Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Heating | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Heat exchanger type | Heat exchanger material | Electric heater power | Sound pressure level at 1 m | Sound pressure level at 3 m | Outdoor sound pressure attenuation | Regeneration efficiency | Number of electrical heating elements | Transported air temperature | Electric heater current | Connected air duct diameter | Filter | Transported air temperature | Number of water coil rows | Insulation | Heat recovery efficiency | Sound pressure level at a distance of 1 m | Voltage | Max. unit power without an electric heater | Reheater power consumption | Insulation thikness | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Extract filter | Supply filter | Motor IP rating | PM 2.5 Ratio | Max. power without electric heater | Max. unit power | Max. unit current without electric heater | Max. unit current | Max. unit power with electric heater | Max. unit current with electric heater | Current | Preheater power consumption | Sound pressure level at 3 m in accordance with ISO 3741:2004 | Filter | Remote control panel | Functions | Power | Cable cross section | * | Motor max. power | *** | ** | Max. water temperature | Water coil connection diameter |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CIVIC EC LB 300 S14 | 230 | - | floor mounting | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | 320 | - | 50/60 | 2150 | - | - | Supply and exhaust | 138±3% | - | - | A | - | 1 | 21 | counter-flow | polystyrene | - | - | - | - | - | - | -25...+40 | - | 200 | - | - | - | 40 mm mineral wool | 78...92* | 31 | - | 125 | - | - | 89 | - | - | - | - | G4 x 2 | G4 + F8 (option: F8 C + H11) | - | - | - | - | 0.9 | - | - | 0.9 | - | - | - | - | Sensor | Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - |
Tower-H 500 4D | 400 | - | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 2.64 | - | 8435 | - | 50 | 1460 | - | - | Exhaust | 46.6 | 1527 | -30…+50 | - | IPX4 | 3 | 62 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2343 | - | - | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Quatro Hi-Tech Gold 125 (127-220V/60Hz) | 127 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | 0.119 | 16 | 170 | 35* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.34 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
Quatro Hi-Tech Gold 125 (127-220V/60Hz) | 220 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | 0.102 | 15 | 170 | 35* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.32 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
Ceileo 300 (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | 0.15 | 31 | 220 | 28* | 50 | 936 | min | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 61 | 0.51 | 5.1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
Ceileo 300 (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | 0.22 | 49 | 300 | 31* | 50 | 1254 | max | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 83 | 0.59 | 5.1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
Ceileo 300 (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | 0.17 | 35 | 200 | 27* | 60 | 888 | min | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 56 | 0.63 | 5.1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
Ceileo 300 (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | 0.28 | 63 | 320 | 32* | 60 | 1320 | max | - | Exhaust | - | - | - | - | IPX4, IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 89 | 0.71 | 5.1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
S-Vent 180х74-0.55-4D | 400 | - | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | polymer-coated steel | no | yes | no | - | 1.6 | - | 1030 | - | 50 | 1360 | - | - | Exhaust, Supply | 13.5 | 550 | +60 | D | IP54 | 3 | 64 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 286 | - | - | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box 150 | 230 | - | Inline | centrifugal | 150 | for round air ducts | polymer-coated steel | no | no | no | - | 0.38 | - | - | - | 50 | 2600 | - | 553 | Exhaust, Supply | 6.35 | 85 | -25 +40 | B | IPX4 | - | 50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Trio 100 | - | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | 0.05 | - | 90 | 29* | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | 25 | 0.32 | 0.45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
VENTO Ergo A50-1 S Pro (1 speed) |
100-230 | - | wall mounting | - | - | 150 | - | - | - | - | - | 0.024 | - | 21 | - | 50/60 | 610 | - | - | - | - | 4.5 | - | A | IP24 | - | - | - | - | - | 22 | 13 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo A50-1 S Pro (2 speed) |
100-230 | - | wall mounting | - | - | 150 | - | - | - | - | - | 0.026 | - | 32 | - | 50/60 | 800 | - | - | - | - | 5 | - | A | IP24 | - | - | - | - | - | 29 | 20 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo A50-1 S Pro (3 speed) |
100-230 | - | wall mounting | - | - | 150 | - | - | - | - | - | 0.039 | - | 50 | - | 50/60 | 1450 | - | - | - | - | 7 | - | A | IP24 | - | - | - | - | - | 32 | 23 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
Box-I EC 50x30-1 max | 230 | - | Inline | centrifugal | - | for rectangular air ducts | galvanized steel | yes | no | yes | - | 4.20 | - | - | - | 50/60 | 3100 | - | 2700 | Exhaust, Supply | 29.0 | 553 | -25...+50 | – | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2018 | 750 | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-HC 190 2E (50 Hz) | 230 | - | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 0.29 | - | 670 | - | 50 | 2730 | - | - | Exhaust | - | 64 | -25…+50 | – | IPX4 | 1 | 48 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 186 | - | 6 | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-HC 190 2E (60 Hz) | 230 | - | for roof | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 0.40 | - | 700 | - | 60 | 2980 | - | - | Exhaust | - | 89 | -25…+50 | – | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 194 | - | 6 | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BLAUBOX E 800-6 Pro | 400 | - | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for round air ducts | aluzinc | no | no | yes | - | - | - | 810 | - | 50 | 2780 | - | - | Supply | - | - | - | C | - | 3 | 30 | - | - | 6000 | - | - | - | - | 3 | -25...+40 | 8.7 | 200 | G4 | - | - | 25 mm mineral wool | - | - | - | - | - | - | 225 | - | 52 | 2016, 2018 | - | - | - | - | - | 193 | - | 0.84 | - | 6193 | 9.54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-F 300 2D 50 Hz |
400 | - | Inline | axial | 300 | for round air ducts | polymer-coated steel | no | no | no | - | - | - | 2310 | - | 50 | 2350 | - | - | Exhaust, Supply | - | 145 | - | - | IPX4 | 3 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | 642 | - | 5.7 | - | - | - | - | IP44 | - | - | - | - | - | - | - | 0.25 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-F 300 2D 60 Hz |
400 | - | Inline | axial | 300 | for round air ducts | polymer-coated steel | no | no | no | - | - | - | 2390 | - | 60 | 2570 | - | - | Exhaust, Supply | - | 165 | - | - | IPX4 | 3 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | 664 | - | 5.7 | - | - | - | - | IP44 | - | - | - | - | - | - | - | 0.29 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Aero Still Vintage 150 | 220-240 | Vintage | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | 19 | 254 | 33 | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 71 | 0.27 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso Box-F 100 G4-F8 V2 min | 230 | - | ceiling mounting, wall mounting | centrifugal | 100 | for round air ducts | polymer-coated steel | no | no | yes | - | 0.15 | - | 150 | - | 50 | 700 | min | - | Supply | 14.16 | 33 | - | E | IPX4 | 1 | 14 | - | - | - | - | - | - | - | - | - | - | - | - | -25…+40 | - | - | - | - | - | - | - | - | 42 | - | - | - | - | - | - | - | 94 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso Box-F 100 G4-F8 V2 max | 230 | - | ceiling mounting, wall mounting | centrifugal | 100 | for round air ducts | polymer-coated steel | no | no | yes | - | 0.19 | - | 175 | - | 50 | 1200 | max | - | Supply | 14.16 | 41 | - | E | IPX4 | 1 | 23 | - | - | - | - | - | - | - | - | - | - | - | - | -25…+40 | - | - | - | - | - | - | - | - | 49 | - | - | - | - | - | - | - | 93 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-H EC 355 | 230 | - | for roof | centrifugal | - | for round air ducts, for square air ducts | polymer-coated steel | yes | yes | no | - | 9.36 | - | 3830 | - | 50/60 | 1550 | - | - | Exhaust | - | 669 | -25...+50 | – | IPX4 | 1 | 51 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1064 | - | 27 | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Тurbo 150 min | 230 | - | Inline | mixed-flow | 150 | for round air ducts | plastic | no | no | no | - | 0.19 | - | 430 | - | 50/60 | 1940 | - | - | Exhaust, Supply | 3.18 | 42 | 60 | B | IPX4 | 1 | 32 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 119 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Turbo 150 max | 230 | - | Inline | mixed-flow | 150 | for round air ducts | plastic | no | no | no | - | 0.22 | - | 560 | - | 50/60 | 2620 | - | - | Exhaust, Supply | 3.18 | 50 | 60 | B | IPX4 | 1 | 44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 156 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo Compact DC 110 | 120-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | 0.18 | 19 | 187 | 23-25* | 50/60 | 1100 | - | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 52 | 0.37 | 5.3 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | For fans with humidity or motion sensors | - | - | - |
