Selected 1263 products
Mode FrequencySEC classIngress protection ratingWeightSFPMaximum air flowCurrentRPMSound pressure levelPowerVoltageTypeMaximum air flowDesignMounting****LED-light powerSpeedVoltagePhasePowerSound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004Outdoor sound pressure attenuation in accordance with DIN EN 20140Heat recovery efficiency in accordance with DIBt LÜ-A 20Transported air temperatureAir ductRemote control panelFunctionsFilterAir flow in heat recovery modeAir flow in heat recovery modeCurrentSound pressure level at 3 mHeat recovery efficiencyHeat exchanger typeMax. power without electric heaterMax. unit powerMax. unit current without electric heaterMax. unit currentTransported air temperatureInsulationExtract filterSupply filterEC motorHeat exchanger materialConnected air duct diameterCasing materialIntegrated electric preheater powerElectric heater current
Ceileo Compact 250 Light T
(50 Hz, min)
50 C*** IPX2 6.4 0.49 47 0.12 756 25* 23 220-240 Exhaust 170 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors 2 х 10 min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 Light T
(50 Hz, max)
50 C*** IPX2 6.4 0.54 72 0.18 1122 29* 39 220-240 Exhaust 260 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors 2 х 10 max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 Light T
(60 Hz, min)
60 C*** IPX2 6.4 0.56 44 0.14 732 25* 25 220-240 Exhaust 160 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors 2 х 10 min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 Light T
(60 Hz, max)
60 C*** IPX2 6.4 0.67 75 0.22 1140 30* 50 220-240 Exhaust 270 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors 2 х 10 max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 T
(50 Hz, min)
50 C*** IPX2 5.3 0.49 47 0.12 756 25* 23 220-240 Exhaust 170 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors - min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 T
(50 Hz, max)
50 C*** IPX2 5.3 0.54 72 0.18 1122 29* 39 220-240 Exhaust 260 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors - max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 T
(60 Hz, min)
60 C*** IPX2 5.3 0.56 44 0.14 732 25* 25 220-240 Exhaust 160 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors - min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 T
(60 Hz, max)
60 C*** IPX2 5.3 0.67 75 0.22 1140 30* 50 220-240 Exhaust 270 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors - max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 Light
(50 Hz, min)
50 - IPX2 6.4 0.49 47 0.12 756 25* 23 220-240 Exhaust 170 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - 2 х 10 min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 Light
(50 Hz, max)
50 - IPX2 6.4 0.54 72 0.18 1122 29* 39 220-240 Exhaust 260 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - 2 х 10 max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 Light
(60 Hz, min)
60 - IPX2 6.4 0.56 44 0.14 732 25* 25 220-240 Exhaust 160 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - 2 х 10 min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 Light
(60 Hz, max)
60 - IPX2 6.4 0.67 75 0.22 1140 30* 50 220-240 Exhaust 270 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - 2 х 10 max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250
(50 Hz, min)
50 - IPX2 5.3 0.49 47 0.12 756 25* 23 220-240 Exhaust 170 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - - min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250
(50 Hz, max)
50 - IPX2 5.3 0.54 72 0.18 1122 29* 39 220-240 Exhaust 260 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - - max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250
(60 Hz, min)
60 - IPX2 5.3 0.56 44 0.14 732 25* 25 220-240 Exhaust 160 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - - min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250
(60 Hz, max)
60 - IPX2 5.3 0.67 75 0.22 1140 30* 50 220-240 Exhaust 270 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - - max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 Light T
(50 Hz, min)
50 C*** IPX2 6.4 0.55 36 0.1 714 24* 20 220-240 Exhaust 130 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors 2 х 10 min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 Light T
(50 Hz, max)
50 C*** IPX2 6.4 0.50 58 0.13 1026 27* 29 220-240 Exhaust 210 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors 2 х 10 max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 Light T
(60 Hz, min)
