Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Print version
Search results
Selected 1048 products
Mode SpeedWeight FrequencyVoltagePhaseSound-insulated casingEC motorCasing materialAir ductDesignOutdoor mountingMountingTypeErPMotor IP ratingIngress protection ratingTransported air temperatureSound pressure level at 3 mRPMMaximum air flowMaximum air flowPowerCurrentPowerPowerMax. operating temperatureSpigotSEC classTransported air temperature Connected air duct diameterMax. unit power without an electric heaterPreheater power consumptionReheater power consumptionMax. unit current without electric heaterMax. unit current with electric heaterExtract filterSupply filterHeat exchanger typeHeat exchanger materialHeat recovery efficiencyInsulationHeatingRemote control panelFunctions*Sound pressure level at a distance of 1 m
min min 9.8 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 38 2292 1007 280 144 0.70 - - - - - - - - - - - - - - - - - - - - - - -
mid med 9.8 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 43 2626 1404 390 173 0.81 - - - - - - - - - - - - - - - - - - - - - - -
max max 9.8 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 45 2876 1670 464 188 0.84 - - - - - - - - - - - - - - - - - - - - - - -
min min 20.7 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 33 1350 1913 531 126 0.60 - - - - - - - - - - - - - - - - - - - - - - -
mid med 20.7 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 34 1400 2120 589 131 0.58 - - - - - - - - - - - - - - - - - - - - - - -
max max 20.7 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 36 1470 2300 639 148 0.66 - - - - - - - - - - - - - - - - - - - - - - -
min min 20.7 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 33 1350 1986 552 126 0.60 - - - - - - - - - - - - - - - - - - - - - - -
mid med 20.7 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 34 1400 2170 603 131 0.58 - - - - - - - - - - - - - - - - - - - - - - -
max max 20.7 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 36 1470 2360 656 150 0.66 - - - - - - - - - - - - - - - - - - - - - - -
min min 22.8 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 34 1320 2543 706 197 0.91 - - - - - - - - - - - - - - - - - - - - - - -
mid med 22.8 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 35 1390 2979 828 204 0.90 - - - - - - - - - - - - - - - - - - - - - - -
max max 22.8 50 230 1 yes no galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP20 IPX4 -25...+55 37 1446 3185 885 224 0.98 - - - - - - - - - - - - - - - - - - - - - - -
Iso-Primo EC 200 - 8.2 50 230 1 yes yes galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP44 IPX4 -25...+55 47 3100 1210 336 - 0.96 121 - - - - - - - - - - - - - - - - - - - - - -
Iso-Primo EC 250 - 9.8 50 230 1 yes yes galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP44 IPX4 -25...+55 48 3282 1750 486 - 1.34 - 168 - - - - - - - - - - - - - - - - - - - - -
Iso-Primo EC 315 - 20.7 50/60 230 1 yes yes galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP44 IPX4 -25...+55 47 2470 3090 858 - 1.56 - 353 - - - - - - - - - - - - - - - - - - - - -
Iso-Primo EC 355 - 20.7 50/60 230 1 yes yes galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP44 IPX4 -25...+55 48 2470 3500 972 - 1.56 - 353 - - - - - - - - - - - - - - - - - - - - -
Iso-Primo EC 400 - 22.8 50/60 230 1 yes yes galvanized steel for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP44 IPX4 -25...+55 - 2580 5415 1504 - 4.80 - 726 - - - - - - - - - - - - - - - - - - - - -
inWave 100/125
50 Hz
min speed
min 3.6 50 230 1 yes no plastic for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP44 IPX4 - 16 2252 173 48 9 0.81 - - -25…+55 125 - - - - - - - - - - - - - - - - - - -
inWave 100/125
50 Hz
med speed
med 3.6 50 230 1 yes no plastic for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP44 IPX4 - 21 2662 240 67 13 0.09 - - -25…+55 125 - - - - - - - - - - - - - - - - - - -
inWave 100/125
50 Hz
max speed
max 3.6 50 230 1 yes no plastic for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP44 IPX4 - 25 2810 320 89 21 0.10 - - -25…+55 125 - - - - - - - - - - - - - - - - - - -
inWave 100/125
60 Hz
min speed
min 3.6 60 230 1 yes no plastic for round air ducts mixed-flow no Inline Exhaust, Supply IP44 IPX4 - 16 1894 161 45 10 0.09 - - -25…+55 125 - - - - - - - - - - - - - - - - - - -
inWave 100/125
60 Hz
med speed
med 3.6 60 230 1 yes no plastic for round air ducts mixed-flow no Inline Exhaust, Supply IP44 IPX4 - 21 2402 204 57 13 0.10 - - -25…+55 125 - - - - - - - - - - - - - - - - - - -
inWave 100/125
60 Hz
max speed
max 3.6 60 230 1 yes no plastic for round air ducts mixed-flow no Inline Exhaust, Supply IP44 IPX4 - 25 3242 320 89 26 0.12 - - -25…+55 125 - - - - - - - - - - - - - - - - - - -
inWave 150/160
min
