Selected 1357 products
Mode Transported air temperatureHeat recovery efficiencySound pressure level at 3 mCasing materialWeightConnected air duct diameterHeat exchanger typeHeat exchanger materialExtract filterSupply filterVoltagePhaseFrequencyMax. unit currentMaximum power consumption in "Heat Recovery + Heat Pump"Maximum power consumption in "Heat Recovery"Air-handling unit energy efficiency "Heating" mode (COP)Air-handling unit energy efficiency "Cooling" mode (ERR)CoolantCoolant weightHeat output in "Heating" mode [kW] at t0 = +7 °C; tk = +45 °C*Compressor typeTemperature setting range in "Cooling/Heating"Heat output in "Cooling" mode [W] at t0 = +7 °C; tk = +45 °CMaximum air flowMaximum air flowPowerCurrentRPMIngress protection ratingMotor IP ratingErPEC motorMountingConnection diameterSEC classOutdoor mountingAir ductSound-insulated casingTypeInsulation classPerm. amb. temp.
KOMFORT Roto EC LHP 700 S17 -10…+40 85 52 aluzinc 160 250 rotary aluminum G4 G4 (Option: F7) 230 1 50 5.7 0.94 0.36 6.5 4.15 R410A 1.0 2.6 Sealed, rotary type +16...+30 2 231 830 - - - - - - - - - - - - - - - -
KOMFORT Roto EC LHP 700 S18 -10…+40 85 52 aluzinc 160 250 rotary aluminum G4 G4 (Option: F7) 230 1 50 5.7 0.94 0.36 6.5 4.15 R410A 1.0 2.6 Sealed, rotary type +16...+30 2 231 830 - - - - - - - - - - - - - - - -
KOMFORT Roto EC LHP 900 S17 -10…+40 85 58 aluzinc 165 250 rotary aluminum G4 G4 (Option: F7) 230 1 50 6.7 1.195 0.46 6.5 4.25 R410A 2 3.25 Sealed, rotary type +16...+30 2.5 265 955 - - - - - - - - - - - - - - - -
KOMFORT Roto EC LHP 900 S18 -10…+40 85 58 aluzinc 165 250 rotary aluminum G4 G4 (Option: F7) 230 1 50 6.7 1.195 0.46 6.5 4.25 R410A 2 3.25 Sealed, rotary type +16...+30 2.5 265 955 - - - - - - - - - - - - - - - -
Iso-Mix EC 100 -25...+55 - 37 polymer-coated steel 4.6 - - - - - 230 1 50 - - - - - - - - - - - 83 300 30 0.29 3680 IPX4 - 2018 yes ceiling mounting, wall mounting, floor mounting 100 B - - - - - -
Iso-Mix EC 125 -25...+55 - 43 polymer-coated steel 4.6 - - - - - 230 1 50 - - - - - - - - - - - 125 450 40 0.37 3750 IPX4 - 2018 yes ceiling mounting, wall mounting, floor mounting 125 B - - - - - -
Iso-Mix EC 150 -25...+55 - 38 polymer-coated steel 6.1 - - - - - 230 1 50 - - - - - - - - - - - 167 600 55 0.48 3390 IPX4 - 2018 yes ceiling mounting, wall mounting, floor mounting 150 B - - - - - -
Iso-Mix EC 160 -25...+55 - 38 polymer-coated steel 6.3 - - - - - 230 1 50 - - - - - - - - - - - 167 600 55 0.48 3390 IPX4 - 2018 yes ceiling mounting, wall mounting, floor mounting 160 B - - - - - -
Iso-Mix EC 200 -25...+55 - 43 polymer-coated steel 8 - - - - - 230 1 50 - - - - - - - - - - - 289 1040 123 1.02 3390 IPX4 - 2018 yes ceiling mounting, wall mounting, floor mounting 200 - - - - - -
Iso-Mix EC 250 -25...+55 - 42 polymer-coated steel 15 - - - - - 230 1 50 - - - - - - - - - - - 357 1285 169 1.38 2870 IPX4 - 2018 yes ceiling mounting, wall mounting, floor mounting 250 - - - - - -
BlauAIR CFH 1200 -25...+40 - 35 aluzinc 230 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 200-240 1 50/60 5.3 - - - - - - - - - - - 1200 2x610 - 3000 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for round air ducts yes Supply and exhaust B -35...+50
BlauAIR CFV 3500 -25...+40 - 34 aluzinc 515 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 380-480 3 50/60 3.6 - - - - - - - - - - - 3500 2x1150 - 2400 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFV 2500 -25...+40 - 30 aluzinc 307 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 200-240 1 50/60 6.8 - - - - - - - - - - - 2500 2x750 - 3000 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFV 1500 -25...+40 - 28 aluzinc 307 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 200-240 1 50/60 4.8 - - - - - - - - - - - 1500 2x530 - 3000 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFH 9000 -25...+40 - 32 aluzinc 1400 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 380-480 3 50/60 8.5 - - - - - - - - - - - 9000 2x2650 - 1700 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFH 800 -25...+40 - 34 aluzinc 230 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 200-240 1 50/60 2.5 - - - - - - - - - - - 800 2x270 - 2800 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for round air ducts yes Supply and exhaust B -35...+50
BlauAIR CFH 6000 -25...+40 - 32 aluzinc 628 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 380-480 3 50/60 8.5 - - - - - - - - - - - 6000 2x2650 - 1700 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFH 5000 -25...+40 - 39 aluzinc 628 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 380-480 3 50/60 4.25 - - - - - - - - - - - 5000 2x1330 - 1350 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFH 3500 -25...+40 - 35 aluzinc 420 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 380-480 3 50/60 3.6 - - - - - - - - - - - 3500 2x1150 - 2400 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFH 2500 -25...+40 - 37 aluzinc 295 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 200-240 1 50/60 6.9 - - - - - - - - - - - 2500 2x835 - 3000 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFH 1500 -25...+40 - 37 aluzinc 295 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 200-240 1 50/60 5.3 - - - - - - - - - - - 1500 2x610 - 3000 IP34 IP54 - yes floor mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFP 1000 -25...+40 - 35 aluzinc 120 - - - ePM1 55% ePM1 55% (ISO 16890)-F7 (EN779) 200-240 1 50/60 2.3 - - - - - - - - - - - 1000 2x230 - 3200 IP34 IP54 - yes ceiling mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust F -35...+50
BlauAIR CFP 2500 -25...+40 - 34 aluzinc 290 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 200-240 1 50/60 3.75 - - - - - - - - - - - 2500 2x740 - 2640 IP34 IP54 - yes ceiling mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFP 1500 -25...+40 - 32 aluzinc 270 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 200-240 1 50/60 3.0 - - - - - - - - - - - 1500 2x460 - 2848 IP34 IP54 - yes ceiling mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
BlauAIR CFP 3500 -25...+40 - 35 aluzinc 320 - - - ePM1 ≥ 50% (ISO 16890) F7 (EN 779) 380-480 3 50/60 1.8 - - - - - - - - - - - 3500 2x1140 - 2400 IP34 IP54 - yes ceiling mounting, outdoor mounting - - yes for rectangular air ducts yes Supply and exhaust B -35...+50
Pages