60 C*** IPX2 6.4 0.58 36 0.11 588 24* 21 220-240 Exhaust 130 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors 2 х 10 min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 Light T
(60 Hz, max)
60 C*** IPX2 6.4 0.54 63 0.15 936 28* 34 220-240 Exhaust 225 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors 2 х 10 max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 T
(50 Hz, min)
50 C*** IPX2 5.3 0.55 36 0.1 714 24* 20 220-240 Exhaust 130 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors - min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 T
(50 Hz, max)
50 C*** IPX2 5.3 0.50 58 0.13 1026 27* 29 220-240 Exhaust 210 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors - max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 T
(60 Hz, min)
60 C*** IPX2 5.3 0.58 36 0.11 588 24* 21 220-240 Exhaust 130 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors - min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 T
(60 Hz, max)
60 C*** IPX2 5.3 0.54 63 0.15 936 28* 34 220-240 Exhaust 225 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors - max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 Light
(50 Hz, min)
50 - IPX2 6.4 0.55 36 0.1 714 24* 20 220-240 Exhaust 130 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - 2 х 10 min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 Light
(50 Hz, max)
50 - IPX2 6.4 0.50 58 0.13 1026 27* 29 220-240 Exhaust 210 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - 2 х 10 max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 Light
(60 Hz, min)
60 - IPX2 6.4 0.58 36 0.11 588 24* 21 220-240 Exhaust 130 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - 2 х 10 min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200 Light
(60 Hz, max)
60 - IPX2 6.4 0.54 63 0.15 936 28* 34 220-240 Exhaust 225 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - 2 х 10 max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200
(50 Hz, min)
50 - IPX2 5.3 0.55 36 0.1 714 24* 20 220-240 Exhaust 130 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - - min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200
(50 Hz, max)
50 - IPX2 5.3 0.50 58 0.13 1026 27* 29 220-240 Exhaust 210 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - - max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200
(60 Hz, min)
60 - IPX2 5.3 0.58 36 0.11 588 24* 21 220-240 Exhaust 130 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - - min - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 200
(60 Hz, max)
60 - IPX2 5.3 0.54 63 0.15 936 28* 34 220-240 Exhaust 225 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan - - max - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact DC 110 50/60 C*** IPX2 5.3 0.37 52 0.18 1100 23-25* 19 120-240 Exhaust 187 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact DC 110 Light 50/60 C*** IPX2 6.4 0.37 52 0.18 1100 23-25* 19 120-240 Exhaust 187 centrifugal ceiling mounting Sound pressure level measured in free space at a distance of 3 meters from the fan For fans with humidity or motion sensors 2 х 10 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Vento Ergo A50 S Pro1
(1 speed)
50/60 - IP24 - 1.54 6 0.024 610 - - - - 21 - - - - - I 100-230 1 4.5 22 13 40 up to 88 -20...+40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) 11 3 - - - - - - - - - - - - - - - - - -
Vento Ergo A50 S Pro1
(2 speed)
50/60 - IP24 - 1.12 9 0.026 800 - - - - 32 - - - - - II 100-230 1 5 29 20 40 up to 88 -20...+40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) 16 4 - - - - - - - - - - - - - - - - - -
Vento Ergo A50 S Pro1
(3 speed)
50/60 - IP24 - 1.01 14 0.039 1450 - - - - 50 - - - - - III 100-230 1 7 32 23 40 up to 88 -20...+40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) 25 7 - - - - - - - - - - - - - - - - - -
Vento Ergo A50 S10 Pro1
(1 speed)
50/60 - IP24 - 1.54 6 0.024 610 - - - - 21 - - - - - I 100-230 1 4.5 22 13 40 up to 88 -20...+40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) - - - - - - - - - - - - - - - - - - - -
Vento Ergo A50 S10 Pro1
(2 speed)
50/60 - IP24 - 1.12 9 0.026 800 - - - - 32 - - - - - II 100-230 1 5 29 20 40 up to 88 -20 … +40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) - - - - - - - - - - - - - - - - - - - -
Vento Ergo A50 S10 Pro1
(3 speed)
50/60 - IP24 - 1.01 14 0.039 1450 - - - - 50 - - - - - III 100-230 1 7 32 23 40 up to 88 -20 … +40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) - - - - - - - - - - - - - - - - - - - -
Vento Ergo A50-1 S Pro1
(1 speed)
50/60 - IP24 - 1.54 6 0.024 610 - - - - 21 - - - - - I 100-230 1 4.5 22 13 40 up to 88 -20...+40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) 11 3 - - - - - - - - - - - - - - - - - -
Vento Ergo A50-1 S Pro1
(2 speed)
50/60 - IP24 - 1.12 9 0.026 800 - - - - 32 - - - - - II 100-230 1 5 29 20 40 up to 88 -20 … +40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) 16 4 - - - - - - - - - - - - - - - - - -
Vento Ergo A50-1 S Pro1
(3 speed)
50/60 - IP24 - 1.01 14 0.039 1450 - - - - 50 - - - - - III 100-230 1 7 32 23 40 up to 88 -20 … +40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) 25 7 - - - - - - - - - - - - - - - - - -
Vento Ergo A50-1 S10 Pro1
(1 speed)
50/60 - IP24 - 1.54 6 0.024 610 - - - - 21 - - - - - I 100-230 1 4.5 22 13 40 up to 88 -20...+40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) 11 3 - - - - - - - - - - - - - - - - - -
Vento Ergo A50-1 S10 Pro1
(2 speed)
50/60 - IP24 - 1.12 9 0.026 800 - - - - 32 - - - - - II 100-230 1 5 29 20 40 up to 88 -20 … +40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) 16 4 - - - - - - - - - - - - - - - - - -
Vento Ergo A50-1 S10 Pro1
(3 speed)
50/60 - IP24 - 1.01 14 0.039 1450 - - - - 50 - - - - - III 100-230 1 7 32 23 40 up to 88 -20 … +40 150 - Filter replacement indication, Timer, Humidity sensor G3 (Option: F8 PM2,5 > 99 %*) 25 7 - - - - - - - - - - - - - - - - - -
Solo A35 L S4 Pro R
(1 speed)
- - IP24 - 0.27 8 - - - - - - 30 - - - - - I 220-240 - 1.20 - - - - -15...+40 - - - - - - 0.019 27 ≤85 сeramic - - - - - - - - - - - - - -
Solo A35 L S4 Pro R
(2 speed)
- - IP24 - 0.27 13 - - - - - - 46 - - - - - II 220-240 - 1.70 - - - - -15...+40 - - - - - - 0.025 32 ≤85 сeramic - - - - - - - - - - - - - -
Solo A35 S4 Pro R
(1 speed)
- - IP24 - 0.29 8 - - - - - - 30 - - - - - I 220-240 - 1.20 - - - - -15...+40 - - - - - - 0.019 27 ≤85 сeramic - - - - - - - - - - - - - -
Solo A35 S4 Pro R
(2 speed)
- - IP24 - 0.27 13 - - - - - - 46 - - - - - II 220-240 - 1.70 - - - - -15...+40 - - - - - - 0.025 32 ≤85 сeramic - - - - - - - - - - - - - -
Reneo SE 270-E R S21 50/60 A - 22 - - - - - - 230 - 304 - ceiling mounting, floor mounting - - - - - 1 - - - - - - - - - - - - - - 84 counter-flow 176 1576 1.34 7.55 -25...+40 25 mm G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) yes enthalpy 125 expanded polypropylene 1400 6.21
Reneo S 270-E R S21 50/60 A - 22 - - - - - - 230 - 304 - ceiling mounting, floor mounting - - - - - 1 - - - - - - - - - - - - - 37 84 counter-flow 176 176 1.34 1.34 -25...+40 25 mm G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) yes enthalpy 125 expanded polypropylene - -
Reneo SE 270 L S21 50/60 A - 22 - - - - - - 230 - 304 - ceiling mounting, floor mounting - - - - - 1 - - - - - - - - - - - - - 37 91 counter-flow 176 1576 1.34 7.55 -25...+40 25 mm G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) yes polystyrene 125 expanded polypropylene 1400 6.21
Reneo SE 270 R S21 50/60 A - 22 - - - - - - 230 - 304 - ceiling mounting, floor mounting - - - - - 1 - - - - - - - - - - - - - 37 91 counter-flow 176 1576 1.34 7.55 -25...+40 25 mm G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) yes polystyrene 125 expanded polypropylene 1400 6.21
Reneo SE 270-E L S21 50/60 A - 22 - - - - - - 230 - 304 - ceiling mounting, floor mounting - - - - - 1 - - - - - - - - - - - - - - 84 counter-flow 176 1576 1.34 7.55 -25...+40 25 mm G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) yes enthalpy 125 expanded polypropylene 1400 6.21
Reneo S 210 R S14 50/60 A+ - 20 - - - - - - 230 - 255 - ceiling mounting, floor mounting - - - - - 1 - - - - - - - - - - - - - 34 92 counter-flow 114 114 0.92 0.92 -25...+40 25 mm G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) yes polystyrene 125 expanded polypropylene - -
Reneo S 210-E R S14 50/60 A - 20 - - - - - - 230 - 255 - ceiling mounting, floor mounting - - - - - 1 - - - - - - - - - - - - - 34 83 counter-flow 114 114 0.92 0.92 -25...+40 25 mm G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) yes enthalpy 125 expanded polypropylene - -
Reneo S 210-E L S14 50/60 A - 20 - - - - - - 230 - 255 - ceiling mounting, floor mounting - - - - - 1 - - - - - - - - - - - - - 34 83 counter-flow 114 114 0.92 0.92 -25...+40 25 mm G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) yes enthalpy 125 expanded polypropylene - -
Reneo S 270-E L S21 50/60 A - 22 - - - - - - 230 - 304 - ceiling mounting, floor mounting - - - - - 1 - - - - - - - - - - - - - 37 84 counter-flow 176 176 1.34 1.34 -25...+40 25 mm G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) yes enthalpy 125 expanded polypropylene - -