Mode | Voltage | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Heating | Length | Current | Maximum air flow | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Max. air flow at air flow direction (perpendicular air flow) | Max. air flow at air flow direction (direct air flow) | Heat exchanger type | Heat exchanger material | Insulation class | Transported air temperature | Electric heater current | Current | Connected air duct diameter | Air flow in ventilation mode | Air flow in heat recovery mode | Connected air duct size | Transported air temperature | Outdoor sound pressure attenuation in accordance with DIN EN 20140 | Number of water coil rows | Insulation | Heat recovery efficiency | Total unit power | Sound pressure level at a distance of 1 m | Voltage | Max. unit power without an electric heater | Reheater power consumption | Insulation thikness | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Extract filter | Supply filter | Air flow in ventilation mode | Air flow in heat recovery mode | Motor IP rating | Max. power without electric heater | Max. unit power | Max. unit current without electric heater | Max. unit current | Max. unit power with electric heater | Max. unit current with electric heater | Current | Preheater power consumption | Sound pressure level at 1 m in accordance with ISO 3741:2004 | Sound pressure level at 3 m in accordance with ISO 3741:2004 | Remote control panel | Functions | Indoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8 | * | Motor max. power | ** | Transported air temperature | Perm. amb. temp. | Max. air flow at air flow direction (direct air flow) | Max. air flow at air flow direction (perpendicular air flow) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Axis-F 200 2Е 50 Hz |
230 | Inline | axial | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | 860 | 50 | 2300 | - | - | Exhaust, Supply | - | 55 | - | - | IPX4 | 1 | 48 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | - | - | 239 | - | 3.0 | - | - | - | - | - | - | IP24 | - | - | - | - | - | - | 0.26 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-F 200 2Е 60 Hz |
230 | Inline | axial | 200 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | 875 | 60 | 2550 | - | - | Exhaust, Supply | - | 61 | - | - | IPX4 | 1 | 49 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | - | - | 243 | - | 3.0 | - | - | - | - | - | - | IP24 | - | - | - | - | - | - | 0.28 | - | - | - | - | - | - | - | - | - | - | - | - | - |
CIVIC EC LB 1200 S21 V.2 | 230 | floor mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | 1240 | 50/60 | - | - | - | Supply and exhaust | 352 | - | - | – | - | 1 | 30 | - | - | counter-flow | polystyrene | - | -25...+40 | - | - | 400 | - | - | - | - | - | - | 40 mm mineral wool | 84…96* | - | 40 | - | 345 | - | - | 344 | - | - | - | - | - | - | - | - | - | - | - | 2.3 | - | - | - | - | - | - | - | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - | - |
CIVIC EC LB 300-E S21 | 230 | floor mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | 320 | 50/60 | 2150 | - | - | Supply and exhaust | 136±3% | - | - | A | - | 1 | 21 | - | - | counter-flow | enthalpy | - | -25...+40 | - | - | 200 | - | - | - | - | - | - | 40 mm mineral wool | 73...89* | - | 31 | - | 125 | - | - | 89 | - | - | - | - | G4 x 2 | G4 + F8 (option: F8 C + H11) | - | - | - | - | - | 0.9 | - | - | 0.9 | - | - | - | - | Sensor, LCD | Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - | - |
Tower-H 355 4D | 400 | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | 0.58 | 3290 | 50 | 1430 | - | - | Exhaust | 30.3 | 264 | -30…+60 | - | IPX4 | 3 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 914 | - | - | 2018 | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-H 355 4D (60 Hz) | 400 | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | 0.64 | 3540 | 60 | 1650 | - | - | Exhaust | 30.3 | 330 | -30…+60 | - | IPX4 | 3 | 53 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 983 | - | - | – | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix-E 400-4E | 230 | Inline | mixed-flow | 400 | for round air ducts | - | - | polymer-coated steel | no | no | yes | - | - | 3.43 | 3545 | 50 | 1480 | - | - | Exhaust, Supply | 35 | 580 | - | - | IPX4 | 1 | 50 | - | - | - | - | - | - | - | - | - | - | - | - | -25...+60 | - | - | - | - | - | - | - | - | - | - | 985 | - | - | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
