Search results
Selected 411 products
Mode VoltageMountingDesignAir ductCasing materialEC motorOutdoor mountingSound-insulated casingMaximum air flowFrequencyRPMHeat recovery efficiencyTypePowerMax. operating temperatureSEC classPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialElectric heater powerSound pressure level at 3 mFan currentTransported air temperature Electric heater currentCurrentConnected air duct diameterFan powerConnected air duct size FilterTransported air temperatureNumber of water coil rowsInsulationHeat recovery efficiencyTotal unit powerVoltageReheater power consumptionMaximum air flowWeightErPBypassExtract filterSupply filterMax. power without electric heaterMax. unit powerMax. unit current without electric heaterMax. unit currentMax. unit power with electric heaterMax. unit current with electric heaterCurrentMaximum power consumption in "Heat Recovery"Maximum power consumption in "Heat Recovery + Heat Pump"Maximum power consumption in "Heat Recovery"Air-handling unit energy efficiency "Heating" mode (COP)Air-handling unit energy efficiency "Cooling" mode (ERR)CoolantCoolant weightHeat output in "Heating" mode [kW] at t0 = +7 °C; tk = +45 °C*Heat output in "Cooling" mode [kW] at t0 = +7 °C; tk = +45 °C*Compressor typeTemperature setting range in "Cooling/Heating"Heat output in "Cooling" mode [W] at t0 = +7 °C; tk = +45 °CFilterMax. power of electric heaterMax. unit current of electric heater*Motor max. powerTransported air temperatureIntegrated electric preheater powerMax. water temperatureWater coil connection diameter
KOMFORT EC SB350-E S11 220-240 wall mounting, floor mounting - - polymer-coated steel yes - - 415 50/60 3200 - - 170 - A - 28 counter-flow enthalpy - - - - - - 160 - - - -25...+40 - 40 mm mineral wool 76...89 - - - 115 66 2016, 2018 - G4 F7 (option: G4) - - - - - - 1.3 - - - - - - - - - - - - - - - - - - - - -
Reneo-Fit D 100 S14 230 ceiling mounting - - EPP - - - 130 50/60 - - Supply and exhaust - - A+ 1 32 counter-flow polystyrene - - - - - - 100 / 125 - - - -23…+40 - 25 mm 82–94 - - - 36 8 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) - 45 - 0.34 - - - - - - - - - - - - - - - - - - - - - - - -
Reneo SE 350 R S21 230 ceiling mounting, wall mounting, floor mounting - - expanded polypropylene yes - - 410 50/60 - - - - 45 A+ 1 26 counter-flow polystyrene - - - - 4.66 - 160 - - - - - 45 mm 93 - - - - 26 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 213 1263 1.62 6.28 - - - - - - - - - - - - - - - - - - - - - 1050 - -
BLAUBOX DW 4100-3 Pro 400 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts aluzinc no no yes 4100 50 2840 - Supply - - - 3 75 - - - - - -25...+70 - 4.3 - - 700х400 - - 3 50 mm mineral wool - 2300 - - 1139 110 2016, 2018 - - G4 (Option: F7) - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC D2E350 S17 230 - - - painted steel - - - 400 50/60 3200 - - - - A 1 33 rotary aluminum - - - - 5.6 - 160 - - - -25...+40 - 20 mm mineral wool 73–87 - - 1400 111 79 2016, 2018 - G4 G4 + F7 (Option: H13) 200 1600 1.3 6.9 - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC LB 400-E S21 230 ceiling mounting, floor mounting - - galvanized steel - - - 540 50/60 - - - - - A 1 27 counter-flow enthalpy - - - - - - 200 - - - -25…+40 - 40 mm mineral wool 78–89 - - - 150 74.8 - - G4 G4, F7 289 - 2.1 - - - - - - - - - - - - - - - - - - - - - - - - -
Blaubox EC MW 1500 S31 230 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts aluzinc yes no - 1445 50 - - Supply - - - 1 49 - - - - - -30…+40 - - 500 x 250 - - - - 4 30 mm mineral wool - - - - - 49 2018 - - - - 222 - 1.6 - - - - - - - - - - - - - - - Coarce 90% / G4 (option: ePM1 70% / F7) - - - - - - 150 1
KOMFORT Roto EC SE 281 L S21 230 - - - painted steel yes - - 382 50/60 - - - - - A+ - - Condensing - - 26 - - - - 160 - - - -25...+40 - 40 mm mineral wool 89 - - - - 57 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 179 1379 1.34 6.66 - - - - - - - - - - - - - - - - 1200 5.32 - - - - - -
KOMFORT Roto EC LW 400-2 S17 230 - - - aluzinc - - - 400 50/60 3100 - - - - A 1 45 rotary aluminum - - - - - - 160 - - - -25...+40 - 20 mm mineral wool 80–95 - - - 111 112 2016, 2018 - G4 G4 - - - - 290 1.2 - - - - - - - - - - - - - - - - - 2 items x 100 - - - -
KOMFORT EC SB 250-E S14 230 wall mounting, floor mounting - - polymer-coated steel yes - - 390 50/60 - - - 180 - A 1 35 counter-flow enthalpy - - - - - - 160 - - - -25...+40 - 30 mm mineral wool 78...90 - - - 108 66 2018 - G4 G4 (Option: F7) - - - - - - 1.37 - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBW 900-E R S21 230 ceiling mounting - - aluzinc - - - 1030 50/60 - - Supply and exhaust - - A 1 33 counter-flow enthalpy - - - - - - 250 - - - -25...+40 2 20 mm mineral wool 69...85 - - - 286 112 - yes G4 G4 (Option: F7) - 442 - 3 - - - - - - - - - - - - - - - - - - - - - - - -
Reneo S 350 L S21 230 ceiling mounting, wall mounting, floor mounting - - expanded polypropylene yes - - 410 50/60 - - - - 45 A+ 1 26 counter-flow polystyrene - - - - - - 160 - - - - - 45 mm 93 - - - - 26 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 213 213 1.62 1.62 - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DE 3300-21 Pro 400 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts aluzinc no no yes 3350 50 2730 - Supply - - - 3 57 - - 21000 - 2.4 -25...+40 30.0 32.4 - 1.33 600х350 G4 - - 50 mm mineral wool - 22330 - - 931 91 2016, 2018 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC LHP 400 S17 230 - - - aluzinc - - - 520 50 - - - - - - 1 45 rotary aluminum - - - - - - 160 - - - -10…+40 - - 85 - - - 53 150 - - G4 G4 (Option: F7) - - - 4.6 - - - - 0.745 0.31 6 4 R410A 0.8 1.56 - Sealed, rotary type +16...+30 1.2 - - - - - - - - -
KOMFORT Roto EC D2E250 S18 230 - - - painted steel - - - 300 50/60 2200 - - - - A 1 23 rotary aluminum - - - - 3.1 - 160 - - - -25...+40 - 20 mm mineral wool 72–87 - - 700 83 54 2016, 2018 - G4 G4 + F7 (Option: H13) 128 828 0.9 4.0 - - - - - - - - - - - - - - - - - - - - - - - -
Reneo SE 270 L S21 230 ceiling mounting, floor mounting - - expanded polypropylene yes - - 304 50/60 - - - - - A 1 37 counter-flow polystyrene - - - - 6.21 - 125 - - - - - 25 mm 91 - - - - 22 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 176 1576 1.34 7.55 - - - - - - - - - - - - - - - - - - - - -25...+40 1400 - -
KOMFORT Roto EC SKE 200 R S21 230 wall mounting - - painted steel yes - - 270 50 - - - - - A 1 33 rotary aluminum - - - - - - 125 - - - -25…+40 - 25 mm mineral wool 87-93 - - - - 53 - - G4 G4 (Option: F7) 171 871 1.31 4.31 - - - - - - - - - - - - - - - - 700 4.31 - - - - - -
KOMFORT LW 1700-4 230 ceiling mounting, wall mounting, floor mounting - - aluzinc - - - 1700 50 1100 77 - 980 - - 1 49 cross-flow polystyrene - - - - - 4.3 315 - - - -25...+40 4 50 mm mineral wool - - - - 472 99 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC S250 S11 220-240 wall mounting, floor mounting - - polymer-coated steel yes - - 290 50/60 2050 - - 115 - A - 25 counter-flow polystyrene - - - - - - 160 - - - -25...+40 - 30 mm mineral wool 85...94 - - - 81 51 2016, 2018 - G4 G4, F7 - - - - - - 0.9 - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC DBE 2000 S21 400 ceiling mounting - - aluzinc - - - 2100 50/60 - - Supply and exhaust - - NRVU 3 36 cross-flow aluminum - - - - - - 315 - - - -25...+40 - 25 mm mineral wool 50...67 - - - 583 140 - yes G4 G4 1063 - 4.7 - 16063 26.4 - - - - - - - - - - - - - - 15000 21.7 - - - - - -
Reneo-Fit D 150-E S14 230 ceiling mounting, wall mounting, floor mounting - - expanded polypropylene yes - - 263 50/60 - - - - 45 A 1 34 counter-flow enthalpy - - - - - - 125 / 160 - - - - - 25 mm 79 - - - - 15 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) - 115 - 0.92 - - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX MW 3000-4 Pro 400 (Y) ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts aluzinc no no yes 3000 50 1200 - Exhaust - - - 3 53 - - - - - -40...+45 - 2.3 - - 600х300 - - 4 25 mm mineral wool - 1270 - - 833 73.2 2016, 2018 - - G4 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT Roto EC LW 1500-2 S18 230 - - - aluzinc - - - 1500 50/60 2000 - - - - - 1 62 rotary aluminum - - - - - - 315 - - - -25...+40 - 25 mm mineral wool 72–95 - - - 417 175 2016, 2018 - G4 G4 - - - - 750 3.2 - - - - - - - - - - - - - - - - - 2 items x 222 - - - -
KOMFORT Roto EC DE 250 L/R S21 230 ceiling mounting, wall mounting - - galvanized steel yes no yes 310 50/60 2200 - - - - A 1 21 rotary aluminum - - - - 3.1 - 160 - - - -25...+40 - 40 mm mineral wool 71-87 - - 700 86 56 2016, 2018 - G4 G4, F7 (Option: H13) 135 835 1.0 4.1 - - - - - - - - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141-7. - - - - -
Reneo SE 210-E R S21 230 ceiling mounting, floor mounting - - expanded polypropylene yes - - 255 50/60 - - - - - A 1 34 counter-flow enthalpy - - - - 3.55 - 125 - - - - - 25 mm 83 - - - - 20 - - G4 / Coarse > 60 % G4 / Coarse > 60 % (option: F7 / ePM1 60 %) 114 914 0.92 4.47 - - - - - - - - - - - - - - - - - - - - -25...+40 800 - -