Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Single-room reversible units Vento
  • Single-room units Freshbox
  • Single-room ventilation units Civic
Additionally
Show ×
Voltage
Functions
Remote control panel
Heating
Casing material
Mounting
Hide filters
Fault
%
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Print version
Search results
Selected 116 products
Mode VoltageMountingAir ductCasing materialEC motorHeatingCurrentPowerMaximum air flowFrequencyRPMSpeedTypeWeight PowerSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialSound pressure level at 1 mSound pressure level at 3 mOutdoor sound pressure attenuationRegeneration efficiencyTransported air temperature Connected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeFilterTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140Regeneration efficiency in accordance with DIBt LÜ-A 20Humidity recovery efficiencyInsulationHeat recovery efficiencySound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionInsulation thiknessMaximum air flowSFPWeightMaximum air flowExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeAir flow in heat recovery modeAir flow in heat recovery modeMax. power without electric heaterMax. unit current without electric heaterMax. unit current with electric heaterPreheater power consumptionMax. current consumption with heater(s)Sound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Air flow in heat recovery modeAir flow in heat recovery modeRemote control panelFunctionsRemote control panelIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8Power********Transported air temperatureSound power level LwA to environmentSound pressure level LpA to environment at 1 m distanceSound pressure level LpA to environment at 3 m distanceExtract filter ISO 16890 / EN 779:2012Supply filter ISO 16890 / EN 779:2012Connected air duct diameter
CIVIC EC LBE2 300 230 floor mounting - polymer-coated steel yes electric preheating, electric reheating - - 320 50/60 2150 - Supply and exhaust 140±3% - A - 1 21 counter-flow polystyrene - - - - -25...+40 200 - - - - - - - 40 mm mineral wool 78...92* 31 - 125 1400 - 89 - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - - 0.9 13.1 1400 - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
VENTO Solar V60 Pro (1 speed) - wall mounting - - - - 0.018 2.8 35 - 1150 - - - - A+ IP24 - 24 - - - - 19 up to 88 - - - - - - - - - - - 34 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
VENTO Solar V60 Pro (2 speed) - wall mounting - - - - 0.028 4.8 58 - 2100 - - - - A+ IP24 - 29 - - - - 19 up to 88 - - - - - - - - - - - 41 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
VENTO Expert A50-1 S W V.2 (1 speed) 100-240 wall mounting 160 - yes - 0.035 - - 50/60 800 - - - 4.45 - IP24 - - - - - - - - - - 15 8 - - 42 - - - - - - - - - - 2.14 - - - - 4 2 - - - - - - - 20 11 G3 (Option: F8 PM2,5 > 99 %*) up to 93 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S2** - - - - - -20...+40 - - - - - -
VENTO Expert A50-1 S W V.2 (2 speed) 100-240 wall mounting 160 - yes - 0.040 - - 50/60 1300 - - - 5.08 - IP24 - - - - - - - - - - 30 15 - - 42 - - - - - - - - - - 1.22 - - - - 8 4 - - - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 93 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S2** - - - - - -20...+40 - - - - - -
VENTO Expert A50-1 S W V.2 (3 speed) 100-240 wall mounting 160 - yes - 0.059 - - 50/60 1900 - - - 7.06 - IP24 - - - - - - - - - - 50 25 - - 42 - - - - - - - - - - 1.02 - - - - 14 7 - - - - - - - 30 21 G3 (Option: F8 PM2,5 > 99 %*) up to 93 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S2** - - - - - -20...+40 - - - - - -
VENTO Eco2 A50 S1 Pro (1 speed) - wall mounting 160 - - - 0.030 - - 50/60 1030 - - - 2.07 A IP24 - - - - 22 13 - - - - 15 15 G3 (F8 PM2.5 > 99 %) -20…+50 41 ≤ 92 - - - - 100-230 - - - - - - - - - 4 4 - - - - - - - - - - - - - Sensor Filter replacement indication, Timer - - - - - - - - - - - - - - -
VENTO Eco2 A50 S1 Pro (2 speed) - wall mounting 160 - - - 0.049 - - 50/60 1760 - - - 4.15 A IP24 - - - - 29 20 - - - - 30 30 G3 (F8 PM2.5 > 99 %) -20…+50 41 ≤ 92 - - - - 100-230 - - - - - - - - - 8 8 - - - - - - - - - - - - - Sensor Filter replacement indication, Timer - - - - - - - - - - - - - - -
VENTO Eco2 A50 S1 Pro (3 speed) - wall mounting 160 - - - 0.098 - - 50/60 2690 - - - 10.10 A IP24 - - - - 32 23 - - - - 50 50 G3 (F8 PM2.5 > 99 %) -20…+50 41 ≤ 92 - - - - 100-230 - - - - - - - - - 14 14 - - - - - - - - - - - - - Sensor Filter replacement indication, Timer - - - - - - - - - - - - - - -
Vento Expert Duo A30-1 S10 Pro
(1 speed)
100-240 - 160 - yes - 0.027 - 10 50/60 1600 - - - 2.00 - IP24 - - - - - - - - -15…+40 - - - G3 - 42 - - - - - - - - - 3 0.72 - - - - - - 60 16 - - - - - 33 24 - up to 85 - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - D2 - - - - - - - - - - - - -
Vento Expert Duo A30-1 S10 Pro
(2 speed)
100-240 - 160 - yes - 0.043 - 20 50/60 2200 - - - 3.70 - IP24 - - - - - - - - -15…+40 - - - G3 - 42 - - - - - - - - - 6 0.67 - - - - - - 60 16 - - - - - 40 31 - up to 85 - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - D2 - - - - - - - - - - - - -
Vento Expert Duo A30-1 S10 Pro
(3 speed)
100-240 - 160 - yes - 0.067 - 30 50/60 2500 - - - 6.40 - IP24 - - - - - - - - -15…+40 - - - G3 - 42 - - - - - - - - - 8 0.77 - - - - - - 60 16 - - - - - 43 34 - up to 85 - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - D2 - - - - - - - - - - - - -
VENTO Expert A50-1 Pro (1 speed) 100-230 wall mounting 160 - - - 0.025 - - 50/60 800 - - - 3.61 A IP24 - - - - 20 11 - - - - 15 8 G3 (F8 PM2.5 > 99 %) - 42 ≤ 93 - - - - - - - - - - - - - - 4 2 - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - - -20...+40 - - - - - -
VENTO Expert A50-1 Pro (2 speed) 100-230 wall mounting 160 - - - 0.03 - - 50/60 1300 - - - 4.15 A IP24 - - - - 27 18 - - - - 30 15 G3 (F8 PM2.5 > 99 %) - 42 ≤ 93 - - - - - - - - - - - - - - 8 4 - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - - -20...+40 - - - - - -
VENTO Expert A50-1 Pro (3 speed) 100-230 wall mounting 160 - - - 0.039 - - 50/60 1900 - - - 5.20 A IP24 - - - - 30 21 - - - - 50 25 G3 (F8 PM2.5 > 99 %) - 42 ≤ 93 - - - - - - - - - - - - - - 14 7 - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - - -20...+40 - - - - - -
Vento Ergo A50 S10 Pro1
(1 speed)
- - 150 - - - 0.024 - 21 50/60 610 I - - 4.5 - IP24 1 - - - - - - - - - - - - -20...+40 40 - - - - - 100-230 - - - 6 1.54 - - - - - - - - - - - - - 22 13 G3 (Option: F8 PM2,5 > 99 %*) up to 88 - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - - -
Vento Ergo A50 S10 Pro1
(2 speed)
- - 150 - - - 0.026 - 32 50/60 800 II - - 5 - IP24 1 - - - - - - - - - - - - -20 … +40 40 - - - - - 100-230 - - - 9 1.12 - - - - - - - - - - - - - 29 20 G3 (Option: F8 PM2,5 > 99 %*) up to 88 - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - - -
Vento Ergo A50 S10 Pro1
(3 speed)
- - 150 - - - 0.039 - 50 50/60 1450 III - - 7 - IP24 1 - - - - - - - - - - - - -20 … +40 40 - - - - - 100-230 - - - 14 1.01 - - - - - - - - - - - - - 32 23 G3 (Option: F8 PM2,5 > 99 %*) up to 88 - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed I
230 - - polymer-coated steel - electric preheating - - 30 50/60 2000 I - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - - 85 - - - 30 8 - 55 - G4 G4 + F7 (Option: H13) - - - - 10 - - 650 4.0 - 12 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed II
230 - - polymer-coated steel - electric preheating - - 60 50/60 2000 II - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - - 81 - - - 30 17 - 55 - G4 G4 + F7 (Option: H13) - - - - 15 - - 650 4.0 - 22 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed III
230 - - polymer-coated steel - electric preheating - - 90 50/60 2000 III - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - - 75 - - - 30 25 - 55 - G4 G4 + F7 (Option: H13) - - - - 25 - - 650 4.0 - 30 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed IV
230 - - polymer-coated steel - electric preheating - - 120 50/60 2000 IV - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - - 68 - - - 30 33 - 55 - G4 G4 + F7 (Option: H13) - - - - 44 - - 650 4.0 - 36 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed V
230 - - polymer-coated steel - electric preheating - - 200 50/60 2000 V - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - - 66 - - - 30 56 - 55 - G4 G4 + F7 (Option: H13) - - - - 134 - - 650 4.0 - 45 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - -
Freshbox 110 ERV
Speed I
230 - - polymer-coated steel yes without heating 0.26 10 - 50/60 3200 I - 20 - A - 1 - counter-flow enthalpy - - - - - - - - - -15…+40 - - 45* 10 85* - - - - - - - - 30 - - - - - - - - - - - - - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - 31 20 10 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 2×100 mm + optional 1×100 mm
Freshbox 110 ERV
Speed II
230 - - polymer-coated steel yes without heating 0.26 15 - 50/60 3200 II - 20 - A - 1 - counter-flow enthalpy - - - - - - - - - -15…+40 - - 39* 10 80* - - - - - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - 41 30 21 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 2×100 mm + optional 1×100 mm
Freshbox 110 ERV
Speed III
230 - - polymer-coated steel yes without heating 0.26 31 - 50/60 3200 III - 20 - A - 1 - counter-flow enthalpy - - - - - - - - - -15…+40 - - 29* 10 72* - - - - - - - - 100 - - - - - - - - - - - - - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - 51 40 31 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 2×100 mm + optional 1×100 mm
Vento Eco2 A50-4 S Pro (1 speed) - - 160 - - - 0.033 - - 50/60 915 I - - 2.37 - IP24 - - - - - - - - - - 15 - - -20(-30**) … +40 41 - - - - - 100-240 - - - - 0.57 - - - - 4 - - - - - - - - 21 12 G3 (Option: F8 PM2,5 > 99 %*) up to 92 15 4 Sensor Filter replacement indication, Timer - D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - - - - - -
Vento Eco2 A50-4 S Pro (2 speed) - - 160 - - - 0.047 - - 50/60 1555 II - - 3.80 - IP24 - - - - - - - - - - 30 - - -20(-30**) … +40 41 - - - - - 100-240 - - - - 0.46 - - - - 8 - - - - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 92 30 8 Sensor Filter replacement indication, Timer - D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - - - - - -
Vento Eco2 A50-4 S Pro (3 speed) - - 160 - - - 0.080 - - 50/60 2330 III - - 7.61 - IP24 - - - - - - - - - - 50 - - -20(-30**) … +40 41 - - - - - 100-240 - - - - 0.55 - - - - 14 - - - - - - - - 29 20 G3 (Option: F8 PM2,5 > 99 %*) up to 92 50 14 Sensor Filter replacement indication, Timer - D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - - - - - -
Freshbox E1-100 WiFi
Speed I
230 - - polymer-coated steel - electric reheating - - 30 50/60 2200 I - - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -20...+40 - - - - 98 - - - 350 10 8 - 31 - G4 G4 - - - - 20 0.4 1.94 - - - 13 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E1-100 WiFi
Speed II
230 - - polymer-coated steel - electric reheating - - 44 50/60 2200 II - - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -20...+40 - - - - 95 - - - 350 10 12 - 31 - G4 G4 - - - - 23 0.4 1.94 - - - 20 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E1-100 WiFi
Speed III
230 - - polymer-coated steel - electric reheating - - 60 50/60 2200 III - - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -20...+40 - - - - 92 - - - 350 10 17 - 31 - G4 G4 - - - - 29 0.4 1.94 - - - 27 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E1-100 WiFi
Speed IV
230 - - polymer-coated steel - electric reheating - - 75 50/60 2200 IV - - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -20...+40 - - - - 90 - - - 350 10 21 - 31 - G4 G4 - - - - 37 0.4 1.94 - - - 33 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E1-100 WiFi
Speed V
230 - - polymer-coated steel - electric reheating - - 100 50/60 2200 V - - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -20...+40 - - - - 89 - - - 350 10 28 - 31 - G4 G4 - - - - 53 0.4 1.94 - - - 39 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
VENTO Ergo A50-1 Pro
(1 speed)
- wall mounting 150 - - - 0.024 - 21 50/60 610 - - - 4.5 A IP24 - - - - 22 13 40 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - - -
VENTO Ergo A50-1 Pro
(2 speed)
- wall mounting 150 - - - 0.026 - 32 50/60 800 - - - 5 A IP24 - - - - 29 20 40 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - - -
VENTO Ergo A50-1 Pro
(3 speed)
- wall mounting 150 - - - 0.039 - 50 50/60 1450 - - - 7 A IP24 - - - - 32 23 40 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - - -
CIVIC EC DBE2 500 S21 230 ceiling mounting - polymer-coated steel yes electric preheating, electric reheating - - 510 50/60 1700 - Supply and exhaust 130 - A - 1 24 counter-flow polystyrene - - - - -25...+40 250 - - - - - - - 25 mm, cellular synthetic rubber 74...86* 34 - 170 1750 - 142 - - - G4 G4, F8 (option F8 C + H11) - - - - - 1.7 18.2 1750 - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Vento Expert A30 S10 W V.2
(1 speed)
100-240 wall mounting 100 - yes - 0.027 - 10 50/60 1600 - - - 1.80 - IP24 - 21 - - - - - - - - - 5 G3 -15…+40 42 - - - - 30 - - - - 3 1.30 - - - - - 1 - - - - - - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor - D1 - - - - - - - - - - - - -
Vento Expert A30 S10 W V.2
(2 speed)
100-240 wall mounting 100 - yes - 0.037 - 20 50/60 2200 - - - 3 - IP24 - 28 - - - - - - - - - 10 G3 -15…+40 42 - - - - 37 - - - - 6 1.08 - - - - - 3 - - - - - - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor - D1 - - - - - - - - - - - - -
Vento Expert A30 S10 W V.2
(3 speed)
100-240 wall mounting 100 - yes - 0.051 - 30 50/60 2500 - - - 4.40 - IP24 - 31 - - - - - - - - - 15 G3 -15…+40 42 - - - - 40 - - - - 8 1.06 - - - - - 4 - - - - - - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor - D1 - - - - - - - - - - - - -
VENTO Ergo V50 Pro (1 speed) 100-230 wall mounting 150x150 - - - 0.025 - 11 50/60 808 - - - 4.31 A IP24 - - - - 28 19 19 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - - -
VENTO Ergo V50 Pro (2 speed) 100-230 wall mounting 150x150 - - - 0.029 - 24 50/60 1264 - - - 4.92 A IP24 - - - - 33 24 19 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - - -
VENTO Ergo V50 Pro (3 speed) 100-230 wall mounting 150x150 - - - 0.035 - 35 50/60 1629 - - - 5.8 A IP24 - - - - 39 29 19 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - - -
Vento Ergo A85-1 Pro V.3
(1 speed)
- - 150 - yes - 0.034 - 36 50/60 1000 I - - 4.74 - IP24 1 - - - - - - - - - - 18 - -20...+40 40 - - - - - 100-240 - - - 10 0.95 - - - - - 5 - - - - - - - 29 19 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 90 - - - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - - - - - - - - -
Vento Ergo A85-1 Pro V.3
(2 speed)
- - 150 - yes - 0.050 - 59 50/60 1500 II - - 6.56 - IP24 1 - - - - - - - - - - 30 - -20...+40 40 - - - - - 100-240 - - - 16 0.80 - - - - - 8 - - - - - - - 35 25 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 90 - - - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - - - - - - - - -
Vento Ergo A85-1 Pro V.3
(3 speed)
- - 150 - yes - 0.071 - 85 50/60 2045 III - - 9.65 - IP24 1 - - - - - - - - - - 43 - -20...+40 40 - - - - - 100-240 - - - 24 0.82 - - - - - 12 - - - - - - - 44 34 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 90 - - - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - - - - - - - - -
Freshbox E-100 ERV
Speed I
230 wall mounting - polymer-coated steel yes electric preheating - - 30 50/60 2200 I - 31 - A - 1 - counter-flow enthalpy - - - - - 100 - - - -20...+40 - - - - 90 - - - - 10 8 - - - G4 G4, F8 (Option: F8 C, H13) - - - - 12 0.4 3.6 700 - - 13 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E-100 ERV
Speed II
230 wall mounting - polymer-coated steel yes electric preheating - - 60 50/60 2200 II - 31 - A - 1 - counter-flow enthalpy - - - - - 100 - - - -20...+40 - - - - 86 - - - - 10 17 - - - G4 G4, F8 (Option: F8 C, H13) - - - - 21 0.4 3.6 700 - - 27 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
Freshbox E-100 ERV
Speed III
230 wall mounting - polymer-coated steel yes electric preheating - - 100 50/60 2200 III - 31 - A - 1 - counter-flow enthalpy - - - - - 100 - - - -20...+40 - - - - 83 - - - - 10 28 - - - G4 G4, F8 (Option: F8 C, H13) - - - - 45 0.4 3.6 700 - - 39 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
VENTO A50-1 S (1 speed) 220-240 wall mounting 150 - - - 0.021 - 26 50 599 - - - 3.68 A IP24 - - - - 24 14 18 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - - -
VENTO A50-1 S (2 speed) 220-240 wall mounting 150 - - - 0.026 - 53 50 1155 - - - 4.83 A IP24 - - - - 34 24 18 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - - -
Vento Expert A50-1 W V.3
(I speed)
100-240 - 160 - yes - 0.035 - - 50/60 800 I - - - - IP24 - - - - - - - - - - 15 8 - -20...+40 41/47** - - - - - - - - - - 2.4 - - - - 4 2 - - - - - - - 13 4 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** 5.0 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application - - - - - - - -
Vento Expert A50-1 W V.3
(II speed)
100-240 - 160 - yes - 0.04 - - 50/60 1300 II - - - - IP24 - - - - - - - - - - 30 15 - -20...+40 41/47** - - - - - - - - - - 1.44 - - - - 8 4 - - - - - - - 25 16 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** 6.0 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application - - - - - - - -
Vento Expert A50-1 W V.3
(III speed)
100-240 - 160 - yes - 0.059 - - 50/60 1900 III - - - - IP24 - - - - - - - - - - 50 25 - -20...+40 41/47** - - - - - - - - - - 1.22 - - - - 14 7 - - - - - - - 37 28 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** 8.5 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application - - - - - - - -
CIVIC EC DB 300 S21 230 ceiling mounting - polymer-coated steel yes without heating - - 300 50/60 2150 - Supply and exhaust 78 - A - 1 23 counter-flow polystyrene - - - - -25...+40 200 - - - - - - - 25 mm, cellular synthetic rubber 76...88* 33 - 125 - - 83 - - - G4 G4, F8 (option F8 C + H11) - - - - - 1.3 1.3 - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
VENTO V50-1 S (1 speed) 220-240 wall mounting 164x164 - - - 0.021 - 26 50 599 - - - 3.68 A IP24 - - - - 24 14 19 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - - -
VENTO V50-1 S (2 speed) 220-240 wall mounting 164x164 - - - 0.026 - 53 50 1155 - - - 4.83 A IP24 - - - - 34 24 19 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - - -
CIVIC EC LBE2 1200 S21 400 floor mounting - polymer-coated steel yes electric preheating, electric reheating - - 1240 50/60 3630 - Supply and exhaust 402 - A+ - 3 24 counter-flow polystyrene - - - - -25...+40 400 - - - - - - - 40 mm mineral wool 84...96* 34 - 350 6300 - 344 - - - G4 G4 + (option: F7) - - - - - 1.6 18.7 6300 - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
CIVIC EC LBE 300-E S21 230 floor mounting - polymer-coated steel yes electric preheating - - 320 50/60 2150 - Supply and exhaust 137±3% - A - 1 21 counter-flow enthalpy - - - - -25...+40 200 - - - - - - - 40 mm mineral wool 73...89* 31 - 125 - - 89 - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - - 0.9 7 1400 - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - - -
VENTO Solar V60 S Pro (1 speed) - wall mounting - - - - 0.018 2.8 35 - 1150 - - - - A+ IP24 - 24 - - - - 19 up to 88 - - - - - - - - - - - 34 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
VENTO Solar V60 S Pro (2 speed) - wall mounting - - - - 0.018 2.8 35 - 1150 - - - - A+ IP24 - 24 - - - - 19 up to 88 - - - - - - - - - - - 34 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Vento Eco A50-4 S11 Pro (1 speed) 100-240 wall mounting 160 - yes - 0.017 - - 50/60 915 - - - 1.00 - IP24 - - - - - - - - - - 15 8 - 20(-30**) … +40 41 - - - - - - - - - - 0.48 - - - - 4 2 - - - - - - - 21 12 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - - Sensor Filter replacement indication, Timer - D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - - - - - -
Vento Eco A50-4 S11 Pro (2 speed) 100-240 wall mounting 160 - yes - 0.025 - - 50/60 1555 - - - 2.10 - IP24 - - - - - - - - - - 30 15 - 20(-30**) … +40 41 - - - - - - - - - - 0.50 - - - - 8 4 - - - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - - Sensor Filter replacement indication, Timer - D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - - - - - -
Vento Eco A50-4 S11 Pro (3 speed) 100-240 wall mounting 160 - yes - 0.041 - - 50/60 2330 - - - 4.30 - IP24 - - - - - - - - - - 50 25 - 20(-30**) … +40 41 - - - - - - - - - - 0.62 - - - - 14 7 - - - - - - - 29 20 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - - Sensor Filter replacement indication, Timer - D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - - - - - -