Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy

Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Single-room reversible units Vento
  • Single-room units Freshbox
  • Single-room ventilation units Civic
  • Single-room ventilation units Hybrid
  • Single-room reversible units Solo
  • Single-room ventilation units Freshpoint
Additionally
Show ×
Voltage
Functions
Remote control panel
Heating
Casing material
Mounting
Hide filters
Fault
%
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Print version
Search results
Selected 188 products
Mode VoltageMountingAir ductCasing materialEC motorHeatingCurrentPowerMaximum air flowFrequencyRPMSpeedTypeWeight PowerSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialFan powerElectric heater powerSound pressure level at 1 mSound pressure level at 3 mOutdoor sound pressure attenuationRegeneration efficiencyTransported air temperature Connected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140InsulationHeat recovery efficiencySound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionInsulation thiknessMaximum air flowSFPWeightMaximum air flowExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeMax. power without electric heaterMax. unit current without electric heaterMax. unit current with electric heaterPreheater power consumptionSound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Remote control panelFunctionsRemote control panelIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8Power********
Vento Expert A50-1 Pro V.3 BLK
(I speed)
100-240 - 160 - yes - 0.035 5 - 50/60 800 I - - - - IP24 - - - - - - - - - - - - 15 8 -20...+40 41/47** - - - - - - - - 2.4 - - - - 4 2 - - - - 13 4 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - Filter replacement indication, Timer, Humidity sensor, External sensor connection - D1 - - Maximum air flow 40 m³/h with open and closed front panel - -
Vento Expert A50-1 Pro V.3 BLK
(II speed)
100-240 - 160 - yes - 0.040 6 - 50/60 1300 II - - - - IP24 - - - - - - - - - - - - 35 18 -20...+40 41/47** - - - - - - - - 1.44 - - - - 10 5 - - - - 25 16 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - Filter replacement indication, Timer, Humidity sensor, External sensor connection - D1 - - Maximum air flow 40 m³/h with open and closed front panel - -
Vento Expert A50-1 Pro V.3 BLK
(III speed)
100-240 - 160 - yes - 0.059 8.5 - 50/60 1900 III - - - - IP24 - - - - - - - - - - - - 50 25 -20...+40 41/47** - - - - - - - - 1.22 - - - - 14 7 - - - - 37 28 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - Filter replacement indication, Timer, Humidity sensor, External sensor connection - D1 - - Maximum air flow 40 m³/h with open and closed front panel - -
VENTO Expert A100-1 S10 W V.2 (Speed I) 100-240 - 160 - yes - 0.037 - - 50/60 780 - - - - - IP24 - - - - 3.20 - - - - - - - 18 9 -20 … +40 42 - - - - - - - - 1.28 - - - - 5 3 - - - - 23 13 G3 (Option: F7 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 - - Maximum air flow 82 m³/h - - -
VENTO Expert A100-1 S10 W V.2 (Speed II) 100-240 - 160 - yes - 0.046 - - 50/60 1100 - - - - - IP24 - - - - 4.00 - - - - - - - 30 15 -20 … +40 42 - - - - - - - - 0.96 - - - - 8 4 - - - - 27 18 G3 (Option: F7 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 - - Maximum air flow 82 m³/h - - -
VENTO Expert A100-1 S10 W V.2 (Speed III) 100-240 - 160 - yes - 0.071 - - 50/60 1920 - - - - - IP24 - - - - 6.60 - - - - - - - 58 29 -20 … +40 42 - - - - - - - - 0.82 - - - - 16 8 - - - - 40 30 G3 (Option: F7 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 - - Maximum air flow 82 m³/h - - -
VENTO Expert A100-1 S10 W V.2 (MAX) 100-240 - 160 - yes - 0.151 - - 50/60 2940 - - - - - IP24 - - - - 18.00 - - - - - - - 108 54 -20 … +40 42 - - - - - - - - 1.20 - - - - 30 15 - - - - 51 42 G3 (Option: F7 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 - - Maximum air flow 82 m³/h - - -
Freshpoint 200-E L07 230 wall mounting - - yes electric heating - up to 16 - 50/60 - - - - - A IPX4 1 - - - - 100 - 45 - - - - - - -30...+50 - - up to 85 - - - - - - - - 70 - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, Light sensor - - - - - - - -
Freshbox 100 ERV WiFi
Speed I
110-240 - - polymer-coated steel - without heating - - 30 50/60 2200 I - - - A - 1 - counter-flow enthalpy - - - - - - - 100 - - -20...+40 - - 96 - - - - 10 8 - 31 - G4 G4 + F8 (Option: F8 Carbon;
H13 Filter type C)
- - 20 0.4 - - - 13 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox 100 ERV WiFi
Speed II
110-240 - - polymer-coated steel - without heating - - 44 50/60 2200 II - - - A - 1 - counter-flow enthalpy - - - - - - - 100 - - -20...+40 - - 94 - - - - 10 12 - 31 - G4 G4 + F8 (Option: F8 Carbon;
H13 Filter type C)
- - 23 0.4 - - - 20 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox 100 ERV WiFi
Speed III
110-240 - - polymer-coated steel - without heating - - 60 50/60 2200 III - - - A - 1 - counter-flow enthalpy - - - - - - - 100 - - -20...+40 - - 89 - - - - 10 17 - 31 - G4 G4 + F8 (Option: F8 Carbon;
H13 Filter type C)
- - 29 0.4 - - - 27 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox 100 ERV WiFi
Speed IV
110-240 - - polymer-coated steel - without heating - - 75 50/60 2200 IV - - - A - 1 - counter-flow enthalpy - - - - - - - 100 - - -20...+40 - - 85 - - - - 10 21 - 31 - G4 G4 + F8 (Option: F8 Carbon;
H13 Filter type C)
- - 37 0.4 - - - 33 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox 100 ERV WiFi
Speed V
110-240 - - polymer-coated steel - without heating - - 100 50/60 2200 V - - - A - 1 - counter-flow enthalpy - - - - - - - 100 - - -20...+40 - - 83 - - - - 10 28 - 31 - G4 G4 + F8 (Option: F8 Carbon;
H13 Filter type C)
- - 53 0.4 - - - 39 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
CIVIC EC DBE 500 S21 V.2 230 ceiling mounting - polymer-coated steel yes electric preheating - - 510 50/60 - - Supply and exhaust 95 - A+ - 1 34 counter-flow polystyrene - - - - - - -25...+40 250 - - - - - 83…96* 44 - 238 - - 142 - - - - - - - - 1.7 9.3 1050 - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
VENTO Ergo V50 S Pro (1 speed) 100-230 wall mounting 150x150 - - - 0.025 - 11 50/60 808 - - - 4.31 A IP24 - - - - - - 28 19 19 ≤ 88 - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
VENTO Ergo V50 S Pro (2 speed) 100-230 wall mounting 150x150 - - - 0.029 - 24 50/60 1264 - - - 4.92 A IP24 - - - - - - 33 24 19 ≤ 88 - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
VENTO Ergo V50 S Pro (3 speed) 100-230 wall mounting 150x150 - - - 0.035 - 35 50/60 1629 - - - 5.8 A IP24 - - - - - - 39 29 19 ≤ 88 - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
Vento Ergo A85-1 Pro V.3
(1 speed)
- - 150 - yes - 0.034 - 36 50/60 1000 I - - 4.74 - IP24 1 - - - - - - - - - - - - 18 -20...+40 40 - - - 100-240 - - - 10 0.95 - - - - - 5 - - - - 29 19 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 90 - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - -
Vento Ergo A85-1 Pro V.3
(2 speed)
- - 150 - yes - 0.050 - 59 50/60 1500 II - - 6.56 - IP24 1 - - - - - - - - - - - - 30 -20...+40 40 - - - 100-240 - - - 16 0.80 - - - - - 8 - - - - 35 25 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 90 - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - -
Vento Ergo A85-1 Pro V.3
(3 speed)
- - 150 - yes - 0.071 - 85 50/60 2045 III - - 9.65 - IP24 1 - - - - - - - - - - - - 43 -20...+40 40 - - - 100-240 - - - 24 0.82 - - - - - 12 - - - - 44 34 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 90 - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - -
Freshpoint 160-E L1 230 wall mounting - - yes electric heating - up to 22 - 50/60 - - - - - A IPX4 1 - - - - 100 - 42 - - - - - - -30...+50 - - up to 88 - - - - - - - - 57 - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, Light sensor - - - - - - - -
Freshbox 100 ERV black
Speed I
110-240 wall mounting - polymer-coated steel yes without heating - - 30 50/60 2200 I - 31 - A - 1 - counter-flow enthalpy - - - - - - - 100 - - -20...+40 - - 96 - - - - 10 8 - - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 - - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox 100 ERV black
Speed II
110-240 wall mounting - polymer-coated steel yes without heating - - 60 50/60 2200 II - 31 - A - 1 - counter-flow enthalpy - - - - - - - 100 - - -20...+40 - - 89 - - - - 10 17 - - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 - - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox 100 ERV black
Speed III
110-240 wall mounting - polymer-coated steel yes without heating - - 100 50/60 2200 III - 31 - A - 1 - counter-flow enthalpy - - - - - - - 100 - - -20...+40 - - 83 - - - - 10 28 - - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 - - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
CIVIC EC LBE2 1200 S21 V.2 400 floor mounting - polymer-coated steel yes electric preheating, electric reheating - - 1240 50/60 - - Supply and exhaust 363 - - 3 30 counter-flow polystyrene - - - - - - -25...+40 400 - - - - 40 mm mineral wool 84…96* 40 - 345 2110 - 344 - - - - - - - - 2.3 18.7 3150 - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
VENTO A50-1 Pro (1 speed) 220-240 wall mounting 150 - - - 0.021 - 26 50 599 - - - 3.68 A IP24 - - - - - - 24 14 18 ≤ 90 - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - -
VENTO A50-1 Pro (2 speed) 220-240 wall mounting 150 - - - 0.026 - 53 50 1155 - - - 4.83 A IP24 - - - - - - 34 24 18 ≤ 90 - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - -
Vento Expert A50-1 W V.3
(I speed)
100-240 - 160 - yes - 0.035 - - 50/60 800 I - - - - IP24 - - - - - - - - - - - - 15 8 -20...+40 41/47** - - - - - - - - 2.4 - - - - 4 2 - - - - 13 4 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** 5.0 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application -
Vento Expert A50-1 W V.3
(II speed)
100-240 - 160 - yes - 0.04 - - 50/60 1300 II - - - - IP24 - - - - - - - - - - - - 30 15 -20...+40 41/47** - - - - - - - - 1.44 - - - - 8 4 - - - - 25 16 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** 6.0 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application -
Vento Expert A50-1 W V.3
(III speed)
100-240 - 160 - yes - 0.059 - - 50/60 1900 III - - - - IP24 - - - - - - - - - - - - 50 25 -20...+40 41/47** - - - - - - - - 1.22 - - - - 14 7 - - - - 37 28 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** 8.5 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application -
CIVIC EC DBE2 300 S21 230 ceiling mounting - polymer-coated steel yes electric preheating, electric reheating - - 300 50/60 2150 - Supply and exhaust 80 - A - 1 23 counter-flow polystyrene - - - - - - -25...+40 200 - - - - 25 mm, cellular synthetic rubber 76...88* 33 - 125 1400 - 83 - - - G4 G4, F8 (option F8 C + H11) - - - 1.3 13.6 1050 - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Pages