Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Print version
Search results
Selected 1357 products
Mode SEC classWeightPhaseMaximum air flowSupply filterExtract filterMountingBypassTypeFrequencyHeat exchanger materialHeat exchanger typeHeat recovery efficiencyConnected air duct diameterInsulationCasing materialTransported air temperatureSound pressure level at 3 mVoltageMax. unit powerMax. unit currentNumber of water coil rowsMaximum air flowVoltagePowerCurrentSFPSound pressure levelDesignConnection diameterStyle*SpeedAir ductRemote control panelFunctionsAir flow in ventilation modeAir flow in ventilation modeAir flow in heat recovery modeAir flow in heat recovery modeOutdoor sound pressure attenuation in accordance with DIN EN 20140Indoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Sound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004Ingress protection ratingEC motorPowerRPMCurrentMotor IP ratingErPOutdoor mountingSound-insulated casingPower
KOMFORT EC DBW 900 R S21 A 112 1 1030 G4 (Option: F7) G4 ceiling mounting yes Supply and exhaust 50/60 polystyrene counter-flow 75...88 250 20 mm mineral wool aluzinc -25...+40 33 230 442 3 2 286 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 900-E L S21 A 112 1 1030 G4 (Option: F7) G4 ceiling mounting yes Supply and exhaust 50/60 enthalpy counter-flow 69...85 250 20 mm mineral wool aluzinc -25...+40 33 230 442 3 2 286 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 900-E R S21 A 112 1 1030 G4 (Option: F7) G4 ceiling mounting yes Supply and exhaust 50/60 enthalpy counter-flow 69...85 250 20 mm mineral wool aluzinc -25...+40 33 230 442 3 2 286 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 3000 S21 NRVU 268 3 4300 G4 G4 ceiling mounting yes Supply and exhaust 50/60 aluminum cross-flow 59...72 400 25 mm mineral wool aluzinc -25...+40 46 400 2226 3.5 2 1195 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 2000 S21 NRVU 140 1 2100 G4 G4 ceiling mounting yes Supply and exhaust 50/60 aluminum cross-flow 50...67 315 25 mm mineral wool aluzinc -25...+40 36 230 1063 4.7 2 583 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 550 L S21 A 68 1 608 G4 (Option: F7) G4 ceiling mounting yes Supply and exhaust 50/60 polystyrene counter-flow 78...90 200 20 mm mineral wool aluzinc -25...+40 30 230 322 2.4 2 169 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 550 R S21 A 68 1 608 G4 (Option: F7) G4 ceiling mounting yes Supply and exhaust 50/60 polystyrene counter-flow 78...90 200 20 mm mineral wool aluzinc -25...+40 30 230 322 2.4 2 169 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 550-E L S21 A 68 1 608 G4 (Option: F7) G4 ceiling mounting yes Supply and exhaust 50/60 enthalpy counter-flow 69...87 200 20 mm mineral wool aluzinc -25...+40 30 230 322 2.4 2 169 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 550-E R S21 A 68 1 608 G4 (Option: F7) G4 ceiling mounting yes Supply and exhaust 50/60 enthalpy counter-flow 69...87 200 20 mm mineral wool aluzinc -25...+40 30 230 322 2.4 2 169 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Trio 100 - 0.45 - 90 - - ceiling mounting, wall mounting - Exhaust 50 - - - - - - - - - - - - 25 220-240 8 0.05 0.32 29* axial 100 White Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - - - - - - - - - - - - - - - - - -
Trio 150 - 0.97 - 255 - - ceiling mounting, wall mounting - Exhaust 50 - - - - - - - - - - - - 71 220-240 28 0.21 0.39 35* axial 150 White Sound pressure level measured in free space at a distance of 3 meters from the fan - - - - - - - - - - - - - - - - - - - - - -
Trio V2 100 min - 0.55 - 54 - - ceiling mounting, wall mounting - Exhaust 50 - - - - - - - - - - - - 15 220-240 5 0.03 0.33 23* axial 100 White Sound pressure level measured in free space at a distance of 3 meters from the fan min - - - - - - - - - - - - - - - - - - - - -
Trio V2 100 max - 0.55 - 81 - - ceiling mounting, wall mounting - Exhaust 50 - - - - - - - - - - - - 23 220-240 8 0.05 0.36 28* axial 100 White Sound pressure level measured in free space at a distance of 3 meters from the fan max - - - - - - - - - - - - - - - - - - - - -
Trio V2 150 min - 0.97 - 210 - - ceiling mounting, wall mounting - Exhaust 50 - - - - - - - - - - - - 58 220-240 18 0.079 0.31 29* axial 150 White Sound pressure level measured in free space at a distance of 3 meters from the fan min - - - - - - - - - - - - - - - - - - - - -
Trio V2 150 max - 0.97 - 300 - - ceiling mounting, wall mounting - Exhaust 50 - - - - - - - - - - - - 83 220-240 21 0.085 0.25 35* axial 150 White Sound pressure level measured in free space at a distance of 3 meters from the fan max - - - - - - - - - - - - - - - - - - - - -
Vento Eco A30-4 S11 Pro
(1 Speed)
- - - - - - wall mounting - - 50/60 - - ≤81 - - - -20...+40 - 100-240 - - - - - - 0.021 0.74 - - - - - I 100 Sensor Filter replacement indication, Timer, External sensor connection 3 10 1 5 42 D1 30 21 IP24 yes 1.03 1600 - - - - - -
Vento Eco A30-4 S11 Pro
(2 Speed)
- - - - - - wall mounting - - 50/60 - - ≤81 - - - -20...+40 - 100-240 - - - - - - 0.027 0,71 - - - - - II 100 Sensor Filter replacement indication, Timer, External sensor connection 6 20 3 10 42 D1 37 28 IP24 yes 1.96 2200 - - - - - -
Vento Eco A30-4 S11 Pro
(3 Speed)
- - - - - - wall mounting - - 50/60 - - ≤81 - - - -20...+40 - 100-240 - - - - - - 0.038 0.83 - - - - - III 100 Sensor Filter replacement indication, Timer, External sensor connection 8 30 4 15 42 D1 40 31 IP24 yes 3.47 2500 - - - - - -
Vento Eco A30-4 S Pro
(1 Speed)
- - - - - - wall mounting - - 50/60 - - ≤81 - - - -20...+40 - 100-240 - - - - - - 0.021 0.74 - - - - - I 100 Sensor Filter replacement indication, Timer, External sensor connection 3 10 1 5 42 D1 30 21 IP24 yes 1.03 1600 - - - - - -
Vento Eco A30-4 S Pro
(2 Speed)
- - - - - - wall mounting - - 50/60 - - ≤81 - - - -20...+40 - 100-240 - - - - - - 0.027 0.71 - - - - - II 100 Sensor Filter replacement indication, Timer, External sensor connection 6 20 3 10 42 D1 37 28 IP24 yes 1.96 2200 - - - - - -
Vento Eco A30-4 S Pro
(3 Speed)
- - - - - - wall mounting - - 50/60 - - ≤81 - - - -20...+40 - 100-240 - - - - - - 0.038 0.83 - - - - - III 100 Sensor Filter replacement indication, Timer, External sensor connection 8 30 4 15 42 D1 40 31 IP24 yes 3.47 2500 - - - - - -
Primo 150 (min) - - 1 488 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 34 230 - - - 136 - - - - - mixed-flow 150 - - min for round air ducts - - - - - - - - - - IPX4 no - 2550 0.15 IP20 2018 no no 34
Primo 150 (mid) - - 1 544 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 35 230 - - - 151 - - - - - mixed-flow 150 - - med for round air ducts - - - - - - - - - - IPX4 no - 2704 0.16 IP20 2018 no no 37
Primo 150 (max) - - 1 600 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 37 230 - - - 167 - - - - - mixed-flow 150 - - max for round air ducts - - - - - - - - - - IPX4 no - 2816 0.20 IP20 2018 no no 45
Primo 160 (min) - - 1 488 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 34 230 - - - 136 - - - - - mixed-flow 160 - - min for round air ducts - - - - - - - - - - IPX4 no - 2550 0.15 IP20 2018 no no 34
Primo 160 (mid) - - 1 544 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 35 230 - - - 151 - - - - - mixed-flow 160 - - med for round air ducts - - - - - - - - - - IPX4 no - 2704 0.16 IP20 2018 no no 37
Primo 160 (max) - - 1 600 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 37 230 - - - 167 - - - - - mixed-flow 160 - - max for round air ducts - - - - - - - - - - IPX4 no - 2816 0.20 IP20 2018 no no 45
Primo 200 (min) - - 1 752 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 37 230 - - - 209 - - - - - mixed-flow 200 - - min for round air ducts - - - - - - - - - - IPX4 no - 1866 0.37 IP20 2018 no no 82
Primo 200 (mid) - - 1 978 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 40 230 - - - 272 - - - - - mixed-flow 200 - - med for round air ducts - - - - - - - - - - IPX4 no - 2400 0.45 IP20 2018 no no 101
Primo 200 (max) - - 1 1140 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 42 230 - - - 317 - - - - - mixed-flow 200 - - max for round air ducts - - - - - - - - - - IPX4 no - 2738 0.51 IP20 2018 no no 113
Primo 250 (min) - - 1 1038 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 39 230 - - - 288 - - - - - mixed-flow 250 - - min for round air ducts - - - - - - - - - - IPX4 no - 2292 0.70 IP20 2018 no no 144
Primo 250 (mid) - - 1 1447 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 41 230 - - - 402 - - - - - mixed-flow 250 - - med for round air ducts - - - - - - - - - - IPX4 no - 2626 0.81 IP20 2018 no no 173
Primo 250 (max) - - 1 1715 - - Inline - Supply and exhaust 50 - - - - - - -25...+55 43 230 - - - 476 - - - - - mixed-flow 250 - - max for round air ducts - - - - - - - - - - IPX4 no - 2876 0.84 IP20 2018 no no 188
Primo 355 (min) - - 1 2090 - - Inline - Supply and exhaust 50 - - - - - - -25…+55 38 230 - - - 581 - 126 - - - mixed-flow 355 - - min for round air ducts - - - - - - - - - - IPX4 no - 1350 0.60 IP20 2018 no no -
Primo 355 (mid) - - 1 2296 - - Inline - Supply and exhaust 50 - - - - - - -25…+55 38 230 - - - 638 - 131 - - - mixed-flow 355 - - med for round air ducts - - - - - - - - - - IPX4 no - 1400 0.58 IP20 2018 no no -
Primo 355 (max) - - 1 2485 - - Inline - Supply and exhaust 50 - - - - - - -25…+55 43 230 - - - 690 - 150 - - - mixed-flow 355 - - max for round air ducts - - - - - - - - - - IPX4 no - 1470 0.66 IP20 2018 no no -
Primo 355 (220/60)
(min)
- - 1 1277 - - Inline - Supply and exhaust 60 - - - - - polymer -25…+55 37 230 - - - 355 - - - - - mixed-flow 355 - - min for round air ducts - - - - - - - - - - IPX4 no - 996 0.43 IP20 2018 no no 90
Primo 355 (220/60)
(mid)
- - 1 1771 - - Inline - Supply and exhaust 60 - - - - - polymer -25…+55 38 230 - - - 492 - - - - - mixed-flow 355 - - med for round air ducts - - - - - - - - - - IPX4 no - 1360 0.60 IP20 2018 no no 128
Primo 355 (220/60)
(max)
- - 1 2600 - - Inline - Supply and exhaust 60 - - - - - polymer -25…+55 43 230 - - - 722 - - - - - mixed-flow 355 - - max for round air ducts - - - - - - - - - - IPX4 no - 1632 0.85 IP20 2018 no no 182
Primo 400 (min) - - 1 2677 - - Inline - Supply and exhaust 50 - - - - - - -25…+55 40 230 - - - 744 - 197 - - - mixed-flow 400 - - min for round air ducts - - - - - - - - - - IPX4 no - 1320 0.91 IP20 2018 no no -
Primo 400 (mid) - - 1 3136 - - Inline - Supply and exhaust 50 - - - - - - -25…+55 42 230 - - - 871 - 204 - - - mixed-flow 400 - - med for round air ducts - - - - - - - - - - IPX4 no - 1390 0.90 IP20 2018 no no -
Primo 400 (max) - - 1 3350 - - Inline - Supply and exhaust 50 - - - - - - -25…+55 43 230 - - - 931 - 224 - - - mixed-flow 400 - - max for round air ducts - - - - - - - - - - IPX4 no - 1446 0.98 IP20 2018 no no -
Primo 400 (220/60)
(min)
- - 1 1846 - - Inline - Supply and exhaust 60 - - - - - polymer -25…+55 38 230 - - - 513 - - - - - mixed-flow 400 - - min for round air ducts - - - - - - - - - - IPX4 no - 1000 0.73 IP20 2018 no no 146
Primo 400 (220/60)
(mid)
- - 1 2401 - - Inline - Supply and exhaust 60 - - - - - polymer -25…+55 42 230 - - - 667 - - - - - mixed-flow 400 - - med for round air ducts - - - - - - - - - - IPX4 no - 1320 1.00 IP20 2018 no no 208
Primo 400 (220/60)
(max)
- - 1 3390 - - Inline - Supply and exhaust 60 - - - - - polymer -25…+55 43 230 - - - 942 - - - - - mixed-flow 400 - - max for round air ducts - - - - - - - - - - IPX4 no - 1566 1.40 IP20 2018 no no 300
Primo EC 150 - - 1 700 - - Inline - Supply and exhaust 50/60 - - - - - - -25...+55 39 230 - - - 194 - - - - - mixed-flow 150 - - - for round air ducts - - - - - - - - - - IPX4 yes - 3700 0.48 IP44 2018 no no 54
Primo EC 160 - - 1 700 - - Inline - Supply and exhaust 50/60 - - - - - - -25...+55 39 230 - - - 194 - 54 - - - mixed-flow 160 - - - for round air ducts - - - - - - - - - - IPX4 yes - 3700 0.48 IP44 2018 no no -
Pages