Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Form | Length | Material | Device | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Cable cross section | Transported air temperature | Sectional size | Voltage | Regulator | Air pass | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Motor IP rating | LED-light power | Cable cross section | * | *** |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BlauPlast RS 125/150 | - | - | - | - | - | for round air ducts | - | - | - | - | - | - | round | 60 | plastic | reducer | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RVK 125 | - | - | - | - | 125 | for round air ducts | - | - | - | - | - | - | round | 62 | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Aero Vintage 100 (127-220V/60Hz) | 127 | Vintage | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.115 | 10 | 92 | 34 | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 26 | 0.39 | - | - | - | - | - | - | - | - |
Aero Vintage 100 (127-220V/60Hz) | 220 | Vintage | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.054 | 9 | 92 | 34 | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 26 | 0.35 | - | - | - | - | - | - | - | - |
Centro 150 60 Hz | 230 | - | Inline | centrifugal | 150 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.33 | - | 505 | - | 60 | 2940 | - | - | Exhaust, Supply | - | 73 | -25...+50 | – | IPX4 | 1 | 43 | - | - | - | - | - | - | 140 | - | 2.45 | - | - | IP44 | - | - | - | - |
Centro 150 50 Hz | 230 | - | Inline | centrifugal | 150 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.29 | - | 460 | - | 50 | 2628 | - | - | Exhaust, Supply | - | 65 | -25...+55 | B | IPX4 | 1 | 42 | - | - | - | - | - | - | 128 | - | 2.45 | 2018 | - | IP44 | - | - | - | - |
Art 125 | 220-240 | - | wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 16 | 185 | 38 | - | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - |
Valeo-BF 35/100 (2 speed) |
220-240 | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.18 | - | 102 | - | 50 | - | II | - | Exhaust | - | 44 | +50 | - | IP55 | - | 46 | 3х1.5 | - | - | - | - | - | 28 | - | - | - | - | - | - | - | - | - |
Valeo-BF 35/100 (1 speed) |
220-240 | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.12 | - | 35 | - | 50 | - | I | - | Exhaust | - | 15 | +50 | - | IP55 | - | 27 | 3x1.5 | - | - | - | - | - | 10 | - | - | - | - | - | - | - | - | - |
Decor 180x250s | - | - | wall mounting | rectangular flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | no regulator | 0.0146 | - | - | - | - | - | - | - | - | - | - |
BlauPlast US 100/110x55 | - | - | - | - | 100 | for rectangular air ducts, for round air ducts | - | - | - | - | - | - | round, rectangular | - | plastic | reducer | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 55х110 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Deco 150 | 220-240 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 24 | 298 | 40* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 83 | 0.29 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-R 200 | 1 ~ 230 | - | Inline | centrifugal | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.61 | - | - | - | 50 | 950 | - | 783 | Exhaust, Supply | 8.8 | 139 | 50 | C | IPX4 | - | 47 | - | - | - | - | - | - | - | - | - | - | 218 | - | - | - | - | - |
BlauPlast RS 80/100 | - | - | - | - | - | for round air ducts | - | - | - | - | - | - | round | 60 | plastic | reducer | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo DC 110 | 120-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.18 (0.3) | 19 | 187 | 23-25* | 50/60 | 1100 | - | - | Exhaust | - | - | - | B*** | IPX2 | - | - | - | - | - | - | - | - | 52 | 0.37 | 5.3 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Bravo Still Platinum 125 | 220-240 | Platinum | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.006 | 9.3 | 115 | 31* | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 32 | 0.29 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Centro 200 V2 min |
230 | - | Inline | centrifugal | 200 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.27 | - | 430 | - | - | 1920 | - | - | Exhaust, Supply | - | 83 | -25...+55 | C | IPX4 | 1 | 42 | - | - | - | - | - | - | 119 | - | 3.00 | 2018 | - | IP44 | - | - | - | - |
Centro 200 V2 max |
230 | - | Inline | centrifugal | 200 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.43 | - | 741 | - | - | 2470 | - | - | Exhaust, Supply | - | 95 | -25...+55 | C | IPX4 | 1 | 42 | - | - | - | - | - | - | 206 | - | 3.00 | 2018 | - | IP44 | - | - | - | - |
BlauPlast RR 125/1.5 | - | - | - | - | 125 | - | - | - | - | - | - | - | round | 1500 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Line 120 | 220-240 | White | ceiling mounting, wall mounting | axial | 120 | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 17 | 174 | 36* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 48 | 0.35 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Chrome 125 | 220-240 | Chrome | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 16 | 193 | 39* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 54 | 0.3 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
DECOR 81x136 | - | - | - | - | - | for rectangular air ducts | - | - | - | - | - | - | rectangular | - | plastic | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Slim 120 | 220-240 | White | ceiling mounting, wall mounting | axial | 120 | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 17 | 184 | 35* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 51 | 0.33 | 0.73 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box 160 | 230 | - | Inline | centrifugal | 160 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.38 | - | - | - | 50 | 2600 | - | 553 | Exhaust, Supply | 6.6 | 85 | -25 +40 | B | IPX4 | - | 50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RVP 100 | - | - | - | - | 100 | for round air ducts | - | - | - | - | - | - | round | - | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo 250 Light T (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.12 | 23 | 170 | 25* | 50 | 756 | min | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | 47 | 0.49 | 6.4 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 250 Light T (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.18 | 39 | 260 | 29* | 50 | 1122 | max | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | 72 | 0.54 | 6.4 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 250 Light T (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.14 | 25 | 160 | 25* | 60 | 732 | min | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | 44 | 0.56 | 6.4 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 250 Light T (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.22 | 50 | 270 | 30* | 60 | 1140 | max | - | Exhaust | - | - | - | C*** | IPX4, IPX2 | - | - | - | - | - | - | - | - | 75 | 0.67 | 6.4 | - | - | - | 2 х 10 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Bravo Still 150 | 220-240 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 20 | 235 | 35* | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 65 | 0.31 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Turbo 250 min | 230 | - | Inline | mixed-flow | 250 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.54 | - | 1070 | - | 50/60 | 1955 | - | - | Exhaust, Supply | 7.83 | 125 | 60 | – | IPX4 | 1 | 44 | - | - | - | 220-240 | - | - | 297 | - | - | 2018 | - | IP44 | - | - | - | - |
Turbo 250 max | 230 | - | Inline | mixed-flow | 250 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.79 | - | 1360 | - | 50/60 | 2440 | - | - | Exhaust, Supply | 7.83 | 177 | 60 | – | IPX4 | 1 | 51 | - | - | - | 220-240 | - | - | 378 | - | - | 2018 | - | IP44 | - | - | - | - |
BlauPlast RR 100/2 | - | - | - | - | 100 | - | - | - | - | - | - | - | round | 2000 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 465x124T-2 | - | - | door mounting | - | - | - | - | - | - | - | - | - | rectangular | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Aero 150 | 220-240 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 24 | 309 | 40* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 86 | 0.28 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
BlauPlast RBF 125 | - | - | - | - | 125 | for round air ducts | - | - | - | - | - | - | round | 62 | plastic | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Quatro Hi-Tech Chrome 150 (127-220V/60Hz) | 127 | Hi-Tech Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.175 | 25 | 240 | 37* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 67 | 0.37 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Hi-Tech Chrome 150 (127-220V/60Hz) | 220 | Hi-Tech Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.338 | 25 | 240 | 37* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 67 | 0.37 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Valeo 35/60 (1 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.12 | - | 35 | 27* | 50 | - | I | - | Exhaust | - | 15 | +50 | - | - | - | - | - | - | - | 220-240 | - | - | 10 | - | - | - | - | IP55 | - | 3×1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Valeo 35/60 (2 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.14 | - | 63 | 36* | 50 | - | II | - | Exhaust | - | 25 | +50 | - | - | - | - | - | - | - | 220-240 | - | - | 18 | - | - | - | - | IP55 | - | 3×1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Decor 140x300s | - | - | wall mounting | rectangular flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | no regulator | 0.0128 | - | - | - | - | - | - | - | - | - | - |
Ceileo 200 T (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 20 | 130 | 24* | 50 | 714 | min | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | 36 | 0.55 | 5.3 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 200 T (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 29 | 210 | 27* | 50 | 1026 | max | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | 58 | 0.50 | 5.3 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 200 T (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.11 | 21 | 130 | 24* | 60 | 588 | min | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | 36 | 0.58 | 5.3 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 200 T (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.15 | 34 | 225 | 28* | 60 | 936 | max | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | 63 | 0.54 | 5.3 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Aero Still Vintage 100 | 220-240 | Vintage | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | 5.5 | 84 | 25 | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 23 | 0.24 | - | - | - | - | - | - | - | - |
Turbo 100 min | 230 | - | Inline | mixed-flow | 100 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.10 | - | 170 | - | 50/60 | 1980 | - | - | Exhaust, Supply | 1.68 | 23 | 60 | C | IPX4 | 1 | 27 | - | - | - | - | - | - | 47 | - | - | - | - | IP44 | - | - | - | - |
Turbo 100 max | 230 | - | Inline | mixed-flow | 100 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.11 | - | 220 | - | 50/60 | 2545 | - | - | Exhaust, Supply | 1.68 | 25 | 60 | C | IPX4 | 1 | 32 | - | - | - | - | - | - | 61 | - | - | - | - | IP44 | - | - | - | - |
BlauPlast RR 150/0.35 | - | - | - | - | 150 | - | - | - | - | - | - | - | round | 350 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 155x155HK | - | - | wall mounting, outdoor mounting | no flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | 0.008 | - | - | - | - | - | - | - | - | - | - |
Ducto Plus 150 min | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.087 | 19 | 250 | 36* | 50 | 1950 | min | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | 69 | 0.27 | 1.3 | - | - | - | - | - | - | - |
Ducto Plus 150 max | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.095 | 22 | 340 | 39* | 50 | 2250 | max | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | 94 | 0.23 | 1.3 | - | - | - | - | - | - | - |
Hi-Fi One 100 | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.05 | 8 | 85 | 26 | 50 | 2100 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 24 | 0.34 | 0.51 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Hi-Tech 100 (127-220V/60Hz) | 127 | Hi-Tech | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.115 | 10 | 82 | 33* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 23 | 0.44 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Hi-Tech 100 (127-220V/60Hz) | 220 | Hi-Tech | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.054 | 9 | 82 | 33* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 23 | 0.40 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Extero 100 50 Hz |
230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | 0.31 | - | 325 | - | 50 | 2530 | - | - | Exhaust | - | 71 | +55 | C | IPX4 | 1 | 54 | - | - | - | - | - | - | 90 | - | 4.1 | 2018 | - | IP44 | - | - | - | - |
Extero 100 60 Hz |
230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | 0.40 | - | 350 | - | 60 | 2625 | - | - | Exhaust | - | 92 | +55 | C | IPX4 | 1 | 54 | - | - | - | - | - | - | 97 | - | 4.1 | 2018 | - | IP44 | - | - | - | - |
BlauFlex AF M0/102/3 | - | - | - | - | 102 | - | - | - | - | - | - | - | - | 3000 | - | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RRT 100 | - | - | - | - | - | for round air ducts | - | - | - | - | - | - | round | 173 | plastic | T-joint | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Bravo Chrome 150 (127-220V/60Hz) | 127 | Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.175 | 25 | 266 | 38* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 74 | 0.34 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Bravo Chrome 150 (127-220V/60Hz) | 220 | Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.338 | 25 | 266 | 38* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 74 | 0.34 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Centro-MZ 315 L 50 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 315 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.66 | - | 1330 | - | 50 | 2680 | - | - | Supply and exhaust | 6.57 | 151 | - | - | IPX4 | 1 | 52 | - | -25...+50 | - | - | - | - | 369 | - | - | 2018 | - | IP44 | - | - | - | - |
Centro-MZ 315 L 60 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 315 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.89 | - | 1370 | - | 60 | 2750 | - | - | Supply and exhaust | 6.57 | 205 | - | - | IPX4 | 1 | 52 | - | -25...+50 | - | - | - | - | 381 | - | - | 2018 | - | IP44 | - | - | - | - |
BlauPlast RB 125/90° | - | - | - | - | 125 | for round air ducts | - | 164 | - | - | - | - | round | - | plastic | bend 90 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RR 200/1 | - | - | - | - | 200 | - | - | - | - | - | - | - | round | 1000 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 185x185H | - | - | wall mounting, outdoor mounting | no flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | 0.012 | - | - | - | - | - | - | - | - | - | - |
Ducto 100 | 220-240 | White | Inline | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.049 | 7.5 | 110 | 25* | 50 | 2100 | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | 31 | 0.25 | 0.61 | - | - | - | - | - | - | - |
BlauPlast RVC 100 | - | - | - | - | 100 | for round air ducts | - | - | - | - | - | - | round | 136 | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Quatro 125 (127-220V/60Hz) | 127 | White | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.119 | 16 | 170 | 35* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.34 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro 125 (127-220V/60Hz) | 220 | White | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.102 | 15 | 170 | 35* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.32 | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |