Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Print version
Search results
Selected 1018 products
Mode VoltageStyleMountingDesignConnection diameterAir ductWidthHeightCasing materialEC motorOutdoor mountingSound-insulated casingHeatingCurrentPowerMaximum air flowSound pressure levelFrequencyRPMSpeedHeat recovery efficiencyMaximum air capacityTypeWeight PowerMax. operating temperatureSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialElectric heater powerSound pressure level at 1 mSound pressure level at 3 mOutdoor sound pressure attenuationRegeneration efficiencyInsulation classFan currentTransported air temperature CurrentConnected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeConnected air duct size Transported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140Number of water coil rowsHumidity recovery efficiencyInsulationHeat recovery efficiencyTotal unit powerSound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionMaximum air flowSFPWeightErPMaximum air flowExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeMotor IP ratingMax. power without electric heaterMax. unit current without electric heaterMax. unit power with electric heaterMax. unit current with electric heaterCurrentPreheater power consumptionSound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Electric heater current Maximum heat medium temperatureRemote control panelFunctionsIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Power*Transported air temperatureSpigot
Tower-V 220 2Е (60 Hz) 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - 0.54 - 883 - 60 2840 - - - Exhaust 7 118 -25…+50 IPX4 1 51 - - - - - - - - - - - - - - - - - - - - - - - - - - 245 - - - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Tower-V 220 2Е (50 Hz) 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - 0.49 - 880 - 50 2580 - - - Exhaust 7 108 -25…+50 C IPX4 1 50 - - - - - - - - - - - - - - - - - - - - - - - - - - 244 - - 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Сentro-M 125 L (60 Hz) 220-240 - Inline centrifugal 125 for round air ducts - - polymer-coated steel no no no - 0.24 - 370 - 60 3240 - - - Exhaust, Supply - 54 - IPX4 1 38 - - - - - - - - - - - - - - - -25...+45 - - - - - - - - - - 103 - 2.9 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Сentro-M 125 L (50 Hz) 220-240 - Inline centrifugal 125 for round air ducts - - polymer-coated steel no no no - 0.25 - 326 - 50 2760 - - - Exhaust, Supply - 47 - C IPX4 1 37 - - - - - - - - - - - - - - - -25…+45 - - - - - - - - - - 91 - 2.9 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Iso-VK 315 4E 230 - Inline centrifugal 315 for round air ducts - - aluzinc no no yes - 2.16 - 1910 - 50 1320 - - - Exhaust 37,2 250 –25…+120 IPX4 1 48 - - - - - - - - - - - - - - - - - - - - - - - - - - 531 - - - - - - - - IP55 - - - - - - - - - - - - - - - - - - -
VENTO V50-1 (1 speed) 220-240 - wall mounting - - 164x164 - - - - - - - 0.021 - 26 - 50 599 - - - - - 3.68 - A IP24 - - - - - 24 14 19 ≤ 90 - - - - - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - -
VENTO V50-1 (2 speed) 220-240 - wall mounting - - 164x164 - - - - - - - 0.026 - 53 - 50 1155 - - - - - 4.83 - A IP24 - - - - - 34 24 19 ≤ 90 - - - - - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - -
Box-I EC 40x20-1 230 - Inline centrifugal - for rectangular air ducts - - galvanized steel yes no yes - 0.69 - - - 50/60 2470 - - 810 Exhaust, Supply 15.1 91 -25...+50 B IPX4 1 33 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2018 225 - - - - IP55 - - - - - - - - - - - - - - - - - - -
