Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Form | Length | Material | Device | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Cable cross section | Transported air temperature | Current | Connected air duct size | Filter | Transported air temperature | Number of water coil rows | Sectional size | Insulation | Total unit power | Voltage | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Maximum air flow | Supply filter | Motor IP rating | Max. unit power | Max. unit current | Current | * | *** | Max. water temperature | Water coil connection diameter |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Iso-ZS 315/2x250 4E | 230 | - | - | centrifugal | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | - | - | - | 3.36 | - | - | - | 50 | 1390 | - | 3420 | Exhaust, Supply | 33.0 | 764 | -20…+50 | - | IPX4 | 1 | 45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | – | - | - | - | - | - | - | - | - | - | - | - |
Box-I 60x35 4E 50 Hz |
230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | 2.37 | - | 2950 | - | 50 | 1370 | - | - | Exhaust, Supply | 56.2 | 470 | - | - | IPX4 | 1 | 47 | - | - | - | - | - | -40…+80 | - | - | - | - | - | 820 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - |
Box-I 60x35 4E 60 Hz |
230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | 3.15 | - | 3515 | - | 60 | 1460 | - | - | Exhaust, Supply | 56.2 | 700 | - | - | IPX4 | 1 | 47 | - | - | - | - | - | -40…+55 | - | - | - | - | - | 976 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - |
Axis-QR 300 2D 50 Hz |
400 | - | wall mounting | axial | 300 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | 2310 | - | 50 | 2350 | - | - | Exhaust, Supply | - | 145 | - | - | IPX4 | 3 | 52 | - | - | - | - | - | -30...+60 | - | - | - | - | - | 642 | - | 5.1 | - | - | - | - | IP44 | - | - | 0.25 | - | - | - | - |
Axis-QR 300 2D 60 Hz |
400 | - | wall mounting | axial | 300 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | 2390 | - | 60 | 2570 | - | - | Exhaust, Supply | - | 165 | - | - | IPX4 | 3 | 52 | - | - | - | - | - | -30...+50 | - | - | - | - | - | 664 | - | 5.1 | - | - | - | - | IP44 | - | - | 0.29 | - | - | - | - |
Slim 100 | 220-240 | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.085 | 14 | 105 | 33* | 50 | 2300 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 29 | 0.48 | 0.6 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - |
Box-FI 40x20 4E | 230 | - | Inline | centrifugal | - | for rectangular air ducts | 400 | 200 | galvanized steel | no | no | yes | - | - | - | - | 1.32 | - | 1440 | - | 50 | 1350 | - | - | Exhaust, Supply | - | 295 | - | - | IPX4 | 1 | 42 | - | - | - | - | - | -25...+40 | - | - | - | - | - | 400 | - | 29 | - | - | - | - | IP44 | - | - | - | - | - | - | - |
Axis-F 800 6D | 400 | - | Inline | axial | 800 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | 25000 | - | 50 | 915 | - | - | Exhaust, Supply | - | 1850 | - | - | IPX4 | 3 | 67 | - | - | - | - | - | -30...+60 | - | - | - | - | - | 6945 | - | 40.0 | - | - | - | - | IP44 | - | - | 3.7 | - | - | - | - |
Aero Still Gold 150 | 220-240 | Gold | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.14 | 19 | 254 | 33* | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 71 | 0.27 | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - |
Blaubox EC MW 3000 S31 | 230 | - | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for rectangular air ducts | - | - | aluzinc | yes | no | - | - | - | - | - | - | - | 2930 | - | 50 | - | - | - | Supply | - | - | - | - | - | 1 | 52 | - | -30…+40 | - | 600 × 300 | Coarce 90% / G4 (option: ePM1 70% / F7) | - | 4 | - | 30 mm mineral wool | - | - | - | - | 50 | 2018 | - | - | - | - | 0.425 | 1.8 | - | - | - | 150 | 1 1/8` |
BLAUBOX MW 3000-4 Pro | 400 (Y) | - | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for rectangular air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | - | - | 3000 | - | 50 | 1200 | - | - | Exhaust | - | - | - | - | - | 3 | 53 | - | -40...+45 | 2.3 | 600х300 | - | - | 4 | - | 25 mm mineral wool | 1270 | - | 833 | - | 73.2 | 2016, 2018 | - | - | G4 | - | - | - | - | - | - | - | - |
Tubo 150 | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 30 | 295 | 40* | 50 | 2400 | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 82 | 0.37 | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - |
BlauPlast RVPK 125 | - | - | - | - | 125 | for round air ducts | - | - | - | - | - | - | round | - | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box EC 50x25-1 | 230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | yes | no | - | - | - | - | - | - | - | 1590 | - | 50/60 | 2500 | - | - | Exhaust, Supply | 15.7 | 252 | - | – | IPX4 | - | 45 | - | - | - | - | - | -25...+50 | - | - | - | - | - | 442 | - | - | 2018 | 1590 | 442 | - | IP54 | - | - | 1.85 | - | - | - | - |
BlauPlast FKVK 110x55 | - | - | - | - | - | for rectangular air ducts | - | - | - | - | - | - | rectangular | - | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 55х110 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-K 450 6E | 230 | - | Inline | centrifugal | 450 | for round air ducts | - | - | galvanized steel | no | yes | yes | - | - | - | - | 2.85 | - | - | - | 50 | 970 | - | 5299 | Exhaust | - | 594 | -20…+120 | - | IP54 | 1 | 50 | - | - | - | - | - | - | - | - | - | - | - | - | - | 105 | - | - | 1472 | - | IP54 | - | - | - | - | - | - | - |
Ducto 150 | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.095 | 22 | 340 | 39* | 50 | 2250 | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 94 | 0.23 | 1.3 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - |
Iso-VK 500 4E | 230 | - | Inline | centrifugal | 500 | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | 10.6 | - | 9100 | - | 50 | 1410 | - | - | Exhaust | 96.3 | 1500 | –25…+120 | – | IPX4 | 1 | 57 | - | - | - | - | - | - | - | - | - | - | - | 2528 | - | - | - | - | - | - | IP55 | - | - | - | - | - | - | - |
Valeo-BF 100 (1 speed) |
220-240 | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.13 | - | 100 | - | 50 | - | I | - | Exhaust | - | 29 | +50 | - | IP55 | - | 38 | 3x1.5 | - | - | - | - | - | - | - | - | - | - | 28 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Quatro Platinum 150 (127-220V/60Hz) | 127 | Platinum | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.175 | 25 | 240 | 37* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 67 | 0.37 | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - |
Quatro Platinum 150 (127-220V/60Hz) | 220 | Platinum | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.338 | 25 | 240 | 37* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 67 | 0.37 | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - |
BlauPlast FK 220×90/1.5 | - | - | - | - | - | - | - | - | - | - | - | - | rectangular | 1500 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 90х220 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-R 150 V2 (1 speed) | 1 ~ 230 | - | Inline | centrifugal | 150 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.43 | - | - | - | 50 | 750 | - | 356 | Exhaust, Supply | 7.7 | 98 | 50 | C | IPX4 | - | 45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 99 | - | - | - | - | - | - | - | - | - |
Box-R 150 V2 (2 speed) | 1 ~ 230 | - | Inline | centrifugal | 150 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.56 | - | - | - | 50 | 870 | - | 533 | Exhaust, Supply | 7.7 | 122 | 50 | C | IPX4 | - | 46 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 148 | - | - | - | - | - | - | - | - | - |
Ceileo 250 T (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.12 | 23 | 170 | 25* | 50 | 756 | min | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | - | 47 | 0.49 | 5.3 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors | - | - |
Ceileo 250 T (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.18 | 39 | 260 | 29* | 50 | 1122 | max | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | - | 72 | 0.54 | 5.3 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors | - | - |
Ceileo 250 T (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.14 | 25 | 160 | 25* | 60 | 732 | min | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | - | 44 | 0.56 | 5.3 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors | - | - |
Ceileo 250 T (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.22 | 50 | 270 | 30* | 60 | 1140 | max | - | Exhaust | - | - | - | C*** | IPX2 | - | - | - | - | - | - | - | - | - | - | - | - | - | 75 | 0.67 | 5.3 | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors | - | - |
Iso-ZS 250 6E max | 230 | - | - | centrifugal | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | - | - | - | 1.36 | - | - | - | 50 | 940 | - | 1680 | Exhaust, Supply | 31.3 | 311 | -20…+50 | - | IPX4 | 1 | 41 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | – | - | - | - | - | - | - | - | - | - | - | - |
Box-I 50x25 2E 50 Hz |
230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | 1.32 | - | 1720 | - | 50 | 2550 | - | - | Exhaust, Supply | 27.6 | 305 | - | - | IPX4 | 1 | 51 | - | - | - | - | - | -25…+45 | - | - | - | - | - | 478 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - |
Box-I 50x25 2E 60 Hz |
230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | 1.65 | - | 1850 | - | 60 | 2830 | - | - | Exhaust, Supply | 27.6 | 380 | - | - | IPX4 | 1 | 52 | - | - | - | - | - | -25…+45 | - | - | - | - | - | 514 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - |
Axis-QR 500 4Е 50 Hz |
230 | - | wall mounting | axial | 500 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | 7060 | - | 50 | 1300 | - | - | Exhaust, Supply | - | 420 | - | - | IPX4 | 1 | 58 | - | - | - | - | - | -30...+60 | - | - | - | - | - | 1961 | - | 14.0 | - | - | - | - | IP24 | - | - | 1.95 | - | - | - | - |
Axis-QR 500 4Е 60 Hz |
220 | - | wall mounting | axial | 500 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | 7130 | - | 60 | 1630 | - | - | Exhaust, Supply | - | 455 | - | - | IPX4 | 1 | 59 | - | - | - | - | - | -30...+50 | - | - | - | - | - | 1981 | - | 14.0 | - | - | - | - | IP24 | - | - | 2.05 | - | - | - | - |
Bravo Chrome 125 (127-220V/60Hz) | 127 | Chrome | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.119 | 16 | 189 | 34* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 53 | 0.3 | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - |
Bravo Chrome 125 (127-220V/60Hz) | 220 | Chrome | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.102 | 15 | 189 | 34* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 53 | 0.29 | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - | - |