0.9 0.9 - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshpoint 200-E 230 wall mounting - - yes electric heating - up to 16 - 50 - - - - - A IP24 1 - - - 100 - 45 - - - - - - - -30...+50 - - - up to 85 - - - - - - - 70 - - - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, Light sensor - - - - - -
VENTO Solar V60 Pro2 (1 speed) - wall mounting - - - - 0.018 2.8 35 - 1150 - - - - A+ IP24 - 24 - - - - - 19 up to 88 - - - - - - - - - - 34 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
VENTO Solar V60 Pro2 (2 speed) - wall mounting - - - - 0.028 4.8 58 - 2100 - - - - A+ IP24 - 29 - - - - - 19 up to 88 - - - - - - - - - - 41 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
CIVIC EC LB 300-E S21 V.2 230 floor mounting - polymer-coated steel yes without heating - - 320 50/60 - - Supply and exhaust 100 - A - 1 37 counter-flow enthalpy membrane - - - - - -25...+40 200 - - - - - - 40 mm mineral wool 73...89* 47 - 96 - - 89 - - - - - - - 0.75 - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Vento Eco A50-4 S Pro (1 speed) 100-240 wall mounting 160 - yes - 0.017 - - 50/60 915 - - - 1.00 - IP24 - - - - - - - - - - - 15 8 - 20(-30**) … +40 41 - - - - - - - - - 0.48 - - - 4 2 - - - - - 21 12 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - Sensor Filter replacement indication, Timer D1 S3*** Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed -
Vento Eco A50-4 S Pro (2 speed) 100-240 wall mounting 160 - yes - 0.025 - - 50/60 1555 - - - 2.10 - IP24 - - - - - - - - - - - 30 15 - 20(-30**) … +40 41 - - - - - - - - - 0.50 - - - 8 4 - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - Sensor Filter replacement indication, Timer D1 S3*** Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed -
Vento Eco A50-4 S Pro (3 speed) 100-240 wall mounting 160 - yes - 0.041 - - 50/60 2330 - - - 4.30 - IP24 - - - - - - - - - - - 50 25 - 20(-30**) … +40 41 - - - - - - - - - 0.62 - - - 14 7 - - - - - 29 20 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - Sensor Filter replacement indication, Timer D1 S3*** Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed -
VENTO inHome W
(1st speed)
100-240 wall mounting 160 - yes - 0.03 - - 50/60 - I - - 1.7 - IP24 - - - - - 20 11 - - - - 15 8 - -20...+40 40 / 44 - - up to 88% - - - - - - 0.82 - - - 4 2 - - - - - - - ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) - - - Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection, Automatic shutters - - - - - -
VENTO inHome W
(2nd speed)
100-240 wall mounting 160 - yes - 0.04 - - 50/60 - II - - 3.0 - IP24 - - - - - 30 21 - - - - 35 15 - -20...+40 40 / 44 - - up to 88% - - - - - - 0.72 - - - 10 4 - - - - - - - ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) - - - Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection, Automatic shutters - - - - - -
VENTO inHome W
(3rd speed)
100-240 wall mounting 160 - yes - 0.05 - - 50/60 - III - - 4.3 - IP24 - - - - - 36 27 - - - - 50 25 - -20...+40 40 / 44 - - up to 88% - - - - - - 0.62 - - - 14 7 - - - - - - - ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) - - - Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection, Automatic shutters - - - - - -
VENTO Eco2 A50 S Pro (1 speed) - wall mounting 160 - - - 0.03 - - 50/60 1030 - - - 2.07 A IP24 - - - - - 22 13 - - - - 15 15 G3 (F8 PM2.5 > 99 %) -20…+50 41 ≤ 92 - - - 100-230 - - - - - - - - 4 4 - - - - - - - - - - Sensor Filter replacement indication, Timer - - - - - -
VENTO Eco2 A50 S Pro (2 speed) - wall mounting 160 - - - 0.049 - - 50/60 1760 - - - 4.15 A IP24 - - - - - 29 20 - - - - 30 30 G3 (F8 PM2.5 > 99 %) -20…+50 41 ≤ 92 - - - 100-230 - - - - - - - - 8 8 - - - - - - - - - - Sensor Filter replacement indication, Timer - - - - - -
VENTO Eco2 A50 S Pro (3 speed) - wall mounting 160 - - - 0.098 - - 50/60 2690 - - - 10.10 A IP24 - - - - - 32 23 - - - - 50 50 G3 (F8 PM2.5 > 99 %) -20…+50 41 ≤ 92 - - - 100-230 - - - - - - - - 14 14 - - - - - - - - - - Sensor Filter replacement indication, Timer - - - - - -
Solo A50 S4 Pro R V.2
(1 speed)
- - - - - - - - - 50/60 - I - - 0.70 A IP24 - 16 - - - - - - ≤ 85 - - 25 - - -15…+40 - - - - - 220-240 - - - - 0.20 - - - 7 - - - - 0.020 - - - - - Ceramic - - - - - - - -
Solo A50 S4 Pro R V.2
(2 speed)
- - - - - - - - - 50/60 - II - - 2.30 A IP24 - 29 - - - - - - ≤ 85 - - 50 - - -15…+40 - - - - - 220-240 - - - - 0.33 - - - 14 - - - - 0.034 - - - - - Ceramic - - - - - - - -
Vento Expert A50-1 S10 Pro
(1 speed)
100-240 - 160 - yes - 0.025 - - 50/60 800 - - - 3.61 - IP24 - - - - - - - - - -20…+40 - 15 8 - - 42 - - - - - - - - - 1.73 - - - 4 2 - - - - - 20 11 G3 (Option: F7 PM2,5 > 99 %*) up to 93 - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - Maximum air flow 40 m³/h - - -
Vento Expert A50-1 S10 Pro
(2 speed)
100-240 - 160 - yes - 0.030 - - 50/60 1300 - - - 4.15 - IP24 - - - - - - - - - -20…+40 - 30 15 - - 42 - - - - - - - - - 1.00 - - - 8 4 - - - - - 27 18 G3 (Option: F7 PM2,5 > 99 %*) up to 93 - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - Maximum air flow 40 m³/h - - -
Vento Expert A50-1 S10 Pro
(3 speed)
100-240 - 160 - yes - 0.039 - - 50/60 1900 - - - 5.20 - IP24 - - - - - - - - - -20…+40 - 50 25 - - 42 - - - - - - - - - 0.75 - - - 14 7 - - - - - 30 21 G3 (Option: F7 PM2,5 > 99 %*) up to 93 - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - Maximum air flow 40 m³/h - - -
VENTO inHome mini
(1st speed)
100-240 wall mounting 100 - yes - 0.02 - - 50/60 - I - - 1.0 - IP24 - - - - - 20 10 - - - - 8 4 - -15...+40 40 / 44 - - up to 81% - - - - - - 0.90 - - - 2 1 - - - - - - - ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection, Automatic shutters - - - - - -
VENTO inHome mini
(2nd speed)
100-240 wall mounting 100 - yes - 0.03 - - 50/60 - II - - 1.6 - IP24 - - - - - 26 16 - - - - 16 8 - -15...+40 40 / 44 - - up to 81% - - - - - - 0.72 - - - 4 2 - - - - - - - ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection, Automatic shutters - - - - - -
VENTO inHome mini
(3rd speed)
100-240 wall mounting 100 - yes - 0.04 - - 50/60 - III - - 3.0 - IP24 - - - - - 33 23 - - - - 25 13 - -15...+40 40 / 44 - - up to 81% - - - - - - 0.86 - - - 7 3 - - - - - - - ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection, Automatic shutters - - - - - -