Selected 1001 products
Mode VoltageStyleMountingDesignConnection diameterAir ductWidthHeightCasing materialEC motorOutdoor mountingSound-insulated casingHeatingFormLengthMaterialDeviceCurrentPowerMaximum air flowSound pressure levelFrequencyRPMSpeedHeat recovery efficiencyMaximum air capacityTypeWeight PowerMax. operating temperatureSEC classIngress protection ratingPhaseSound pressure level at 3 mMax. air flow at air flow direction (perpendicular air flow)Max. air flow at air flow direction (direct air flow)Heat exchanger typeHeat exchanger materialElectric heater powerTransported air temperature Electric heater currentCurrentConnected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140Number of water coil rowsInsulationHeat recovery efficiencyTotal unit powerSound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionInsulation thiknessMaximum air flowSFPWeightErPExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeMotor IP ratingPM 2.5 RatioMax. power without electric heaterMax. unit powerMax. unit current without electric heaterMax. unit currentMax. unit power with electric heaterMax. unit current with electric heaterCurrentPreheater power consumptionSound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20LED-light powerRemote control panelFunctionsIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8*Motor max. power*******Max. water temperatureWater coil connection diameter
Iso Box-F 200 G4 230 - ceiling mounting, wall mounting centrifugal 200 for round air ducts - - polymer-coated steel no no yes - - - - - 0.56 - 580 - 50/60 1250 - - - Supply 18.72 123 - C IPX4 1 38 - - - - - - - - - - - -25…+40 - - - - - - - - - - 161 - - 2018 - - - - - 40 - - - - - - - - - - - - - - - - - - - - - - - -
Tower-H EC 630 400 - for roof centrifugal - for round air ducts, for square air ducts - - polymer-coated steel yes yes no - - - - - 4.66 - 18270 - 50/60 1450 - - - Exhaust - 2973 -25...+55 IPX4 3 71 - - - - - - - - - - - - - - - - - - - - - - 5075 - 101 2018 - - - - IP54 - - - - - - - - - - - - - - - - - - - - - - - - -
Tubo 125 220-240 White Inline axial 125 - - - - - - - - - - - - 0.1 16 195 39* 50 2400 - - - Exhaust, Supply - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 54 0.3 - - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - -
Ceileo Compact 200 Light T
(50 Hz, min)
220-240 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.1 20 130 24* 50 714 min - - Exhaust - - - C*** IPX2 - - - - - - - - - - - - - - - - - - - - - - - - 36 0.55 6.4 - - - - - - - - - - - - - - - - - - - 2 х 10 - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - For fans with humidity or motion sensors - - -
Ceileo Compact 200 Light T
(50 Hz, max)
220-240 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.13 29 210 27* 50 1026 max - - Exhaust - - - C*** IPX2 - - - - - - - - - - - - - - - - - - - - - - - - 58 0.50 6.4 - - - - - - - - - - - - - - - - - - - 2 х 10 - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - For fans with humidity or motion sensors - - -
Ceileo Compact 200 Light T
(60 Hz, min)
220-240 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.11 21 130 24* 60 588 min - - Exhaust - - - C*** IPX2 - - - - - - - - - - - - - - - - - - - - - - - - 36 0.58 6.4 - - - - - - - - - - - - - - - - - - - 2 х 10 - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - For fans with humidity or motion sensors - - -
Ceileo Compact 200 Light T
(60 Hz, max)
220-240 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.15 34 225 28* 60 936 max - - Exhaust - - - C*** IPX2 - - - - - - - - - - - - - - - - - - - - - - - - 63 0.54 6.4 - - - - - - - - - - - - - - - - - - - 2 х 10 - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - For fans with humidity or motion sensors - - -
S-Vent 450х203-11.0-4D 400 - floor mounting centrifugal - for rectangular air ducts, for round air ducts - - polymer-coated steel no yes no - - - - - 24 - 19000 - 50 1450 - - - Exhaust, Supply 105 11000 +60 - IP54 3 84 - - - - - - - - - - - - - - - - - - - - - - 5278 - - - - - - - IP54 - - - - - - - - - - - - - - - - - - - - - - - - -
Box-D 100 L (50 Hz) 230 - Inline centrifugal 100 for round air ducts - - galvanized steel no no no - - - - - 0.34 - - - 50 2300 - - 190 Exhaust 2.9 56 -25 +45 C IPX4 1 42 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Box-D 100 L (60 Hz) 230 - Inline centrifugal 100 for round air ducts - - galvanized steel no no no - - - - - 0.35 - - - 60 2570 - - 205 Exhaust 2.9 58 -25 +45 C IPX4 1 43 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Blaubox EC MW 1000 S31 230 - ceiling mounting, wall mounting, floor mounting centrifugal - for rectangular air ducts - - aluzinc yes no - - - - - - - - 920 - 50 - - - - Supply - - - - - 1 48 - - - - - -30…+40 - - 400 x 200 - - - - 4 30 mm mineral wool - - - - - - - - - 35 2018 - - - - - - - 165 - 1.23 - - - - - - Coarce 90% / G4 (option: ePM1 70% / F7) - - - - - - - - - - - 150 1
KOMFORT Roto EC LW 1500-2 S18 230 - - - - - - - aluzinc - - - - - - - - - - 1500 - 50/60 2000 - - - - - - - - - 1 62 - - rotary aluminum - - - - 315 - - -25...+40 - - 25 mm mineral wool 72–95 - - - - - - 417 - 175 2016, 2018 G4 G4 - - - - - - - - 750 3.2 - - - - - - - - - - - - 2 items x 222 - - - - -
Iso-V ЕС 500 400 - Inline centrifugal - for round air ducts - - - yes yes yes - - - - - 2.1 - - - 50/60 1350 - - - Exhaust, Supply 43.0 1320 -25 +50 - IPX4 3 45 10450 9928 - - - - - - - - - - - - - - - - - - - - - - - 2018 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ducto Plus 125 min 220-240 White Inline axial 125 - - - - - - - - - - - - 0.065 10 155 29* 50 1950 min - - Exhaust, Supply - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 43 0.23 0.75 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ducto Plus 125 max 220-240 White Inline axial 125 - - - - - - - - - - - - 0.085 13 215 33* 50 2250 max - - Exhaust, Supply - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 60 0.22 0.75 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Freshbox 100
Speed I
110-240 - wall mounting - - - - - polymer-coated steel yes - - without heating - - - - - - 30 - 50/60 2200 I - - - 31 - - A - 1 - - - counter-flow polystyrene - - - - 100 - - -20...+40 - - - 98 - - - - - 10 8 - - - G4 G4, F8 (Option: F8 C, H13) - - - - 12 - 0.4 - - - - - - 13 - - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - -
Freshbox 100
Speed II
110-240 - wall mounting - - - - - polymer-coated steel yes - - without heating - - - - - - 60 - 50/60 2200 II - - - 31 - - A - 1 - - - counter-flow polystyrene - - - - 100 - - -20...+40 - - - 92 - - - - - 10 17 - - - G4 G4, F8 (Option: F8 C, H13) - - - - 21 - 0.4 - - - - - - 27 - - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - -
Freshbox 100
Speed III
110-240 - wall mounting - - - - - polymer-coated steel yes - - without heating - - - - - - 100 - 50/60 2200 III - - - 31 - - A - 1 - - - counter-flow polystyrene - - - - 100 - - -20...+40 - - - 89 - - - - - 10 28 - - - G4 G4, F8 (Option: F8 C, H13) - - - - 45 - 0.4 - - - - - - 39 - - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - -
Axis-QRA 150
50 Hz
220-240 - wall mounting axial 150 for round air ducts - - polymer-coated steel no no no - - - - - - - 200 - 50 1300 - - - Exhaust, Supply - 36 -30 … +40 - IPX4 1 33 - - - - - - - - - - - - - - - - - - - - - - 56 - 1.91 - - - - - IP44 - - - - - - - 0.26 - - - - - - - - - - - - - - - - -
Axis-QRA 150
60 Hz
220-240 - wall mounting axial 150 for round air ducts - - polymer-coated steel no no no - - - - - - - 205 - 60 1590 - - - Exhaust, Supply - 26 -30 … +40 - IPX4 1 33 - - - - - - - - - - - - - - - - - - - - - - 57 - 1.91 - - - - - IP44 - - - - - - - 0.26 - - - - - - - - - - - - - - - - -
Quatro Platinum 125 (127-220V/60Hz) 127 Platinum ceiling mounting, wall mounting axial 125 - - - - - - - - - - - - 0.119 16 170 35* 60 2400 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 47 0.34 - - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - -
Quatro Platinum 125 (127-220V/60Hz) 220 Platinum ceiling mounting, wall mounting axial 125 - - - - - - - - - - - - 0.102 15 170 35* 60 2400 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 47 0.32 - - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - -
Vento Eco A50-4 S11 Pro (1 speed) 100-240 - wall mounting - - 160 - - - yes - - - - - - - 0.017 - - - 50/60 915 - - - - - 1.00 - - IP24 - - - - - - - - - - - 15 8 20(-30**) … +40 41 - - - - - - - - - - 0.48 - - - - 4 2 - - - - - - - - - - 21 12 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - Sensor Filter replacement indication, Timer D1 S3*** Maximum air flow 40 m³/h - With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - -
Vento Eco A50-4 S11 Pro (2 speed) 100-240 - wall mounting - - 160 - - - yes - - - - - - - 0.025 - - - 50/60 1555 - - - - - 2.10 - - IP24 - - - - - - - - - - - 30 15 20(-30**) … +40 41 - - - - - - - - - - 0.50 - - - - 8 4 - - - - - - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - Sensor Filter replacement indication, Timer D1 S3*** Maximum air flow 40 m³/h - With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - -
Vento Eco A50-4 S11 Pro (3 speed) 100-240 - wall mounting - - 160 - - - yes - - - - - - - 0.041 - - - 50/60 2330 - - - - - 4.30 - - IP24 - - - - - - - - - - - 50 25 20(-30**) … +40 41 - - - - - - - - - - 0.62 - - - - 14 7 - - - - - - - - - - 29 20 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - Sensor Filter replacement indication, Timer D1 S3*** Maximum air flow 40 m³/h - With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - -
Helix 200х80 4Е 230 - floor mounting centrifugal - for rectangular air ducts, for round air ducts - - polymer-coated steel no yes no - - - - - 0.55 - 730 - 50 1430 - - - Exhaust, Supply 6.8 125 -25 +45 B IPX4 - 63 - - - - - - - - - - - - - - - - - - - - - - 203 - - 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - -
Centro-MZ 125
50 Hz
220-240 - ceiling mounting, wall mounting centrifugal 125 for round air ducts - - galvanized steel no no no - - - - - 0.34 - 330 - 50 2820 - - - Supply and exhaust 3.16 78 - C IPX4 1 46 - - - - - - - - - - - -25...+55 - - - - - - - - - - 92 - - 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - -
Centro-MZ 125
60 Hz
220-240 - ceiling mounting, wall mounting centrifugal 125 for round air ducts - - galvanized steel no no no - - - - - 0.34 - 340 - 60 2880 - - - Supply and exhaust 3.16 79 - C IPX4 1 46 - - - - - - - - - - - -25...+50 - - - - - - - - - - 94 - - 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - -
CIVIC EC DBE 300 S21 V.2 230 - ceiling mounting - - - - - polymer-coated steel yes - - electric preheating - - - - - - 300 - 50/60 - - - - Supply and exhaust 79 - - A+ - 1 34 - - counter-flow polystyrene - -25...+40 - - 200 - - - - - - 83…92* - 44 - 204 - - 83 - - - - - - - - - - - 1.5 - - 7.7 - 1050 - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - -
KOMFORT LE 500-3 230 - ceiling mounting, wall mounting, floor mounting - - - - - aluzinc - - - - - - - - - - 500 - 50/60 1100 - 88 - - - - - E - 1 24-47 - - cross-flow polystyrene 3000 - 13 14.32 150 - - -25...+40 - - 25 mm mineral wool - 3300 - - - - - 139 - 49 2016 G4 G4 - - - - 300 - 1.32 - - - - - - - - - - - - - - - - - - - - -
Box-F 80x50 6D 400 - Inline centrifugal - for rectangular air ducts 800 500 galvanized steel no no no - - - - - 5.18 - 7610 - 50 830 - - - Exhaust, Supply - 2790 -20...+50 - IPX4 3 59 - - - - - - - - - - - - - - - - - - - - - - 2114 - 70.0 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - -
BlauPlast RR 200/2.5 - - - - 200 - - - - - - - - round 2500 PVC (plastic) air duct - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axis-Q 500 4D
50 Hz
400 - wall mounting axial 500 for round air ducts - - polymer-coated steel no no no - - - - - - - 6570 - 50 1300 - - - Exhaust, Supply - 450 - - IPX4 3 60 - - - - - - - - - - - -30...+60 - - - - - - - - - - 1825 - 14.0 - - - - - IP54 - - - - - - - 0.9 - - - - - - - - - - - - - - - - -
Axis-Q 500 4D
60 Hz
400 - wall mounting axial 500 for round air ducts - - polymer-coated steel no no no - - - - - - - 6230 - 60 1605 - - - Exhaust, Supply - 370 - - IPX4 3 60 - - - - - - - - - - - -30...+50 - - - - - - - - - - 1731 - 14.0 - - - - - IP54 - - - - - - - 0.7 - - - - - - - - - - - - - - - - -
Bravo Chrome 100 (127-220V/60Hz) 127 Chrome ceiling mounting, wall mounting axial 100 - - - - - - - - - - - - 0.115 10 91 33* 60 2500 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 25 0.4 - - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - -
Bravo Chrome 100 (127-220V/60Hz) 220 Chrome ceiling mounting, wall mounting axial 100 - - - - - - - - - - - - 0.054 9 91 33* 60 2500 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 25 0.36 - - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - -
Iso Box-F 150 G4-H13-Carbon V2 min 230 - ceiling mounting, wall mounting centrifugal 150 for round air ducts - - polymer-coated steel no no yes - - - - - 0.38 - 280 - 50 700 min - - Supply 17.08 85 - E IPX4 1 16 - - - - - - - - - - - -25…+40 - - - - - - - - - - 78 - - - - - - - - 98 - - - - - - - - - - - - - - - - - - - - - - - -
Iso Box-F 150 G4-H13-Carbon V2 max 230 - ceiling mounting, wall mounting centrifugal 150 for round air ducts - - polymer-coated steel no no yes - - - - - 0.54 - 355 - 50 1200 max - - Supply 17.08 114 - E IPX4 1 27 - - - - - - - - - - - -25…+40 - - - - - - - - - - 99 - - - - - - - - 96 - - - - - - - - - - - - - - - - - - - - - - - -
Tower-V 450 4D 400 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - - - - - 1.50 - 5920 - 50 1440 - - - Exhaust 41 755 -30…+50 - IPX4 3 57 - - - - - - - - - - - - - - - - - - - - - - 1644 - - 2018 - - - - IP54 - - - - - - - - - - - - - - - - - - - - - - - - -
Сentro-M 160 (60 Hz) 220-240 - Inline centrifugal 160 for round air ducts - - polymer-coated steel no no no - - - - - 0.61 - 575 - 60 3160 - - - Exhaust, Supply - 137 - IPX4 1 47 - - - - - - - - - - - -25...+45 - - - - - - - - - - 160 - 5.0 - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - -
Сentro-M 160 (50 Hz) 220-240 - Inline centrifugal 160 for round air ducts - - polymer-coated steel no no no - - - - - 0.44 - 567 - 50 2770 - - - Exhaust, Supply - 99 - C IPX4 1 45 - - - - - - - - - - - -25…+45 - - - - - - - - - - 158 - 5.0 2018 - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - -