Mode VoltageMountingDesignConnection diameterAir ductCasing materialEC motorOutdoor mountingSound-insulated casingFormLengthMaterialDeviceCurrentMaximum air flowFrequencyRPMSpeedHeat recovery efficiencyMaximum air capacityTypeWeight PowerMax. operating temperatureSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeCable cross sectionHeat exchanger materialElectric heater powerTransported air temperature CurrentConnected air duct diameterAir flow in heat recovery modeTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140Number of water coil rowsHumidity recovery efficiencyInsulationHeat recovery efficiencyOperating temperature rangeVoltageMaximum air flowSFPWeightErPExtract filterSupply filterAir duct wireAir speedMaximum operating pressureAir flow in heat recovery modeMotor IP ratingMax. power without electric heaterMax. unit current without electric heaterMax. unit currentMax. unit power with electric heaterMax. unit current with electric heaterCurrentMaximum power consumption in "Heat Recovery"Maximum power consumption in "Heat Recovery + Heat Pump"Maximum power consumption in "Heat Recovery"Air-handling unit energy efficiency "Heating" mode (COP)Air-handling unit energy efficiency "Cooling" mode (ERR)CoolantCoolant weightHeat output in "Heating" mode [kW] at t0 = +7 °C; tk = +45 °C*Heat output in "Cooling" mode [kW] at t0 = +7 °C; tk = +45 °C*Compressor typeTemperature setting range in "Cooling/Heating"Heat output in "Cooling" mode [W] at t0 = +7 °C; tk = +45 °CSound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Remote control panelFunctionsMotor max. powerSpigot
Axis-F 500 4D
50 Hz
400 Inline axial 500 for round air ducts polymer-coated steel no no no - - - - - 6570 50 1300 - - - Exhaust, Supply - 450 - - IPX4 3 60 - - - - - - - - -30...+60 - - - - - - - 1825 - 11.0 - - - - - - - IP24 - - - - - 0.9 - - - - - - - - - - - - - - - - - - - -
Axis-F 500 4D
60 Hz
400 Inline axial 500 for round air ducts polymer-coated steel no no no - - - - - 6230 60 1605 - - - Exhaust, Supply - 370 - - IPX4 3 60 - - - - - - - - -30...+50 - - - - - - - 1731 - 11.0 - - - - - - - IP24 - - - - - 0.7 - - - - - - - - - - - - - - - - - - - -
Blaubox EC ME 1000-6 S31 400 ceiling mounting, wall mounting, floor mounting centrifugal - for rectangular air ducts aluzinc yes no - - - - - - 1000 50 - - - - Supply - - - - - 3 45 - - - 6000 -30…+40 - 400 x 200 - - - - - 30 mm mineral wool - - - - - 30 2018 - - - - - - - 165 1.3 - 6165 11 - - - - - - - - - - - - - - - Coarce 90% / G4 (option: ePM1 70% / F7) - - - - -
BlauFlex Iso N 162/7.6 - - - 162 for round air ducts - - - - round 7600 - air duct - - - - - - - - - - - - - - - - - - - - - - - - - - - 25 mm mineral wool - -30...+120 - - - - - - - - 30 3000 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tower-V 190 2E (50 Hz) 230 for roof centrifugal - for round air ducts polymer-coated steel no yes no - - - - 0.30 610 50 2680 - - - Exhaust 7 69 -25…+50 C IPX4 1 48 - - - - - - - - - - - - - - - - 169 - - 2018 - - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -
Tower-V 190 2E (60 Hz) 230 for roof centrifugal - for round air ducts polymer-coated steel no yes no - - - - 0.40 654 60 2980 - - - Exhaust 7 89 -25…+50 IPX4 1 49 - - - - - - - - - - - - - - - - 182 - - - - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -
Сentro-M 160 (60 Hz) 220-240 Inline centrifugal 160 for round air ducts polymer-coated steel no no no - - - - 0.61 575 60 3160 - - - Exhaust, Supply - 137 - IPX4 1 47 - - - - - - - - -25...+45 - - - - - - - 160 - 5.0 - - - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -
Сentro-M 160 (50 Hz) 220-240 Inline centrifugal 160 for round air ducts polymer-coated steel no no no - - - - 0.44 567 50 2770 - - - Exhaust, Supply - 99 - C IPX4 1 45 - - - - - - - - -25…+45 - - - - - - - 158 - 5.0 2018 - - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC LHP 400 S17 230 - - - - aluzinc - - - - - - - - 520 50 - - - - - - - - - - 1 45 rotary - aluminum - - - 160 - -10…+40 - - - - 85 - - 53 - 150 - G4 G4 (Option: F7) - - - - - - - 4.6 - - - - 0.745 0.31 6 4 R410A 0.8 1.56 - Sealed, rotary type +16...+30 1.2 - - - - - - - -
Valeo-BF 35/100
(2 speed)
220-240 ceiling mounting, wall mounting centrifugal - for round air ducts plastic no no no - - - - 0.18 102 50 - II - - Exhaust - 44 +50 - IP55 - 46 - 3х1.5 - - - - - - - - - - - - - - 28 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Valeo-BF 35/100
(1 speed)
220-240 ceiling mounting, wall mounting centrifugal - for round air ducts plastic no no no - - - - 0.12 35 50 - I - - Exhaust - 15 +50 - IP55 - 27 - 3x1.5 - - - - - - - - - - - - - - 10 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Box EC 80x50-3 400 Inline centrifugal - for rectangular air ducts galvanized steel yes no - - - - - - 8395 50/60 1470 - - - Exhaust, Supply 62.3 2025 - IPX4 3 60 - - - - - - - - -25...+50 - - - - - - - 2332 - - 2018 - - - - - - IP54 - - - - - 2.01 - - - - - - - - - - - - - - - - - - - -
Vento Ergo A85 S10 Pro1
(1 speed)
- - - - 150 - - - - - - - - 0.034 36 50/60 1000 I - - - - 4.74 - - IP24 1 - - - - - - - - 18 -20...+40 40 - - - - - 100-230 10 0.95 - - - - - - - 5 - - - - - - - - - - - - - - - - - - - 29 19 G3 (Option: F8 PM2,5 > 99 %*) - - Filter replacement indication, Timer, Humidity sensor - -
Vento Ergo A85 S10 Pro1
(2 speed)
- - - - 150 - - - - - - - - 0.050 59 50/60 1500 II - - - - 6.56 - - IP24 1 - - - - - - - - 30 -20...+40 40 - - - - - 100-230 16 0.80 - - - - - - - 8 - - - - - - - - - - - - - - - - - - - 35 25 G3 (Option: F8 PM2,5 > 99 %*) - - Filter replacement indication, Timer, Humidity sensor - -
Vento Ergo A85 S10 Pro1
(3 speed)
- - - - 150 - - - - - - - - 0.071 85 50/60 2045 III - - - - 9.65 - - IP24 1 - - - - - - - - 43 -20...+40 40 - - - - - 100-230 24 0.82 - - - - - - - 12 - - - - - - - - - - - - - - - - - - - 44 34 G3 (Option: F8 PM2,5 > 99 %*) - - Filter replacement indication, Timer, Humidity sensor - -
KOMFORT Roto EC LE 1200-6 S17 400 - - - - aluzinc - - - - - - - - 1200 50/60 1930 - - - - - - - - - 3 60 rotary - aluminum 6000 - - 315 - -25...+40 - - - 20 mm mineral wool 73–95 - - 333 - 165 2016, 2018 G4 G4 - - - - - - - - 6570 9.5 - - - - - - - - - - - - - - - - - - - 2 items x 208 -
Iso-ZS 315 6E max 230 - centrifugal - for round air ducts galvanized steel no no yes - - - - 4.59 - 50 960 - - 3470 Exhaust, Supply 45.0 800 -20…+50 - IPX4 1 43 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
inWave EC 100/125 max (100 spigot) 230 Inline mixed-flow - for round air ducts plastic yes no yes - - - - - 295 50/60 3168 - - - Exhaust, Supply 5.0 39 –25…+55 - IPX4 1 31 - - - - - - - - - - - - - - - - 82 - - 2018 - - - - - - IP44 - - - - - 0.36 - - - - - - - - - - - - - - - - - - - 100
KOMFORT ERV EC DB 350 S14 230 ceiling mounting, flush mounting - - for round air ducts - yes no yes - - - - - 430 50/60 3200 - - - Supply and exhaust - 171 - A - 1 46 cross-flow - enthalpy - - 1.3 150 - -25...+40 - - 19...34 - 68...85 - - 119 - 42 2016, 2018 G4 G4 + F8 (PM2.5 > 87 %) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tower-H 500 4D 400 for roof centrifugal - for round air ducts polymer-coated steel no yes no - - - - 2.64 8435 50 1460 - - - Exhaust 46.6 1527 -30…+50 - IPX4 3 62 - - - - - - - - - - - - - - - - 2343 - - 2018 - - - - - - IP54 - - - - - - - - - - - - - - - - - - - - - - - - - -
Tower-HC 250 2E (50 Hz) 230 for roof centrifugal - for round air ducts polymer-coated steel no yes no - - - - 0.81 1485 50 2480 - - - Exhaust - 184 -25…+50 IPX4 1 54 - - - - - - - - - - - - - - - - 413 - 8 2018 - - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -
Tower-HC 250 2E (60 Hz) 230 for roof centrifugal - for round air ducts polymer-coated steel no yes no - - - - 0.90 1350 60 2320 - - - Exhaust - 232 -25…+50 IPX4 1 53 - - - - - - - - - - - - - - - - 375 - 8 - - - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -
Iso-RB 355 230 Inline centrifugal 355 for round air ducts aluzinc no no yes - - - - 0.89 2235 50 1330 - - - Exhaust, Supply - 202 - - IPX4 1 48 - - - - - - - - -25...+55 - - - - - - - 621 - 58 2018 - - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -
S-Vent 180х74-0.55-4D 400 floor mounting centrifugal - for rectangular air ducts, for round air ducts polymer-coated steel no yes no - - - - 1.6 1030 50 1360 - - - Exhaust, Supply 13.5 550 +60 D IP54 3 64 - - - - - - - - - - - - - - - - 286 - - 2018 - - - - - - IP54 - - - - - - - - - - - - - - - - - - - - - - - - - -
Box-D 150 (50 Hz) 230 Inline centrifugal 150 for round air ducts galvanized steel no no no - - - - 0.5 - 50 2465 - - 485 Exhaust 6.5 112 -25 +50 - IPX4 1 52 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Box-D 150 (60 Hz) 230 Inline centrifugal 150 for round air ducts galvanized steel no no no - - - - 0.6 - 60 2550 - - 531 Exhaust 6.5 136 -25 +50 - IPX4 1 53 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT ERV D 450 S3 230 ceiling mounting, flush mounting - - - polymer-coated steel no - - - - - - - 500 50 2870 - - - - - 354 - E - 1 57 cross-flow - enthalpy - - - 150 - -5...+40 - - 23...40 5-10 mm, expanded polyurethane 71...87 - - 139 - 39 - G4 G4 + F8 (PM2.5 > 93 %) - - - - - - - - - - 1.54 - - - - - - - - - - - - - - - - - - - -
KOMFORT LW 1700-4 230 ceiling mounting, wall mounting, floor mounting - - - aluzinc - - - - - - - - 1700 50 1100 - 77 - - - 980 - - - 1 49 cross-flow - polystyrene - - 4.3 315 - -25...+40 - 4 - 50 mm mineral wool - - - 472 - 99 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Iso-B 160 230 Inline centrifugal - for round air ducts galvanized steel no no yes - - - - 0.33 - 50 2690 - - 420 Exhaust, Supply 6.4 75 -25 +55 C IPX4 - 36 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Box-I 50x30 4E
50 Hz
230 Inline centrifugal - for rectangular air ducts galvanized steel - - - - - - - 0.57 1700 50 1390 - - - Exhaust, Supply 37.2 140 - - IPX4 1 48 - - - - - - - - -25…+45 - - - - - - - 472 - - 2018 - - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -
Box-I 50x30 4E
60 Hz
230 Inline centrifugal - for rectangular air ducts galvanized steel - - - - - - - 0.73 1855 60 1530 - - - Exhaust, Supply 37.2 175 - - IPX4 1 50 - - - - - - - - -25…+50 - - - - - - - 515 - - 2018 - - - - - - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -
SD 200/1200 - - - 200 for round air ducts galvanized steel - - - - 1200 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7.1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axis-QR 300 4Е
50 Hz
230 wall mounting axial 300 for round air ducts polymer-coated steel no no no - - - - - 1340 50 1350 - - - Exhaust, Supply - 75 - - IPX4 1 44 - - - - - - - - -30...+60 - - - - - - - 372 - 5.0 - - - - - - - IP24 - - - - - 0.35 - - - - - - - - - - - - - - - - - - - -
Axis-QR 300 4Е
60 Hz
230 wall mounting axial 300 for round air ducts polymer-coated steel no no no - - - - - 1475 60 1405 - - - Exhaust, Supply - 92 - - IPX4 1 45 - - - - - - - - -30...+50 - - - - - - - 410 - 5.0 - - - - - - - IP24 - - - - - 0.4 - - - - - - - - - - - - - - - - - - - -
Axis-QR EC 200 max 230 wall mounting axial 210 for round air ducts polymer-coated steel yes no no - - - - - 1600 50/60 2900 - - - Supply and exhaust - 115 - - IPX5 1 54 - - - - - - - - –25…+60 - - - - - - - 444 - 1.7 - - - - - - - IP55 - - - - - 0.85 - - - - - - - - - - - - - - - - - - - -