Axis-Q EC 200 max |
230
|
wall mounting
|
axial
|
210
|
for round air ducts
|
polymer-coated steel
|
yes
|
no
|
no
|
-
|
-
|
1600
|
50/60
|
2900
|
-
|
-
|
Supply and exhaust
|
-
|
115
|
-
|
-
|
IPX5
|
1
|
54
|
-
|
-
|
–25…+60
|
-
|
-
|
444
|
2.04
|
-
|
-
|
-
|
-
|
IP55
|
-
|
-
|
0.85
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Tower-V EC 355 |
230
|
for roof
|
centrifugal
|
-
|
for round air ducts, for square air ducts
|
polymer-coated steel
|
yes
|
yes
|
no
|
-
|
9.36
|
3830
|
50/60
|
1550
|
-
|
-
|
Exhaust
|
-
|
669
|
-25...+50
|
–
|
IPX4
|
1
|
51
|
-
|
-
|
-
|
-
|
-
|
1064
|
23
|
2018
|
-
|
-
|
-
|
IP54
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
SD 160/900 |
-
|
-
|
-
|
160
|
for round air ducts
|
galvanized steel
|
-
|
-
|
-
|
900
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
4.6
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Clean Box 160 UV |
1 ~ 230
|
ceiling mounting, wall mounting, flush mounting
|
-
|
160
|
for round air ducts
|
polymer-coated steel
|
-
|
-
|
-
|
-
|
-
|
-
|
50/60
|
-
|
-
|
-
|
Supply
|
13.4
|
60
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0.8
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
HNS L 60 W 2G11
|
40
|
19
|
408 x 40
|
Iso-K 400 4E |
230
|
Inline
|
centrifugal
|
400
|
for round air ducts
|
galvanized steel
|
no
|
yes
|
yes
|
-
|
5.00
|
-
|
50
|
1440
|
-
|
5392
|
Exhaust
|
-
|
1048
|
-20…+120
|
-
|
IP54
|
1
|
54
|
-
|
-
|
-
|
-
|
-
|
-
|
92
|
-
|
1498
|
-
|
-
|
IP54
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Primo EC 355 max |
230
|
Inline
|
mixed-flow
|
355
|
for round air ducts
|
-
|
yes
|
no
|
no
|
-
|
-
|
4630
|
50
|
3175
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
IPX4
|
1
|
60
|
-
|
-
|
-25…+55
|
-
|
-
|
1286
|
-
|
2018
|
-
|
-
|
-
|
IP44
|
-
|
-
|
3.10
|
-
|
701
|
-
|
-
|
-
|
-
|
-
|
Tower-H EC 450 |
400
|
for roof
|
centrifugal
|
-
|
for round air ducts, for square air ducts
|
polymer-coated steel
|
yes
|
yes
|
no
|
-
|
3.27
|
8110
|
50/60
|
1560
|
-
|
-
|
Exhaust
|
-
|
1323
|
-20...+60
|
–
|
IPX4
|
3
|
63
|
-
|
-
|
-
|
-
|
-
|
2253
|
46
|
2018
|
-
|
-
|
-
|
IP54
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
ALB-45 |
220-240
|
ceiling mounting, wall mounting
|
axial
|
-
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
no
|
-
|
-
|
3850
|
50
|
1360
|
-
|
-
|
Supply
|
-
|
255
|
-
|
-
|
IP44
|
-
|
58
|
F
|
1.12
|
-
|
-
|
-
|
1070
|
50
|
-
|
-
|
-
|
-
|
IP44
|
-
|
-
|
-
|
+100
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso Box-F 150 G4-H13-Carbon L V2 min |
230
|
ceiling mounting, wall mounting
|
centrifugal
|
150
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
yes
|
-
|
0.18
|
205
|
50
|
700
|
min
|
-
|
Supply
|
14.87
|
40
|
-
|
D
|
IPX4
|
1
|
15
|
-
|
-
|
-25…+40
|
-
|
-
|
57
|
-
|
2018
|
-
|
-
|
-
|
-
|
93
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso Box-F 150 G4-H13-Carbon L V2 max |
230
|
ceiling mounting, wall mounting
|
centrifugal
|
150
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
yes
|
-
|
0.21
|
285
|
50
|
1200
|
max
|
-
|
Supply
|
14.87
|
48
|
-
|
D
|
IPX4
|
1
|
25
|
-
|
-
|
-25…+40
|
-
|
-
|
79
|
-
|
2018
|
-
|
-
|
-
|
-
|
92
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso-Mix 250 min |
230
|
Inline
|
mixed-flow
|
-
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
yes
|
-
|
0.52
|
1035
|
50/60
|
1960
|
min
|
-
|
Exhaust, Supply
|
15
|
127
|
+60
|
–
|
IPX4
|
1
|
34
|
-
|
-
|
-
|
-
|
-
|
288
|
-
|
2018
|
-
|
-
|
-
|
IP44
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso-Mix 250 max |
230
|
Inline
|
mixed-flow
|
-
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
yes
|
-
|
0.79
|
1315
|
50/60
|
2460
|
max
|
-
|
Exhaust, Supply
|
15
|
178
|
+60
|
–
|
IPX4
|
1
|
38
|
-
|
-
|
-
|
-
|
-
|
365
|
-
|
2018
|
-
|
-
|
-
|
IP44
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
BlauAIR CFP 700 |
200-240
|
ceiling mounting, outdoor mounting
|
-
|
-
|
for rectangular air ducts
|
aluzinc
|
yes
|
yes
|
yes
|
-
|
-
|
700
|
50/60
|
4120
|
-
|
-
|
Supply and exhaust
|
-
|
2x169
|
-
|
-
|
IP34
|
1
|
33
|
B
|
-
|
-25...+40
|
-
|
-
|
-
|
85
|
-
|
-
|
ePM1 ≥ 50% (ISO 16890)
|
F7 (EN 779)
|
IP54
|
-
|
1.75
|
-
|
-
|
-
|
-35...+50
|
-
|
-
|
-
|
-
|
Tower-H 310 2E |
230
|
for roof
|
centrifugal
|
-
|
for round air ducts
|
polymer-coated steel
|
no
|
yes
|
no
|
-
|
1.42
|
2150
|
50
|
2620
|
-
|
-
|
Exhaust
|
13.2
|
324
|
-25…+50
|
-
|
IPX4
|
1
|
58
|
-
|
-
|
-
|
-
|
-
|
597
|
-
|
2018
|
-
|
-
|
-
|
IP44
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Tower-HC 220 2E A (50 Hz) |
230
|
for roof
|
centrifugal
|
-
|
for round air ducts
|
aluminium
|
no
|
yes
|
no
|
-
|
0.49
|
915
|
50
|
2640
|
-
|
-
|
Exhaust
|
-
|
108
|
-25…+50
|
–
|
IPX4
|
1
|
50
|
-
|
-
|
-
|
-
|
-
|
254
|
7
|
2018
|
-
|
-
|
-
|
IP44
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Tower-HC 220 2E A (60 Hz) |
230
|
for roof
|
centrifugal
|
-
|
for round air ducts
|
aluminium
|
no
|
yes
|
no
|
-
|
0.54
|
920
|
60
|
2840
|
-
|
-
|
Exhaust
|
-
|
118
|
-25…+50
|
–
|
IPX4
|
1
|
51
|
-
|
-
|
-
|
-
|
-
|
256
|
7
|
-
|
-
|
-
|
-
|
IP44
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
S-Vent 140х74-0.37-2D |
400
|
floor mounting
|
centrifugal
|
-
|
for rectangular air ducts, for round air ducts
|
polymer-coated steel
|
no
|
yes
|
no
|
-
|
0.9
|
710
|
50
|
2730
|
-
|
-
|
Exhaust, Supply
|
9.3
|
370
|
+60
|
D
|
IP54
|
3
|
65
|
-
|
-
|
-
|
-
|
-
|
197
|
-
|
2018
|
-
|
-
|
-
|
IP54
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso Box-F 100 G4 V2 min |
230
|
ceiling mounting, wall mounting
|
centrifugal
|
100
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
yes
|
-
|
0.15
|
160
|
50
|
700
|
min
|
-
|
Supply
|
13.95
|
34
|
-
|
D
|
IPX4
|
1
|
14
|
-
|
-
|
-25…+40
|
-
|
-
|
44
|
-
|
2018
|
-
|
-
|
-
|
-
|
35
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso Box-F 100 G4 V2 max |
230
|
ceiling mounting, wall mounting
|
centrifugal
|
100
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
yes
|
-
|
0.19
|
190
|
50
|
1200
|
max
|
-
|
Supply
|
13.95
|
42
|
-
|
D
|
IPX4
|
1
|
23
|
-
|
-
|
-25…+40
|
-
|
-
|
53
|
-
|
2018
|
-
|
-
|
-
|
-
|
31
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Сentro-M 250 L |
230
|
Inline
|
centrifugal
|
250
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
no
|
-
|
0.69
|
-
|
50
|
2315
|
-
|
1190
|
Exhaust, Supply
|
5.09
|
158
|
-25 +50
|
-
|
IPX4
|
-
|
52
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso-Mix EC 100 |
230
|
ceiling mounting, wall mounting, floor mounting
|
-
|
100
|
-
|
polymer-coated steel
|
yes
|
-
|
-
|
-
|
-
|
300
|
50
|
3680
|
-
|
-
|
-
|
-
|
30
|
-
|
B
|
IPX4
|
1
|
37
|
-
|
-
|
-25...+55
|
-
|
-
|
83
|
4.6
|
2018
|
-
|
-
|
-
|
-
|
-
|
-
|
0.29
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Clean Box 150 UV |
1 ~ 230
|
ceiling mounting, wall mounting, flush mounting
|
-
|
150
|
for round air ducts
|
polymer-coated steel
|
-
|
-
|
-
|
-
|
-
|
-
|
50/60
|
-
|
-
|
-
|
Supply
|
11.9
|
60
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0.8
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
HNS L 60 W 2G11
|
40
|
19
|
408 x 40
|
Iso-K 315 2D (50 Hz) |
400
|
Inline
|
centrifugal
|
315
|
for round air ducts
|
galvanized steel
|
no
|
yes
|
yes
|
-
|
2.80
|
-
|
50
|
3025
|
-
|
4710
|
Exhaust
|
-
|
1225
|
-20…+120
|
-
|
IP54
|
3
|
52
|
-
|
-
|
-
|
-
|
-
|
-
|
60
|
-
|
1308
|
-
|
-
|
IP54
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso-K 315 2D (60 Hz) |
400
|
Inline
|
centrifugal
|
315
|
for round air ducts
|
galvanized steel
|
no
|
yes
|
yes
|
-
|
3.40
|
-
|
60
|
3328
|
-
|
5290
|
Exhaust
|
-
|
2011
|
-20…+120
|
-
|
IP54
|
3
|
54
|
-
|
-
|
-
|
-
|
-
|
-
|
60
|
-
|
1470
|
-
|
-
|
IP54
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Primo EC 160 |
230
|
Inline
|
mixed-flow
|
160
|
for round air ducts
|
-
|
yes
|
no
|
no
|
-
|
-
|
700
|
50/60
|
3700
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
IPX4
|
1
|
39
|
-
|
-
|
-25...+55
|
-
|
-
|
194
|
-
|
2018
|
-
|
-
|
-
|
IP44
|
-
|
-
|
0.48
|
-
|
54
|
-
|
-
|
-
|
-
|
-
|
Tower-H EC 250 |
230
|
for roof
|
centrifugal
|
-
|
for round air ducts, for square air ducts
|
polymer-coated steel
|
yes
|
yes
|
no
|
-
|
1.29
|
1470
|
50/60
|
3300
|
-
|
-
|
Exhaust
|
-
|
161
|
-25...+60
|
–
|
IPX4
|
1
|
54
|
-
|
-
|
-
|
-
|
-
|
408
|
13
|
2018
|
-
|
-
|
-
|
IP55
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
S-Vent 500х229-5.5-8D |
400
|
floor mounting
|
centrifugal
|
-
|
for rectangular air ducts, for round air ducts
|
polymer-coated steel
|
no
|
yes
|
no
|
-
|
14.8
|
11550
|
50
|
700
|
-
|
-
|
Exhaust, Supply
|
85
|
5500
|
+60
|
-
|
IP54
|
3
|
72
|
-
|
-
|
-
|
-
|
-
|
3209
|
-
|
-
|
-
|
-
|
-
|
IP54
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso Box-F 150 G4-Carbon V2 min |
230
|
ceiling mounting, wall mounting
|
centrifugal
|
150
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
yes
|
-
|
0.41
|
320
|
50
|
700
|
min
|
-
|
Supply
|
17.08
|
92
|
-
|
D
|
IPX4
|
1
|
16
|
-
|
-
|
-25…+40
|
-
|
-
|
89
|
-
|
2018
|
-
|
-
|
-
|
-
|
47
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso Box-F 150 G4-Carbon V2 max |
230
|
ceiling mounting, wall mounting
|
centrifugal
|
150
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
yes
|
-
|
0.55
|
430
|
50
|
1200
|
max
|
-
|
Supply
|
17.08
|
117
|
-
|
D
|
IPX4
|
1
|
27
|
-
|
-
|
-25…+40
|
-
|
-
|
119
|
-
|
2018
|
-
|
-
|
-
|
-
|
41
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso-Mix 100 min |
230
|
Inline
|
mixed-flow
|
-
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
yes
|
-
|
0.10
|
175
|
50/60
|
2015
|
min
|
-
|
Exhaust, Supply
|
4.6
|
24
|
+60
|
-
|
IPX4
|
1
|
24
|
-
|
-
|
-
|
-
|
-
|
49
|
-
|
―
|
-
|
-
|
-
|
IP44
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Iso-Mix 100 max |
230
|
Inline
|
mixed-flow
|
-
|
for round air ducts
|
polymer-coated steel
|
no
|
no
|
yes
|
-
|
0.11
|
233
|
50/60
|
2610
|
max
|
-
|
Exhaust, Supply
|
4.6
|
26
|
+60
|
-
|
IPX4
|
1
|
29
|
-
|
-
|
-
|
-
|
-
|
65
|
-
|
―
|
-
|
-
|
-
|
IP44
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
BlauAIR RV 5000 |
380-480
|
floor mounting, outdoor mounting
|
-
|
-
|
for rectangular air ducts
|
aluzinc
|
yes
|
yes
|
yes
|
-
|
-
|
5000
|
50/60
|
1350
|
-
|
-
|
Supply and exhaust
|
-
|
2x1420
|
-
|
-
|
IP34
|
3
|
32
|
B
|
-
|
-25...+40
|
-
|
-
|
-
|
715
|
-
|
-
|
ePM1 ≥ 50% (ISO 16890)
|
F7 (EN 779)
|
IP54
|
-
|
4.53
|
-
|
-
|
-
|
-35...+50
|
-
|
-
|
-
|
-
|