Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy

Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Air handling units with heat recovery
  • Supply units
  • Modular air handling units BlauAir
  • Standard air handling units BlauAIR
Additionally
Show ×
Voltage
Phase
Outdoor mounting
EC motor
Type
Mounting
Air duct
Casing material
Hide filters
Fault
%
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Print version
Search results
Selected 395 products
Mode VoltageMountingDesignAir ductCasing materialEC motorOutdoor mountingSound-insulated casingMaximum air flowFrequencyRPMTypePowerMax. operating temperatureSEC classPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialElectric heater powerSound pressure level at 3 mTransported air temperature Electric heater currentCurrentConnected air duct diameterConnected air duct size Transported air temperatureNumber of water coil rowsInsulationHeat recovery efficiencyTotal unit powerReheater power consumptionMaximum air flowWeightErPBypassExtract filterSupply filterMax. power without electric heaterMax. unit powerMax. unit current without electric heaterMax. unit currentMax. unit power with electric heaterMax. unit current with electric heaterCurrentMaximum power consumption in "Heat Recovery + Heat Pump"Maximum power consumption in "Heat Recovery"Maximum power consumption in "Heat Recovery + Heat Pump + Pre-Heating"Air-handling unit energy efficiency "Heating" mode (COP)Air-handling unit energy efficiency "Cooling" mode (ERR)CoolantCoolant weightHeat output in "Heating" mode [kW] at t0 = +7 °C; tk = +45 °C*Compressor typeTemperature setting range in "Cooling/Heating"Heat output in "Cooling" mode [W] at t0 = +7 °C; tk = +45 °CFilterElectric heater current Max. power of electric heaterMax. unit current of electric heater*Motor max. powerTransported air temperatureMax. water temperatureWater coil connection diameter
Blaubox EC MW 3000 S31 230 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts aluzinc yes no - 2930 50 - Supply - - - 1 52 - - - - -30…+40 - - 600 x 300 - - 4 30 mm mineral wool - - - - 50 2018 - - - - 425 - 1.8 - - - - - - - - - - - - - - Coarce 90% / G4 (option: ePM1 70% / F7) - - - - - - 150 1 1/8
KOMFORT Roto EC SE 281-E L S21 230 - - - painted steel yes - - 382 50/60 - - - - A+ - - Sorption - - 28 - - - 160 - -25...+40 - 40 mm mineral wool 86 - - - 68 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 176 1376 1.34 6.66 - - - - - - - - - - - - - - - - 1200 5.32 - - - - -
KOMFORT Roto EC LE 1500-9 S17 400 - - - aluzinc - - - 1500 50/60 2000 - - - - 3 62 rotary aluminum 9000 - - - - 315 - -25...+40 - 25 mm mineral wool 72–95 - - 417 175 2016, 2018 - G4 G4 - - - - 9750 14.1 - - - - - - - - - - - - - - - - - 2 items x 222 - - -
KOMFORT EC S2B300-E S14 230 wall mounting, floor mounting - - polymer-coated steel yes - - 330 50/60 3200 - 170 - A 1 30 counter-flow enthalpy - - - - - 160 - -25...+60 - 20 mm mineral wool 76–90 - - 92 53 2016, 2018 - G4 F7 (option: G4) - - - - - - 1.3 - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 3000 S21 400 ceiling mounting - - aluzinc - - - 4300 50/60 - Supply and exhaust - - NRVU 3 46 cross-flow aluminum - - - - - 400 - -25...+40 2 25 mm mineral wool 59...72 - - 1195 268 - yes G4 G4 - 2226 - 3.5 - - - - - - - - - - - - - - - - - - - - - - -
Reneo S 350-E L S21 230 ceiling mounting, wall mounting, floor mounting - - expanded polypropylene yes - - 410 50/60 - - - 45 A 1 27 counter-flow enthalpy - - - - - 160 - - - 45 mm 83 - - - 26 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 210 210 1.54 1.54 - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DW 2300-4 Pro 400 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts aluzinc no no yes 2350 50 2690 Supply - - - 3 54 - - - - -25...+40 - 1.05 - 500х300 - 4 50 mm mineral wool - 620 - 653 63 2016, 2018 - - G4 (Option: F7) - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC LEHP 400 S17 230 - - - aluzinc - - - 520 50 - - - - - 1 45 rotary aluminum - - - - - 160 - -25…+40 - - 85 - - 53 150 - - G4 G4 (Option: F7) - - - 10.9 - - - 0.745 0.31 2.145 6 4 R410A 0.8 1.56 Sealed, rotary type +16...+30 1.2 - - - - - - - - -
KOMFORT Roto EC DE250 S18 230 - - - painted steel - - - 310 50/60 2200 - - - A 1 21 rotary aluminum - - - 3.1 - 160 - -25...+40 - 40 mm mineral wool 71–87 - 700 86 56 2016, 2018 - G4 G4 + F7 (Option: H13) 135 835 1.0 4.1 - - - - - - - - - - - - - - - - - - - - - - -
Blaubox EC ME 4000-54 S31 400 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts aluzinc yes no - 5000 50 - Supply - - - 3 49 - - 54000 - -30…+40 - - 700 x 400 - - - 30 mm mineral wool - - - - 60 2018 - - - 717 - 1.1 - 54717 87.6 - - - - - - - - - - - - Coarce 90% / G4 (option: ePM1 70% / F7) - - - - - - - -
KOMFORT Roto EC S 281 R S21 230 - - - painted steel yes - - 382 50/60 - - - - A+ - - Condensing - - 28 - - - 160 - -25...+40 - 40 mm mineral wool 89 - - - 67 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 176 176 1.34 1.34 - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC LE 400-2 S17 230 - - - aluzinc - - - 400 50/60 3100 - - - A 1 45 rotary aluminum 2000 - - - - 160 - -25...+40 - 20 mm mineral wool 80–95 - - 111 112 2016, 2018 - G4 G4 - - - - 2290 9.9 - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC SB250 S11 220-240 wall mounting, floor mounting - - polymer-coated steel yes - - 290 50/60 2050 - 115 - A - 25 counter-flow polystyrene - - - - - 160 - -25...+40 - 30 mm mineral wool 85...94 - - 81 51 2016, 2018 - G4 G4, F7 - - - - - - 0.9 - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 550-E L S21 230 ceiling mounting - - aluzinc - - - 620 50/60 - Supply and exhaust - - A 1 30 counter-flow enthalpy - - - - - 200 - -25...+40 2 20 mm mineral wool 69...87 - - 172 68 - yes G4 G4 (Option: F7) - 297 - 2.4 - - - - - - - - - - - - - - - - - - - - - - -
Reneo-Fit D 200-E S21 230 ceiling mounting, wall mounting, floor mounting - - expanded polypropylene yes - - 309 50/60 - - - 45 A 1 34 counter-flow enthalpy - - - - - 125 / 160 - - - 25 mm 78 - - - 15 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) - 169 - 1.28 - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX MW 6500-4 Pro 400 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts aluzinc no no yes 6500 50 1400 Supply - - - 3 55 - - - - -25...+40 - 4.5 - 800х500 - 4 25 mm mineral wool - 1800 - 1806 136 2016, 2018 - - G4 - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC LW 2000-2 S18 230 - - - aluzinc - - - 2250 50/60 3000 - - - - 1 64 rotary aluminum - - - - - - - -25...+40 - 25 mm mineral wool 68–93 - - 625 - 2016, 2018 - G4 G4 - - - - 1070 5 - - - - - - - - - - - - - - - - - 2 items x 448 - - -
KOMFORT Roto EC DE 350 L/R S21 230 ceiling mounting, wall mounting - - galvanized steel yes no yes 430 50/60 3570 - - - A 1 31 rotary aluminum - - - 5.6 - 160 - -25...+40 - 40 mm mineral wool 72–87 - 1400 119 82 2016, 2018 - G4 G4, F7 (Option: H13) 185 1585 1.3 6.9 - - - - - - - - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141-7. - - - -
Reneo S 270 R S21 230 ceiling mounting, floor mounting - - expanded polypropylene yes - - 304 50/60 - - - - A 1 37 counter-flow polystyrene - - - - - 125 - - - 25 mm 91 - - - 22 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 176 176 1.34 1.34 - - - - - - - - - - - - - - - - - - - - -25...+40 - -
KOMFORT Roto EC D250 S17 230 - - - painted steel - - - 310 50/60 2200 - - - A 1 21 rotary aluminum - - - - - 160 - -25...+40 - 40 mm mineral wool 71–87 - - 86 55 2016, 2018 - G4 G4 + F7 (Option: H13) 135 135 1.0 1.0 - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC LBE 300-E S21 230 ceiling mounting, floor mounting - - galvanized steel - - - 380 50/60 - - - - A 1 24 counter-flow enthalpy 2800 - - - - 160 - -25…+40 - 40 mm mineral wool 74–89 - - 106 64.3 - - G4 G4, F7 182 - 1.4 - 2982 13.6 - - - - - - - - - - - - - 12.2 - - - - - - -
KOMFORT EC S200-E S11 230 wall mounting, floor mounting - - polymer-coated steel yes - - 260 50/60 2050 - 130 - A 1 24 counter-flow enthalpy - - - - - 125 - -25...+60 - 25 mm mineral wool 74–94 - - 72 45 2016, 2018 - - G3 - - - - - - 1.0 - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBE 550-E R S21 230 ceiling mounting - - aluzinc - - - 620 50/60 - Supply and exhaust - - A 1 30 counter-flow enthalpy - - - - - 200 - -25...+40 - 20 mm mineral wool 69...87 - - 172 67 - yes G4 G4 (Option: F7) 297 - 2.4 - 2297 11.1 - - - - - - - - - - - - - - 2000 8.7 - - - - -
Reneo-Fit D 150 S21 230 ceiling mounting, wall mounting, floor mounting - - expanded polypropylene yes - - 263 50/60 - - - 45 A+ 1 34 counter-flow polystyrene - - - - - 125 / 160 - - - 25 mm 88 - - - 12 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) - 115 - 0.92 - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX MW 1200-4 Pro 230 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts aluzinc no no yes 1200 50 1850 Supply - - - 1 38 - - - - -25...+40 - 1.8 - 400х200 - 4 25 mm mineral wool - 410 - 333 42.8 2016, 2018 - - G4 - - - - - - - - - - - - - - - - - - - - - - - - - - -
Pages