S-Vent 315x143-2.2-6D | 400 | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | 5.6 | 4375 | 50 | 940 | - | - | Exhaust, Supply | 46.8 | 2200 | +60 | - | IP54 | 3 | 70 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1215 | - | - | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box 100x50 4D | 400 | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | 15000 | 50 | 1370 | - | - | Exhaust, Supply | 126.0 | 4300 | - | - | IPX4 | 3 | 70 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | - | - | 4167 | - | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | 6.8 | - | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT EC SB 250-E S14 | 230 | wall mounting, floor mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | - | - | - | 390 | 50/60 | - | - | - | - | - | 180 | - | A | - | 1 | 35 | - | - | counter-flow | enthalpy | - | - | - | - | 160 | - | - | - | -25...+40 | - | - | 30 mm mineral wool | 78...90 | - | - | - | - | - | - | 108 | - | 66 | 2018 | - | G4 | G4 (Option: F7) | - | - | - | - | - | - | - | - | - | 1.37 | - | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT Roto EC LW 400-2 S17 | 230 | - | - | - | - | - | - | aluzinc | - | - | - | - | - | - | 400 | 50/60 | 3100 | - | - | - | - | - | - | A | - | 1 | 45 | - | - | rotary | aluminum | - | - | - | - | 160 | - | - | - | -25...+40 | - | - | 20 mm mineral wool | 80–95 | - | - | - | - | - | - | 111 | - | 112 | 2016, 2018 | - | G4 | G4 | - | - | - | - | - | - | - | 290 | 1.2 | - | - | - | - | - | - | - | - | 2 items x 100 | - | - | - | - | - |
Iso-V 500 4D | 400 | Inline | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | aluminium, aluzinc | no | yes | yes | - | - | 3 | - | 50 | 1375 | - | - | Exhaust, Supply | 56 | 1430 | - | - | IPX4 | 3 | 58 | 7940 | 7200 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | – | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -40...+80 | - | 2000 | 2206 |
TwinBox EC 200 | 220-240 | Inline | mixed-flow | - | for round air ducts | - | - | galvanized steel | yes | no | yes | - | - | 0.94 | 910 | 50/60 | 3404 | - | - | Exhaust | 39 | 117 | –25…+55 | - | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | 253 | - | - | 2016, 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
SD 150/900 | - | - | - | 150 | for round air ducts | - | - | galvanized steel | - | - | - | - | 900 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 4.2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-QR 500 4D 50 Hz |
400 | wall mounting | axial | 500 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | 6570 | 50 | 1300 | - | - | Exhaust, Supply | - | 450 | - | - | IPX4 | 3 | 60 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | - | - | 1825 | - | 14.0 | - | - | - | - | - | - | IP24 | - | - | - | - | - | - | 0.9 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-QR 500 4D 60 Hz |
400 | wall mounting | axial | 500 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | 6230 | 60 | 1605 | - | - | Exhaust, Supply | - | 370 | - | - | IPX4 | 3 | 60 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | - | - | 1731 | - | 14.0 | - | - | - | - | - | - | IP24 | - | - | - | - | - | - | 0.7 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-HC EC 190 | 230 | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | - | 0.87 | 770 | 50/60 | 3538 | - | - | Exhaust | - | 110 | -25...+60 | – | IPX4 | 1 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 214 | - | 6 | 2018 | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT Roto EC D2E350 S17 | 230 | - | - | - | - | - | - | painted steel | - | - | - | - | - | - | 400 | 50/60 | 3200 | - | - | - | - | - | - | A | - | 1 | 33 | - | - | rotary | aluminum | - | - | 5.6 | - | 160 | - | - | - | -25...+40 | - | - | 20 mm mineral wool | 73–87 | - | - | - | - | 1400 | - | 111 | - | 79 | 2016, 2018 | - | G4 | G4 + F7 (Option: H13) | - | - | - | 200 | 1600 | 1.3 | 6.9 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-AM 150 (60 Hz) | 230 | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | 0.52 | 580 | 60 | 2855 | - | - | Exhaust | 7.2 | 119 | -25…+50 | B | IPX4 | - | 48 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 161 | - | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-AM 150 (50 Hz) | 230 | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | 0.43 | 555 | 50 | 2705 | - | - | Exhaust | 7.2 | 98 | -25…+55 | B | IPX4 | - | 47 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 154 | - | - | 2018 | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 80/80x2 V3(1 speed) | 230 | Inline | centrifugal | 80 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | 0.32 | - | 50 | 1400 | - | 88 | Exhaust, Supply | 3.1 | 20 | 50 | C | IPX4 | - | 32 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 24 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 80/80x2 V3(2 speed) | 230 | Inline | centrifugal | 80 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | 0.34 | - | 50 | 1800 | - | 130 | Exhaust, Supply | 3.1 | 26 | 50 | C | IPX4 | - | 35 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 36 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 80/80x2 V3(3 speed) | 230 | Inline | centrifugal | 80 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | 0.4 | - | 50 | 2600 | - | 162 | Exhaust, Supply | 3.1 | 45 | 50 | C | IPX4 | - | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauAIR CFH 1200 | 200-240 | floor mounting, outdoor mounting | - | - | for round air ducts | - | - | aluzinc | yes | yes | yes | - | - | - | 1200 | 50/60 | 3000 | - | - | Supply and exhaust | - | 2x610 | - | - | IP34 | 1 | 35 | - | - | - | - | B | - | - | - | - | - | - | - | -25...+40 | - | - | - | - | - | - | - | - | - | - | - | - | 230 | - | - | ePM1 ≥ 50% (ISO 16890) | F7 (EN 779) | - | - | IP54 | - | - | - | 5.3 | - | - | - | - | - | - | - | - | - | - | - | - | - | -35...+50 | - | - |
KOMFORT Ultra L 250-H S1 white | 230 | wall mounting, floor mounting | - | - | for round air ducts | - | - | - | no | no | yes | - | - | - | 250 | 50/60 | - | - | - | Supply and exhaust | - | 148 | - | E | - | 1 | 28...47 | - | - | cross-flow | polystyrene | - | - | - | 0.78 | 125 | - | - | - | -25...+40 | - | - | 20 mm mineral wool | 55...78 | - | - | - | - | - | - | 69 | - | - | 2018 | - | G4 | G4 (option: F8 PM2.5 > 81 %) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-F 100x50 8D | 400 | Inline | centrifugal | - | for rectangular air ducts | 1000 | 500 | galvanized steel | no | no | no | - | - | 4.1 | 7175 | 50 | 680 | - | - | Exhaust, Supply | - | 2000 | -20...+40 | - | IPX4 | 3 | 59 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1993 | - | 95.0 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Vento Eco A30-4 S11 Pro (1 Speed) |
100-240 | wall mounting | - | - | 100 | - | - | - | yes | - | - | - | - | 0.021 | - | 50/60 | 1600 | I | - | - | - | 1.03 | - | - | IP24 | - | - | - | - | - | - | - | - | - | - | - | 10 | 5 | - | -20...+40 | 42 | - | - | ≤81 | - | - | - | - | - | - | - | 0.74 | - | - | - | - | - | 3 | 1 | - | - | - | - | - | - | - | - | - | 30 | 21 | Sensor | Filter replacement indication, Timer, External sensor connection | D1 | - | - | - | - | - | - | - |
Vento Eco A30-4 S11 Pro (2 Speed) |
100-240 | wall mounting | - | - | 100 | - | - | - | yes | - | - | - | - | 0.027 | - | 50/60 | 2200 | II | - | - | - | 1.96 | - | - | IP24 | - | - | - | - | - | - | - | - | - | - | - | 20 | 10 | - | -20...+40 | 42 | - | - | ≤81 | - | - | - | - | - | - | - | 0,71 | - | - | - | - | - | 6 | 3 | - | - | - | - | - | - | - | - | - | 37 | 28 | Sensor | Filter replacement indication, Timer, External sensor connection | D1 | - | - | - | - | - | - | - |
Vento Eco A30-4 S11 Pro (3 Speed) |
100-240 | wall mounting | - | - | 100 | - | - | - | yes | - | - | - | - | 0.038 | - | 50/60 | 2500 | III | - | - | - | 3.47 | - | - | IP24 | - | - | - | - | - | - | - | - | - | - | - | 30 | 15 | - | -20...+40 | 42 | - | - | ≤81 | - | - | - | - | - | - | - | 0.83 | - | - | - | - | - | 8 | 4 | - | - | - | - | - | - | - | - | - | 40 | 31 | Sensor | Filter replacement indication, Timer, External sensor connection | D1 | - | - | - | - | - | - | - |
BLAUBOX MW 3200-4 Pro | 400 (Y) | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for rectangular air ducts | - | - | aluzinc | no | no | yes | - | - | - | 3250 | 50 | 1200 | - | - | Supply | - | - | - | - | - | 3 | 53 | - | - | - | - | - | -40...+45 | - | 2.3 | - | - | - | 600х350 | - | - | 4 | 25 mm mineral wool | - | 1270 | - | - | - | - | - | 903 | - | 73.1 | 2016, 2018 | - | - | G4 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 550 4Е 50 Hz |
230 | wall mounting | axial | 550 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | 8800 | 50 | 1300 | - | - | Exhaust, Supply | - | 550 | - | - | IPX4 | 1 | 62 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | - | - | 2445 | - | 16.5 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | 2.55 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Axis-Q 550 4Е 60 Hz |
230 | wall mounting | axial | 550 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | 8970 | 60 | 1580 | - | - | Exhaust, Supply | - | 654 | - | - | IPX4 | 1 | 63 | - | - | - | - | - | - | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | - | - | 2492 | - | 16.5 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | 2.88 | - | - | - | - | - | - | - | - | - | - | - | - | - |
CIVIC EC LB 500 S21 V.2 | 230 | floor mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | 580 | 50/60 | - | - | - | Supply and exhaust | 139 | - | - | A | - | - | 38 | - | - | counter-flow | polystyrene | - | -25...+40 | - | - | 250 | - | - | - | - | - | - | 40 mm mineral wool | 75...94* | - | 47 | - | 370 | - | - | 161 | - | - | - | - | - | - | - | - | - | - | - | 2.5 | - | - | - | - | - | - | - | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - | - |
Freshbox E-100 ERV black Speed I |
230 | wall mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | electric preheating | - | - | 30 | 50/60 | 2200 | I | - | - | 31 | - | - | A | - | 1 | - | - | - | counter-flow | enthalpy | - | - | - | - | 100 | - | - | - | -20...+40 | - | - | - | 90 | - | - | - | - | - | 10 | 8 | - | - | - | - | G4 | G4, F8 (Option: F8 C, H13) | - | - | - | 12 | - | 0.4 | - | - | 3.6 | - | 700 | - | 13 | LCD | Filter replacement indication, Timer, Weekly schedule | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - | - |
Freshbox E-100 ERV black Speed II |
230 | wall mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | electric preheating | - | - | 60 | 50/60 | 2200 | II | - | - | 31 | - | - | A | - | 1 | - | - | - | counter-flow | enthalpy | - | - | - | - | 100 | - | - | - | -20...+40 | - | - | - | 86 | - | - | - | - | - | 10 | 17 | - | - | - | - | G4 | G4, F8 (Option: F8 C, H13) | - | - | - | 21 | - | 0.4 | - | - | 3.6 | - | 700 | - | 27 | LCD | Filter replacement indication, Timer, Weekly schedule | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - | - |
Freshbox E-100 ERV black Speed III |
230 | wall mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | electric preheating | - | - | 100 | 50/60 | 2200 | III | - | - | 31 | - | - | A | - | 1 | - | - | - | counter-flow | enthalpy | - | - | - | - | 100 | - | - | - | -20...+40 | - | - | - | 83 | - | - | - | - | - | 10 | 28 | - | - | - | - | G4 | G4, F8 (Option: F8 C, H13) | - | - | - | 45 | - | 0.4 | - | - | 3.6 | - | 700 | - | 39 | LCD | Filter replacement indication, Timer, Weekly schedule | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - | - | - |