Selected 1023 products
Mode VoltageStyleMountingDesignConnection diameterAir ductWidthHeightCasing materialEC motorOutdoor mountingSound-insulated casingHeatingCurrentPowerMaximum air flowSound pressure levelFrequencyRPMSpeedMaximum air capacityTypeWeight PowerMax. operating temperatureSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeCable cross sectionHeat exchanger materialElectric heater powerSound pressure level at 1 mSound pressure level at 3 mNumber of electrical heating elementsTransported air temperature Electric heater currentConnected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeFilterTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140Regeneration efficiency in accordance with DIBt LÜ-A 20InsulationHeat recovery efficiencySound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionMaximum air flowSFPWeightErPMaximum air flowExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeMotor IP ratingPM 2.5 RatioMax. power without electric heaterMax. unit current without electric heaterMax. unit power with electric heaterMax. unit current with electric heaterCurrentPreheater power consumptionFilterRemote control panelFunctions*Motor max. power***Transported air temperature
Iso-ZS 315/2x250 6E max 230 - - centrifugal - for round air ducts - - galvanized steel no no yes - 5.06 - - - 50 970 - 3850 Exhaust, Supply 45.0 953 -20…+50 - IPX4 1 43 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Aero Gold 125 220-240 Gold ceiling mounting, wall mounting axial 125 - - - - - - - - 0.1 16 193 39* 50 2400 - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 54 0.3 - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - -
CIVIC EC LBE2 300-E S21 230 - floor mounting - - - - - polymer-coated steel yes - - electric preheating, electric reheating - - 320 - 50/60 2150 - - Supply and exhaust 138±3% - - A - 1 21 counter-flow - enthalpy - - - - -25...+40 - 200 - - - - - - 40 mm mineral wool 73...89* 31 - 125 1400 89 - - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - - 0.9 - 13.1 - 1400 - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Tower-H 560 6E 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - 2.70 - 9560 - 50 930 - - Exhaust 76.4 613 -25…+50 - IPX4 1 58 - - - - - - - - - - - - - - - - - - - - - - 2656 - - 2018 - - - - - IP54 - - - - - - - - - - - - - -
Quatro Hi-Tech Gold 125 (127-220V/60Hz) 127 Hi-Tech Gold ceiling mounting, wall mounting axial 125 - - - - - - - - 0.119 16 170 35* 60 2400 - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 47 0.34 - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - -
Quatro Hi-Tech Gold 125 (127-220V/60Hz) 220 Hi-Tech Gold ceiling mounting, wall mounting axial 125 - - - - - - - - 0.102 15 170 35* 60 2400 - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 47 0.32 - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - -
Ceileo DC 150 120-240 - ceiling mounting centrifugal - - - - - - - - - 0.24 (0.39) 26 254 23-29* 50/60 1100 - - Exhaust - - - B*** IPX2 - - - - - - - - - - - - - - - - - - - - - - - - 71 0.37 5.1 - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - For fans with humidity or motion sensors -
S-Vent 225х103-1.1-4D 400 - floor mounting centrifugal - for rectangular air ducts, for round air ducts - - polymer-coated steel no yes no - 2.8 - 2125 - 50 1420 - - Exhaust, Supply 21.2 1100 +60 - IP54 3 72 - - - - - - - - - - - - - - - - - - - - - - 590 - - - - - - - - IP54 - - - - - - - - - - - - - -
Box-R 150 1 ~ 230 - Inline centrifugal 150 for round air ducts - - polymer-coated steel no no no - 0.52 - - - 50 1050 - 536 Exhaust, Supply 7.1 113 50 C IPX4 - 46 - - - - - - - - - - - - - - - - - - - - - - - - - - 149 - - - - - - - - - - - - - - - - - - -
Box-I 40x20 2E
50 Hz
230 - Inline centrifugal - for rectangular air ducts - - galvanized steel - - - - 0.6 - 930 - 50 2600 - - Exhaust, Supply 24.5 138 - - IPX4 1 45 - - - - - - - - - - - - - -25…+45 - - - - - - - - 258 - - 2018 - - - - - IP44 - - - - - - - - - - - - - -
Box-I 40x20 2E
60 Hz
230 - Inline centrifugal - for rectangular air ducts - - galvanized steel - - - - 0.88 - 1070 - 60 2850 - - Exhaust, Supply 24.5 200 - - IPX4 1 47 - - - - - - - - - - - - - -25…+45 - - - - - - - - 297 - - 2018 - - - - - IP44 - - - - - - - - - - - - - -
VENTO Expert A50-1 Pro (1 speed) 100-230 - wall mounting - - 160 - - - - - - - 0.025 - - - 50/60 800 - - - - 3.61 - A IP24 - - - - - - 20 11 - - - - 15 8 - - 42 ≤ 93 - - - - - - - 1.73 - - - - - 4 2 - - - - - - - - G3 (option: pollen filter) - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - -20...+40
VENTO Expert A50-1 Pro (2 speed) 100-230 - wall mounting - - 160 - - - - - - - 0.03 - - - 50/60 1300 - - - - 4.15 - A IP24 - - - - - - 27 18 - - - - 30 15 - - 42 ≤ 93 - - - - - - - 1 - - - - - 8 4 - - - - - - - - G3 (option: pollen filter) - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - -20...+40
VENTO Expert A50-1 Pro (3 speed) 100-230 - wall mounting - - 160 - - - - - - - 0.039 - - - 50/60 1900 - - - - 5.20 - A IP24 - - - - - - 30 21 - - - - 50 25 - - 42 ≤ 93 - - - - - - - 0.75 - - - - - 14 7 - - - - - - - - G3 (option: pollen filter) - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - -20...+40
Box-I EC 40x20-1 230 - Inline centrifugal - for rectangular air ducts - - galvanized steel yes no yes - 0.69 - - - 50/60 2470 - 810 Exhaust, Supply 15.1 91 -25...+50 B IPX4 1 33 - - - - - - - - - - - - - - - - - - - - - - - - - 2018 225 - - - - IP55 - - - - - - - - - - - - - -
Tower-HC 225 4E (50 Hz) 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - 0.22 - 760 - 50 1400 - - Exhaust - 49 -25…+50 IPX4 1 45 - - - - - - - - - - - - - - - - - - - - - - 211 - 7 2018 - - - - - IP44 - - - - - - - - - - - - - -
BLAUBOX E 1500-6 Pro 400 - ceiling mounting, wall mounting, floor mounting centrifugal - for round air ducts - - aluzinc no no yes - - - 1520 - 50 2720 - - Supply - - - - - 3 30 - - - 6000 - - 3 -25...+40 8.7 315 - - G4 - - - 25 mm mineral wool - - - - - 422 - 62 2016, 2018 - - - - - - - 296 1.34 6296 10.04 - - - - - - - - -
Axis-F 450 4D
50 Hz
400 - Inline axial 450 for round air ducts - - polymer-coated steel no no no - - - 5280 - 50 1360 - - Exhaust, Supply - 250 - - IPX4 3 56 - - - - - - - - - - - - - -30...+60 - - - - - - - - 1467 - 9.1 - - - - - - IP44 - - - - - 0.6 - - - - - - - -
Axis-F 450 4D
60 Hz
400 - Inline axial 450 for round air ducts - - polymer-coated steel no no no - - - 5350 - 60 1620 - - Exhaust, Supply - 275 - - IPX4 3 56 - - - - - - - - - - - - - -30...+50 - - - - - - - - 1486 - 9.1 - - - - - - IP44 - - - - - 0.65 - - - - - - - -
Aero Still Vintage 150 220-240 Vintage ceiling mounting, wall mounting axial 150 - - - - - - - - - 19 254 33 50 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 71 0.27 - - - - - - - - - - - - - - - - - - - - - -
Iso Box-F 150 G4-F8 L V2 min 230 - ceiling mounting, wall mounting centrifugal 150 for round air ducts - - polymer-coated steel no no yes - 0.18 - 215 - 50 700 min - Supply 14.17 41 - C IPX4 1 15 - - - - - - - - - - - - - -25…+40 - - - - - - - - 60 - - 2018 - - - - - - 90 - - - - - - - - - - - - -
Iso Box-F 150 G4-F8 L V2 max 230 - ceiling mounting, wall mounting centrifugal 150 for round air ducts - - polymer-coated steel no no yes - 0.22 - 310 - 50 1200 max - Supply 14.17 50 - C IPX4 1 25 - - - - - - - - - - - - - -25…+40 - - - - - - - - 86 - - 2018 - - - - - - 87 - - - - - - - - - - - - -
Tower-H EC 560 400 - for roof centrifugal - for round air ducts, for square air ducts - - polymer-coated steel yes yes no - 3.83 - 13640 - 50/60 1540 - - Exhaust - 2412 -25...+60 IPX4 3 69 - - - - - - - - - - - - - - - - - - - - - - 3789 - 71 2018 - - - - - IP54 - - - - - - - - - - - - - -
Тurbo 150 min 230 - Inline mixed-flow 150 for round air ducts - - plastic no no no - 0.19 - 430 - 50/60 1940 - - Exhaust, Supply 3.18 42 60 B IPX4 1 32 - - - - - - - - - - - - - - - - - - - - - - 119 - - 2018 - - - - - IP44 - - - - - - - - - - - - - -
Turbo 150 max 230 - Inline mixed-flow 150 for round air ducts - - plastic no no no - 0.22 - 560 - 50/60 2620 - - Exhaust, Supply 3.18 50 60 B IPX4 1 44 - - - - - - - - - - - - - - - - - - - - - - 156 - - 2018 - - - - - IP44 - - - - - - - - - - - - - -
Box-FI 40x20 4D 400 - Inline centrifugal - for rectangular air ducts 400 200 galvanized steel no no yes - 0.60 - 1470 - 50 1300 - - Exhaust, Supply - 282 - - IPX4 3 41 - - - - - - - - - - - - - -25...+45 - - - - - - - - 408 - 29 - - - - - - IP44 - - - - - - - - - - - - - -
Valeo-BF 35/60
(2 speed)
220-240 - ceiling mounting, wall mounting centrifugal - for round air ducts - - plastic no no no - 0.14 - 63 - 50 - II - Exhaust - 25 +50 - IP55 - 36 - 3х1.5 - - - - - - - - - - - - - - - - - - - - 18 - - - - - - - - - - - - - - - - - - - - - - -
Valeo-BF 35/60
(1 speed)
220-240 - ceiling mounting, wall mounting centrifugal - for round air ducts - - plastic no no no - 0.12 - 35 - 50 - I - Exhaust - 15 +50 - IP55 - 27 - 3х1.5 - - - - - - - - - - - - - - - - - - - - 10 - - - - - - - - - - - - - - - - - - - - - - -
Extero 160
50 Hz
230 - Inline centrifugal 160 for round air ducts - - polymer-coated steel no yes no - 0.41 - 650 - 50 2440 - - Exhaust - 95 +55 B IPX4 1 60 - - - - - - - - - - - - - - - - - - - - - - 181 - 4.5 2018 - - - - - IP44 - - - - - - - - - - - - - -
Extero 160
60 Hz
230 - Inline centrifugal 160 for round air ducts - - polymer-coated steel no yes no - 0.42 - 685 - 60 2400 - - Exhaust - 96 +55 B IPX4 1 60 - - - - - - - - - - - - - - - - - - - - - - 190 - 4.5 2018 - - - - - IP44 - - - - - - - - - - - - - -
Axis-Q EC 300 230 - wall mounting axial 317 for round air ducts - - polymer-coated steel yes no no - - - 2400 - 50/60 2000 - - Supply and exhaust - 150 - - IPX5 1 57 - - - - - - - - - - - - - –25…+60 - - - - - - - - 667 - 3.4 - - - - - - IP55 - - - - - 1.2 - - - - - - - -
KOMFORT Roto EC LE 1200-6 S18 400 - - - - - - - aluzinc - - - - - - 1200 - 50/60 1930 - - - - - - - - 3 60 rotary - aluminum 6000 - - - - - 315 - - - -25...+40 - - 20 mm mineral wool 73–95 - - - - 333 - 165 2016, 2018 - G4 G4 - - - - - - 6570 9.5 - - - - - - 2 items x 208 - -
Iso-ZS 315 6E 230 - - centrifugal - for round air ducts - - galvanized steel no no yes - 2.04 - - - 50 920 - 2460 Exhaust, Supply 31.0 402 -20…+50 - IPX4 1 42 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ducto-U Power Plus 150 min 220-240 White Inline axial 150 - - - - - - - - 0.103 22 285 38* 50/60 2300 - - Exhaust, Supply 1.3 - - - - - - - - - - - - - - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - -
Ducto-U Power Plus 150 max 220-240 White Inline axial 150 - - - - - - - - 0.109 25 375 41* 50/60 2600 - - Exhaust, Supply 1.3 - - - - - - - - - - - - - - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - - -