Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Heating | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Heat exchanger type | Heat exchanger material | Electric heater power | Sound pressure level at 1 m | Sound pressure level at 3 m | Outdoor sound pressure attenuation | Regeneration efficiency | Number of electrical heating elements | Transported air temperature | Electric heater current | Connected air duct diameter | Filter | Transported air temperature | Insulation | Heat recovery efficiency | Sound pressure level at a distance of 1 m | Voltage | Max. unit power without an electric heater | Reheater power consumption | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Extract filter | Supply filter | Motor IP rating | Max. power without electric heater | Max. unit current without electric heater | Max. unit power with electric heater | Max. unit current with electric heater | Current | Preheater power consumption | Remote control panel | Functions | Cable cross section | * | Motor max. power |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tower-V EC 400 | 230 | - | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | 3.90 | - | 5380 | - | 50/60 | 1450 | - | - | Exhaust | - | 526 | -25...+50 | – | IPX4 | 1 | 58 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1495 | - | 25 | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Сentro-M 450 (50 Hz) | 220-240 | - | Inline | centrifugal | 450 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | 2.89 | - | 5300 | - | 50 | 1265 | - | - | Exhaust, Supply | - | 665 | - | - | IPX4 | 1 | 65 | - | - | - | - | - | - | - | - | - | - | - | - | -40...+70 | - | - | - | - | - | - | 1472 | - | 27.26 | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
Сentro-M 450 (60 Hz) | 220-240 | - | Inline | centrifugal | 450 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | 5.40 | - | 6280 | - | 60 | 1560 | - | - | Exhaust, Supply | - | 1250 | - | - | IPX4 | 1 | 73 | - | - | - | - | - | - | - | - | - | - | - | - | -25..+60 | - | - | - | - | - | - | 1745 | - | 27.26 | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
CIVIC EC LBE2 300 S21 V.2 | 230 | - | floor mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | electric preheating, electric reheating | - | - | 320 | - | 50/60 | - | - | - | Supply and exhaust | 103 | - | - | A | - | 1 | 37 | counter-flow | polystyrene | - | - | - | - | - | - | -25...+40 | - | 200 | - | - | 40 mm mineral wool | 85...94* | 47 | - | 96 | 700 | 89 | - | - | - | - | - | - | - | - | 0.75 | - | 11 | - | 1050 | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - |
VENTO Ergo A50 Pro (1 speed) |
- | - | wall mounting | - | - | 150 | - | - | - | - | - | - | - | 0.024 | - | 21 | - | 50/60 | 610 | - | - | - | - | 4.5 | - | A | IP24 | - | - | - | - | - | 22 | 13 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - |
VENTO Ergo A50 Pro (2 speed) |
- | - | wall mounting | - | - | 150 | - | - | - | - | - | - | - | 0.026 | - | 32 | - | 50/60 | 800 | - | - | - | - | 5 | - | A | IP24 | - | - | - | - | - | 29 | 20 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - |
VENTO Ergo A50 Pro (3 speed) |
- | - | wall mounting | - | - | 150 | - | - | - | - | - | - | - | 0.039 | - | 50 | - | 50/60 | 1450 | - | - | - | - | 7 | - | A | IP24 | - | - | - | - | - | 32 | 23 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - |
Box-F 60x30 6D | 400 | - | Inline | centrifugal | - | for rectangular air ducts | 600 | 300 | galvanized steel | no | no | no | - | 0.78 | - | 2320 | - | 50 | 920 | - | - | Exhaust, Supply | - | 397 | -20...+70 | - | IPX4 | 3 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 644 | - | 35.0 | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
Tower-HC 310 2E (50 Hz) | 230 | - | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 1.42 | - | 2150 | - | 50 | 2620 | - | - | Exhaust | - | 324 | -25…+50 | – | IPX4 | 1 | 58 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 597 | - | 10 | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
BLAUBOX E 1200-9 Pro | 400 | - | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | 1190 | - | 50 | 2600 | - | - | Supply | - | - | - | - | - | 3 | 30 | - | - | 9000 | - | - | - | - | 3 | -25...+40 | 13.0 | 315 | G4 | - | 25 mm mineral wool | - | - | - | - | - | 331 | - | 62 | 2016, 2018 | - | - | - | - | 171 | 0.77 | 9171 | 13.77 | - | - | - | - | - | - | - |
Axis-F 400 4D 50 Hz |
400 | - | Inline | axial | 400 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | 3740 | - | 50 | 1380 | - | - | Exhaust, Supply | - | 180 | - | - | IPX4 | 3 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | 1039 | - | 8.1 | - | - | - | - | IP44 | - | - | - | - | 0.47 | - | - | - | - | - | - |
Axis-F 400 4D 60 Hz |
400 | - | Inline | axial | 400 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | 3870 | - | 60 | 1625 | - | - | Exhaust, Supply | - | 195 | - | - | IPX4 | 3 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | 1075 | - | 8.1 | - | - | - | - | IP44 | - | - | - | - | 0.55 | - | - | - | - | - | - |
Bravo Still Chrome 100 | 220-240 | Chrome | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | 0.04 | 5.6 | 70 | 26* | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 19 | 0.29 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
KOMFORT EC SB160-E S11 | 220-240 | - | wall mounting, floor mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | - | - | - | 180 | - | 50/60 | 3770 | - | - | - | - | 51 | - | A | - | - | 24 | counter-flow | enthalpy | - | - | - | - | - | - | - | - | 125 | - | -25...+40 | 20 mm mineral wool | 80...94 | - | - | - | - | 50 | - | 44 | 2016, 2018 | - | G4 | F7 (option: G4) | - | - | - | - | - | 0.4 | - | - | - | - | - | - |
Tower-H EC 500 | 400 | - | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | 2.08 | - | 10900 | - | 50/60 | 1480 | - | - | Exhaust | - | 1350 | -25...+50 | – | IPX4 | 3 | 67 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3028 | - | 51 | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Turbo 315 min | 230 | - | Inline | mixed-flow | 315 | for round air ducts | - | - | plastic | no | no | no | - | 0.99 | - | 1420 | - | 50/60 | 2115 | - | - | Exhaust, Supply | 11.7 | 227 | 60 | – | IPX4 | 1 | 41 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 394 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
Turbo 315 max | 230 | - | Inline | mixed-flow | 315 | for round air ducts | - | - | plastic | no | no | no | - | 1.42 | - | 1750 | - | 50/60 | 2505 | - | - | Exhaust, Supply | 11.7 | 315 | 60 | – | IPX4 | 1 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 486 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
TwinBox EC 315 | 220-240 | - | Inline | mixed-flow | - | for round air ducts | - | - | galvanized steel | yes | no | yes | - | 1.56 | - | 2780 | - | 50/60 | 2474 | - | - | Exhaust | 97 | 355 | –25…+55 | - | IPX4 | 1 | 45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 772 | - | - | 2016, 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Valeo-BP 75/100 (1 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | - | - | 0.11 | - | 75 | 29* | 50 | - | I | - | Exhaust | - | 24 | +50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 21 | - | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | 3x1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Valeo-BP 75/100 (2 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | - | - | 0.13 | - | 100 | 38* | 50 | - | II | - | Exhaust | - | 29 | +50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 28 | - | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | 3x1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box EC 80x50-3 max | 400 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | yes | no | - | - | - | - | 8535 | - | 50/60 | 2400 | - | - | Exhaust, Supply | 54.3 | 2925 | - | – | IPX4 | 3 | 63 | - | - | - | - | - | - | - | - | - | - | - | - | -25...+50 | - | - | - | - | - | - | 2371 | - | - | 2018 | - | - | - | IP54 | - | - | - | - | 3.05 | - | - | - | - | - | - |
Axis-QR EC 350 | 230 | - | wall mounting | axial | 374 | for round air ducts | - | - | polymer-coated steel | yes | no | no | - | - | - | 3500 | - | 50/60 | 1670 | - | - | Supply and exhaust | - | 200 | - | - | IPX5 | 1 | 58 | - | - | - | - | - | - | - | - | - | - | - | - | –25…+60 | - | - | - | - | - | - | 972 | - | 3.8 | - | - | - | - | IP55 | - | - | - | - | 1.4 | - | - | - | - | - | - |
KOMFORT Roto EC LE 1200-6 S17 | 400 | - | - | - | - | - | - | - | aluzinc | - | - | - | - | - | - | 1200 | - | 50/60 | 1930 | - | - | - | - | - | - | - | - | 3 | 60 | rotary | aluminum | 6000 | - | - | - | - | - | - | - | 315 | - | -25...+40 | 20 mm mineral wool | 73–95 | - | - | - | - | 333 | - | 165 | 2016, 2018 | - | G4 | G4 | - | - | - | 6570 | 9.5 | - | - | - | - | - | - | 2 items x 208 |
Iso-K 400 4E | 230 | - | Inline | centrifugal | 400 | for round air ducts | - | - | galvanized steel | no | yes | yes | - | 5.00 | - | - | - | 50 | 1440 | - | 5392 | Exhaust | - | 1048 | -20…+120 | - | IP54 | 1 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 92 | - | 1498 | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Aero Gold 100 | 220-240 | Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | 0.085 | 14 | 102 | 38* | 50 | 2300 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 28 | 0.49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Iso-RB 125 | 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | aluzinc | no | no | yes | - | 0.28 | - | 330 | - | 50 | 2560 | - | - | Exhaust, Supply | - | 61 | - | C | IPX4 | 1 | 35 | - | - | - | - | - | - | - | - | - | - | - | - | -25...+55 | - | - | - | - | - | - | 92 | - | 13 | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
Tower-H 400 6E (50 Hz) | 230 | - | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 0.89 | - | 2740 | - | 50 | 945 | - | - | Exhaust | 32.7 | 184 | -30…+60 | - | IPX4 | 1 | 47 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 761 | - | - | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Tower-H 400 6E (60 Hz) | 230 | - | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 1.10 | - | 3289 | - | 60 | 1071 | - | - | Exhaust | 32.7 | 249 | -30…+60 | - | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 914 | - | - | – | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Quatro Hi-Tech Gold 100 (127-220V/60Hz) | 127 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | 0.115 | 10 | 82 | 33* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 23 | 0.44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Hi-Tech Gold 100 (127-220V/60Hz) | 220 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | 0.054 | 9 | 82 | 33* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 23 | 0.40 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box-FI 80x50 6D | 400 | - | Inline | centrifugal | - | for rectangular air ducts | 800 | 500 | galvanized steel | no | no | yes | - | 5.18 | - | 7610 | - | 50 | 830 | - | - | Exhaust, Supply | - | 2790 | - | - | IPX4 | 3 | 53 | - | - | - | - | - | - | - | - | - | - | - | - | -20...+50 | - | - | - | - | - | - | 2114 | - | 127 | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - |
S-Vent 160x74-0.55-4D | 400 | - | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 1.6 | - | 750 | - | 50 | 1360 | - | - | Exhaust, Supply | 12.7 | 550 | +60 | D | IP54 | 3 | 62 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 208 | - | - | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/80x4 V3(1 speed) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | 0.32 | - | - | - | 50 | 1400 | - | 97 | Exhaust, Supply | 3.1 | 20 | 50 | C | IPX4 | - | 33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 27 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/80x4 V3(2 speed) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | 0.34 | - | - | - | 50 | 1800 | - | 138 | Exhaust, Supply | 3.1 | 26 | 50 | C | IPX4 | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 38 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 100/80x4 V3(3 speed) | 230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | 0.4 | - | - | - | 50 | 2600 | - | 176 | Exhaust, Supply | 3.1 | 45 | 50 | C | IPX4 | - | 44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 49 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |