Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy

Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Single-room reversible units Vento
  • Single-room units Freshbox
  • Single-room ventilation units Civic
  • Single-room ventilation units Hybrid
  • Single-room reversible units Solo
  • Single-room ventilation units Freshpoint
Additionally
Show ×
Voltage
Functions
Remote control panel
Heating
Casing material
Mounting
Hide filters
Fault
%
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Print version
Search results
Selected 180 products
Mode VoltageMountingAir ductCasing materialEC motorHeatingCurrentMaximum air flowFrequencyRPMSpeedTypeWeight PowerSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialSound pressure level at 1 mSound pressure level at 3 mOutdoor sound pressure attenuationRegeneration efficiencyTransported air temperature Connected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140InsulationHeat recovery efficiencySound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionInsulation thiknessMaximum air flowSFPExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeMax. power without electric heaterMax. unit current without electric heaterMax. unit current with electric heaterPreheater power consumptionSound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Remote control panelFunctionsIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8Power********
Freshbox 100 ERV black
Speed I
110-240 wall mounting - polymer-coated steel yes without heating - 30 50/60 2200 I - 31 - A - 1 - counter-flow enthalpy membrane - - - - - 100 - - -20...+40 - - 96 - - - - 10 8 - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 - - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox 100 ERV black
Speed II
110-240 wall mounting - polymer-coated steel yes without heating - 60 50/60 2200 II - 31 - A - 1 - counter-flow enthalpy membrane - - - - - 100 - - -20...+40 - - 89 - - - - 10 17 - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 - - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox 100 ERV black
Speed III
110-240 wall mounting - polymer-coated steel yes without heating - 100 50/60 2200 III - 31 - A - 1 - counter-flow enthalpy membrane - - - - - 100 - - -20...+40 - - 83 - - - - 10 28 - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 - - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
CIVIC EC LBE2 1200 S21 V.2 400 floor mounting - polymer-coated steel yes electric preheating, electric reheating - 1240 50/60 - - Supply and exhaust 363 - - 3 30 counter-flow polystyrene - - - - -25...+40 400 - - - - 40 mm mineral wool 84…96* 40 - 345 2110 - 344 - - - - - - 2.3 18.7 3150 - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
VENTO A50-1 Pro (1 speed) 220-240 wall mounting 150 - - - 0.021 26 50 599 - - - 3.68 A IP24 - - - - 24 14 18 ≤ 90 - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - Mechanical - - - - - - - -
VENTO A50-1 Pro (2 speed) 220-240 wall mounting 150 - - - 0.026 53 50 1155 - - - 4.83 A IP24 - - - - 34 24 18 ≤ 90 - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - Mechanical - - - - - - - -
Vento Expert A50-1 W V.3
(I speed)
100-240 - 160 - yes - 0.035 - 50/60 800 I - - - - IP24 - - - - - - - - - - 15 8 -20...+40 41/47** - - - - - - - - 2.4 - - 4 2 - - - - 13 4 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S3*** 5.0 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application -
Vento Expert A50-1 W V.3
(II speed)
100-240 - 160 - yes - 0.04 - 50/60 1300 II - - - - IP24 - - - - - - - - - - 30 15 -20...+40 41/47** - - - - - - - - 1.44 - - 8 4 - - - - 25 16 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S3*** 6.0 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application -
Vento Expert A50-1 W V.3
(III speed)
100-240 - 160 - yes - 0.059 - 50/60 1900 III - - - - IP24 - - - - - - - - - - 50 25 -20...+40 41/47** - - - - - - - - 1.22 - - 14 7 - - - - 37 28 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S3*** 8.5 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application -
CIVIC EC DBE2 300 S21 230 ceiling mounting - polymer-coated steel yes electric preheating, electric reheating - 300 50/60 2150 - Supply and exhaust 80 - A - 1 23 counter-flow polystyrene - - - - -25...+40 200 - - - - 25 mm, cellular synthetic rubber 76...88* 33 - 125 1400 - 83 - G4 G4, F8 (option F8 C + H11) - - - 1.3 13.6 1050 - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Pages