Mode | Voltage | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Form | Length | Material | Device | Current | Maximum air flow | Frequency | RPM | Speed | Heat recovery efficiency | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Max. air flow at air flow direction (perpendicular air flow) | Max. air flow at air flow direction (direct air flow) | Heat exchanger type | Heat exchanger material | Electric heater power | Sound pressure level at 1 m | Sound pressure level at 3 m | Outdoor sound pressure attenuation | Regeneration efficiency | Insulation class | Number of electrical heating elements | Transported air temperature | Electric heater current | Current | Connected air duct diameter | Connected air duct size | Filter | Transported air temperature | Number of water coil rows | Humidity recovery efficiency | Insulation | Heat recovery efficiency | Total unit power | Rated current | Operating temperature range | Voltage | Maximum air flow | Weight | ErP | Maximum air flow | Maximum air flow | Extract filter | Supply filter | Air speed | Maximum operating pressure | Motor IP rating | Max. power without electric heater | Max. unit current without electric heater | Max. unit current | Max. unit power with electric heater | Max. unit current with electric heater | Current | Filter | Remote control panel | Functions | Power | Motor max. power | Transported air temperature | Perm. amb. temp. | Lamp model Osram | Starting current | Radiation power (UVC) | Lamp dimensions |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Primo EC 355 max | 230 | Inline | mixed-flow | 355 | for round air ducts | - | - | - | yes | no | no | - | - | - | - | - | 4630 | 50 | 3175 | - | - | - | Supply and exhaust | - | - | - | - | IPX4 | 1 | 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25…+55 | - | - | - | - | - | - | - | - | 1286 | - | 2018 | - | - | - | - | - | - | IP44 | - | - | - | - | - | 3.10 | - | - | - | 701 | - | - | - | - | - | - | - |
SD 160/1200 | - | - | - | 160 | for round air ducts | - | - | galvanized steel | - | - | - | - | 1200 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 6.2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-QR 200 2Е 50 Hz |
230 | wall mounting | axial | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 860 | 50 | 2300 | - | - | - | Exhaust, Supply | - | 55 | - | - | IPX4 | 1 | 48 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | 239 | 2.8 | - | - | - | - | - | - | - | IP24 | - | - | - | - | - | 0.26 | - | - | - | - | - | - | - | - | - | - | - |
Axis-QR 200 2Е 60 Hz |
230 | wall mounting | axial | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 875 | 60 | 2550 | - | - | - | Exhaust, Supply | - | 61 | - | - | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | 243 | 2.8 | - | - | - | - | - | - | - | IP24 | - | - | - | - | - | 0.28 | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q EC 500 | 230 | wall mounting | axial | 520 | for round air ducts | - | - | polymer-coated steel | yes | no | no | - | - | - | - | - | 8500 | 50/60 | 1600 | - | - | - | Supply and exhaust | - | 700 | - | - | IPX5 | 1 | 70 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | –25…+60 | - | - | - | - | - | - | - | - | 2361 | 8.31 | - | - | - | - | - | - | - | IP55 | - | - | - | - | - | 3.1 | - | - | - | - | - | - | - | - | - | - | - |
Clean Box 160 UV | 1 ~ 230 | ceiling mounting, wall mounting, flush mounting | - | 160 | for round air ducts | - | - | polymer-coated steel | - | - | - | - | - | - | - | - | - | 50/60 | - | - | - | - | Supply | 13.4 | 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.8 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | HNS L 60 W 2G11 | 40 | 19 | 408 x 40 |
Tower-V EC 310 | 230 | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | - | - | - | 1.72 | 3100 | 50/60 | 2600 | - | - | - | Exhaust | - | 391 | -20...+60 | – | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 861 | 20 | 2018 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro-MZ 200 50 Hz |
220-240 | ceiling mounting, wall mounting | centrifugal | 200 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.63 | 1000 | 50 | 2824 | - | - | - | Supply and exhaust | 5.6 | 144 | - | B | IPX4 | 1 | 50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+50 | - | - | - | - | - | - | - | - | 278 | - | 2018 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro-MZ 200 60 Hz |
220-240 | ceiling mounting, wall mounting | centrifugal | 200 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.85 | 1045 | 60 | 3164 | - | - | - | Supply and exhaust | 5.6 | 193 | - | B | IPX4 | 1 | 50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+50 | - | - | - | - | - | - | - | - | 290 | - | 2018 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauAIR RV 800 | 200-240 | floor mounting, outdoor mounting | - | - | for round air ducts | - | - | aluzinc | yes | yes | yes | - | - | - | - | - | 800 | 50/60 | 2800 | - | - | - | Supply and exhaust | - | 2x280 | - | - | IP34 | 1 | 34 | - | - | - | - | - | - | - | - | - | B | - | - | - | - | - | - | - | -25...+40 | - | - | - | - | - | - | - | - | - | 270 | - | - | - | ePM1 ≥ 50% (ISO 16890) | F7 (EN 779) | - | - | IP54 | - | - | 2.5 | - | - | - | - | - | - | - | - | - | -35...+50 | - | - | - | - |
VENTO Ergo A50 S Pro (1 speed) |
- | wall mounting | - | - | 150 | - | - | - | - | - | - | - | - | - | - | 0.024 | 21 | 50/60 | 610 | - | - | - | - | - | 4.5 | - | A | IP24 | - | - | - | - | - | - | - | 22 | 13 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo A50 S Pro (2 speed) |
- | wall mounting | - | - | 150 | - | - | - | - | - | - | - | - | - | - | 0.026 | 32 | 50/60 | 800 | - | - | - | - | - | 5 | - | A | IP24 | - | - | - | - | - | - | - | 29 | 20 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo A50 S Pro (3 speed) |
- | wall mounting | - | - | 150 | - | - | - | - | - | - | - | - | - | - | 0.039 | 50 | 50/60 | 1450 | - | - | - | - | - | 7 | - | A | IP24 | - | - | - | - | - | - | - | 32 | 23 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
Box-F 50x30 4D | 400 | Inline | centrifugal | - | for rectangular air ducts | 500 | 300 | galvanized steel | no | no | no | - | - | - | - | 1.70 | 2350 | 50 | 1300 | - | - | - | Exhaust, Supply | - | 855 | -20...+50 | - | IPX4 | 3 | 56 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 653 | 33.0 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-FI 60x30 6D | 400 | Inline | centrifugal | - | for rectangular air ducts | 600 | 300 | galvanized steel | no | no | yes | - | - | - | - | 0.78 | 2320 | 50 | 920 | - | - | - | Exhaust, Supply | - | 397 | - | - | IPX4 | 3 | 41 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -20...+70 | - | - | - | - | - | - | - | - | 644 | 56 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BLAUBOX E 1000-9 Pro | 400 | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | 990 | 50 | 2780 | - | - | - | Supply | - | - | - | C | - | 3 | 30 | - | - | - | - | 9000 | - | - | - | - | - | 3 | -25...+40 | 13.0 | - | 250 | - | G4 | - | - | - | 25 mm mineral wool | - | - | - | - | - | 275 | 52 | 2016, 2018 | - | - | - | - | - | - | - | 194 | 0.84 | - | 9194 | 13.85 | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT D5 180 S3 | 230 | ceiling mounting, wall mounting | - | - | - | - | - | EPP | no | - | - | - | - | - | - | - | 220 | 50/60 | 2317 | - | - | - | - | - | 117 | - | D | - | 1 | 35 | - | - | counter-flow | polystyrene | - | - | - | - | - | - | - | - | - | - | 150 | - | - | -25...+40 | - | - | 15-30 mm, EPP | 86...98 | - | - | - | - | 61 | 14 | 2016 | - | - | G4 | G4, F7 (option) | - | - | - | - | - | - | - | - | 0.54 | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT Roto EC LW 2000-2 S18 | 230 | - | - | - | - | - | - | aluzinc | - | - | - | - | - | - | - | - | 2250 | 50/60 | 3000 | - | - | - | - | - | - | - | - | - | 1 | 64 | - | - | rotary | aluminum | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+40 | - | - | 25 mm mineral wool | 68–93 | - | - | - | - | 625 | - | 2016, 2018 | - | - | G4 | G4 | - | - | - | - | - | - | 1070 | 5 | - | - | - | - | - | 2 items x 448 | - | - | - | - | - | - |
Iso-V ЕС 500 | 400 | Inline | centrifugal | - | for round air ducts | - | - | - | yes | yes | yes | - | - | - | - | 2.1 | - | 50/60 | 1350 | - | - | - | Exhaust, Supply | 43.0 | 1320 | -25 +50 | - | IPX4 | 3 | 45 | 10450 | 9928 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2018 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
min | 230 | Inline | mixed-flow | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | - | - | - | - | 2543 | 50 | 1320 | min | - | - | Exhaust, Supply | 22.8 | 197 | - | - | IPX4 | 1 | 34 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 706 | - | 2018 | - | - | - | - | - | - | IP20 | - | - | - | - | - | 0.91 | - | - | - | - | - | -25...+55 | - | - | - | - | - |
mid | 230 | Inline | mixed-flow | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | - | - | - | - | 2979 | 50 | 1390 | med | - | - | Exhaust, Supply | 22.8 | 204 | - | - | IPX4 | 1 | 35 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 828 | - | 2018 | - | - | - | - | - | - | IP20 | - | - | - | - | - | 0.90 | - | - | - | - | - | -25...+55 | - | - | - | - | - |
max | 230 | Inline | mixed-flow | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | - | - | - | - | 3185 | 50 | 1446 | max | - | - | Exhaust, Supply | 22.8 | 224 | - | - | IPX4 | 1 | 37 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 885 | - | 2018 | - | - | - | - | - | - | IP20 | - | - | - | - | - | 0.98 | - | - | - | - | - | -25...+55 | - | - | - | - | - |
KFK 100х50-3 | - | - | - | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-QRA 250 50 Hz |
220-240 | wall mounting | axial | 250 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 1070 | 50 | 1300 | - | - | - | Exhaust, Supply | - | 68 | -30 … +40 | - | IPX4 | 1 | 37 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 297 | 4.10 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | 0.48 | - | - | - | - | - | - | - | - | - | - | - |
Axis-QRA 250 60 Hz |
220-240 | wall mounting | axial | 250 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 1050 | 60 | 1450 | - | - | - | Exhaust, Supply | - | 76 | -30 … +40 | - | IPX4 | 1 | 37 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 292 | 4.10 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | 0.51 | - | - | - | - | - | - | - | - | - | - | - |
Tower-HC 190 2E A (50 Hz) | 230 | for roof | centrifugal | - | for round air ducts | - | - | aluminium | no | yes | no | - | - | - | - | 0.29 | 670 | 50 | 2730 | - | - | - | Exhaust | - | 64 | -25…+50 | – | IPX4 | 1 | 48 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 186 | 6 | 2018 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-HC 190 2E A (60 Hz) | 230 | for roof | centrifugal | - | for round air ducts | - | - | aluminium | no | yes | no | - | - | - | - | 0.40 | 700 | 60 | 2980 | - | - | - | Exhaust | - | 89 | -25…+50 | – | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 194 | 6 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-RB 125 | 230 | Inline | centrifugal | 125 | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | 0.28 | 330 | 50 | 2560 | - | - | - | Exhaust, Supply | - | 61 | - | C | IPX4 | 1 | 35 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+55 | - | - | - | - | - | - | - | - | 92 | 13 | 2018 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Helix 200х80 4Е | 230 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | 0.55 | 730 | 50 | 1430 | - | - | - | Exhaust, Supply | 6.8 | 125 | -25 +45 | B | IPX4 | - | 63 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 203 | - | 2018 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/100x2 V3(1 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.32 | - | 50 | 1400 | - | - | 97 | Exhaust, Supply | 3.1 | 20 | 50 | C | IPX4 | - | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 27 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/100x2 V3(2 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.34 | - | 50 | 1800 | - | - | 138 | Exhaust, Supply | 3.1 | 26 | 50 | C | IPX4 | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/100x2 V3(3 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.4 | - | 50 | 2600 | - | - | 176 | Exhaust, Supply | 3.1 | 45 | 50 | C | IPX4 | - | 44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauAIR CFV 6000 | 380-480 | floor mounting, outdoor mounting | - | - | for rectangular air ducts | - | - | aluzinc | yes | yes | yes | - | - | - | - | - | 6000 | 50/60 | 1700 | - | - | - | Supply and exhaust | - | 2x2600 | - | - | IP34 | 3 | 34 | - | - | - | - | - | - | - | - | - | B | - | - | - | - | - | - | - | -25...+40 | - | - | - | - | - | - | - | - | - | 715 | - | - | - | ePM1 ≥ 50% (ISO 16890) | F7 (EN 779) | - | - | IP54 | - | - | 8.5 | - | - | - | - | - | - | - | - | - | -35...+50 | - | - | - | - |
KOMFORT LE 600-4 | 230 | ceiling mounting, wall mounting, floor mounting | - | - | - | - | - | aluzinc | - | - | - | - | - | - | - | - | 600 | 50/60 | 1350 | - | 85 | - | - | - | - | - | E | - | 1 | 32-48 | - | - | cross-flow | polystyrene | 4000 | - | - | - | - | - | - | - | 17.4 | 19.1 | 200 | - | - | -25...+40 | - | - | 25 mm mineral wool | - | 4390 | - | - | - | 167 | 54 | 2016 | - | - | G4 | G4 | - | - | - | 390 | 1.72 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso 125-2Е | 230 | Inline | centrifugal | - | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | 0.52 | 530 | 50 | 2650 | - | - | - | Exhaust, Supply | 4.57 | 155 | -25 +40 | C | IPX4 | - | 38.3 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 147 | - | 2018 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Primo EC 160 | 230 | Inline | mixed-flow | 160 | for round air ducts | - | - | - | yes | no | no | - | - | - | - | - | 700 | 50/60 | 3700 | - | - | - | Supply and exhaust | - | - | - | - | IPX4 | 1 | 39 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+55 | - | - | - | - | - | - | - | - | 194 | - | 2018 | - | - | - | - | - | - | IP44 | - | - | - | - | - | 0.48 | - | - | - | 54 | - | - | - | - | - | - | - |
SD 125/600 | - | - | - | 125 | for round air ducts | - | - | galvanized steel | - | - | - | - | 600 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2.7 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 500 4D 50 Hz |
400 | wall mounting | axial | 500 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 6570 | 50 | 1300 | - | - | - | Exhaust, Supply | - | 450 | - | - | IPX4 | 3 | 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | 1825 | 14.0 | - | - | - | - | - | - | - | IP54 | - | - | - | - | - | 0.9 | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 500 4D 60 Hz |
400 | wall mounting | axial | 500 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 6230 | 60 | 1605 | - | - | - | Exhaust, Supply | - | 370 | - | - | IPX4 | 3 | 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | 1731 | 14.0 | - | - | - | - | - | - | - | IP54 | - | - | - | - | - | 0.7 | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q EC 300 | 230 | wall mounting | axial | 317 | for round air ducts | - | - | polymer-coated steel | yes | no | no | - | - | - | - | - | 2400 | 50/60 | 2000 | - | - | - | Supply and exhaust | - | 150 | - | - | IPX5 | 1 | 57 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | –25…+60 | - | - | - | - | - | - | - | - | 667 | 3.4 | - | - | - | - | - | - | - | IP55 | - | - | - | - | - | 1.2 | - | - | - | - | - | - | - | - | - | - | - |
Clean Box 150 UV | 1 ~ 230 | ceiling mounting, wall mounting, flush mounting | - | 150 | for round air ducts | - | - | polymer-coated steel | - | - | - | - | - | - | - | - | - | 50/60 | - | - | - | - | Supply | 11.9 | 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.8 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | HNS L 60 W 2G11 | 40 | 19 | 408 x 40 |
Tower-V 450 4D | 400 | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | 1.50 | 5920 | 50 | 1440 | - | - | - | Exhaust | 41 | 755 | -30…+50 | - | IPX4 | 3 | 57 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1644 | - | 2018 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro-M EC 125 | 230 | Inline | centrifugal | 125 | for round air ducts | - | - | polymer-coated steel | yes | no | no | - | - | - | - | 0.58 | 480 | 50/60 | 3400 | - | - | - | Exhaust, Supply | - | 83 | - | B | IPX4 | 1 | 45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 133 | 3.58 | 2018 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+60 | - | - | - | - | - |
BlauAIR RH 2500 | 200-240 | floor mounting, outdoor mounting | - | - | for rectangular air ducts | - | - | aluzinc | yes | yes | yes | - | - | - | - | - | 2500 | 50/60 | 3000 | - | - | - | Supply and exhaust | - | 2x835 | - | - | IP34 | 1 | 37 | - | - | - | - | - | - | - | - | - | B | - | - | - | - | - | - | - | -25...+40 | - | - | - | - | - | - | - | - | - | 248 | - | - | - | ePM1 ≥ 50% (ISO 16890) | F7 (EN 779) | - | - | IP54 | - | - | 7.6 | - | - | - | - | - | - | - | - | - | -35...+50 | - | - | - | - |
VENTO Ergo V50-1 S Pro (1 speed) | 100-230 | wall mounting | - | - | 150x150 | - | - | - | - | - | - | - | - | - | - | 0.025 | 11 | 50/60 | 808 | - | - | - | - | - | 4.31 | - | A | IP24 | - | - | - | - | - | - | - | 28 | 19 | 19 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo V50-1 S Pro (2 speed) | 100-230 | wall mounting | - | - | 150x150 | - | - | - | - | - | - | - | - | - | - | 0.029 | 24 | 50/60 | 1264 | - | - | - | - | - | 4.92 | - | A | IP24 | - | - | - | - | - | - | - | 33 | 24 | 19 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo V50-1 S Pro (3 speed) | 100-230 | wall mounting | - | - | 150x150 | - | - | - | - | - | - | - | - | - | - | 0.035 | 35 | 50/60 | 1629 | - | - | - | - | - | 5.8 | - | A | IP24 | - | - | - | - | - | - | - | 39 | 29 | 19 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
Box-F 50x25 6E | 230 | Inline | centrifugal | - | for rectangular air ducts | 500 | 250 | galvanized steel | no | no | no | - | - | - | - | 1.22 | 1460 | 50 | 910 | - | - | - | Exhaust, Supply | - | 244 | -20...+50 | - | IPX4 | 1 | 45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 406 | 24.0 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-FI 50x30 4D | 400 | Inline | centrifugal | - | for rectangular air ducts | 500 | 300 | galvanized steel | no | no | yes | - | - | - | - | 1.70 | 2350 | 50 | 1300 | - | - | - | Exhaust, Supply | - | 855 | - | - | IPX4 | 3 | 47 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -20...+50 | - | - | - | - | - | - | - | - | 653 | 52.5 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BLAUBOX E 800-3.4 Pro | 230 | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | 810 | 50 | 2780 | - | - | - | Supply | - | - | - | C | - | 1 | 30 | - | - | - | - | 3400 | - | - | - | - | - | 2 | -25...+40 | 14.8 | - | 200 | - | G4 | - | - | - | 25 mm mineral wool | - | - | - | - | - | 225 | 52 | 2016, 2018 | - | - | - | - | - | - | - | 193 | 0.84 | - | 3593 | 15.64 | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-F 550 4Е 50 Hz |
230 | Inline | axial | 550 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 8800 | 50 | 1300 | - | - | - | Exhaust, Supply | - | 550 | - | - | IPX4 | 1 | 62 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | 2445 | 13.9 | - | - | - | - | - | - | - | IP24 | - | - | - | - | - | 2.55 | - | - | - | - | - | - | - | - | - | - | - |
Axis-F 550 4Е 60 Hz |
230 | Inline | axial | 550 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 8970 | 60 | 1580 | - | - | - | Exhaust, Supply | - | 654 | - | - | IPX4 | 1 | 63 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | 2492 | 13.9 | - | - | - | - | - | - | - | IP24 | - | - | - | - | - | 2.88 | - | - | - | - | - | - | - | - | - | - | - |
Blaubox EC ME 300-5.1 S31 | 400 | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for round air ducts | - | - | aluzinc | yes | no | - | - | - | - | - | - | 354 | 50 | - | - | - | - | Supply | - | - | - | - | - | 3 | 35 | - | - | - | - | 5100 | - | - | - | - | - | - | -30…+40 | - | - | 160 | - | - | - | - | - | 30 mm mineral wool | - | - | - | - | - | - | 24 | 2018 | - | - | - | - | - | - | - | 64 | 0.3 | - | 5164 | 7.4 | - | Coarce 90% / G4 (option: ePM1 70% / F7) | - | - | - | - | - | - | - | - | - | - |
BlauFlex Iso N 315/7.6 | - | - | - | 315 | for round air ducts | - | - | - | - | - | - | round | 7600 | - | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 mm mineral wool | - | - | - | -30...+120 | - | - | - | - | - | - | - | - | 30 | 3000 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-H EC 630 | 400 | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | - | - | - | 4.66 | 18270 | 50/60 | 1450 | - | - | - | Exhaust | - | 2973 | -25...+55 | – | IPX4 | 3 | 71 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 5075 | 101 | 2018 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT Ultra EC L2 300-E S14 white | 230 | ceiling mounting, wall mounting, floor mounting | - | 125 | for round air ducts | - | - | - | yes | no | yes | - | - | - | - | - | 300 | 50/60 | - | - | - | - | Supply and exhaust | - | 165 | - | A | - | 1 | 33 | - | - | cross-flow | enthalpy | - | - | - | - | - | - | - | - | - | 1.3 | - | - | - | -25...+40 | - | 26...45 | 20 mm mineral wool | 51...73 | - | - | - | - | 83 | 28 | 2016, 2018 | - | - | G4 | F8, G4 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
S-Vent 450х203-11.0-4D | 400 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | 24 | 19000 | 50 | 1450 | - | - | - | Exhaust, Supply | 105 | 11000 | +60 | - | IP54 | 3 | 84 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 5278 | - | - | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box EC 50x25-1 | 230 | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | yes | no | - | - | - | - | - | - | 1590 | 50/60 | 2500 | - | - | - | Exhaust, Supply | 15.7 | 252 | - | – | IPX4 | - | 45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+50 | - | - | - | - | - | - | - | - | 442 | - | 2018 | 1590 | 442 | - | - | - | - | IP54 | - | - | - | - | - | 1.85 | - | - | - | - | - | - | - | - | - | - | - |
BlauAIR CFH 9000 | 380-480 | floor mounting, outdoor mounting | - | - | for rectangular air ducts | - | - | aluzinc | yes | yes | yes | - | - | - | - | - | 9000 | 50/60 | 1700 | - | - | - | Supply and exhaust | - | 2x2650 | - | - | IP34 | 3 | 32 | - | - | - | - | - | - | - | - | - | B | - | - | - | - | - | - | - | -25...+40 | - | - | - | - | - | - | - | - | - | 1400 | - | - | - | ePM1 ≥ 50% (ISO 16890) | F7 (EN 779) | - | - | IP54 | - | - | 8.5 | - | - | - | - | - | - | - | - | - | -35...+50 | - | - | - | - |
KOMFORT L 1200 | 230 | ceiling mounting, wall mounting, floor mounting | - | - | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | 1200 | 50/60 | 1850 | - | 88 | - | Supply and exhaust | - | - | - | NRVU | - | 1 | 60 | - | - | cross-flow | polystyrene | - | - | - | - | - | - | - | - | - | 3.6 | 250 | - | - | -25...+40 | - | - | 50 mm mineral wool | - | 820 | - | - | - | 333 | 85 | - | - | - | G4 | G4 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix 160 min | 230 | Inline | mixed-flow | - | for round air ducts | - | - | polymer-coated steel | no | no | yes | - | - | - | - | 0.20 | 410 | 50/60 | 1985 | min | - | - | Exhaust, Supply | 6.3 | 45 | +60 | C | IPX4 | 1 | 26 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 114 | - | 2018 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix 160 max | 230 | Inline | mixed-flow | - | for round air ducts | - | - | polymer-coated steel | no | no | yes | - | - | - | - | 0.23 | 550 | 50/60 | 2640 | max | - | - | Exhaust, Supply | 6.3 | 52 | +60 | C | IPX4 | 1 | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 153 | - | 2018 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Primo 355 (min) | 230 | Inline | mixed-flow | 355 | for round air ducts | - | - | - | no | no | no | - | - | - | - | - | 2090 | 50 | 1350 | min | - | - | Supply and exhaust | - | - | - | - | IPX4 | 1 | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25…+55 | - | - | - | - | - | - | - | - | 581 | - | 2018 | - | - | - | - | - | - | IP20 | - | - | - | - | - | 0.60 | - | - | - | 126 | - | - | - | - | - | - | - |
Primo 355 (mid) | 230 | Inline | mixed-flow | 355 | for round air ducts | - | - | - | no | no | no | - | - | - | - | - | 2296 | 50 | 1400 | med | - | - | Supply and exhaust | - | - | - | - | IPX4 | 1 | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25…+55 | - | - | - | - | - | - | - | - | 638 | - | 2018 | - | - | - | - | - | - | IP20 | - | - | - | - | - | 0.58 | - | - | - | 131 | - | - | - | - | - | - | - |
Primo 355 (max) | 230 | Inline | mixed-flow | 355 | for round air ducts | - | - | - | no | no | no | - | - | - | - | - | 2485 | 50 | 1470 | max | - | - | Supply and exhaust | - | - | - | - | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25…+55 | - | - | - | - | - | - | - | - | 690 | - | 2018 | - | - | - | - | - | - | IP20 | - | - | - | - | - | 0.66 | - | - | - | 150 | - | - | - | - | - | - | - |
BLAUBOX DW 2300-4 Pro | 400 | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for rectangular air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | 2350 | 50 | 2690 | - | - | - | Supply | - | - | - | - | - | 3 | 54 | - | - | - | - | - | - | - | - | - | - | - | -25...+40 | - | 1.05 | - | 500х300 | - | - | 4 | - | 50 mm mineral wool | - | 620 | - | - | - | 653 | 63 | 2016, 2018 | - | - | - | G4 (Option: F7) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 300 2D 50 Hz |
400 | wall mounting | axial | 300 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 2310 | 50 | 2350 | - | - | - | Exhaust, Supply | - | 145 | - | - | IPX4 | 3 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | 642 | 5.4 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | 0.25 | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 300 2D 60 Hz |
400 | wall mounting | axial | 300 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 2390 | 60 | 2570 | - | - | - | Exhaust, Supply | - | 165 | - | - | IPX4 | 3 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | 664 | 5.4 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | 0.29 | - | - | - | - | - | - | - | - | - | - | - |