Mode | Voltage | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Heating | Form | Length | Material | Device | Current | Power | Maximum air flow | Frequency | RPM | Speed | Heat recovery efficiency | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Heat exchanger type | Heat exchanger material | Electric heater power | Sound pressure level at 1 m | Sound pressure level at 3 m | Outdoor sound pressure attenuation | Regeneration efficiency | Insulation class | Number of electrical heating elements | Transported air temperature | Electric heater current | Current | Connected air duct diameter | Connected air duct size | Filter | Transported air temperature | Number of water coil rows | Humidity recovery efficiency | Insulation | Heat recovery efficiency | Total unit power | Rated current | Sound pressure level at a distance of 1 m | Operating temperature range | Voltage | Max. unit power without an electric heater | Reheater power consumption | Maximum air flow | Weight | ErP | Maximum air flow | Extract filter | Supply filter | Air speed | Maximum operating pressure | Motor IP rating | Max. power without electric heater | Max. unit power | Max. unit current without electric heater | Max. unit current | Max. unit power with electric heater | Max. unit current with electric heater | Current | Preheater power consumption | Remote control panel | Functions | Power | * | Transported air temperature | Perm. amb. temp. | Lamp model Osram | Starting current | Radiation power (UVC) | Lamp dimensions |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Iso-RB 150 | 230 | Inline | centrifugal | 150 | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | 0.37 | - | 485 | 50 | 2620 | - | - | - | Exhaust, Supply | - | 84 | - | C | IPX4 | 1 | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+55 | - | - | - | - | - | - | - | - | - | - | - | 135 | 17 | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Helix 250х140 4E | 230 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 2.48 | - | 2000 | 50 | 1310 | - | - | - | Exhaust, Supply | 15.5 | 570 | -40 +70 | - | IPX4 | - | 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 556 | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/100x6 V3(1 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 0.32 | - | - | 50 | 1400 | - | - | 97 | Exhaust, Supply | 3.5 | 20 | 50 | C | IPX4 | - | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 27 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/100x6 V3(2 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 0.34 | - | - | 50 | 1800 | - | - | 138 | Exhaust, Supply | 3.5 | 26 | 50 | C | IPX4 | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/100x6 V3(3 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 0.4 | - | - | 50 | 2600 | - | - | 176 | Exhaust, Supply | 3.5 | 45 | 50 | C | IPX4 | - | 44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT ERV D 100 S4 | 230 | ceiling mounting, flush mounting | - | - | - | - | - | polymer-coated steel | no | - | - | - | - | - | - | - | - | - | 160 | 50 | 2750 | - | - | - | - | - | 76 | - | D | - | 1 | 47 | cross-flow | enthalpy membrane | - | - | - | - | - | - | - | - | - | - | 100 | - | - | -5...+40 | - | 32...47 | 5-10 mm, expanded polyurethane | 75...87 | - | - | - | - | - | - | - | 44 | 17 | 2016 | - | G4 | G4 + F8 (PM2.5 > 93 %) | - | - | - | - | - | - | - | - | - | 0.33 | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT LE 1200-9 | 400 | ceiling mounting, wall mounting, floor mounting | - | - | - | - | - | aluzinc | - | - | - | - | - | - | - | - | - | - | 1200 | 50/60 | 1850 | - | 78 | - | - | - | - | - | NRVU | - | 3 | 60 | cross-flow | polystyrene | 9000 | - | - | - | - | - | - | - | 13.0 | 16.6 | 250 | - | - | -25...+40 | - | - | 25 mm mineral wool | - | 9800 | - | - | - | - | - | - | 333 | 85 | - | - | G4 | G4 | - | - | - | 800 | - | 3.6 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso 200-4Е | 230 | Inline | centrifugal | - | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | 0.45 | - | 850 | 50 | 1300 | - | - | - | Exhaust, Supply | 8.25 | 115 | -25 +40 | – | IPX4 | - | 29.1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 236 | - | – | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Primo EC 355 | 230 | Inline | mixed-flow | 355 | for round air ducts | - | - | - | yes | no | no | - | - | - | - | - | - | - | 3685 | 50 | 2470 | - | - | - | Supply and exhaust | - | - | - | - | IPX4 | 1 | 55 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25…+55 | - | - | - | - | - | - | - | - | - | - | - | 1024 | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | 1.56 | - | - | - | 353 | - | - | - | - | - | - | - |
SD 150/600 | - | - | - | 150 | for round air ducts | - | - | galvanized steel | - | - | - | - | - | 600 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2.8 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 710 6D | 400 | wall mounting | axial | 710 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 15440 | 50 | 830 | - | - | - | Exhaust, Supply | - | 1150 | - | - | IPX4 | 3 | 63 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | - | - | - | 4289 | 33.0 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | 2.0 | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q EC 450 | 230 | wall mounting | axial | 465 | for round air ducts | - | - | polymer-coated steel | yes | no | no | - | - | - | - | - | - | - | 7400 | 50/60 | 1400 | - | - | - | Supply and exhaust | - | 380 | - | - | IPX5 | 1 | 65 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | –25…+60 | - | - | - | - | - | - | - | - | - | - | - | 2056 | 7.05 | - | - | - | - | - | - | IP55 | - | - | - | - | - | - | 1.7 | - | - | - | - | - | - | - | - | - | - | - |
Clean Box 160 G4-F8-Carbon UV | 1 ~ 230 | ceiling mounting, wall mounting, flush mounting | - | 160 | for round air ducts | - | - | polymer-coated steel | - | - | - | - | - | - | - | - | - | - | - | 50/60 | - | - | - | - | Supply | 14.8 | 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.8 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | HNS L 60 W 2G11 | 40 | 19 | 408 x 40 |
Tower-V EC 250 | 230 | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | - | - | - | - | 1.29 | - | 1470 | 50/60 | 3300 | - | - | - | Exhaust | - | 161 | -25...+60 | – | IPX4 | 1 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 408 | 11 | 2018 | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro-MZ 160 50 Hz |
220-240 | ceiling mounting, wall mounting | centrifugal | 160 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | - | 0.34 | - | 455 | 50 | 2760 | - | - | - | Supply and exhaust | 3.44 | 78 | - | B | IPX4 | 1 | 46 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+55 | - | - | - | - | - | - | - | - | - | - | - | 126 | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro-MZ 160 60 Hz |
220-240 | ceiling mounting, wall mounting | centrifugal | 160 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | - | 0.35 | - | 460 | 60 | 2820 | - | - | - | Supply and exhaust | 3.44 | 81 | - | B | IPX4 | 1 | 46 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+ 50 | - | - | - | - | - | - | - | - | - | - | - | 128 | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauAIR RH 5000 | 380-480 | floor mounting, outdoor mounting | - | - | for rectangular air ducts | - | - | aluzinc | yes | yes | yes | - | - | - | - | - | - | - | 5000 | 50/60 | 1350 | - | - | - | Supply and exhaust | - | 2x1410 | - | - | IP34 | 3 | 32 | - | - | - | - | - | - | - | B | - | - | - | - | - | - | - | -25...+40 | - | - | - | - | - | - | - | - | - | - | - | - | 559 | - | - | ePM1 ≥ 50% (ISO 16890) | F7 (EN 779) | - | - | IP54 | - | - | - | 3.95 | - | - | - | - | - | - | - | - | - | -35...+50 | - | - | - | - |
VENTO Ergo A50-1 S Pro (1 speed) |
100-230 | wall mounting | - | - | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.024 | - | 21 | 50/60 | 610 | - | - | - | - | - | 4.5 | - | A | IP24 | - | - | - | - | - | 22 | 13 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo A50-1 S Pro (2 speed) |
100-230 | wall mounting | - | - | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.026 | - | 32 | 50/60 | 800 | - | - | - | - | - | 5 | - | A | IP24 | - | - | - | - | - | 29 | 20 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo A50-1 S Pro (3 speed) |
100-230 | wall mounting | - | - | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.039 | - | 50 | 50/60 | 1450 | - | - | - | - | - | 7 | - | A | IP24 | - | - | - | - | - | 32 | 23 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
Box-F 50x30 4E | 230 | Inline | centrifugal | - | for rectangular air ducts | 500 | 300 | galvanized steel | no | no | no | - | - | - | - | - | 3.10 | - | 2350 | 50 | 1230 | - | - | - | Exhaust, Supply | - | 710 | -25...+70 | - | IPX4 | 1 | 57 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 653 | 33.0 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-FI 60x30 4E | 230 | Inline | centrifugal | - | for rectangular air ducts | 600 | 300 | galvanized steel | no | no | yes | - | - | - | - | - | 6.45 | - | 2950 | 50 | 1210 | - | - | - | Exhaust, Supply | - | 1240 | - | - | IPX4 | 1 | 51 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+50 | - | - | - | - | - | - | - | - | - | - | - | 820 | 56 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BLAUBOX E 800-3.4 Pro | 230 | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | - | - | 810 | 50 | 2780 | - | - | - | Supply | - | - | - | C | - | 1 | 30 | - | - | 3400 | - | - | - | - | - | 2 | -25...+40 | 14.8 | - | 200 | - | G4 | - | - | - | 25 mm mineral wool | - | - | - | - | - | - | - | - | 225 | 52 | 2016, 2018 | - | - | - | - | - | - | 193 | - | 0.84 | - | 3593 | 15.64 | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-F 250 4D 50 Hz |
400 | Inline | axial | 250 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 850 | 50 | 1400 | - | - | - | Exhaust, Supply | - | 60 | - | - | IPX4 | 3 | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | - | - | - | 236 | 4.0 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | 0.17 | - | - | - | - | - | - | - | - | - | - | - |
Axis-F 250 4D 60 Hz |
400 | Inline | axial | 250 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 885 | 60 | 1750 | - | - | - | Exhaust, Supply | - | 89 | - | - | IPX4 | 3 | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | - | - | - | 246 | 4.0 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | 0.22 | - | - | - | - | - | - | - | - | - | - | - |
Blaubox EC ME 1500-9 S31 | 400 | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for rectangular air ducts | - | - | aluzinc | yes | no | - | - | - | - | - | - | - | - | 1500 | 50 | - | - | - | - | Supply | - | - | - | - | - | 3 | 46 | - | - | 9.0 | - | - | - | - | - | - | -30…+40 | - | - | - | 500 × 250 | Coarce 90% / G4 (option: ePM1 70% / F7) | - | - | - | 30 mm mineral wool | - | - | - | - | - | - | - | - | - | 35 | 2018 | - | - | - | - | - | - | 0.223 | - | 1.7 | - | 9.223 | 14.8 | - | - | - | - | - | - | - | - | - | - | - | - |
BlauFlex Iso N 182/7.6 | - | - | - | 182 | for round air ducts | - | - | - | - | - | - | - | round | 7600 | - | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 mm mineral wool | - | - | - | - | -30...+120 | - | - | - | - | - | - | - | - | - | 30 | 3000 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-H EC 310 | 230 | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | - | - | - | - | 1.72 | - | 3100 | 50/60 | 2600 | - | - | - | Exhaust | - | 391 | -20...+60 | – | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 861 | 16 | 2018 | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
min | 230 | Inline | mixed-flow | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | - | - | - | - | - | - | 1986 | 50 | 1350 | min | - | - | Exhaust, Supply | 20.7 | 126 | - | - | IPX4 | 1 | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 552 | - | 2018 | - | - | - | - | - | IP20 | - | - | - | - | - | - | 0.60 | - | - | - | - | - | -25...+55 | - | - | - | - | - |
mid | 230 | Inline | mixed-flow | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | - | - | - | - | - | - | 2170 | 50 | 1400 | mid | - | - | Exhaust, Supply | 20.7 | 131 | - | - | IPX4 | 1 | 34 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 603 | - | 2018 | - | - | - | - | - | IP20 | - | - | - | - | - | - | 0.58 | - | - | - | - | - | -25...+55 | - | - | - | - | - |
max | 230 | Inline | mixed-flow | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | - | - | - | - | - | - | 2360 | 50 | 1470 | max | - | - | Exhaust, Supply | 20.7 | 150 | - | - | IPX4 | 1 | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 656 | - | 2018 | - | - | - | - | - | IP20 | - | - | - | - | - | - | 0.66 | - | - | - | - | - | -25...+55 | - | - | - | - | - |
KFK 70х40-3 | - | - | - | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-QA 250 50 Hz |
220-240 | wall mounting | axial | 250 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 1070 | 50 | 1300 | - | - | - | Exhaust, Supply | - | 68 | -30 … +40 | - | IPX4 | 1 | 37 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 297 | 4.88 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | 0.48 | - | - | - | - | - | - | - | - | - | - | - |
Axis-QA 250 60 Hz |
220-240 | wall mounting | axial | 250 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 1050 | 60 | 1450 | - | - | - | Exhaust, Supply | - | 76 | -30 … +40 | - | IPX4 | 1 | 37 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 292 | 4.88 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | 0.51 | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT Roto EC DE650 S17 | 230 | - | - | - | - | - | - | painted steel | - | - | - | - | - | - | - | - | - | - | 710 | 50/60 | 3600 | - | - | - | - | - | - | - | A | - | 1 | 36 | rotary | aluminum | - | - | - | - | - | - | - | - | 11.2 | - | 200 | - | - | -25...+40 | - | - | 40 mm mineral wool | 80–87 | - | - | - | - | - | - | 2800 | 197 | 104 | 2016, 2018 | - | G4 | G4 + F7 (Option: H13) | - | - | - | 367 | 3167 | 2.5 | 13.7 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Helix 180х92 4Е | 230 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 0.7 | - | 800 | 50 | 1465 | - | - | - | Exhaust, Supply | 7.1 | 160 | -25 +45 | B | IPX4 | - | 62 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 222 | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/80x5 V3(1 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 0.32 | - | - | 50 | 1400 | - | - | 97 | Exhaust, Supply | 3.7 | 20 | 50 | C | IPX4 | - | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 27 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/80x5 V3(2 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 0.34 | - | - | 50 | 1800 | - | - | 138 | Exhaust, Supply | 3.7 | 26 | 50 | C | IPX4 | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/80x5 V3(3 speed) | 230 | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | 0.4 | - | - | 50 | 2600 | - | - | 176 | Exhaust, Supply | 3.7 | 45 | 50 | C | IPX4 | - | 44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauAIR CFV 2500 | 200-240 | floor mounting, outdoor mounting | - | - | for rectangular air ducts | - | - | aluzinc | yes | yes | yes | - | - | - | - | - | - | - | 2500 | 50/60 | 3000 | - | - | - | Supply and exhaust | - | 2x750 | - | - | IP34 | 1 | 30 | - | - | - | - | - | - | - | B | - | - | - | - | - | - | - | -25...+40 | - | - | - | - | - | - | - | - | - | - | - | - | 307 | - | - | ePM1 ≥ 50% (ISO 16890) | F7 (EN 779) | - | - | IP54 | - | - | - | 6.8 | - | - | - | - | - | - | - | - | - | -35...+50 | - | - | - | - |
KOMFORT LE 350-3 | 230 | ceiling mounting, wall mounting, floor mounting | - | - | - | - | - | aluzinc | - | - | - | - | - | - | - | - | - | - | 350 | 50/60 | 1150 | - | 78 | - | - | - | - | - | E | - | 1 | 24-45 | cross-flow | polystyrene | 3000 | - | - | - | - | - | - | - | 13 | 14.2 | 125 | - | - | -25...+40 | - | - | 25 mm mineral wool | - | 3260 | - | - | - | - | - | - | 97 | 45 | 2016 | - | G4 | G4 | - | - | - | 260 | - | 1.2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix 200 min | 230 | Inline | mixed-flow | - | for round air ducts | - | - | polymer-coated steel | no | no | yes | - | - | - | - | - | 0.37 | - | 731 | 50/60 | 2376 | min | - | - | Exhaust, Supply | 8 | 82 | +60 | C | IPX4 | 1 | 30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 203 | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix 200 max | 230 | Inline | mixed-flow | - | for round air ducts | - | - | polymer-coated steel | no | no | yes | - | - | - | - | - | 0.49 | - | 1035 | 50/60 | 2445 | max | - | - | Exhaust, Supply | 8 | 110 | +60 | C | IPX4 | 1 | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 288 | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix 200 mid | 230 | Inline | mixed-flow | - | for round air ducts | - | - | polymer-coated steel | no | no | yes | - | - | - | - | - | 0.44 | - | 961 | 50/60 | 2382 | mid | - | - | Exhaust, Supply | 8 | 100 | +60 | C | IPX4 | 1 | 34 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 267 | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Primo 355 (220/60) (min) |
230 | Inline | mixed-flow | 355 | for round air ducts | - | - | polymer | no | no | no | - | - | - | - | - | - | 90 | 1277 | 60 | 996 | min | - | - | Supply and exhaust | - | - | - | - | IPX4 | 1 | 37 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25…+55 | - | - | - | - | - | - | - | - | - | - | - | 355 | - | 2018 | - | - | - | - | - | IP20 | - | - | - | - | - | - | 0.43 | - | - | - | - | - | - | - | - | - | - | - |
Primo 355 (220/60) (mid) |
230 | Inline | mixed-flow | 355 | for round air ducts | - | - | polymer | no | no | no | - | - | - | - | - | - | 128 | 1771 | 60 | 1360 | mid | - | - | Supply and exhaust | - | - | - | - | IPX4 | 1 | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25…+55 | - | - | - | - | - | - | - | - | - | - | - | 492 | - | 2018 | - | - | - | - | - | IP20 | - | - | - | - | - | - | 0.60 | - | - | - | - | - | - | - | - | - | - | - |
Primo 355 (220/60) (max) |
230 | Inline | mixed-flow | 355 | for round air ducts | - | - | polymer | no | no | no | - | - | - | - | - | - | 182 | 2600 | 60 | 1632 | max | - | - | Supply and exhaust | - | - | - | - | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25…+55 | - | - | - | - | - | - | - | - | - | - | - | 722 | - | 2018 | - | - | - | - | - | IP20 | - | - | - | - | - | - | 0.85 | - | - | - | - | - | - | - | - | - | - | - |
BLAUBOX DW 4100-3 Pro | 400 | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for rectangular air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | - | - | 4100 | 50 | 2840 | - | - | - | Supply | - | - | - | - | - | 3 | 75 | - | - | - | - | - | - | - | - | - | -25...+70 | - | 4.3 | - | 700х400 | - | - | 3 | - | 50 mm mineral wool | - | 2300 | - | - | - | - | - | - | 1139 | 110 | 2016, 2018 | - | - | G4 (Option: F7) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 400 4D 50 Hz |
400 | wall mounting | axial | 400 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 3740 | 50 | 1380 | - | - | - | Exhaust, Supply | - | 180 | - | - | IPX4 | 3 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | - | - | - | 1039 | 8.8 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | 0.47 | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 400 4D 60 Hz |
400 | wall mounting | axial | 400 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 3870 | 60 | 1625 | - | - | - | Exhaust, Supply | - | 195 | - | - | IPX4 | 3 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | - | - | - | 1075 | 8.8 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | 0.55 | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q EC 250 max | 230 | wall mounting | axial | 260 | for round air ducts | - | - | polymer-coated steel | yes | no | no | - | - | - | - | - | - | - | 1850 | 50/60 | 2950 | - | - | - | Supply and exhaust | - | 115 | - | - | IPX5 | 1 | 57 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | –25…+60 | - | - | - | - | - | - | - | - | - | - | - | 514 | 2.56 | - | - | - | - | - | - | IP55 | - | - | - | - | - | - | 0.85 | - | - | - | - | - | - | - | - | - | - | - |
Clean Box 150 G4-F8-Carbon UV | 1 ~ 230 | ceiling mounting, wall mounting, flush mounting | - | 150 | for round air ducts | - | - | polymer-coated steel | - | - | - | - | - | - | - | - | - | - | - | 50/60 | - | - | - | - | Supply | 13.3 | 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.8 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | HNS L 60 W 2G11 | 40 | 19 | 408 x 40 |
Tower-V 400 4D | 400 | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 0.99 | - | 3950 | 50 | 1440 | - | - | - | Exhaust | 33 | 420 | -30…+60 | - | IPX4 | 3 | 55 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1097 | - | 2018 | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro-M EC 250 L | 230 | Inline | centrifugal | 250 | for round air ducts | - | - | polymer-coated steel | yes | no | no | - | - | - | - | - | 0.74 | - | 985 | 50/60 | 2500 | - | - | - | Exhaust, Supply | - | 100 | -25...+60 | B | IPX4 | 1 | 44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 274 | 5.09 | 2018 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauAIR RH 800 | 200-240 | floor mounting, outdoor mounting | - | - | for round air ducts | - | - | aluzinc | yes | yes | yes | - | - | - | - | - | - | - | 800 | 50/60 | 2800 | - | - | - | Supply and exhaust | - | 2x270 | - | - | IP34 | 1 | 34 | - | - | - | - | - | - | - | B | - | - | - | - | - | - | - | -25...+40 | - | - | - | - | - | - | - | - | - | - | - | - | 190 | - | - | ePM1 ≥ 50% (ISO 16890) | F7 (EN 779) | - | - | IP54 | - | - | - | 2.5 | - | - | - | - | - | - | - | - | - | -35...+50 | - | - | - | - |
VENTO A50 (1 speed) | 220-240 | wall mounting | - | - | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.021 | - | 26 | 50 | 599 | - | - | - | - | - | 3.68 | - | A | IP24 | - | - | - | - | - | 24 | 14 | 18 | ≤ 90 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Mechanical | - | - | - | - | - | - | - | - | - |
VENTO A50 (2 speed) | 220-240 | wall mounting | - | - | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.026 | - | 53 | 50 | 1155 | - | - | - | - | - | 4.83 | - | A | IP24 | - | - | - | - | - | 34 | 24 | 18 | ≤ 90 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Mechanical | - | - | - | - | - | - | - | - | - |
Box-F 40x20 4D | 400 | Inline | centrifugal | - | for rectangular air ducts | 400 | 200 | galvanized steel | no | no | no | - | - | - | - | - | 0.60 | - | 1470 | 50 | 1300 | - | - | - | Exhaust, Supply | - | 282 | -25...+45 | - | IPX4 | 3 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 408 | 17.5 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-FI 50x25 6D | 400 | Inline | centrifugal | - | for rectangular air ducts | 500 | 250 | galvanized steel | no | no | yes | - | - | - | - | - | 0.67 | - | 1490 | 50 | 930 | - | - | - | Exhaust, Supply | - | 274 | - | - | IPX4 | 3 | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -20...+60 | - | - | - | - | - | - | - | - | - | - | - | 414 | 40.5 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BLAUBOX E 300-2.4 Pro | 230 | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | - | - | 285 | 50 | 2800 | - | - | - | Supply | - | - | - | A | - | 1 | 28 | - | - | 2400 | - | - | - | - | - | 3 | -25...+40 | 10.4 | - | 125 | - | G4 | - | - | - | 25 mm mineral wool | - | - | - | - | - | - | - | - | 79 | 50 | 2016, 2018 | - | - | - | - | - | - | 75 | - | 0.33 | - | 2475 | 10.73 | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-F 450 4Е 50 Hz |
230 | Inline | axial | 450 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 4680 | 50 | 1350 | - | - | - | Exhaust, Supply | - | 250 | - | - | IPX4 | 1 | 56 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | - | - | - | 1300 | 9.1 | - | - | - | - | - | - | IP24 | - | - | - | - | - | - | 1.2 | - | - | - | - | - | - | - | - | - | - | - |
Axis-F 450 4Е 60 Hz |
230 | Inline | axial | 450 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | - | 4790 | 60 | 1600 | - | - | - | Exhaust, Supply | - | 325 | - | - | IPX4 | 1 | 57 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | - | - | - | 1331 | 9.1 | - | - | - | - | - | - | IP24 | - | - | - | - | - | - | 1.46 | - | - | - | - | - | - | - | - | - | - | - |
Blaubox EC ME 1000-12 S31 | 400 | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for rectangular air ducts | - | - | aluzinc | yes | no | - | - | - | - | - | - | - | - | 1000 | 50 | - | - | - | - | Supply | - | - | - | - | - | 3 | 45 | - | - | 12.0 | - | - | - | - | - | - | -30…+40 | - | - | - | 400 × 200 | Coarce 90% / G4 (option: ePM1 70% / F7) | - | - | - | 30 mm mineral wool | - | - | - | - | - | - | - | - | - | 30 | 2018 | - | - | - | - | - | - | 0.165 | - | 1.3 | - | 12.165 | 19.5 | - | - | - | - | - | - | - | - | - | - | - | - |
CIVIC EC LB 1200 S21 | 230 | floor mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | - | - | - | - | - | - | - | 1240 | 50/60 | 3630 | - | - | - | Supply and exhaust | 394 | - | - | A+ | - | 1 | 24 | counter-flow | polystyrene | - | - | - | - | - | - | - | -25...+40 | - | - | 400 | - | - | - | - | - | 40 mm mineral wool | 84...96* | - | - | 34 | - | - | 350 | - | 344 | - | - | - | G4 | G4 + (option: F7) | - | - | - | - | - | 1.6 | - | - | 1.6 | - | - | Sensor, LCD | Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - | - |
Tower-H EC 190 | 230 | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | - | - | - | - | 0.77 | - | 670 | 50/60 | 3520 | - | - | - | Exhaust | - | 102 | -25...+60 | B | IPX4 | 1 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 186 | 8 | 2018 | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT Ultra EC L2 300-H S2 white | 230 | wall mounting, floor mounting | - | 125 | for round air ducts | - | - | - | yes | no | yes | - | - | - | - | - | - | - | 300 | 50/60 | 2050 | - | - | - | Supply and exhaust | - | 165 | - | B | - | 1 | 33 | cross-flow | polystyrene | - | - | - | - | - | - | - | - | - | 1.3 | - | - | - | -25...+40 | - | - | 20 mm mineral wool | 55...79 | - | - | - | - | - | - | - | 83 | 32 | 2016, 2018 | - | G4 | F8, G4 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
S-Vent 450х203-4.0-6D | 400 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | - | 9.1 | - | 11150 | 50 | 950 | - | - | - | Exhaust, Supply | 76.5 | 4000 | +60 | - | IP54 | 3 | 76 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3097 | - | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box EC 40x20-1 | 230 | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | yes | no | - | - | - | - | - | - | - | - | 810 | 50/60 | 2470 | - | - | - | Exhaust, Supply | 8.3 | 91 | - | B | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+50 | - | - | - | - | - | - | - | - | - | - | - | 225 | - | 2018 | - | - | - | - | - | IP55 | - | - | - | - | - | - | 0.69 | - | - | - | - | - | - | - | - | - | - | - |