Selected 1021 products
Mode VoltageStyleMountingDesignConnection diameterAir ductWidthHeightCasing materialEC motorOutdoor mountingSound-insulated casingHeatingFormLengthMaterialDeviceCurrentPowerMaximum air flowSound pressure levelFrequencyRPMSpeedHeat recovery efficiencyMaximum air capacityTypeWeight PowerMax. operating temperatureSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialElectric heater powerTransported air temperature Electric heater currentCurrentConnected air duct diameterTransported air temperatureInsulationHeat recovery efficiencyTotal unit powerSound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionInsulation thiknessMaximum air flowSFPWeightErPExtract filterSupply filterMotor IP ratingPM 2.5 RatioMax. power without electric heaterMax. unit current without electric heaterMax. unit power with electric heaterMax. unit current with electric heaterCurrentPreheater power consumptionSound pressure level at 3 m in accordance with ISO 3741:2004Electric heater current Remote control panelFunctions*Motor max. power**
Extero 100
50 Hz
230 - Inline centrifugal 100 for round air ducts - - polymer-coated steel no yes no - - - - - 0.31 - 325 - 50 2530 - - - Exhaust - 71 +55 C IPX4 1 54 - - - - - - - - - - - - - - - - 90 - 4.1 2018 - - IP44 - - - - - - - - - - - - - -
Extero 100
60 Hz
230 - Inline centrifugal 100 for round air ducts - - polymer-coated steel no yes no - - - - - 0.40 - 350 - 60 2625 - - - Exhaust - 92 +55 C IPX4 1 54 - - - - - - - - - - - - - - - - 97 - 4.1 2018 - - IP44 - - - - - - - - - - - - - -
Trio One 100 - White ceiling mounting, wall mounting axial 100 - - - - - - - - - - - - 0.05 8 95 27 50 - - - - Exhaust - - - - - - - - - - - - - - - - - - - 220-240 - - - 26 0.3 0.45 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
KOMFORT Roto EC LE 700-3.3 S17 230 - - - - - - - aluzinc - - - - - - - - - - 700 - 50/60 2600 - - - - - - - A - 1 52 rotary aluminum 3300 - - - 250 -25...+40 20 mm mineral wool 76–95 - - - - - - 194 - 128 2016, 2018 G4 G4 - - - - 3615 15.8 - - - - - - - 2 items x 105 -
Iso-ZS 250 6E max 230 - - centrifugal - for round air ducts - - galvanized steel no no yes - - - - - 1.36 - - - 50 940 - - 1680 Exhaust, Supply 31.3 311 -20…+50 - IPX4 1 41 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Aero 100 220-240 White ceiling mounting, wall mounting axial 100 - - - - - - - - - - - - 0.085 14 102 38* 50 2300 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - 28 0.49 - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Freshbox 100 ERV black
Speed I
110-240 - wall mounting - - - - - polymer-coated steel yes - - without heating - - - - - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow enthalpy - - - - 100 -20...+40 - 96 - - - - - 10 8 - - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 - - - - 13 - LCD Filter replacement indication, Timer, Weekly schedule Heat recovery efficiency is specified in compliance with EN 13141-8 - -
Freshbox 100 ERV black
Speed II
110-240 - wall mounting - - - - - polymer-coated steel yes - - without heating - - - - - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow enthalpy - - - - 100 -20...+40 - 89 - - - - - 10 17 - - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 - - - - 27 - LCD Filter replacement indication, Timer, Weekly schedule Heat recovery efficiency is specified in compliance with EN 13141-8 - -
Freshbox 100 ERV black
Speed III
110-240 - wall mounting - - - - - polymer-coated steel yes - - without heating - - - - - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow enthalpy - - - - 100 -20...+40 - 83 - - - - - 10 28 - - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 - - - - 39 - LCD Filter replacement indication, Timer, Weekly schedule Heat recovery efficiency is specified in compliance with EN 13141-8 - -
Tower-H 280 4E (50 Hz) 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - - - - - 0.61 - 1490 - 50 1446 - - - Exhaust 13.5 125 -25…+50 IPX4 1 46 - - - - - - - - - - - - - - - - 414 - - 2018 - - IP44 - - - - - - - - - - - - - -
Tower-H 280 4E (60 Hz) 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - - - - - 0.99 - 1520 - 60 1710 - - - Exhaust 13.5 155 -25…+50 IPX4 1 46 - - - - - - - - - - - - - - - - 422 - - - - IP44 - - - - - - - - - - - - - -
Quatro Hi-Tech Chrome 100 (127-220V/60Hz) 127 Hi-Tech Chrome ceiling mounting, wall mounting axial 100 - - - - - - - - - - - - 0.115 10 82 33* 60 2500 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - 23 0.44 - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Quatro Hi-Tech Chrome 100 (127-220V/60Hz) 220 Hi-Tech Chrome ceiling mounting, wall mounting axial 100 - - - - - - - - - - - - 0.054 9 82 33* 60 2500 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - 23 0.40 - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Ceileo 250 (50 Hz, min) 230 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.12 23 170 25* 50 756 min - - Exhaust - - - - IPX2 - - - - - - - - - - - - - - - - - - 47 0.49 5.3 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Ceileo 250 (50 Hz, max) 230 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.18 39 260 29* 50 1122 max - - Exhaust - - - - IPX2 - - - - - - - - - - - - - - - - - - 72 0.54 5.3 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Ceileo 250 (60 Hz, min) 230 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.14 25 160 25* 60 732 min - - Exhaust - - - - IPX2 - - - - - - - - - - - - - - - - - - 44 0.56 5.3 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Ceileo 250 (60 Hz, max) 230 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.22 50 270 30* 60 1140 max - - Exhaust - - - - IPX2 - - - - - - - - - - - - - - - - - - 75 0.67 5.3 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
S-Vent 140х74-0.25-4D 400 - floor mounting centrifugal - for rectangular air ducts, for round air ducts - - polymer-coated steel no yes no - - - - - 0.8 - 450 - 50 1350 - - - Exhaust, Supply 9.3 250 +60 D IP54 3 60 - - - - - - - - - - - - - - - - 125 - - 2018 - - IP54 - - - - - - - - - - - - - -
Centro-MZ 315 L
50 Hz
220-240 - ceiling mounting, wall mounting centrifugal 315 for round air ducts - - galvanized steel no no no - - - - - 0.66 - 1330 - 50 2680 - - - Supply and exhaust 6.57 151 - - IPX4 1 52 - - - - - - - -25...+50 - - - - - - - - 369 - - 2018 - - IP44 - - - - - - - - - - - - - -
Centro-MZ 315 L
60 Hz
220-240 - ceiling mounting, wall mounting centrifugal 315 for round air ducts - - galvanized steel no no no - - - - - 0.89 - 1370 - 60 2750 - - - Supply and exhaust 6.57 205 - - IPX4 1 52 - - - - - - - -25...+50 - - - - - - - - 381 - - 2018 - - IP44 - - - - - - - - - - - - - -
CIVIC EC DB 1000 S21 V.2 230 - ceiling mounting - - - - - polymer-coated steel yes - - without heating - - - - - - 1000 - 50/60 - - - - Supply and exhaust 252 - - A+ - 1 24 counter-flow polystyrene - -25...+40 - - 315 - - 83…93* - 34 - 267 - - 278 - - - - - - - - 1.85 - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 - -
KOMFORT LE 1700-18 400 - ceiling mounting, wall mounting, floor mounting - - - - - aluzinc - - - - - - - - - - 1750 - 50/60 1100 - 77 - - - - - NRVU - 3 49 cross-flow polystyrene 18000 - 26 30.3 315 -25...+40 25 mm mineral wool - 18980 - - - - - 486 - 96 - G4 G4 - - 980 4.3 - - - - - - - - - - -
Box-F 100x50 8D 400 - Inline centrifugal - for rectangular air ducts 1000 500 galvanized steel no no no - - - - - 4.1 - 7175 - 50 680 - - - Exhaust, Supply - 2000 -20...+40 - IPX4 3 59 - - - - - - - - - - - - - - - - 1993 - 95.0 - - - IP44 - - - - - - - - - - - - - -
BlauPlast RR 200/0.35 - - - - 200 - - - - - - - - round 350 PVC (plastic) air duct - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axis-QR 200 2Е
50 Hz
230 - wall mounting axial 200 for round air ducts - - polymer-coated steel no no no - - - - - - - 860 - 50 2300 - - - Exhaust, Supply - 55 - - IPX4 1 48 - - - - - - - -30...+60 - - - - - - - - 239 - 2.8 - - - IP24 - - - - - 0.26 - - - - - - - -
Axis-QR 200 2Е
60 Hz
230 - wall mounting axial 200 for round air ducts - - polymer-coated steel no no no - - - - - - - 875 - 60 2550 - - - Exhaust, Supply - 61 - - IPX4 1 49 - - - - - - - -30...+50 - - - - - - - - 243 - 2.8 - - - IP24 - - - - - 0.28 - - - - - - - -
Bravo Platinum 150 (127-220V/60Hz) 127 Platinum ceiling mounting, wall mounting axial 150 - - - - - - - - - - - - 0.175 25 266 38* 60 2350 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - 74 0.34 - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Bravo Platinum 150 (127-220V/60Hz) 220 Platinum ceiling mounting, wall mounting axial 150 - - - - - - - - - - - - 0.338 25 266 38* 60 2350 - - - Exhaust - - - - - - - - - - - - - - - - - - - - - - - 74 0.34 - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Iso Box-F 100 G4-H13 230 - ceiling mounting, wall mounting centrifugal 100 for round air ducts - - polymer-coated steel no no yes - - - - - 0.27 - 170 - 50/60 1300 - - - Supply 14.16 52 - D IPX4 1 23 - - - - - - - -25…+40 - - - - - - - - 47 - - 2018 - - - 98 - - - - - - - - - - - - -
KOMFORT EC DE 2000-12 R 400 - ceiling mounting - - - - - aluzinc - - - - - - - - - - 2000 - 50/60 2920 - - - - - - - NRVU - 3 58 cross-flow aluminum 12000 - - - 315 -25…+40 25 mm mineral wool 75 - - - - - - 556 - 190 2016 G4 G4 - - 840 5 12870 22.4 - - - 17.4 - - - - -
KOMFORT EC DE 4000-21 R 400 - ceiling mounting - - - - - aluzinc - - - - - - - - - - 4000 - 50/60 2580 - - - - - - - NRVU - 3 59 cross-flow aluminum 21000 - - - 400 -25…+40 25 mm mineral wool 75 - - - - - - 1111 - 290 2016 G4 G4 - - 1980 3.4 23000 33.4 - - - 30.0 - - - - -
S-Vent 250х127-5.5-2D 400 - floor mounting centrifugal - for rectangular air ducts, for round air ducts - - polymer-coated steel no yes no - - - - - 10.7 - 4820 - 50 2850 - - - Exhaust, Supply 40 5500 +60 - IP54 3 81 - - - - - - - - - - - - - - - - 1339 - - - - - IP54 - - - - - - - - - - - - - -