min 5.0 50 230 1 yes no plastic for round air ducts mixed-flow no Inline Exhaust, Supply, Supply and exhaust 2018 IP20 IPX4 - 20 1982 242 67 25 0.20 - - –25…+55 150/160 - - - - - - - - - - - - - - - - - - -
inWave 150/160
med
med 5.0 50 230 1 yes no plastic for round air ducts mixed-flow no Inline Exhaust, Supply, Supply and exhaust 2018 IP20 IPX4 - 26 2374 320 89 46 0.21 - - –25…+55 150/160 - - - - - - - - - - - - - - - - - - -
inWave 150/160
max
max 5.0 50 230 1 yes no plastic for round air ducts mixed-flow no Inline Exhaust, Supply, Supply and exhaust 2018 IP20 IPX4 - 33 2738 540 150 51 0.24 - - –25…+55 150/160 - - - - - - - - - - - - - - - - - - -
inWave EC 100/125 - 3.6 50/60 230 1 yes yes plastic for round air ducts mixed-flow no Inline Exhaust, Supply 2018 IP44 IPX4 - 28 3002 350 97 20 0.77 - - -25…+55 125 - - - - - - - - - - - - - - - - - - -
CIVIC EC LBE 500 S21 V.2 - 140 50/60 230 1 - yes polymer-coated steel - - - floor mounting Supply and exhaust - - - - 38 - 580 161 - - - - - - A -25...+40 250 370 1050 - 2.5 9.1 - - counter-flow polystyrene 75...94* 40 mm mineral wool electric preheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47
CIVIC EC DBE2 300 S21 V.2 - 80 50/60 230 1 - yes polymer-coated steel - - - ceiling mounting Supply and exhaust - - - - 34 - 300 83 - - - - - - A+ -25...+40 200 204 1050 700 1.5 11.7 - - counter-flow polystyrene 83…92* - electric preheating, electric reheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 44
CIVIC EC DBE 300 S21 V.2 - 79 50/60 230 1 - yes polymer-coated steel - - - ceiling mounting Supply and exhaust - - - - 34 - 300 83 - - - - - - A+ -25...+40 200 204 1050 - 1.5 7.7 - - counter-flow polystyrene 83…92* - electric preheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 44
CIVIC EC DB 300 S21 V.2 - 78 50/60 230 1 - yes polymer-coated steel - - - ceiling mounting, wall mounting Supply and exhaust - - - - 34 - 300 83 - - - - - - A+ -25...+40 200 204 - - 1.5 - - - counter-flow polystyrene 83…92* - without heating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 44
CIVIC EC LB 1200 S21 V.2 - 352 50/60 230 1 - yes polymer-coated steel - - - floor mounting Supply and exhaust - - - - 30 - 1240 344 - - - - - - -25...+40 400 345 - - 2.3 - - - counter-flow polystyrene 84…96* 40 mm mineral wool without heating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 40
CIVIC EC LBE 1200 S21 V.2 - 358 50/60 230 3 - yes polymer-coated steel - - - floor mounting Supply and exhaust - - - - 30 - 1240 344 - - - - - - A -25...+40 400 345 3150 - 2.3 12 - - counter-flow polystyrene 84…96* 40 mm mineral wool electric preheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 40
CIVIC EC LBE2 1200 S21 V.2 - 363 50/60 400 3 - yes polymer-coated steel - - - floor mounting Supply and exhaust - - - - 30 - 1240 344 - - - - - - -25...+40 400 345 3150 2110 2.3 18.7 - - counter-flow polystyrene 84…96* 40 mm mineral wool electric preheating, electric reheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 40
CIVIC EC LBE2 500 S21 V.2 - 142 50/60 230 1 - yes polymer-coated steel - - - floor mounting Supply and exhaust - - - - 38 - 580 161 - - - - - - A -25...+40 250 370 1050 700 2.5 13.3 - - counter-flow polystyrene 75...94* 40 mm mineral wool electric preheating, electric reheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47
CIVIC EC LB 300-E S21 V.2 - 100 50/60 230 1 - yes polymer-coated steel - - - floor mounting Supply and exhaust - - - - 37 - 320 89 - - - - - - A -25...+40 200 96 - - 0.75 - - - counter-flow enthalpy 73...89* 40 mm mineral wool without heating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47
CIVIC EC LB 300 S21 V.2 - 100 50/60 230 1 - yes polymer-coated steel - - - floor mounting Supply and exhaust - - - - 37 - 320 89 - - - - - - A -25...+40 200 96 - - 0.75 - - - counter-flow polystyrene 85...94* 40 mm mineral wool without heating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule Heat recovery efficiency is specified in compliance with EN 13141-8 47
CIVIC EC LBE 300 S21 V.2 - 101 50/60 230 1 - yes polymer-coated steel - - - floor mounting Supply and exhaust - - - - 37 - 320 89 - - - - - - A -25...+40 200 96 1050 - 0.75 7 - - counter-flow polystyrene 85...94* 40 mm mineral wool electric preheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47
CIVIC EC LBE2 300 S21 V.2 - 103 50/60 230 1 - yes polymer-coated steel - - - floor mounting Supply and exhaust - - - - 37 - 320 89 - - - - - - A -25...+40 200 96 1050 700 0.75 11 - - counter-flow polystyrene 85...94* 40 mm mineral wool electric preheating, electric reheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47
CIVIC EC LBE2 300-E S21 V.2 - 103 50/60 230 - - yes polymer-coated steel - - - floor mounting Supply and exhaust - - - - 37 - 320 89 - - - - - - A -25...+40 200 96 1050 700 0.75 11 - - counter-flow enthalpy 73...89* 40 mm mineral wool electric preheating, electric reheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47
Pages