Tower-HC EC 250 A 230 - for roof centrifugal - for round air ducts, for square air ducts - - aluminium yes yes no - 1.25 - 1500 - 50/60 3310 - - - Exhaust - 164 -25...+60 IPX4 1 54 - - - - - - - - - - - - - - - - - - - - - - - - - - 417 - 9 2018 - - - - - IP55 - - - - - - - - - - - - - - - - - - -
KOMFORT EC DW 2000-2 R 230 - ceiling mounting - - - - - aluzinc yes - - - - - 1950 - 50/60 2920 - - - - - 840 - NRVU - 1 58 cross-flow aluminum - - - - - - - - - 315 - - - -25…+40 - 2 - 25 mm mineral wool 75 - - - - - 542 - 194 2016 - G4 G4 - - - - - - - 5.00 - - - - - - - - - - - - - -
Axis-F 200 2Е
50 Hz
230 - Inline axial 200 for round air ducts - - polymer-coated steel no no no - - - 860 - 50 2300 - - - Exhaust, Supply - 55 - - IPX4 1 48 - - - - - - - - - - - - - - - -30...+60 - - - - - - - - - - 239 - 3.0 - - - - - - IP24 - - - - 0.26 - - - - - - - - - - - - - -
Axis-F 200 2Е
60 Hz
230 - Inline axial 200 for round air ducts - - polymer-coated steel no no no - - - 875 - 60 2550 - - - Exhaust, Supply - 61 - - IPX4 1 49 - - - - - - - - - - - - - - - -30...+50 - - - - - - - - - - 243 - 3.0 - - - - - - IP24 - - - - 0.28 - - - - - - - - - - - - - -
Aero Still Chrome 100 220-240 Chrome ceiling mounting, wall mounting axial 100 - - - - - - - - 0.035 5.5 84 25* 50 - - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 23 0.24 - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
KOMFORT Ultra EC S2 300-E S2 white 230 - ceiling mounting, wall mounting, floor mounting - 125 for round air ducts - - - yes no yes - - - 300 - 50/60 - - - - Supply and exhaust - 165 - C - 1 33 cross-flow enthalpy - - - - - - - - 1.3 - - - - -25...+40 - - 26...45 20 mm mineral wool 51...73 - - - - - 83 - 28 2016, 2018 - G4 F8, G4 - - - - - - - - - - - - - - - - - - - - - -
Tower-H 355 4D 400 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - 0.58 - 3290 - 50 1430 - - - Exhaust 30.3 264 -30…+60 - IPX4 3 52 - - - - - - - - - - - - - - - - - - - - - - - - - - 914 - - 2018 - - - - - IP54 - - - - - - - - - - - - - - - - - - -
Tower-H 355 4D (60 Hz) 400 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - 0.64 - 3540 - 60 1650 - - - Exhaust 30.3 330 -30…+60 - IPX4 3 53 - - - - - - - - - - - - - - - - - - - - - - - - - - 983 - - - - - - - IP54 - - - - - - - - - - - - - - - - - - -
Auto 100 220-240 White wall mounting axial 100 - - - - - - - - 0.085 18 98 34* 50 2300 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 27 0.66 - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Primo EC 150 230 - Inline mixed-flow 150 for round air ducts - - - yes no no - - 54 700 - 50/60 3700 - - - Supply and exhaust - - - - IPX4 1 39 - - - - - - - - - - - - - - - -25...+55 - - - - - - - - - - 194 - - 2018 - - - - - IP44 - - - - 0.48 - - - - - - - - - - - - - -
S-Vent 315x143-2.2-6D 400 - floor mounting centrifugal - for rectangular air ducts, for round air ducts - - polymer-coated steel no yes no - 5.6 - 4375 - 50 940 - - - Exhaust, Supply 46.8 2200 +60 - IP54 3 70 - - - - - - - - - - - - - - - - - - - - - - - - - - 1215 - - - - - - - - IP54 - - - - - - - - - - - - - - - - - - -
Extero 160
50 Hz
230 - Inline centrifugal 160 for round air ducts - - polymer-coated steel no yes no - 0.41 - 650 - 50 2440 - - - Exhaust - 95 +55 B IPX4 1 60 - - - - - - - - - - - - - - - - - - - - - - - - - - 181 - 4.5 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Extero 160
60 Hz
230 - Inline centrifugal 160 for round air ducts - - polymer-coated steel no yes no - 0.42 - 685 - 60 2400 - - - Exhaust - 96 +55 B IPX4 1 60 - - - - - - - - - - - - - - - - - - - - - - - - - - 190 - 4.5 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
CIVIC EC LBE 1200 S21 V.2 230 - floor mounting - - - - - polymer-coated steel yes - - electric preheating - - 1240 - 50/60 - - - - Supply and exhaust 358 - - A - 3 30 counter-flow polystyrene - - - - - - - -25...+40 - 400 - - - - - - - 40 mm mineral wool 84…96* - 40 - 345 - 344 - - - - - - - - - - 2.3 - 12 - 3150 - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - -
KOMFORT Ultra S 250-E S1 230 - ceiling mounting, wall mounting, floor mounting - - for round air ducts - - aluzinc no no yes - - - 250 - 50/60 - - - - Supply and exhaust - 148 - E - 1 28...47 cross-flow enthalpy - - - - - - - - 0.78 125 - - - -25...+40 - - 27...45 20 mm mineral wool 52...73 - - - - - 69 - - 2018 - G4 G4 (option: F8 PM2.5 > 81 %) - - - - - - - - - - - - - - - - - - - - - -
Box-F 90x50 8D 400 - Inline centrifugal - for rectangular air ducts 900 500 galvanized steel no no no - 4.1 - 7175 - 50 680 - - - Exhaust, Supply - 2000 -20...+40 - IPX4 3 59 - - - - - - - - - - - - - - - - - - - - - - - - - - 1993 - 90.0 - - - - - - IP44 - - - - - - - - - - - - - - - - - - -
BLAUBOX MW 750-4 Pro 230 - ceiling mounting, wall mounting, floor mounting centrifugal - for rectangular air ducts - - aluzinc no no yes - - - 750 - 50 1650 - - - Supply - - - D - 1 35 - - - - - - - - - -25...+40 1.08 - - - 400х200 - - 4 - 25 mm mineral wool - 245 - - - - 208 - 41.3 2016, 2018 - - G4 - - - - - - - - - - - - - - - - - - - - - -
Axis-Q 300 4Е
50 Hz
230 - wall mounting axial 300 for round air ducts - - polymer-coated steel no no no - - - 1340 - 50 1350 - - - Exhaust, Supply - 75 - - IPX4 1 44 - - - - - - - - - - - - - - - -30...+60 - - - - - - - - - - 372 - 5.0 - - - - - - IP44 - - - - 0.35 - - - - - - - - - - - - - -
Axis-Q 300 4Е
60 Hz
230 - wall mounting axial 300 for round air ducts - - polymer-coated steel no no no - - - 1475 - 60 1405 - - - Exhaust, Supply - 92 - - IPX4 1 45 - - - - - - - - - - - - - - - -30...+50 - - - - - - - - - - 410 - 5.0 - - - - - - IP44 - - - - 0.4 - - - - - - - - - - - - - -
Bravo Chrome 100 220-240 Chrome ceiling mounting, wall mounting axial 100 - - - - - - - - 0.085 14 101 35* 50 2300 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 28 0.5 - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
KOMFORT EC SB350 S11 220-240 - wall mounting, floor mounting - - - - - polymer-coated steel yes - - - - - 415 - 50/60 3200 - - - - - 170 - A - - 28 counter-flow polystyrene - - - - - - - - - 160 - - - -25...+40 - - - 40 mm mineral wool 80...89 - - - - - 115 - 66 2016, 2018 - G4 F7 (option: G4) - - - - - - - 1.3 - - - - - - - - - - - - - -
Tower-V 560 4D 400 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - 3.36 - 13560 - 50 1400 - - - Exhaust 63 1970 -25…+50 - IPX4 3 66 - - - - - - - - - - - - - - - - - - - - - - - - - - 3767 - - 2018 - - - - - IP54 - - - - - - - - - - - - - - - - - - -
Centro 200 V2
min
230 - Inline centrifugal 200 for round air ducts - - plastic no no no - 0.27 - 430 - - 1920 - - - Exhaust, Supply - 83 -25...+55 C IPX4 1 42 - - - - - - - - - - - - - - - - - - - - - - - - - - 119 - 3.00 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Centro 200 V2
max
230 - Inline centrifugal 200 for round air ducts - - plastic no no no - 0.43 - 741 - - 2470 - - - Exhaust, Supply - 95 -25...+55 C IPX4 1 42 - - - - - - - - - - - - - - - - - - - - - - - - - - 206 - 3.00 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
inWave 100/125 (100 spigot)
Min
230 - Inline mixed-flow - for round air ducts - - plastic no no yes - - - 114 - 50 1568 min - - Exhaust, Supply 5.0 28 –25…+55 - IPX4 1 19 - - - - - - - - - - - - - - - - - - - - - - - - - - 32 - - 2018 - - - - - IP20 - - - - 0.13 - - - - - - - - - - - - - 100
inWave 100/125 (100 spigot)
Mid
230 - Inline mixed-flow - for round air ducts - - plastic no no yes - - - 147 - 50 1952 mid - - Exhaust, Supply 5.0 31 –25…+55 - IPX4 1 23 - - - - - - - - - - - - - - - - - - - - - - - - - - 41 - - 2018 - - - - - IP20 - - - - 0.14 - - - - - - - - - - - - - 100
inWave 100/125 (100 spigot)
Max
230 - Inline mixed-flow - for round air ducts - - plastic no no yes - - - 220 - 50 2362 max - - Exhaust, Supply 5.0 32 –25…+55 - IPX4 1 27 - - - - - - - - - - - - - - - - - - - - - - - - - - 61 - - 2018 - - - - - IP20 - - - - 0.15 - - - - - - - - - - - - - 100
ALB-45 220-240 - ceiling mounting, wall mounting axial - for round air ducts - - polymer-coated steel no no no - - - 3850 - 50 1360 - - - Supply - 255 - - IP44 - 58 - - - - - - - F 1.12 - - - - - - - - - - - - - - - - - 1070 - 50 - - - - - - IP44 - - - - - - - - - - - +100 - - - - - - -
Box-I EC 60x35-1 230 - Inline centrifugal - for rectangular air ducts - - galvanized steel yes no yes - 2.62 - - - 50/60 2000 - - 2815 Exhaust, Supply 56.6 361 -25...+50 IPX4 1 38 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2018 782 - - - - IP54 - - - - - - - - - - - - - - - - - - -
Tower-HC EC 190 230 - for roof centrifugal - for round air ducts, for square air ducts - - polymer-coated steel yes yes no - 0.87 - 770 - 50/60 3538 - - - Exhaust - 110 -25...+60 IPX4 1 52 - - - - - - - - - - - - - - - - - - - - - - - - - - 214 - 6 2018 - - - - - IP55 - - - - - - - - - - - - - - - - - - -
KOMFORT EC DB 250 S14 230 - ceiling mounting, wall mounting - - for round air ducts - - galvanized steel yes no yes - - - 270 - 50/60 - - 80...98 - Supply and exhaust - - - A - 1 28 counter-flow polystyrene - - - - - - - - 0.8 125 - - - -25...+40 - - - 40 mm mineral wool - 101 - - - - 75 - 48 2018 - G4 F7 - - - - - - - - - - - - - - - - - - - - - -
Tubo-MZ 200 [50 Hz] 220-240 - Inline axial 200 for round air ducts - - galvanized steel - no no - 0.28 - 405 - 50 1300 - - - Supply and exhaust 2.54 43 -30 … +40 IPX4 1 33 - - - - - - - - - - - - - - - - - - - - - - - - - - 113 - - - - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Tubo-MZ 200 [60 Hz] 220-240 - Inline axial 200 for round air ducts - - galvanized steel - no no - 0.21 - 470 - 60 1615 - - - Supply and exhaust 2.54 33 -30 … +40 IPX4 1 33 - - - - - - - - - - - - - - - - - - - - - - - - - - 131 - - - - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Sileo V2 100 min - White ceiling mounting, wall mounting axial 100 - - - - - - - - 0.029 4.5 60 22* 50 1850 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 220-240 - - 17 0.27 - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Sileo V2 100 max - White ceiling mounting, wall mounting axial 100 - - - - - - - - 0.052 7 90 25* 50 2400 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 220-240 - - 25 0.28 - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Iso-RB 450 L 230 - Inline centrifugal 450 for round air ducts - - aluzinc no no yes - 2.13 - 3750 - 50 1350 - - - Exhaust, Supply - 482 - - IPX4 1 50 - - - - - - - - - - - - - - - -25...+55 - - - - - - - - - - 1042 - 84 2018 - - - - - IP54 - - - - - - - - - - - - - - - - - - -
Tower-H 225 2Е (50 Hz) 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - 0.54 - 915 - 50 2790 - - - Exhaust 9.2 123 -25…+50 - IPX4 1 51 - - - - - - - - - - - - - - - - - - - - - - - - - - 254 - - 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Tower-H 225 2Е (60 Hz) 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - 0.70 - 1010 - 60 2820 - - - Exhaust 9.2 169 -25…+50 - IPX4 1 52 - - - - - - - - - - - - - - - - - - - - - - - - - - 281 - - - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Jet 100 220-240 - ceiling mounting, wall mounting axial 100 - - - - - - - - 0.085 14 95 34* 50 2300 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 26 0.53 - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Trio 150 - White ceiling mounting, wall mounting axial 150 - - - - - - - - 0.21 - 255 35* 50 - - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 220-240 - - 71 0.39 0.97 - - - - - - - - - - - - - - - - - - - - - - 28 Sound pressure level measured in free space at a distance of 3 meters from the fan - -
