Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Form | Length | Material | Device | Current | Power | Maximum air flow | Sound pressure level | Air capacity factory settings | Control range | Frequency | RPM | Mode | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Transported air temperature | Sectional size | Thickness | Max. power | Maximum ambient temperature | Rated current | Voltage | Regulator | Air pass | Number of speeds | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Motor IP rating | Control range | LED-light power | Overall dimensions AxBxC | Cable cross section | * | *** |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tubo 125 | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 16 | 195 | 39* | - | - | 50 | 2400 | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 54 | 0.3 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
BlauPlast RR 150/2.5 | - | - | - | - | 150 | - | - | - | - | - | - | - | round | 2500 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 155x155/100HK | - | - | wall mounting, outdoor mounting | round flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.008 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ducto Plus 125 min | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.065 | 10 | 155 | 29* | - | - | 50 | 1950 | - | min | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 43 | 0.23 | 0.75 | - | - | - | - | - | - | - | - | - |
Ducto Plus 125 max | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.085 | 13 | 215 | 33* | - | - | 50 | 2250 | - | max | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 60 | 0.22 | 0.75 | - | - | - | - | - | - | - | - | - |
Trio One 100 | - | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.05 | 8 | 95 | 27 | - | - | 50 | - | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | 26 | 0.3 | 0.45 | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Platinum 125 (127-220V/60Hz) | 127 | Platinum | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.119 | 16 | 170 | 35* | - | - | 60 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.34 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Platinum 125 (127-220V/60Hz) | 220 | Platinum | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.102 | 15 | 170 | 35* | - | - | 60 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.32 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-D 125 (50 Hz) | 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.26 | - | - | - | - | - | 50 | 2500 | - | - | 310 | Exhaust | 3.2 | 61 | 25 +50 | C | IPX4 | 1 | 48 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-D 125 (60 Hz) | 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.36 | - | - | - | - | - | 60 | 2740 | - | - | 320 | Exhaust | 3.2 | 81 | 25 +50 | C | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauFlex AF M0/102/10 | - | - | - | - | 102 | - | - | - | - | - | - | - | - | 10000 | - | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RRT 150 | - | - | - | - | - | for round air ducts | - | - | - | - | - | - | round | 223 | plastic | T-joint | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Bravo Chrome 100 (127-220V/60Hz) | 127 | Chrome | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.115 | 10 | 91 | 33* | - | - | 60 | 2500 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 | 0.4 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Bravo Chrome 100 (127-220V/60Hz) | 220 | Chrome | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.054 | 9 | 91 | 33* | - | - | 60 | 2500 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 | 0.36 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Centro-MZ 250 L 50 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 250 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.59 | - | 980 | - | - | - | 50 | 2785 | - | - | - | Exhaust, Supply | 5.25 | 134 | - | B | IPX4 | 1 | 51 | -25...+50 | - | - | - | - | - | - | - | - | - | 272 | - | - | 2018 | - | IP44 | - | - | - | - | - | - |
Centro-MZ 250 L 60 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 250 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.77 | - | 1030 | - | - | - | 60 | 2880 | - | - | - | Supply and exhaust | 5.25 | 175 | - | B | IPX4 | 1 | 51 | -25...+50 | - | - | - | - | - | - | - | - | - | 286 | - | - | 2018 | - | IP44 | - | - | - | - | - | - |
BlauPlast RB 200/90° | - | - | - | - | 200 | for round air ducts | - | 241 | - | - | - | - | round | - | plastic | bend 90 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo 200 (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 20 | 130 | 24* | - | - | 50 | 714 | - | min | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | 36 | 0.55 | 5.3 | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 200 (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 29 | 210 | 27* | - | - | 50 | 1026 | - | max | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | 58 | 0.50 | 5.3 | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 200 (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.11 | 21 | 130 | 24* | - | - | 60 | 588 | - | min | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | 36 | 0.58 | 5.3 | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 200 (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.15 | 34 | 225 | 28* | - | - | 60 | 936 | - | max | - | Exhaust | - | - | - | - | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | 63 | 0.54 | 5.3 | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Still Gold 125 | 220-240 | Gold | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.059 | 9.4 | 158 | 31* | - | - | 50 | - | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 44 | 0.21 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Smart 100 24 hours | 100-240 | - | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | - | 33 | 17 | 33 | 0 | 50/60 | - | 24 hours | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 9 | - | - | - | - | - | - | - | - | - | - | - |
Smart 100 Quiet | 100-240 | - | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | - | 72 | 22 | 72 | 33 - 72 | 50/60 | - | Quiet | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 | - | - | - | - | - | - | - | - | - | - | - |
Smart 100 Maximal | 100-240 | - | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | - | - | 106 | 31 | 82 | 72 - 106 | 50/60 | - | Max | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 29 | - | - | - | - | - | - | - | - | - | - | - |
Smart 125 24 hours | 100-240 | - | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | 40 | 17 | 40 | 0 | 50/60 | - | 24 hours | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 11 | - | - | - | - | - | - | - | - | - | - | - |
Smart 125 Quiet | 100-240 | - | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | 83 | 21 | 83 | 40 - 83 | 50/60 | - | Quiet | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 23 | - | - | - | - | - | - | - | - | - | - | - |
Smart 125 Maximal | 100-240 | - | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | 133 | 32 | 97 | 83 - 133 | 50/60 | - | Max | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 37 | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RSVN 125 | - | - | - | - | 125 | for round air ducts | - | - | - | - | - | - | round | 77 | PVC (plastic) | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Quatro Hi-Tech Gold 150 | 220-240 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 24 | 265 | 37* | - | - | 50 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 74 | 0.33 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-R 100/100x6 V3(1 speed) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.32 | - | - | - | - | - | 50 | 1400 | - | - | 97 | Exhaust, Supply | 3.5 | 20 | 50 | C | IPX4 | - | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 27 | - | - | - | - | - | - | - |
Box-R 100/100x6 V3(2 speed) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.34 | - | - | - | - | - | 50 | 1800 | - | - | 138 | Exhaust, Supply | 3.5 | 26 | 50 | C | IPX4 | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 38 | - | - | - | - | - | - | - |
Box-R 100/100x6 V3(3 speed) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.4 | - | - | - | - | - | 50 | 2600 | - | - | 176 | Exhaust, Supply | 3.5 | 45 | 50 | C | IPX4 | - | 44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 49 | - | - | - | - | - | - | - |
BlauFlex АF M0/152/1 | - | - | - | - | 152 | - | - | - | - | - | - | - | - | 1000 | - | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RS 120/125 | - | - | - | - | - | for round air ducts | - | - | - | - | - | - | round | 42 | plastic | reducer | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Bravo Platinum 125 | 220-240 | Platinum | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 16 | 192 | 37* | - | - | 50 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 53 | 0.3 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Centro-MZ 100 50 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 100 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.28 | - | 250 | - | - | - | 50 | 2812 | - | - | - | Exhaust, Supply | 2.8 | 62 | - | C | IPX4 | 1 | 46 | -25...+55 | - | - | - | - | - | - | - | - | - | 69 | - | - | 2018 | - | IP44 | - | - | - | - | - | - |
Centro-MZ 100 60 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 100 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.34 | - | 265 | - | - | - | 60 | 3294 | - | - | - | Supply and exhaust | 2.8 | 77 | - | C | IPX4 | 1 | 47 | -25...+50 | - | - | - | - | - | - | - | - | - | 74 | - | - | 2018 | - | IP44 | - | - | - | - | - | - |
BlauPlast RV 100 | - | - | - | - | 100 | for round air ducts | - | - | - | - | - | - | round | 62 | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Altero 150 | 230 | - | Inline, flush mounting | mixed-flow | 150 | for round air ducts | - | - | - | no | no | no | - | - | - | - | 0.15 | - | 320 | - | - | - | 50/60 | 2300 | - | - | - | Supply and exhaust | - | 34 | +60 | B | IPX4 | 1 | 34 | - | - | - | - | - | - | - | - | - | - | 89 | - | - | - | - | - | - | - | - | - | - | - |
Aero Still 150 | 220-240 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.14 | 19 | 254 | 33* | - | - | 50 | - | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 71 | 0.27 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Wind-K 125 | 220-240 | White | Window mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 22 | 185 | 35* | - | - | 50 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 51 | 0.43 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
BlauPlast RR 200/2 | - | - | - | - | 200 | - | - | - | - | - | - | - | round | 2000 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 185x185/125H | - | - | wall mounting, outdoor mounting | round flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.012 | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RH 125 | - | - | - | - | 125 | for round air ducts | - | 138 | - | - | - | - | round | - | plastic | holder | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RB 125/45° | - | - | - | - | 125 | for round air ducts | - | - | - | - | - | - | round | - | plastic | bend 45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Bravo 150 | 220-240 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 24 | 305 | 39* | - | - | 50 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 85 | 0.28 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Centro-MZ 100 L 50 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 100 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.19 | - | 230 | - | - | - | 50 | 2732 | - | - | - | Exhaust, Supply | 2.5 | 42 | - | C | IPX4 | 1 | 35 | -25...+55 | - | - | - | - | - | - | - | - | - | 64 | - | - | 2018 | - | IP44 | - | - | - | - | - | - |
Centro-MZ 100 L 60 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 100 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.23 | - | 250 | - | - | - | 60 | 3258 | - | - | - | Exhaust, Supply | 2.5 | 51 | - | C | IPX4 | 1 | 36 | -25...+50 | - | - | - | - | - | - | - | - | - | 69 | - | - | 2018 | - | IP44 | - | - | - | - | - | - |
BlauPlast RTR 100/0.5-1 | - | - | - | - | 100 | - | - | - | - | - | - | - | round | 500-1000 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Smart IR Wi-Fi 100 (24 hours) | 100-240 | - | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.02 | - | 33 | 17* | - | 0 | 50/60 | - | 24 hours | - | - | Exhaust | - | 1.6 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 9 | - | - | - | - | - | 0 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Smart IR Wi-Fi 125 (24 hours) | 100-240 | - | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.03 | - | 40 | 17* | - | 0 | 50/60 | - | 24 hours | - | - | Exhaust | - | 1.7 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 11 | - | - | - | - | - | 0 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Smart IR Wi-Fi 100 (Silent) | 100-240 | - | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.04 | - | 72 | 21* | - | 33 - 106 | 50/60 | - | Silent | - | - | Exhaust | - | 2.9 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 | - | - | - | - | - | 9 - 29 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Smart IR Wi-Fi 125 (Silent) | 100-240 | - | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.04 | - | 83 | 22* | - | 40 - 133 | 50/60 | - | Silent | - | - | Exhaust | - | 3 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 23 | - | - | - | - | - | 11 - 37 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Smart IR Wi-Fi 100 (Max) | 100-240 | - | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.06 | - | 106 | 31* | - | 33 - 106 | 50/60 | - | Max | - | - | Exhaust | - | 5.6 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 29 | - | - | - | - | - | 9 - 29 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Smart IR Wi-Fi 125 (Max) | 100-240 | - | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.07 | - | 133 | 32* | - | 40 - 133 | 50/60 | - | Max | - | - | Exhaust | - | 6 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 37 | - | - | - | - | - | 11 - 37 | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Chrome 150 (127-220V/60Hz) | 127 | Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.175 | 25 | 270 | 39* | - | - | 60 | 2350 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 75 | 0.33 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Chrome 150 (127-220V/60Hz) | 220 | Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.338 | 25 | 270 | 39* | - | - | 60 | 2350 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 75 | 0.33 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Glory 150 | 220-240 | - | wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 24 | 258 | 37 | - | - | 50 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 72 | 0.33 | - | - | - | - | - | - | - | - | - | - |
CDP-2/5 | 230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 50 | - | - | - | - | - | - | - | - | - | IP40 | 1 | - | - | - | - | - | +40 | 3.0 | - | - | - | 2 | - | - | - | - | - | - | - | - | 88 x 88 x 51 | - | - | - |
Decor 140x140/100s | - | - | wall mounting | round flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | no regulator | 0.0043 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo Compact DC 110 Light | 120-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.18 | 19 | 187 | 23-25* | - | - | 50/60 | 1100 | - | - | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | 52 | 0.37 | 6.4 | - | - | - | - | 2 х 10 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Quatro Hi-Tech Chrome 100 | 220-240 | Hi-Tech Chrome | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.085 | 14 | 88 | 33* | - | - | 50 | 2300 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 24 | 0.57 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-R 100/80x5 V3(1 speed) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.32 | - | - | - | - | - | 50 | 1400 | - | - | 97 | Exhaust, Supply | 3.7 | 20 | 50 | C | IPX4 | - | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 27 | - | - | - | - | - | - | - |
Box-R 100/80x5 V3(2 speed) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.34 | - | - | - | - | - | 50 | 1800 | - | - | 138 | Exhaust, Supply | 3.7 | 26 | 50 | C | IPX4 | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 38 | - | - | - | - | - | - | - |
Box-R 100/80x5 V3(3 speed) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.4 | - | - | - | - | - | 50 | 2600 | - | - | 176 | Exhaust, Supply | 3.7 | 45 | 50 | C | IPX4 | - | 44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 49 | - | - | - | - | - | - | - |
BlauPlast RR 100/0.5 | - | - | - | - | 100 | - | - | - | - | - | - | - | round | 500 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Sileo 150 min | 220-240 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.08 | 17 | 220 | 28* | - | - | 50 | - | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 61 | 0.27 | - | - | - | - | - | - | - | - | - | - |
Sileo 150 max | 220-240 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.09 | 19 | 315 | 33* | - | - | 50 | - | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 88 | 0.22 | - | - | - | - | - | - | - | - | - | - |
Aero Gold 100 (127-220V/60Hz) | 127 | Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.115 | 10 | 92 | 34* | - | - | 60 | 2500 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 26 | 0.39 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Aero Gold 100 (127-220V/60Hz) | 220 | Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.054 | 9 | 92 | 34* | - | - | 60 | 2500 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 26 | 0.35 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ice 100 | 220-240 | - | wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.085 | 14 | 105 | 37 | - | - | 50 | 2300 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 29 | 0.48 | - | - | - | - | - | - | - | - | - | - |
Valeo-E 35/60 (2 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | - | - | - | - | - | 0.14 | - | 63 | 36* | - | - | 50 | - | - | II | - | Exhaust | - | 25 | +50 | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | 18 | - | - | - | - | IP55 | - | - | - | 3×1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Valeo-E 35/60 (1 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | - | - | - | - | - | 0.12 | - | 35 | 27* | - | - | 50 | - | - | I | - | Exhaust | - | 15 | +50 | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | 10 | - | - | - | - | IP55 | - | - | - | 3×1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Decor 180x180s | - | - | wall mounting | rectangular flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | no regulator | 0.0091 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo Compact 200 Light T (50 Hz, min) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 20 | 130 | 24* | - | - | 50 | 714 | - | min | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | 36 | 0.55 | 6.4 | - | - | - | - | 2 х 10 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo Compact 200 Light T (50 Hz, max) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 29 | 210 | 27* | - | - | 50 | 1026 | - | max | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | 58 | 0.50 | 6.4 | - | - | - | - | 2 х 10 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo Compact 200 Light T (60 Hz, min) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.11 | 21 | 130 | 24* | - | - | 60 | 588 | - | min | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | 36 | 0.58 | 6.4 | - | - | - | - | 2 х 10 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo Compact 200 Light T (60 Hz, max) |
220-240 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.15 | 34 | 225 | 28* | - | - | 60 | 936 | - | max | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | 63 | 0.54 | 6.4 | - | - | - | - | 2 х 10 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Quatro Platinum 125 | 220-240 | Platinum | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 16 | 167 | 34* | - | - | 50 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 46 | 0.34 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-R 80/80x5 V3(1 speed) | 230 | - | Inline | centrifugal | 80 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.32 | - | - | - | - | - | 50 | 1400 | - | - | 88 | Exhaust, Supply | 3.5 | 20 | 50 | C | IPX4 | - | 32 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 24 | - | - | - | - | - | - | - |
Box-R 80/80x5 V3(2 speed) | 230 | - | Inline | centrifugal | 80 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.34 | - | - | - | - | - | 50 | 1800 | - | - | 130 | Exhaust, Supply | 3.5 | 26 | 50 | C | IPX4 | - | 35 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 36 | - | - | - | - | - | - | - |
Box-R 80/80x5 V3(3 speed) | 230 | - | Inline | centrifugal | 80 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.4 | - | - | - | - | - | 50 | 2600 | - | - | 162 | Exhaust, Supply | 3.5 | 45 | 50 | C | IPX4 | - | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 45 | - | - | - | - | - | - | - |