Mode | Voltage | Mounting | Design | Connection diameter | Air duct | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Heating | Length | Current | Maximum air flow | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Max. air flow at air flow direction (perpendicular air flow) | Max. air flow at air flow direction (direct air flow) | Heat exchanger type | Heat exchanger material | Electric heater power | Sound pressure level at 1 m | Sound pressure level at 3 m | Outdoor sound pressure attenuation | Regeneration efficiency | Insulation class | Transported air temperature | Electric heater current | Connected air duct diameter | Transported air temperature | Insulation | Heat recovery efficiency | Sound pressure level at a distance of 1 m | Voltage | Max. unit power without an electric heater | Reheater power consumption | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Extract filter | Supply filter | Motor IP rating | Max. power without electric heater | Max. unit power | Max. unit current without electric heater | Max. unit current | Max. unit power with electric heater | Max. unit current with electric heater | Current | Preheater power consumption | Electric heater current | Remote control panel | Functions | * | Transported air temperature | Perm. amb. temp. | Max. air flow at air flow direction (direct air flow) | Max. air flow at air flow direction (perpendicular air flow) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Box-R 100 V3(1 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | polymer-coated steel | no | no | no | - | - | 0.32 | - | 50 | 1400 | - | 97 | Exhaust, Supply | 3.2 | 20 | 50 | C | IPX4 | - | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 27 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100 V3(2 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | polymer-coated steel | no | no | no | - | - | 0.34 | - | 50 | 1800 | - | 138 | Exhaust, Supply | 3.2 | 26 | 50 | C | IPX4 | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100 V3(3 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | polymer-coated steel | no | no | no | - | - | 0.4 | - | 50 | 2600 | - | 176 | Exhaust, Supply | 3.2 | 45 | 50 | C | IPX4 | - | 44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-V 710 6D | 400 | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | - | 4.87 | 17010 | 50 | 945 | - | - | Exhaust | 114 | 2583 | -25…+70 | - | IPX4 | 3 | 67 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 4725 | - | - | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro-M EC 355 | 230 | Inline | centrifugal | 355 | for round air ducts | polymer-coated steel | yes | no | no | - | - | 3.07 | 3450 | 50/60 | 2768 | - | - | Exhaust, Supply | - | 693 | - | – | IPX4 | 1 | 62 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 958 | - | 15.8 | 2018 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+60 | - | - | - |
Iso-B EC 100 | 230 | Inline | centrifugal | 100 | for round air ducts | galvanized steel | yes | no | yes | - | - | 0.75 | 278 | 50/60 | 3200 | - | - | Exhaust, Supply | - | 92.7 | - | C | IPX4 | 1 | 32 | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+60 | - | - | - | - | - | - | 77 | - | - | 2018 | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
VENTO V50-1 Pro (1 speed) | 220-240 | wall mounting | - | - | 164x164 | - | - | - | - | - | - | 0.021 | 26 | 50 | 599 | - | - | - | - | 3.68 | - | A | IP24 | - | - | - | - | - | - | - | 24 | 14 | 19 | ≤ 90 | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Mechanical | - | - | - | - | - | - |
VENTO V50-1 Pro (2 speed) | 220-240 | wall mounting | - | - | 164x164 | - | - | - | - | - | - | 0.026 | 53 | 50 | 1155 | - | - | - | - | 4.83 | - | A | IP24 | - | - | - | - | - | - | - | 34 | 24 | 19 | ≤ 90 | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Mechanical | - | - | - | - | - | - |
Box-I EC 50x30-1 max | 230 | Inline | centrifugal | - | for rectangular air ducts | galvanized steel | yes | no | yes | - | - | 4.20 | - | 50/60 | 3100 | - | 2700 | Exhaust, Supply | 29.0 | 553 | -25...+50 | – | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2018 | 750 | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT Roto EC DE 650 L/R S21 | 230 | ceiling mounting, wall mounting | - | - | - | galvanized steel | yes | no | yes | - | - | - | 710 | 50/60 | 3600 | - | - | - | - | - | - | A | - | 1 | 36 | - | - | rotary | aluminum | - | - | - | - | - | - | - | 11.2 | 200 | -25...+40 | 40 mm mineral wool | 80–87 | - | - | - | 2800 | 197 | - | 104 | 2016, 2018 | - | G4 | G4, F7 (Option: H13) | - | 367 | 3167 | 2.5 | 13.7 | - | - | - | - | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-7. | - | - | - | - |
Tubo-MZ 315 [50 Hz] | 220-240 | Inline | axial | 315 | for round air ducts | galvanized steel | - | no | no | - | - | 0.75 | 1700 | 50 | 1300 | - | - | Supply and exhaust | 4.84 | 110 | -30 … +40 | – | IPX4 | 1 | 42 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 472 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tubo-MZ 315 [60 Hz] | 220-240 | Inline | axial | 315 | for round air ducts | galvanized steel | - | no | no | - | - | 0.7 | 1650 | 60 | 1365 | - | - | Supply and exhaust | 4.84 | 104 | -30 … +40 | – | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 458 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
CIVIC EC LBE 1200 S21 V.2 | 230 | floor mounting | - | - | - | polymer-coated steel | yes | - | - | electric preheating | - | - | 1240 | 50/60 | - | - | - | Supply and exhaust | 358 | - | - | A | - | 3 | 30 | - | - | counter-flow | polystyrene | - | - | - | - | - | - | -25...+40 | - | 400 | - | 40 mm mineral wool | 84…96* | 40 | - | 345 | - | 344 | - | - | - | - | - | - | - | - | - | 2.3 | - | - | 12 | - | 3150 | - | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
CIVIC EC LBE2 300 | 230 | floor mounting | - | - | - | polymer-coated steel | yes | - | - | electric preheating, electric reheating | - | - | 320 | 50/60 | 2150 | - | - | Supply and exhaust | 140±3% | - | - | A | - | 1 | 21 | - | - | counter-flow | polystyrene | - | - | - | - | - | - | -25...+40 | - | 200 | - | 40 mm mineral wool | 78...92* | 31 | - | 125 | 1400 | 89 | - | - | - | - | G4 x 2 | G4 + F8 (option: F8 C + H11) | - | - | - | 0.9 | - | - | 13.1 | - | 1400 | - | Sensor, LCD | Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
Tower-H 310 4E (50 Hz) | 230 | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | - | 0.64 | 2265 | 50 | 1420 | - | - | Exhaust | 14.2 | 141 | -25…+50 | - | IPX4 | 1 | 47 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 629 | - | - | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-H 310 4E (60 Hz) | 230 | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | - | 0.87 | 2425 | 60 | 1740 | - | - | Exhaust | 14.2 | 195 | -25…+50 | - | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 674 | - | - | – | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix-E 355-4D | 400 | Inline | mixed-flow | 355 | for round air ducts | polymer-coated steel | no | no | yes | - | - | 1.77 | 3430 | 50 | 1490 | - | - | Exhaust, Supply | 33 | 585 | - | - | IPX4 | 3 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+60 | - | - | - | - | - | - | 953 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
S-Vent 280х127-5.5-2D | 400 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | polymer-coated steel | no | yes | no | - | - | 10.7 | 6330 | 50 | 2865 | - | - | Exhaust, Supply | 42.4 | 5500 | +60 | - | IP54 | 3 | 81 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1758 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box 50x25 2E 50 Hz |
230 | Inline | centrifugal | - | for rectangular air ducts | galvanized steel | - | - | - | - | - | 1.32 | 1720 | 50 | 2550 | - | - | Exhaust, Supply | 17.88 | 305 | - | - | IPX4 | 1 | 57 | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+45 | - | - | - | - | - | - | 478 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box 50x25 2E 60 Hz |
230 | Inline | centrifugal | - | for rectangular air ducts | galvanized steel | - | - | - | - | - | 1.65 | 1850 | 60 | 2830 | - | - | Exhaust, Supply | 17.88 | 380 | - | - | IPX4 | 1 | 58 | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+45 | - | - | - | - | - | - | 514 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT EC SB 250-E S21 | 230 | wall mounting, floor mounting | - | - | - | polymer-coated steel | yes | - | - | - | - | - | 390 | 50/60 | - | - | - | - | - | 180 | - | A | - | 1 | 35 | - | - | counter-flow | enthalpy | - | - | - | - | - | - | - | - | 160 | -25...+40 | 30 mm mineral wool | 78...90 | - | - | - | - | 108 | - | 66 | 2018 | - | G4 | G4 (Option: F7) | - | - | - | - | - | - | - | 1.37 | - | - | - | - | - | - | - | - | - |
KOMFORT EC LBE 700-E S21 | 230 | ceiling mounting, floor mounting | - | - | - | galvanized steel | - | - | - | - | - | - | 830 | 50/60 | - | - | - | - | - | - | - | A | - | 1 | 31 | - | - | counter-flow | enthalpy | 3600 | - | - | - | - | - | - | - | 250 | -25…+40 | 40 mm mineral wool | 74–89 | - | - | - | - | 231 | - | 108.4 | - | - | G4 | G4, F7 | - | 336 | - | 2.4 | - | 3936 | 18.0 | - | - | 15.6 | - | - | - | - | - | - | - |
Iso-V 500 4Е | 230 | Inline | centrifugal | - | for rectangular air ducts, for round air ducts | aluminium, aluzinc | no | yes | yes | - | - | 5.70 | - | 50 | 1320 | - | - | Exhaust, Supply | 52 | 1300 | - | - | IPX4 | 1 | 55 | 7330 | 6680 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | – | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | -20...+50 | - | 1856 | 2036 |
TwinBox EC 150 | 220-240 | Inline | mixed-flow | - | for round air ducts | galvanized steel | yes | no | yes | - | - | 0.48 | 450 | 50/60 | 3390 | - | - | Exhaust | 28 | 56 | –25…+55 | - | IPX4 | 1 | 37.5 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 125 | - | - | 2016, 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
SD 125/900 | - | - | - | 125 | for round air ducts | galvanized steel | - | - | - | - | 900 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 4.1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-QR 450 4D 50 Hz |
400 | wall mounting | axial | 450 | for round air ducts | polymer-coated steel | no | no | no | - | - | - | 5280 | 50 | 1360 | - | - | Exhaust, Supply | - | 250 | - | - | IPX4 | 3 | 56 | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | 1467 | - | 10.0 | - | - | - | - | IP44 | - | - | - | - | - | - | 0.6 | - | - | - | - | - | - | - | - | - |
Axis-QR 450 4D 60 Hz |
400 | wall mounting | axial | 450 | for round air ducts | polymer-coated steel | no | no | no | - | - | - | 5350 | 60 | 1620 | - | - | Exhaust, Supply | - | 275 | - | - | IPX4 | 3 | 56 | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | 1486 | - | 10.0 | - | - | - | - | IP44 | - | - | - | - | - | - | 0.65 | - | - | - | - | - | - | - | - | - |
Qubit-E 55/110min | - | ceiling mounting, wall mounting | centrifugal | - | 100 | plastic | no | no | no | - | - | 0.081 | 55 | 50 | - | min | - | Exhaust | - | 11 | - | - | IP45 | - | 20 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 15 | 0.72 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - |
Qubit-E 55/110max | - | ceiling mounting, wall mounting | centrifugal | - | 100 | plastic | no | no | no | - | - | 0.116 | 110 | 50 | - | max | - | Exhaust | - | 26 | - | - | IP45 | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 31 | 0.85 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - |
KOMFORT Roto EC D2 350 S18 | 230 | - | - | - | - | painted steel | - | - | - | - | - | - | 400 | 50/60 | 3200 | - | - | - | - | - | - | A | - | 1 | 33 | - | - | rotary | aluminum | - | - | - | - | - | - | - | - | 160 | -25...+40 | 20 mm mineral wool | 73–87 | - | - | - | - | 111 | - | 78 | 2016, 2018 | - | G4 | G4 + F7 (Option: H13) | - | 200 | 200 | 1.3 | 1.3 | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-AL 315 (60 Hz) | 230 | for roof | axial | - | for round air ducts | polymer-coated steel | no | yes | no | - | - | 0.7 | 1650 | 60 | 1365 | - | - | Exhaust | 11.5 | 104 | 40 | C | IP24 | 1 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 458 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-AL 315 (50 Hz) | 230 | for roof | axial | - | for round air ducts | polymer-coated steel | no | yes | no | - | - | 0.75 | 1700 | 50 | 1300 | - | - | Exhaust | 11.5 | 110 | 40 | C | IP24 | 1 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 472 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 80 V3(1 speed) | 230 | Inline | centrifugal | 80 | for round air ducts | polymer-coated steel | no | no | no | - | - | 0.32 | - | 50 | 1400 | - | 88 | Exhaust, Supply | 3.2 | 20 | 50 | C | IPX4 | - | 32 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 24 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 80 V3(2 speed) | 230 | Inline | centrifugal | 80 | for round air ducts | polymer-coated steel | no | no | no | - | - | 0.34 | - | 50 | 1800 | - | 130 | Exhaust, Supply | 3.2 | 26 | 50 | C | IPX4 | - | 35 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 80 V3(3 speed) | 230 | Inline | centrifugal | 80 | for round air ducts | polymer-coated steel | no | no | no | - | - | 0.4 | - | 50 | 2600 | - | 162 | Exhaust, Supply | 3.2 | 45 | 50 | C | IPX4 | - | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauAIR CFH 800 | 200-240 | floor mounting, outdoor mounting | - | - | for round air ducts | aluzinc | yes | yes | yes | - | - | - | 800 | 50/60 | 2800 | - | - | Supply and exhaust | - | 2x270 | - | - | IP34 | 1 | 34 | - | - | - | - | - | - | - | - | - | B | - | - | - | -25...+40 | - | - | - | - | - | - | - | - | 230 | - | - | ePM1 ≥ 50% (ISO 16890) | F7 (EN 779) | IP54 | - | - | - | 2.5 | - | - | - | - | - | - | - | - | - | -35...+50 | - | - |