S-Vent 250х127-2.2-4D 400 - floor mounting centrifugal - for rectangular air ducts, for round air ducts - - polymer-coated steel no yes no - 5.1 - 3720 - 50 1420 - - - Exhaust, Supply 32.2 2200 +60 - IP54 3 78 - - - - - - - - - - - - - - - - - - - - - - - - - - 1033 - - - - - - - - IP54 - - - - - - - - - - - - - - - - - - -
Box-D 125 (50 Hz) 230 - Inline centrifugal 125 for round air ducts - - galvanized steel no no no - 0.26 - - - 50 2500 - - 310 Exhaust 3.2 61 25 +50 C IPX4 1 48 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Box-D 125 (60 Hz) 230 - Inline centrifugal 125 for round air ducts - - galvanized steel no no no - 0.36 - - - 60 2740 - - 320 Exhaust 3.2 81 25 +50 C IPX4 1 49 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Blaubox EC ME 4000-45 S31 400 - ceiling mounting, wall mounting, floor mounting centrifugal - for rectangular air ducts - - aluzinc yes no - - - - 5000 - 50 - - - - Supply - - - - - 3 49 - - 45000 - - - - - - -30…+40 - 700 x 400 - - - - - - - 30 mm mineral wool - - - - - - - - 60 2018 - - - - - - 717 1.1 45717 73.2 - - - - Coarce 90% / G4 (option: ePM1 70% / F7) - - - - - - - - - -
KOMFORT EC LBE 400-E S21 230 - ceiling mounting, floor mounting - - - - - galvanized steel - - - - - - 540 - 50/60 - - - - - - - - A - 1 27 counter-flow enthalpy 2800 - - - - - - - - 200 - - - -25…+40 - - - 40 mm mineral wool 78–89 - - - - - 150 - 76 - - G4 G4, F7 - - - 289 2.1 3089 14.3 - - - - - - 12.2 - - - - - - - -
Iso-ZS 315/2x250 4E 230 - - centrifugal - for round air ducts - - galvanized steel no no yes - 3.36 - - - 50 1390 - - 3420 Exhaust, Supply 33.0 764 -20…+50 - IPX4 1 45 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
CIVIC EC LBE 300 S21 230 - floor mounting - - - - - polymer-coated steel yes - - electric preheating - - 320 - 50/60 2150 - - - Supply and exhaust 139±3% - - A - 1 21 counter-flow polystyrene - - - - - - - -25...+40 - 200 - - - - - - - 40 mm mineral wool 78...92* - 31 - 125 - 89 - - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - 0.9 - 7 - 1400 - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - -
Axis-QR 300 2D
50 Hz
400 - wall mounting axial 300 for round air ducts - - polymer-coated steel no no no - - - 2310 - 50 2350 - - - Exhaust, Supply - 145 - - IPX4 3 52 - - - - - - - - - - - - - - - -30...+60 - - - - - - - - - - 642 - 5.1 - - - - - - IP44 - - - - 0.25 - - - - - - - - - - - - - -
Axis-QR 300 2D
60 Hz
400 - wall mounting axial 300 for round air ducts - - polymer-coated steel no no no - - - 2390 - 60 2570 - - - Exhaust, Supply - 165 - - IPX4 3 52 - - - - - - - - - - - - - - - -30...+50 - - - - - - - - - - 664 - 5.1 - - - - - - IP44 - - - - 0.29 - - - - - - - - - - - - - -
Quatro Hi-Tech Chrome 125 220-240 Hi-Tech Chrome ceiling mounting, wall mounting axial 125 - - - - - - - - 0.1 16 167 34* 50 2400 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 46 0.34 - - - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Vento Expert A50-1 S Pro
(1 speed)
100-240 - - - - 160 - - - yes - - - 0.025 - - - 50/60 800 - - - - - 3.61 - - IP24 - - - - - - - - - - - - - - 15 8 - -20…+40 42 - - - - - - - - - - 1.73 - - - - - 4 2 - - - - - - - 20 11 G3 (Option: F7 PM2,5 > 99 %*) up to 93 - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - Maximum air flow 40 m³/h - -
Vento Expert A50-1 S Pro
(2 speed)
100-240 - - - - 160 - - - yes - - - 0.03 - - - 50/60 1300 - - - - - 4.15 - - IP24 - - - - - - - - - - - - - - 30 15 - -20…+40 42 - - - - - - - - - - 1.00 - - - - - 8 4 - - - - - - - 27 18 G3 (Option: F7 PM2,5 > 99 %*) up to 93 - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - Maximum air flow 40 m³/h - -
Vento Expert A50-1 S Pro
(3 speed)
100-240 - - - - 160 - - - yes - - - 0.039 - - - 50/60 1900 - - - - - 5.20 - - IP24 - - - - - - - - - - - - - - 50 25 - -20…+40 42 - - - - - - - - - - 0.75 - - - - - 14 7 - - - - - - - 30 21 G3 (Option: F7 PM2,5 > 99 %*) up to 93 - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - Maximum air flow 40 m³/h - -
Tower-A 300 4Е (60 Hz) 230 - for roof axial - for round air ducts - - polymer-coated steel no yes no - 0.4 - 1475 - 60 1405 - - - Exhaust 10.5 92 -30…+50 B IP24 1 59 - - - - - - - - - - - - - - - - - - - - - - - - - - 410 - - 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Tower-A 300 4Е (50 Hz) 230 - for roof axial - for round air ducts - - polymer-coated steel no yes no - 0.35 - 1340 - 50 1350 - - - Exhaust 10.5 75 -30…+60 B IP24 1 58 - - - - - - - - - - - - - - - - - - - - - - - - - - 372 - - 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Centro-MZ 250 L
50 Hz
220-240 - ceiling mounting, wall mounting centrifugal 250 for round air ducts - - galvanized steel no no no - 0.59 - 980 - 50 2785 - - - Exhaust, Supply 5.25 134 - B IPX4 1 51 - - - - - - - - - - - - - - - -25...+50 - - - - - - - - - - 272 - - 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Centro-MZ 250 L
60 Hz
220-240 - ceiling mounting, wall mounting centrifugal 250 for round air ducts - - galvanized steel no no no - 0.77 - 1030 - 60 2880 - - - Supply and exhaust 5.25 175 - B IPX4 1 51 - - - - - - - - - - - - - - - -25...+50 - - - - - - - - - - 286 - - 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
KOMFORT EC SB200-E S11 230 - wall mounting, floor mounting - - - - - polymer-coated steel yes - - - - - 260 - 50/60 2050 - - - - - 130 - A - 1 24 counter-flow enthalpy - - - - - - - - - 125 - - - -25...+60 - - - 25 mm mineral wool 74–94 - - - - - 72 - 45 2016, 2018 - - G3 - - - - - - - 1.0 - - - - - - - - - - - - - -
Tower-V 310 2E 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - 1.42 - 2150 - 50 2620 - - - Exhaust 13 324 -25…+50 - IPX4 1 58 - - - - - - - - - - - - - - - - - - - - - - - - - - 597 - - 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
Centro 315 230 - Inline centrifugal 315 for round air ducts - - plastic no no no - 0.88 - 1340 - 50 2655 - - - Exhaust, Supply - 200 -25...+55 - IPX4 1 48 - - - - - - - - - - - - - - - - - - - - - - - - - - 372 - 4.85 2018 - - - - - IP44 - - - - - - - - - - - - - - - - - - -
min 230 - Inline mixed-flow - for round air ducts - - galvanized steel no no yes - - - 1007 - 50 2292 min - - Exhaust, Supply 9.8 144 - - IPX4 1 38 - - - - - - - - - - - - - - - - - - - - - - - - - - 280 - - 2018 - - - - - IP20 - - - - 0.70 - - - - - - - - - - - - -25...+55 -
mid 230 - Inline mixed-flow - for round air ducts - - galvanized steel no no yes - - - 1404 - 50 2626 mid - - Exhaust, Supply 9.8 173 - - IPX4 1 43 - - - - - - - - - - - - - - - - - - - - - - - - - - 390 - - 2018 - - - - - IP20 - - - - 0.81 - - - - - - - - - - - - -25...+55 -
max 230 - Inline mixed-flow - for round air ducts - - galvanized steel no no yes - - - 1670 - 50 2876 max - - Exhaust, Supply 9.8 188 - - IPX4 1 45 - - - - - - - - - - - - - - - - - - - - - - - - - - 464 - - 2018 - - - - - IP20 - - - - 0.84 - - - - - - - - - - - - -25...+55 -