Valeo 35/60 (1 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | plastic | no | no | no | - | 0.12 | - | 35 | 27* | 50 | - | I | - | Exhaust | - | 15 | +50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | 10 | - | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3×1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
Valeo 35/60 (2 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | plastic | no | no | no | - | 0.14 | - | 63 | 36* | 50 | - | II | - | Exhaust | - | 25 | +50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | 18 | - | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3×1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
Box-D 150 (50 Hz) | 230 | - | Inline | centrifugal | 150 | for round air ducts | galvanized steel | no | no | no | - | 0.5 | - | - | - | 50 | 2465 | - | 485 | Exhaust | 6.5 | 112 | -25 +50 | - | IPX4 | 1 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-D 150 (60 Hz) | 230 | - | Inline | centrifugal | 150 | for round air ducts | galvanized steel | no | no | no | - | 0.6 | - | - | - | 60 | 2550 | - | 531 | Exhaust | 6.5 | 136 | -25 +50 | - | IPX4 | 1 | 53 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Blaubox EC MW 700 S31 | 230 | - | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for round air ducts | aluzinc | yes | no | - | - | - | - | 800 | - | 50 | - | - | - | Supply | - | - | - | - | - | 1 | 44 | - | - | - | - | - | - | - | - | -30…+40 | - | 250 | - | - | 4 | 30 mm mineral wool | - | - | - | - | - | - | - | - | 27 | 2018 | - | - | - | - | - | - | 139 | - | 1.05 | - | - | - | - | - | Coarce 90% / G4 (option: ePM1 70% / F7) | - | - | - | - | - | - | - | - | 150 | 3/4 |
KOMFORT Roto EC LE 400-2 S18 | 230 | - | - | - | - | - | aluzinc | - | - | - | - | - | - | 400 | - | 50/60 | 3100 | - | - | - | - | - | - | A | - | 1 | 45 | rotary | aluminum | 2000 | - | - | - | - | - | - | - | 160 | - | -25...+40 | - | 20 mm mineral wool | 80–95 | - | - | - | - | - | 111 | - | 112 | 2016, 2018 | - | G4 | G4 | - | - | - | - | - | - | 2290 | 9.9 | - | - | - | - | - | - | - | - | - | 2 items x 100 | - | - | - | - |
Iso-ZS 250 6E | 230 | - | - | centrifugal | - | for round air ducts | galvanized steel | no | no | yes | - | 0.55 | - | - | - | 50 | 860 | - | 1210 | Exhaust, Supply | 30.0 | 120 | -20…+50 | C | IPX4 | 1 | 40 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2018 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ducto-U Power Plus 150 min | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | 0.103 | 22 | 285 | 38* | 50/60 | 2300 | - | - | Exhaust, Supply | 1.3 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
Ducto-U Power Plus 150 max | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | 0.109 | 25 | 375 | 41* | 50/60 | 2600 | - | - | Exhaust, Supply | 1.3 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - | - | - |
Freshbox 100 black Speed I |
110-240 | - | wall mounting | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | 30 | - | 50/60 | 2200 | I | - | - | 31 | - | - | A | - | 1 | - | counter-flow | polystyrene | - | - | - | - | - | - | - | - | 100 | - | -20...+40 | - | - | 98 | - | - | - | - | 10 | 8 | - | - | - | - | G4 | G4, F8 (Option: F8 C, H13) | - | - | 12 | - | 0.4 | - | - | - | - | - | 13 | - | LCD | Filter replacement indication, Timer, Weekly schedule | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - |
Freshbox 100 black Speed II |
110-240 | - | wall mounting | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | 60 | - | 50/60 | 2200 | II | - | - | 31 | - | - | A | - | 1 | - | counter-flow | polystyrene | - | - | - | - | - | - | - | - | 100 | - | -20...+40 | - | - | 92 | - | - | - | - | 10 | 17 | - | - | - | - | G4 | G4, F8 (Option: F8 C, H13) | - | - | 21 | - | 0.4 | - | - | - | - | - | 27 | - | LCD | Filter replacement indication, Timer, Weekly schedule | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - |
Freshbox 100 black Speed III |
110-240 | - | wall mounting | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | 100 | - | 50/60 | 2200 | III | - | - | 31 | - | - | A | - | 1 | - | counter-flow | polystyrene | - | - | - | - | - | - | - | - | 100 | - | -20...+40 | - | - | 89 | - | - | - | - | 10 | 28 | - | - | - | - | G4 | G4, F8 (Option: F8 C, H13) | - | - | 45 | - | 0.4 | - | - | - | - | - | 39 | - | LCD | Filter replacement indication, Timer, Weekly schedule | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - |
Tower-H 250 4E | 230 | - | Inline | centrifugal | - | for round air ducts | polymer-coated steel | no | yes | no | - | 0.23 | - | 820 | - | 50 | 1440 | - | - | Exhaust | 12.1 | 48 | -25…+50 | – | IPX4 | 1 | 46 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 228 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |